Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECOMMENDATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging

This phantom-based study was aimed to determine whether cardiac CZT-cameras, which provide an enhanced spatial resolution and image contrast compared to Anger cameras, are similarly affected by small cardiac motions. Translations of a left ventricular (LV) insert at half-SPECT acquisitions through six possible orthogonal directions and with 5- or 10-mm amplitude were simulated on the Discovery NM-530c and DSPECT CZT-cameras and on an Anger Symbia T2 camera equipped with an astigmatic (IQ.SPECT) or conventional parallel-hole collimator (Conv.SPECT). SPECT images were initially reconstructed as currently recommended for clinical routine. The heterogeneity in recorded activity from the 17 LV segments gradually increased between baseline and motions simulated at 5- and 10-mm amplitudes with all cameras, although being higher for Anger- than CZT-cameras at each step and resulting in a higher mean number of artifactual abnormal segments (at 10-mm amplitude, Conv.SPECT: 3.7; IQ.SPECT: 1.8, Discovery: 0.7, DSPECT: 0). However, this vulnerability to motion was markedly (1) decreased for Conv.SPECT reconstructed without the recommended Resolution Recovery algorithm and (2) increased for DSPECT reconstructed without the recommended cardiac model. CZT-cameras and especially the DSPECT appear less vulnerable to small cardiac motions than Anger-cameras although these differences are strongly dependent on reconstruction parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital-twin-based improvements to diagnosis, prognosis, strategy assessment, and discrepancy checking in a nearly autonomous management and control system

We report the Nearly Autonomous Management And Control System (NAMAC) is a comprehensive control system to assist plant operations by furnishing control recommendations to operators in a broad class of situations. This study refines a NAMAC system for making reasonable recommendations during complex loss of flow (LOF) scenarios with a validated EBR-II simulator, digital twins improved by machine-learning algorithms, a multi-attribute decision-making scheme, and a discrepancy checker for identifying unexpected recommendation effects. The performance of each NAMAC component is assessed, while the capability of NAMAC is demonstrated and evaluated in a class of LOF scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A meta-learning based distribution system load forecasting model selection framework

This paper presents a meta-learning based, automatic distribution system load forecasting model selection framework. Furthermore, the framework includes the following processes: feature extraction, candidate model preparation and labeling, offline training, and online model recommendation. Using load forecasting needs and data characteristics as input features, multiple metalearners are used to rank the candidate load forecast models based on their forecasting accuracy. Then, a scoring-voting mechanism is proposed to weights recommendations from each meta-leaner and make the final recommendations. Heterogeneous load forecasting tasks with different temporal and technical requirements at different load aggregation levels are set up to train, validate, and test the performance of the proposed framework. Simulation results demonstrate that the performance of the meta-learning based approach is satisfactory in both seen and unseen forecasting tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clinical Practice Guidance for Radiotherapy Planning After Induction Chemotherapy in Locoregionally Advanced Head-and-Neck Cancer

Purpose: The use of induction chemotherapy (IC) for locoregionally advanced head-and-neck cancer is increasing. The response to IC often causes significant alterations in tumor volume and location and shifts in normal anatomy. Proper determination of the radiotherapy (RT) targets after IC becomes challenging, especially with the use of conformal and precision RT techniques. Therefore, a consensus conference was convened to discuss issues related to RT planning and coordination of care for patients receiving IC. Methods and Materials: Ten participants with special expertise in the various aspects of integration of IC and RT for the treatment of locoregionally advanced head-and-neck cancer, including radiation oncologists, medical oncologists, and a medical physicist, participated. The individual members were assigned topics for focused, didactic presentations. Discussion was encouraged after each presentation, and recommendations were formulated. Results: Recommendations and guidelines emerged that emphasize up-front evaluation by all members of the head-and-neck management team, high-quality baseline and postinduction planning scans with the patient in the treatment position, the use of preinduction target volumes, and the use of full-dose RT, even in the face of a complete response. Conclusion: A multidisciplinary approach is strongly encouraged. Although these recommendations were provided primarily for patients treated with IC, many of these same principles apply to concurrent chemoradiotherapy without IC. A rapid response during RT is quite common, requiring the development of two or more plans in a sizeable fraction of patients, and suggesting the need for similar guidance in the rapidly evolving area of adaptive RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Study of Preoperative Chemoradiation With S-1 and Oxaliplatin in Patients With Locally Advanced Resectable Rectal Cancer

