Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Mechanical Response of Castlegate Sandstone under Hydrostatic Cyclic Loading

The stress history of rocks in the subsurface affects their mechanical and petrophysical properties. Rocks can often experience repeated cycles of loading and unloading due to fluid pressure fluctuations, which will lead to different mechanical behavior from static conditions. This is of importance for several geophysical and industrial applications, for example, wastewater injection and reservoir storage wells, which generate repeated stress perturbations. Laboratory experiments were conducted with Castlegate sandstone to observe the effects of different cyclic pressure loading conditions on a common reservoir analogue. Each sample was hydrostatically loaded in a triaxial cell to a low effective confining pressure, and either pore pressure or confining pressure was cycled at different rates over the course of a few weeks. Fluid permeability was measured during initial loading and periodically between stress cycles. Samples that undergo cyclic loading experience significantly more inelastic (nonrecoverable) strain compared to samples tested without cyclic hydrostatic loading. Permeability decreases rapidly for all tests during the first few days of testing, but the decrease and variability of permeability after this depend upon the loading conditions of each test. Cycling conditions do affect the mechanical behavior; the elastic moduli decrease with the increasing loading rate and stress cycling. The degree of volumetric strain induced by stress cycles is the major control on permeability change in the sandstones, with less compaction leading to more variation from measurement to measurement. The data indicate that cyclic loading degrades permeability and porosity more than static conditions over a similar period, but the petrophysical properties are dictated more by the hydrostatic loading rate rather than the total length of time stress cycling is imposed.

58 GEOSCIENCES↗

Time-Resolved Serial Femtosecond Crystallography at the EuXFEL

There are 4 different stream files here. Pure dark is only dark run without any usage of LASER excitation. Control experiment is 0.89 microsecond time delay experiment with light and 2 da rk interleaved. i.e Light, Dark1 and Dark2 and the sequence repeats 10ps and 80ps time delays experiments were ran with light and 3 dark interleaved. i.e Light, Dark1, Dark2 and Dark3 and the sequence repeats.

European XFEL↗

Sandia PUF Analysis Tool

This program is a graphical user interface for measuring and performing inter-active analysis of physical unclonable functions (PUFs). It is intended for demonstration and education purposes. See license.txt for license details. The program features a PUF visualization that demonstrates how signatures differ between PUFs and how they exhibit noise over repeated measurements. A similarity scoreboard shows the user how close the current measurement is to the closest chip signatures in the database. Other metrics such as average noise and inter-chip Hamming distances are presented to the user. Randomness tests published in NIST SP 800-22 can be computed and displayed. Noise and inter-chip histograms for the sample of PUFs and repeated PUF measurements can be drawn.

Source record↗

wuhrlab/BACIQ

Multiplexed proteomics has emerged as a powerful tool to measure relative protein expression levels across multiple conditions. The relative protein abundances are inferred by comparing the signals generated by isobaric tags, which encode the samples’ origins. Intuitively, the trust associated with a protein measurement depends on the similarity of ratios from the protein’s peptides and the signal-strength of these measurements. However, typically the average peptide ratio is reported as the estimate of relative protein abundance, which is only the most likely ratio with a very naive model. Moreover, there is no sense on the confidence in these measurements. Here, we present a mathematically rigorous approach that integrates peptide signal strengths and peptide-measurement agreement into an estimation of the true protein ratio and the associated confidence (BACIQ). The main advantages of BACIQ are: It removes the need to threshold reported peptide signal based on an arbitrary cut-off, thereby reporting more measurements from a given experiment; Confidence can be assigned without replicates; For repeated experiments BACIQ provides confidence intervals for the union, not the intersection, of quantified proteins; and For repeated experiments, BACIQ confidence intervals are more predictive than confidence intervals based on protein measurement agreement. To demonstrate the power of BACIQ, we reanalyzed previously published data on subcellular protein movement upon treatment with an Exportin-1 inhibiting drug. We detect ~2x more highly significant movers, down to subcellular localization changes of ~1% . Thus, our method drastically increases the value obtainable from quantitative proteomics experiments helping researchers to interpret their data and prioritize resources. To make our approach easily accessible we distribute it via a Python/Stan package.

