Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Metabolic Incorporation of N ‐Acetyl Muramic Acid Probes into Bacterial Peptidoglycan

Abstract Bacterial cells utilize small carbohydrate building blocks to construct peptidoglycan (PG), a highly conserved mesh‐like polymer that serves as a protective coat for the cell. PG production has long been a target for antibiotics, and its breakdown is a source for human immune recognition. A key component of bacterial PG, N ‐acetyl muramic acid (NAM), is a vital element in many synthetically derived immunostimulatory compounds. However, the exact molecular details of these structures and how they are generated remain unknown due to a lack of chemical probes surrounding the NAM core. A robust synthetic strategy to generate bioorthogonally tagged NAM carbohydrate units is implemented. These molecules serve as precursors for PG biosynthesis and recycling. Escherichia coli cells are metabolically engineered to incorporate the bioorthogonal NAM probes into their PG network. The probes are subsequently modified using copper‐catalyzed azide‐alkyne cycloaddition to install fluorophores directly into the bacterial PG, as confirmed by super‐resolution microscopy and high‐resolution mass spectrometry. Here, synthetic notes for key elements of this process to generate the sugar probes as well as streamlined user‐friendly metabolic labeling strategies for both microbiology and immunological applications are described. © 2019 by John Wiley & Sons, Inc. Basic Protocol 1 : Synthesis of peracetylated 2‐azido glucosamine Basic Protocol 2 : Synthesis of 2‐azido and 2‐alkyne NAM Basic Protocol 3 : Synthesis of 3‐azido NAM methyl ester Basic Protocol 4 : Incorporation of NAM probes into bacterial peptidoglycan Basic Protocol 5 : Confirmation of bacterial cell wall remodeling by mass spectrometry

DeMeester, Kristen E.↗

Global optimal consensus for discrete-time multi-agent systems with bounded controls

In this paper, we consider the global optimal consensus problem for discrete-time multi-agent systems with bounded control protocols over xed undirected communication networks. Each agent is described by a discrete-time single integrator and endowed with a quadratic objective function which is private to itself. For each agent, we develop two bounded distributed protocols: bounded proportional-integral (PI) protocol and bounded integral (I) protocol, based on information receiving from its neighboring agents through the communication network and the gradient of its own objective function. We show that the proposed bounded distributed protocols with properly chosen parameters solve the global optimal consensus problem if the communication network is connected, i.e., the multi-agent system achieves consensus at a state that minimizes the sum of the objective functions of all agents. The theoretical results are illustrated by numerical simulations.

Consensus, multi-agent system, optimal control↗

Experiences at the Paul Scherrer Institute With a Remote Patient Positioning Procedure for High-Throughput Proton Radiation Therapy

Purpose: To describe a remote positioning system for accurate and efficient proton radiotherapy treatments. Methods and Materials: To minimize positioning time in the treatment room (and thereby maximize beam utility), we have adopted a method for remote patient positioning, with patients positioned and imaged outside the treatment room. Using a CT scanner, positioning is performed using orthogonal topograms with the measured differences to the reference images being used to define daily corrections to the patient table in the treatment room. Possible patient movements during transport and irradiation were analyzed through periodic acquisition of posttreatment topograms. Systematic and random errors were calculated for this daily positioning protocol and for two off-line protocols. The potential time advantage of remote positioning was assessed by computer simulation. Results: Applying the daily correction protocol, systematic errors calculated over all patients (n = 94) were below 0.6 mm, whereas random errors were below 1.5 mm and 2.5 mm, respectively, for bite-block and for mask immobilization. Differences between pre- and posttreatment images were below 2.8 mm (SD) in abdominal/pelvic region, and below 2.4 mm (SD) in the head. Retrospective data analysis for a subset of patients revealed that off-line protocols would be significantly less accurate. Computer simulations showed that remote positioning can increase patient throughput up to 30%. Conclusions: The use of a daily imaging and correction protocol based on a 'remote' CT could reduce positioning errors to below 2.5 mm and increase beam utility in the treatment room. Patient motion between imaging and treatment were not significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioprotective Effect of Moderate Wine Consumption in Patients With Breast Carcinoma