Purpose: To perform a Phase I study of preoperative chemoradiation (CRT) with S-1, a novel oral fluoropyrimidine, plus oxaliplatin in patients with locally advanced rectal cancer, to determine the maximum tolerated dose and the recommended dose. Methods and Materials: Radiotherapy was delivered to a total of 45 Gy in 25 fractions and followed by a coned-down boost of 5.4 Gy in 3 fractions. Concurrent chemotherapy consisted of a fixed dose of oxaliplatin (50 mg/m{sup 2}/week) on Days 1, 8, 22, and 29 and escalated doses of S-1 on Days 1-14 and 22-35. The initial dose of S-1 was 50 mg/m{sup 2}/day, gradually increasing to 60, 70, and 80 mg/m{sup 2}/day. Surgery was performed within 6 {+-} 2 weeks. Results: Twelve patients were enrolled and tolerated up to Dose Level 4 (3 patients at each dose level) without dose-limiting toxicity. An additional 3 patients were enrolled at Dose Level 4, with 1 experiencing a dose-limiting toxicity of Grade 3 diarrhea. Although maximum tolerated dose was not attained, Dose Level 4 (S-1 80 mg/m{sup 2}/day) was chosen as the recommended dose for further Phase II studies. No Grade 4 toxicity was observed, and Grade 3 toxicities of leukopenia and diarrhea occurred in the same patient (1 of 15, 6.7%). Pathologic complete responses were observed in 2 of 15 patients (13.3%). Conclusions: The recommended dose of S-1 was determined to be 80 mg/m{sup 2}/day when combined with oxaliplatin in preoperative CRT, and a Phase II trial is now ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The American Society for Radiation Oncology's 2015 Core Physics Curriculum for Radiation Oncology Residents

Purpose: The American Society for Radiation Oncology (ASTRO) Physics Core Curriculum Subcommittee (PCCSC) has updated the recommended physics curriculum for radiation oncology resident education to improve consistency in teaching, intensity, and subject matter. Methods and Materials: The ASTRO PCCSC is composed of physicists and physicians involved in radiation oncology residency education. The PCCSC updated existing sections within the curriculum, created new sections, and attempted to provide additional clinical context to the curricular material through creation of practical clinical experiences. Finally, we reviewed the American Board of Radiology (ABR) blueprint of examination topics for correlation with this curriculum. Results: The new curriculum represents 56 hours of resident physics didactic education, including a 4-hour initial orientation. The committee recommends completion of this curriculum at least twice to assure both timely presentation of material and re-emphasis after clinical experience. In addition, practical clinical physics and treatment planning modules were created as a supplement to the didactic training. Major changes to the curriculum include addition of Fundamental Physics, Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy, and Safety and Incidents sections, and elimination of the Radiopharmaceutical Physics and Dosimetry and Hyperthermia sections. Simulation and Treatment Verification and optional Research and Development in Radiation Oncology sections were also added. A feedback loop was established with the ABR to help assure that the physics component of the ABR radiation oncology initial certification examination remains consistent with this curriculum. Conclusions: The ASTRO physics core curriculum for radiation oncology residents has been updated in an effort to identify the most important physics topics for preparing residents for careers in radiation oncology, to reflect changes in technology and practice since the publication of previous recommended curricula, and to provide practical training modules in clinical radiation oncology physics and treatment planning. The PCCSC is committed to keeping the curriculum current and consistent with the ABR examination blueprint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Reported Outcomes After Radiation Therapy in Men With Prostate Cancer: A Systematic Review of Prognostic Tool Accuracy and Validity