Peshkin, Leonid↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Impact Mapping for Geospatial Reasoning and Decision Making

Objective The reported study evaluated a novel approach to aiding geospatial reasoning and decision making. Background Impact mapping aims to alleviate the cognitive demands of geospatial tasks in part by externalizing data in the form of an integrated decision surface. This is achieved by aggregating data across multiple sources of information and visualizing their combined utility rather than objective measurements or individual utility. Previous research has shown that geospatial decisions improve when aided in this manner, but it remains unknown if dynamic decision making, often plagued by fatigue and anchoring bias, would benefit similarly. Method The experiment implemented a systematic manipulation of the presence of a composite impact map and the number of attributes present in a two-stage disaster relief, resource allocation task to investigate when and how impact mapping is beneficial or deleterious to decision makers. Results The presence of the composite impact map increased the utility of selected sites, increased re-planning decisions, reduced information display views, and reduced workload. Generally, the effect of the composite impact map was greater when participants were asked to evaluate more attributes. Conclusion Composite impact maps appear to improve repeated geospatial reasoning and minimize anchoring bias because they alleviate the cognitive demands otherwise necessary to interpret and maintain information from multiple attributes. Application Data visualization techniques, such as impact mapping, can improve repeated geospatial decision making in environments that include high cognitive demand.

Illingworth, David A.↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

High-Level Chromate Resistance in Arthrobacter sp. strain FB24 Requires Previously Uncharacterized Accessory Genes

The annotated genome sequence of Arthrobacter sp. strain FB24 revealed a chromate resistance determinant (CRD): a cluster of 8 genes located on a 10.6 kb fragment of a 96 kb plasmid. The CRD includes chrA, which encodes a putative chromate efflux protein, and three genes with amino acid similarities to the amino and carboxy termini of ChrB, a putative regulatory protein. There are also three novel genes that have not been previously associated with chromate resistance in other bacteria; they encode an oxidoreductase (most similar to malate:quinone oxidoreductase), a functionally unknown protein with a WD40 repeat domain and a lipoprotein. A chromate-sensitive mutant (strain D11) was generated by curing FB24 of its 96-kb plasmid. Elemental analysis indicated that chromate-exposed cells of strain D11 accumulated three times more chromium than strain FB24. Introduction of the CRD into strain D11 conferred chromate resistance comparable to wild-type levels, whereas deletion of specific regions of the CRD led to decreased resistance. Using real-time reverse transcriptase PCR, we show that expression of each gene within the CRD is specifically induced in response to chromate but not by lead, hydrogen peroxide or arsenate. Higher levels of chrA expression were achieved when the chrB orthologs and the WD40 repeat domain genes were present, suggesting their regulatory roles. Collectively, our findings indicate that chromate resistance in strain FB24 is primarily achieved by plasmid-mediated chromate efflux with the contribution of previously unrecognized accessory genes.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of short-read sequencing on the misassembly of a plant genome

Abstract Background Availability of plant genome sequences has led to significant advances. However, with few exceptions, the great majority of existing genome assemblies are derived from short read sequencing technologies with highly uneven read coverages indicative of sequencing and assembly issues that could significantly impact any downstream analysis of plant genomes. In tomato for example, 0.6% (5.1 Mb) and 9.7% (79.6 Mb) of short-read based assembly had significantly higher and lower coverage compared to background, respectively. Results To understand what the causes may be for such uneven coverage, we first established machine learning models capable of predicting genomic regions with variable coverages and found that high coverage regions tend to have higher simple sequence repeat and tandem gene densities compared to background regions. To determine if the high coverage regions were misassembled, we examined a recently available tomato long-read based assembly and found that 27.8% (1.41 Mb) of high coverage regions were potentially misassembled of duplicate sequences, compared to 1.4% in background regions. In addition, using a predictive model that can distinguish correctly and incorrectly assembled high coverage regions, we found that misassembled, high coverage regions tend to be flanked by simple sequence repeats, pseudogenes, and transposon elements. Conclusions Our study provides insights on the causes of variable coverage regions and a quantitative assessment of factors contributing to plant genome misassembly when using short reads and the generality of these causes and factors should be tested further in other species.