Purpose: Given the high cost and side effects of radioprotective agents such as amifostine, attention has been focused on potentially equally effective but less expensive and toxic natural substances. We evaluated the potential radioprotective effects of wine in preventing skin toxicity in patients with breast cancer. Methods and Materials: Before treatment, the medical history and habits of patients were assessed and the information recorded in their clinical folders. Patients were divided into three groups based on the dose/fractionation scheme used: control group, 60.4 Gy (standard technique); Modulated Accelerated Radiotherapy in Adjuvant treatment of breast cancer (MARA)-1 protocol group, 44 Gy (concomitant boost to tumoral bed); and MARA-2 protocol group, 60 Gy (concomitant boost to tumoral bed). The impact of the following variables on acute skin toxicity was evaluated by chart review: radiotherapy protocol, planning target volume (PTV), comorbidity (e.g., hypertension and diabetes), hemoglobin level before therapy, adjuvant hormone therapy, adjuvant chemotherapy, cigarette smoking, and drinking habits. Results: The study population consisted of 348 patients. More severe skin toxicity was significantly associated with the radiotherapy protocol (p < 0.001) and median PTV (p = 0.005). In addition, the incidence of acute toxicity of Grade 2 or greater was higher in patients without alcohol intake (38.4% vs. 22.3%, p = 0.021). The daily amount of alcohol intake also influenced the incidence of skin toxicity, with an incidence of 38.4% in patients with no wine intake, 31.8% in patients drinking half a glass per day, 13.6% in patients drinking one glass per day, and 35.0% in patients drinking two glasses per day. Multivariate analysis showed that wine intake, PTV, and radiotherapy protocol were all significantly correlated with acute toxicity. Conclusions: Our results indicate that wine may have a radioprotective effect; however, prospective studies are needed to confirm this beneficial effect of wine and its components.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction Cisplatin and Fluorouracil-Based Chemotherapy Followed by Concurrent Chemoradiation for Muscle-Invasive Bladder Cancer

Purpose: To evaluate a multimodality bladder-preserving therapy in patients with muscle-invasive bladder cancer. Methods and Materials: Patients with stages T2-4aN0M0 bladder cancer suitable for cystectomy underwent radical transurethral resection and induction chemotherapy, followed by concurrent chemoradiotherapy (CCRT). Patients with a Karnofsky performance status (KPS) <80 or age {>=}70 years underwent Protocol A: induction chemotherapy with three cycles of the cisplatin and 5-fluorouracil (CF) regimen, and CCRT with six doses of weekly cisplatin and 64.8 Gy radiotherapy given with the shrinking-field technique. Patients with KPS {>=}80 and age <70 years underwent Protocol B: induction chemotherapy with three cycles of weekly paclitaxel plus the CF regimen, and CCRT with six doses of weekly paclitaxel and cisplatin plus 64.8 Gy radiotherapy. Interval cystoscopy was employed after induction chemotherapy and when radiotherapy reached 43.2 Gy. Patients without a complete response (CR) were referred for salvage cystectomy. Results: Among 30 patients (median, 66 years) enrolled, 17 and 13 patients underwent Protocol A and B, respectively. After induction chemotherapy, 23 patients achieved CR. Five (17%) of 7 patients without CR underwent salvage cystectomy. Overall, 28 patients (93%) completed the protocol treatment. Of 22 patients who completed CCRT, 1 had recurrence with carcinoma in situ and 3 had distant metastases. After a median follow-up of 47 months, overall and progression-free survival rate for all patients were 77% and 54% at 3 years, respectively. Of 19 surviving patients, 15 (79%) retained functioning bladders. Conclusions: Our protocols may be alternatives to cystectomy for selected patients who wish to preserve the bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Position Verification for the Prostate: Effect on Rectal Wall Dose