Purpose: To identify, through a systematic review, all validated tools used for the prediction of patient-reported outcome measures (PROMs) in patients being treated with radiation therapy for prostate cancer, and provide a comparative summary of accuracy and generalizability. Methods and Materials: PubMed and EMBASE were searched from July 2007. Title/abstract screening, full text review, and critical appraisal were undertaken by 2 reviewers, whereas data extraction was performed by a single reviewer. Eligible articles had to provide a summary measure of accuracy and undertake internal or external validation. Tools were recommended for clinical implementation if they had been externally validated and found to have accuracy ≥70%. Results: The search strategy identified 3839 potential studies, of which 236 progressed to full text review and 22 were included. From these studies, 50 tools predicted gastrointestinal/rectal symptoms, 29 tools predicted genitourinary symptoms, 4 tools predicted erectile dysfunction, and no tools predicted quality of life. For patients treated with external beam radiation therapy, 3 tools could be recommended for the prediction of rectal toxicity, gastrointestinal toxicity, and erectile dysfunction. For patients treated with brachytherapy, 2 tools could be recommended for the prediction of urinary retention and erectile dysfunction. Conclusions: A large number of tools for the prediction of PROMs in prostate cancer patients treated with radiation therapy have been developed. Only a small minority are accurate and have been shown to be generalizable through external validation. This review provides an accessible catalogue of tools that are ready for clinical implementation as well as which should be prioritized for validation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring the Interestingness of Articles in a Limited User Environment

Search engines, such as Google, assign scores to news articles based on their relevance to a query. However, not all relevant articles for the query may be interesting to a user. For example, if the article is old or yields little new information, the article would be uninteresting. Relevance scores do not take into account what makes an article interesting, which would vary from user to user. Although methods such as collaborative filtering have been shown to be effective in recommendation systems, in a limited user environment, there are not enough users that would make collaborative filtering effective. A general framework, called iScore, is presented for defining and measuring the ‘‘interestingness of articles, incorporating user-feedback. iScore addresses the various aspects of what makes an article interesting, such as topic relevance, uniqueness, freshness, source reputation, and writing style. It employs various methods, such as multiple topic tracking, online parameter selection, language models, clustering, sentiment analysis, and phrase extraction to measure these features. Due to varying reasons that users hold about why an article is interesting, an online feature selection method in naι¨ve Bayes is also used to improve recommendation results. iScore can outperform traditional IR techniques by as much as 50.7%. iScore and its components are evaluated in the news recommendation task using three datasets from Yahoo! News, actual users, and Digg.

99 GENERAL AND MISCELLANEOUS↗

Best practices for predictions of radionuclide activity concentrations and total absorbed dose rates to freshwater organisms exposed to uranium mining/milling

Predictions of radionuclide dose rates to freshwater organisms can be used to evaluate the radiological environmental impacts of releases from uranium mining and milling projects. These predictions help inform decisions on the implementation of mitigation measures. The objective of this study was to identify how dose rate modelling could be improved to reduce uncertainty in predictions to non-human biota. For this purpose, we modelled the activity concentrations of 210 Pb, 210 Po, 226 Ra, 230 Th, and 238 U downstream of uranium mines and mills in northern Saskatchewan, Canada, together with associated weighted absorbed dose rates for a freshwater food chain using measured activity concentrations in water and sediments. Differences in predictions of radionuclide activity concentrations occurred mainly from the different default partition coefficient and concentration ratio values from one model to another and including all or only some 238 U decay daughters in the dose rate assessments. Consequently, we recommend a standardized best-practice approach to calculate weighted absorbed dose rates to freshwater biota whether a facility is at the planning, operating or decommissioned stage. At the initial planning stage, the best-practice approach recommend using conservative site-specific baseline activity concentrations in water, sediments and organisms and predict conservative incremental activity concentrations in these media by selecting concentration ratios based on species similarity and similar water quality conditions to reduce the uncertainty in dose rate calculations. At the operating and decommissioned stages, the best-practice approach recommends relying on measured activity concentrations in water, sediment, fish tissue and wholebody of small organisms to further reduce uncertainty in dose rate estimates. This approach would allow for more realistic but still conservative dose assessments when evaluating impacts from uranium mining projects and making decision on adequate controls of releases.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

On the Use of SRIM for Computing Radiation Damage Exposure

The SRIM (formerly TRIM) Monte Carlo simulation code is widely used to compute a number of parameters relevant to ion beam implantation and ion beam processing of materials. It also has the capability to compute a common radiation damage exposure unit known as atomic displacements per atom (dpa). Since dpa is a standard measure of primary radiation damage production, most researchers who employ ion beams as a tool for inducing radiation damage in materials use SRIM to determine the dpa associated with their irradiations. The use of SRIM for this purpose has been evaluated and comparisons have been made with an internationally-recognized standard definition of dpa, as well as more detailed atomistic simulations of atomic displacement cascades. Differences between the standard and SRIM-based dpa are discussed and recommendations for future usage of SRIM in radiation damage studies are made. In particular, it is recommended that when direct comparisons between ion and neutron data are intended, the Kinchin-Pease option of SRIM should be selected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vitamin B12 added as a fortificant to flour retains high bioavailability when baked in bread

Vitamin B12 deficiency and depletion are common world-wide, particularly in populations that consume low amounts of animal source foods. WHO and the Food Fortification Initiative recommend that wheat flour be fortified with vitamin B12 in regions where intake of B12 is low. The purpose of this pilot study in five participants was to determine if fortification of flour with B12 produced a bread product with intact B12 still present and to determine if healthy elderly absorb sufficient B12 from bread fortified in this manner. High-purity crystalline 14C-B12 was dissolved in water and added to flour (2 µg B12/100 g flour) in a bread maker and made into rolls (average 1.17 kBq (31.5 nCi) 14 C-B12 in a total of 0.8 µg B12 per roll). Excess 14 C first appeared in plasma 4 h after ingestion of the 14 C fortified bread and plasma levels returned almost to background by 72 h. Measurement of 14 C in plasma verified that the dose was absorbed into the systemic circulation. The cumulative % dose recovered in urine was 4.8–37.0% (mean = 20.1%). Most of the 14 C label in the stool appeared by day 4, and the cumulative % dose recovered in stool was 24.5–43.0% (mean = 31.8%). Bioavailability among the 5 participants, calculated by subtracting the sum of urinary and fecal 14 C excretion from the administered dose, was 28.4–63.7% (mean = 48.0%). This study showed that when B12 is added as a fortificant to flour it survives the fermentation and baking processes, and retains ~50% bioavailability when fed in small doses to healthy subjects. The Recommended Dietary Allowance of B12 for adults is 2.4 µg/d. This recommendation assumes that usual bioavailability of low doses of the vitamin in the crystalline form is 60%, while for the same amount in foods such as meat and fish it is 50%. Lastly, our pilot study shows that B12 added to bread as a fortificant in flour was absorbed as well as it is from endogenous food sources such as meat and fish.

59 BASIC BIOLOGICAL SCIENCES↗

WEEE and portable batteries in residual household waste: Quantification and characterisation of misplaced waste

Highlights: • We analyse 26.1 Mg of residual waste from 3129 Danish households. • We quantify and characterise misplaced WEEE and portable batteries. • We compare misplaced WEEE and batteries to collection through dedicated schemes. • Characterisation showed that primarily small WEEE and light sources are misplaced. • Significant amounts of misplaced batteries were discarded as built-in WEEE. - Abstract: A total of 26.1 Mg of residual waste from 3129 households in 12 Danish municipalities was analysed and revealed that 89.6 kg of Waste Electrical and Electronic Equipment (WEEE), 11 kg of batteries, 2.2 kg of toners and 16 kg of cables had been wrongfully discarded. This corresponds to a Danish household discarding 29 g of WEEE (7 items per year), 4 g of batteries (9 batteries per year), 1 g of toners and 7 g of unidentifiable cables on average per week, constituting 0.34% (w/w), 0.04% (w/w), 0.01% (w/w) and 0.09% (w/w), respectively, of residual waste. The study also found that misplaced WEEE and batteries in the residual waste constituted 16% and 39%, respectively, of what is being collected properly through the dedicated special waste collection schemes. This shows that a large amount of batteries are being discarded with the residual waste, whereas WEEE seems to be collected relatively successfully through the dedicated special waste collection schemes. Characterisation of the misplaced batteries showed that 20% (w/w) of the discarded batteries were discarded as part of WEEE (built-in). Primarily alkaline batteries, carbon zinc batteries and alkaline button cell batteries were found to be discarded with the residual household waste. Characterisation of WEEE showed that primarily small WEEE (WEEE directive categories 2, 5a, 6, 7 and 9) and light sources (WEEE directive category 5b) were misplaced. Electric tooth brushes, watches, clocks, headphones, flashlights, bicycle lights, and cables were items most frequently found. It is recommended that these findings are taken into account when designing new or improving existing special waste collection schemes. Improving the collection of WEEE is also recommended as one way to also improve the collection of batteries due to the large fraction of batteries found as built-in. The findings in this study were comparable to other western European studies, suggesting that the recommendations made in this study could apply to other western European countries as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defect-Engineered High-Entropy Spinel Oxide@Onion-Like Carbon Catalysts for High-Areal-Energy Rechargeable Zinc–Air Batteries