Purpose: To evaluate the effect of gold marker (GM)-based position correction on the cumulative dose in the anorectal wall compared with traditional bony anatomy (BA)-based correction, taking into account changes in anorectal shape and position. Methods and Materials: A total of 20 consecutive prostate cancer patients, treated with curative external beam radiotherapy, were included. Four fiducial GMs were implanted in the prostate. Positioning was verified according to the shift in BA and GMs on daily electronic portal images. Position corrections were determined using on- and off-line position verification protocols according to the position of the GMs (GM-on and GM-off) and BA (BA-off). For all patients, intensity-modulated radiotherapy plans were made for the GM (8-mm planning target volume margin) and BA (10-mm planning target volume margin) protocols. The dose distribution was recomputed on 11 repeat computed tomography scans to estimate the accumulated dose to the prostate and anorectal wall while considering internal organ motion. Results: The dose that is at least received by 99% of the prostate was, on average, acceptable for all protocols. The individual patient data showed the best coverage for both GM protocols, with >95% of the prescribed dose for all patients. The anorectal wall dose was significantly lower for the GM protocols. The dose that is at least received by 30% of the rectal wall was, on average, 54.6 Gy for GM-on, 54.1 Gy for GM-off, and 58.9 Gy for BA-off (p <.001). Conclusion: Position verification with GM and reduced planning target volume margins yielded adequate treatment of the prostate and a lower rectal wall dose, even when accounting for independent movement of the prostate and anorectal wall.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols for SBRT among centers. However, the observed deviations in target volumes were generally small. They were slightly larger for the mid-ventilation phases and smallest for the end-expiration phases. Steps to optimize and standardize the 4D-CT scanning protocols for SBRT are desirable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Quality Assurance Review of External Beam Radiation Therapy in the International Society of Paediatric Oncology (Europe) Neuroblastoma Group's High-risk Neuroblastoma Trial: A SIOPEN Study

Purpose: Radiation therapy is important for local control in neuroblastoma. This study reviewed the compliance of plans with the radiation therapy guidelines of the International Society of Paediatric Oncology (Europe) Neuroblastoma Group (SIOPEN) High-Risk Trial protocol. Methods and Materials: The SIOPEN trial central electronic database has sections to record diagnostic imaging and radiation therapy planning data. Individual centers may upload data remotely, but not all centers involved in the trial chose to use this system. A quality scoring system was devised based on how well the radiation therapy plan matched the protocol guidelines, to what extent deviations were justified, and whether adverse effects may result. Central review of radiation therapy planning was undertaken retrospectively in 100 patients for whom complete diagnostic and treatment sets were available. Data were reviewed and compared against protocol guidelines by an international team of radiation oncologists and radiologists. For each patient in the sample, the central review team assigned a quality assurance score. Results: It was found that in 48% of patients there was full compliance with protocol requirements. In 29%, there were deviations for justifiable reasons with no likely long-term adverse effects resulting. In 5%, deviations had occurred for justifiable reasons, but that might result in adverse effects. In 1%, there was a deviation with no discernible justification, which would not lead to long-term adverse events. In 17%, unjustified deviations were noted, with a risk of an adverse outcome resulting. Conclusions: Owing to concern over the proportion of patients in whom unjustified deviations were observed, a protocol amendment has been issued. This offers the opportunity for central review of radiation therapy plans before the start of treatment and the treating clinician a chance to modify plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Factors Affecting Successful Clinical Trial Enrollment in the Context of Three Prospective, Randomized, Controlled Trials

Purpose: Challenges can arise when attempting to maximize patient enrollment in clinical trials. There have been limited studies focusing on the barriers to enrollment and the efficacy of alternative study design to improve accrual. We analyzed barriers to clinical trial enrollment, particularly the influence of timing, in context of three prospective, randomized oncology trials where one arm was considered more aggressive than the other. Methods and Materials: From June 2011 to March 2015, patients who were enrolled on 3 prospective institutional protocols (an oligometastatic non-small cell lung cancer [NSCLC] trial and 2 proton vs intensity modulated radiation therapy trials in NSCLC and esophageal cancer) were screened for protocol eligibility. Eligible candidates were approached about trial participation, and patient characteristics (age, sex, T/N categorization) were recorded along with details surrounding trial presentation (appointment number). Fisher's exact test, Student's t tests, and multivariate analysis were performed to assess differences between enrolled and refusal patients. Results: A total of 309 eligible patients were approached about trial enrollment. The enrollment success rate during this time span was 52% (n=160 patients). Enrolled patients were more likely to be presented trial information at an earlier appointment (oligometastatic protocol: 5 vs 3 appointments [P<.001]; NSCLC protocol: 4 vs 3 appointments [P=.0018]; esophageal protocol: 3 vs 2 appointments [P=.0086]). No other factors or patient characteristics significantly affected enrollment success rate. Conclusion: Improvement in enrollment rates for randomized control trials is possible, even in difficult accrual settings. Earlier presentation of trial information to patients is the most influential factor for success and may help overcome accrual barriers without compromising trial design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Treatment Planning Investigation Into the Dosimetric Effects of Systematic Prostate Patient Rotational Set-Up Errors

The purpose of this study was to investigate the potential dosimetric effects of systematic rotational setup errors on prostate patients planned according to the RTOG P-0126 protocol, and to identify rotational tolerances about either the anterior-posterior (AP) or left-right (LR) axis, under which no correction in setup is required. Eight 3-dimensional conformal radiation therapy (3D-CRT) treatment plans were included in the study, half planned to give 7020 cGy in 39 fractions (P-0126 Arm 1) and the other half planned to give 7920 cGy in 44 fractions (P-0126 Arm 2). Systematic rotations of the pelvic anatomy were simulated in a commercial treatment planning system by rotating opposing apertures in the opposite direction to the simulated anatomy rotation. Rotations were incremented in steps of 2.5 deg. to a maximum of {+-}5.0 deg. and {+-}10.0 deg. the AP and LR axis respectively. Dose distributions were evaluated with respect to the planning objectives set out in the P-0126 protocol. For patients on Arm 2 of the study, maintaining the prescribed dose to 98% of the PTV was found to be problematic for superior-end-posterior rotations beyond 5.0 deg. The results also show that maintaining a rectal dose less than 7500 cGy to 15% of the volume can become problematic for cases of small rectal volume and large superior-end-anterior rotations. We found that setting rotational tolerances will depend on which Arm of the protocol the patient is, and how well the initial plan meets the protocol objectives. In general, we conclude that for rotations about the AP axis, no tolerance level is required; however, cases presenting extreme rotations should be investigated as routine practice. For rotations about the LR axis, we conclude that a tolerance level for patients on Arm 2 of the protocol should be set at {+-}5.0 deg. This tolerance represents the systematic setup error which would require correction if a variation to the initial plan was deemed unacceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

Ensemble Simulations and Experimental Free Energy Distributions: Evaluation and Characterization of Isoxazole Amides as SMYD3 Inhibitors

Optimization of binding affinities for ligands to their target protein is a primary objective in rational drug discovery. Herein, we report on a collaborative study that evaluates various compounds designed to bind to the SET and MYND domain-containing protein 3 (SMYD3). SMYD3 is a histone methyltransferase and plays an important role in transcriptional regulation in cell proliferation, cell cycle, and human carcinogenesis. Experimental measurements using the scintillation proximity assay show that the distributions of binding free energies from a large number of independent measurements exhibit non-normal properties. We use ESMACS (enhanced sampling of molecular dynamics with approximation of continuum solvent) and TIES (thermodynamic integration with enhanced sampling) protocols to predict the binding free energies and to provide a detailed chemical insight into the nature of ligand-protein binding. Our results show that the 1-trajectory ESMACS protocol works well for the set of ligands studied here. Although one unexplained outlier exists, we obtain excellent statistical ranking across the set of compounds from the ESMACS protocol and good agreement between calculations and experiments for the relative binding free energies from the TIES protocol. ESMACS and TIES are again found to be powerful protocols for the accurate comparison of the binding free energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical Hamiltonian learning with unitary dynamics and Gibbs states