Rechargeable zinc-air batteries (ReZAB) have emerged as the next-generation batteries with several advantages over the conventional lithium-ion battery. In this work, single nanocrystals of inverse-type high-entropy spinel oxides (HESOx, particle size of 10−12 nm) confined in highly curved defective onion-like carbons (HESOx/OLC AT ) as efficient electrocatalysts for oxygen evolution reaction (OER), oxygen reduction reaction (ORR), and ReZAB, have been synthesized. The HESOx materials were thoroughly characterized using several analytical techniques, including X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning transmission electron microscopy (STEM), Raman, and electron paramagnetic resonance (EPR). HESOx/OLC AT catalyst was tested for ReZAB using literature-recommended parameters that would allow for real technological application. These parameters include a current loading of 10 mA cm −2 and a discharge areal energy density of 35 mWh cm geometric −2 , which maps a Li-ion battery pack-level specific energy of 120 Wh kg pack −1 . HESOx/OLC AT electrocatalysts allowed for continuous discharging and charging at a current loading of 10 mA cm −2 with discharge areal energy densities between 37 and 74 mWh cm geometric −2 , thus outperforming the recommended threshold of 35 mWh cm geometric −2 . Considering that most studies (>90%) hardly meet the recommended threshold for technological application of ReZAB, the present work represents one of the top-performing electrocatalysts for ReZAB. The excellent electrocatalytic properties of defect-rich HESOx/OLC AT toward ORR/OER and ReZAB are governed by the strong electronic modulation arising from d-π hybridization, the availability of multiple catalytic sites for intermediates, and weakened d-band centers of the rate-determining intermediates (i.e., *O adsorption for ORR and *OOH formation for OER) compared to the pristine HESOx. This work introduces an effective approach for the design and synthesis of single nanocrystals of high-entropy electrocatalysts for the development of low-cost, robust, and technologically relevant rechargeable zinc−air batteries.

25 ENERGY STORAGE↗

A Simple Correction for Nonadditive Dispersion within Extended Symmetry-Adapted Perturbation Theory (XSAPT)