We study the problem of learning the parameters for the Hamiltonian of a quantum many-body system, given limited access to the system. In this work, we build upon recent approaches to Hamiltonian learning via derivative estimation. We propose a protocol that improves the scaling dependence of prior works, particularly with respect to parameters relating to the structure of the Hamiltonian (e.g., its locality k). Furthermore, by deriving exact bounds on the performance of our protocol, we are able to provide a precise numerical prescription for theoretically optimal settings of hyperparameters in our learning protocol, such as the maximum evolution time (when learning with unitary dynamics) or minimum temperature (when learning with Gibbs states). Thanks to these improvements, our protocol has practical scaling for large problems: we demonstrate this with a numerical simulation of our protocol on an 80-qubit system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Traceable random numbers from a non-local quantum advantage

The unpredictability of random numbers is fundamental to both digital security and applications that fairly distribute resources. However, existing random number generators have limitations—the generation processes cannot be fully traced, audited and certified to be unpredictable. The algorithmic steps used in pseudorandom number generators are auditable, but they cannot guarantee that their outputs were a priori unpredictable given knowledge of the initial seed. Device-independent quantum random number generators can ensure that the source of randomness was unknown beforehand, but the steps used to extract the randomness are vulnerable to tampering. Here we demonstrate a fully traceable random number generation protocol based on device-independent techniques. Our protocol extracts randomness from unpredictable non-local quantum correlations, and uses distributed intertwined hash chains to cryptographically trace and verify the extraction process. This protocol forms the basis for a public traceable and certifiable quantum randomness beacon that we have launched. Over the first 40 days of operation, we completed the protocol 7,434 out of 7,454 attempts—a success rate of 99.7%. Each time the protocol succeeded, the beacon emitted a pulse of 512 bits of traceable randomness. The bits are certified to be uniform with error multiplied by actual success probability bounded by 2−64. Further, the generation of certifiable and traceable randomness represents a public service that operates with an entanglement-derived advantage over comparable classical approaches.

97 MATHEMATICS AND COMPUTING↗

Reynolds number effects on mixing due to topological chaos

Topological chaos has emerged as a powerful tool to investigate fluid mixing. While this theory can guarantee a lower bound on the stretching rate of certain material lines, it does not indicate what fraction of the fluid actually participates in this minimally mandated mixing. Indeed, the area in which effective mixing takes place depends on physical parameters such as the Reynolds number. To help clarify this dependency, we numerically simulate the effects of a batch stirring device on a 2D incompressible Newtonian fluid in the laminar regime. In particular, we calculate the finite time Lyapunov exponent (FTLE) field for three different stirring protocols, one topologically complex (pseudo-Anosov) and two simple (finite-order), over a range of viscosities. After extracting appropriate measures indicative of both the amount of mixing and the area of effective mixing from the FTLE field, we see a clearly defined Reynolds number range in which the relative efficacy of the pseudo-Anosov protocol over the finite-order protocols justifies the application of topological chaos. More unexpectedly, we see that while the measures of effective mixing area increase with increasing Reynolds number for the finite-order protocols, they actually exhibit non-monotonic behavior for the pseudo-Anosov protocol.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficiency in nonequilibrium molecular dynamics Monte Carlo simulations

Hybrid algorithms combining nonequilibrium molecular dynamics and Monte Carlo (neMD/MC) offer a powerful avenue for improving the sampling efficiency of computer simulations of complex systems. These neMD/MC algorithms are also increasingly finding use in applications where conventional approaches are impractical, such as constant-pH simulations with explicit solvent. However, selecting an optimal nonequilibrium protocol for maximum efficiency often represents a non-trivial challenge. This work evaluates the efficiency of a broad class of neMD/MC algorithms and protocols within the theoretical framework of linear response theory. The approximations are validated against constant pH-MD simulations and shown to provide accurate predictions of neMD/MC performance. An assessment of a large set of protocols confirms (both theoretically and empirically) that a linear work protocol gives the best neMD/MC performance. Lastly, a well-defined criterion for optimizing the time parameters of the protocol is proposed and demonstrated with an adaptive algorithm that improves the performance on-the-fly with minimal cost.

97 MATHEMATICS AND COMPUTING↗