Extended symmetry-adapted perturbation theory (XSAPT), in conjunction with empirical “+aiD” potentials fit to ab initio dispersion data, is a low-scaling approach to compute intermolecular interaction energies in noncovalent clusters. One shortcoming is that the aiD atom–atom dispersion potentials are independent of the chemical environment of the atoms in question and therefore neglect nonadditive dispersion effects. These can be significant in large systems, so to account for them we test a simple correction to XSAPT(KS)+aiD, where “KS” indicates the use of Kohn–Sham orbitals. This correction, which can be evaluated at fourth-order cost using double-ζ basis sets, is based on comparing second-order SAPT dispersion with and without a self-consistent charge embedding for the monomer wave functions. The correction amounts to ~1.4 kcal/mol in (H 2 O) 6 but ~5.5 kcal/mol in (H 2 O) 20 . With the nonadditive dispersion correction, XSAPT(KS)+aiD affords errors of ~1 kcal/mol for isomers of F–(H 2 O) 10 and (H 2 O) 20 , where the benchmarks are complete-basis CCSD(T) energies, as well as for ion–water clusters X(H 2 O)n where n ≤ 6 and X = F – , Cl – , SO 4 2– , Li + , Na + , or K + . We also test the MP2 method and a variety of density-functional methods that have been specifically recommended for noncovalent interactions. Among the latter, only ωB97X-V and ωB97M-V can be recommended for ion–water clusters, as mean errors for other popular approaches (including ωB97X-D3 and several Minnesota functionals) exceed 1 kcal/mol. Lastly, we examine clathrate-hydrate host/guest complexes whose mixture of hydrogen bonding and dispersion make them challenging tests for noncovalent quantum chemistry. Although the B97-D2 functional performs best for clathrate hydrates and has been previously recommended in other studies of these inclusion complexes, its performance for other systems examined here is quite poor. We are unable to find a functional whose accuracy is ≲1 kcal/mol accuracy for both clathrate hydrates and ion–water clusters. However, the XSAPT(KS)+aiD method with the nonadditive dispersion correction can achieve this, with a mean error for the clathrate hydrates of 0.3 kcal/mol.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enabling real-time multi-messenger astrophysics discoveries with deep learning

Multi-messenger astrophysics is a fast-growing, interdisciplinary field that combines data, which vary in volume and speed of data processing, from many different instruments that probe the Universe using different cosmic messengers: electromagnetic waves, cosmic rays, gravitational waves and neutrinos. In this Expert Recommendation, we review the key challenges of real-time observations of gravitational wave sources and their electromagnetic and astroparticle counterparts, and make a number of recommendations to maximize their potential for scientific discovery. These recommendations refer to the design of scalable and computationally efficient machine learning algorithms; the cyber-infrastructure to numerically simulate astrophysical sources, and to process and interpret multi-messenger astrophysics data; the management of gravitational wave detections to trigger real-time alerts for electromagnetic and astroparticle follow-ups; a vision to harness future developments of machine learning and cyber-infrastructure resources to cope with the big-data requirements; and finally, the need to build a community of experts to realize the goals of multi-messenger astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of IRDFF in 252Cf standard and IRDF-2002 reference neutron fields

The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f.) and reference 235U(nth,f) neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm the recommended spectrum for 252Cf spontaneous fission source; that was not the case for the current recommended spectra for 235U(nth,f). IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF- 2002 collection. Before this analysis, the ISFN spectrum was resimulated to remove unphysical oscillations in spectrum. IRDFF-1.03 was shown to reasonably reproduce the spectrum-averaged data measured in these fields except for the case of YAYOI.

IRDFF↗

Evolution of the ATLAS analysis model for Run-3 and prospects for HL-LHC

With an increased dataset obtained during the Run-2 of the LHC at CERN, the even larger forthcoming Run-3 data and the expected increase of the dataset by more than one order of magnitude for the HL-LHC, the AT-LAS experiment is reaching the limits of the current data production model in terms of disk storage resources. The anticipated availability of an improved fast simulation will enable ATLAS to produce significantly larger Monte Carlo samples with the available CPU, which will then be limited by insufficient disk resources. The ATLAS Analysis Model Study Group for Run-3 was setup at the end of Run-2. Its tasks have been to analyse the efficiency and suitability of the current analysis model and to propose significant improvements. The group has considered options allowing ATLAS to save, for the same sample of data and simulated events, at least 30% disk space overall, and has given recommendations on how significantly larger savings could be realised for the HL-LHC. Furthermore, suggestions were made to harmonise the current stage of analysis across the collaboration. The group has now completed its work: key recommendations will be the new small sized analysis formats DAOD_PHYS and DAOD_PHYSLITE and the increased usage of a tape carousel mode in the centralised production of these formats. This proceeding reviews the recommended ATLAS analysis model for Run-3 and the status of its implementation. It also provides an outlook to the HL-LHC analysis.

97 MATHEMATICS AND COMPUTING↗