59 BASIC BIOLOGICAL SCIENCES↗

Baseline [ 18 F]GTP1 tau PET imaging is associated with subsequent cognitive decline in Alzheimer’s disease

Background: The role and implementation of tau PET imaging for predicting subsequent cognitive decline in Alzheimer’s disease (AD) remains uncertain. This study was designed to evaluate the relationship between baseline [ 18 F]GTP1 tau PET and subsequent longitudinal change across multiple cognitive measures over 18 months. Methods: Our analyses incorporated data from 67 participants, including cognitively normal controls (n = 10) and β-amyloid (Aβ)-positive individuals ([ 18 F] florbetapir Aβ PET) with prodromal (n = 26), mild (n = 16), or moderate (n = 15) AD. Baseline measurements included cortical volume (MRI), tau burden ([ 18 F]GTP1 tau PET), and cognitive assessments [Mini-Mental State Examination (MMSE), Clinical Dementia Rating (CDR), 13-item version of the Alzheimer’s Disease Assessment Scale-Cognitive Subscale (ADAS-Cog13), and Repeatable Battery for the Assessment of Neuropsychological Status (RBANS)]. Cognitive assessments were repeated at 6-month intervals over an 18-month period. Associations between baseline [ 18 F]GTP1 tau PET indices and longitudinal cognitive performance were assessed via univariate (Spearman correlations) and multivariate (linear mixed effects models) approaches. The utility of potential prognostic tau PET cut points was assessed with ROC curves. Results: Univariate analyses indicated that greater baseline [ 18 F]GTP1 tau PET signal was associated with faster rates of subsequent decline on the MMSE, CDR, and ADAS-Cog13 across regions of interest (ROIs). In multivariate analyses adjusted for baseline age, cognitive performance, cortical volume, and Aβ PET SUVR, the prognostic performance of [ 18 F]GTP1 SUVR was most robust in the whole cortical gray ROI. When AD participants were dichotomized into low versus high tau subgroups based on baseline [ 18 F]GTP1 PET standardized uptake value ratios (SUVR) in the temporal (cutoff = 1.325) or whole cortical gray (cutoff = 1.245) ROIs, high tau subgroups demonstrated significantly more decline on the MMSE, CDR, and ADAS-Cog13. Conclusions: Our results suggest that [ 18 F]GTP1 tau PET represents a prognostic biomarker in AD and are consistent with data from other tau PET tracers. Tau PET imaging may have utility for identifying AD patients at risk for more rapid cognitive decline and for stratification and/or enrichment of participant selection in AD clinical trials.

60 APPLIED LIFE SCIENCES↗

Reliability, stability during long-term storage, and intra-individual variation of circulating levels of osteopontin, osteoprotegerin, vascular endothelial growth factor-A, and interleukin-17A

Background: Studies in many populations have reported associations between circulating cytokine levels and various physiological or pathological conditions. However, the reliability of cytokine measurements in population studies, which measure cytokines in multiple assays over a prolonged period, has not been adequately examined; nor has stability during sample storage or intra-individual variation been assessed. Methods: We assessed (1) analytical reliability in short- and long-term repeated measurements; (2) stability and analytical reliability during long-term sample storage, and (3) variability within individuals over seasons, of four cytokines—osteopontin (OPN), osteoprotegerin (OPG), vascular endothelial growth factor-A (VEGF-A), and interleukin-17A (IL-17A). Measurements in plasma or serum samples were made with commercial kits according to standard procedures. Estimation was performed by fitting a random or mixed effects linear model on the log scale. Results: In repeated assays over a short period, OPN, OPG, and VEGF-A had acceptable reliability, with intra- and inter-assay coefficients of variation (CV) less than 0.11. Reliability of IL-17A was poor, with inter- and intra-assay CV 0.85 and 0.43, respectively. During long-term storage, OPG significantly decayed (-33% per year; 95% confidence interval [-54, -3.7]), but not OPN or VEGF-A (-0.3% or -6.3% per year, respectively). Intra- and inter-assay CV over a long period were comparable to that in a short period except for a slight increase in inter-assay CV of VEGF-A. Within-individual variation was small for OPN and VEGF-A, with intra-class correlations (ICC) 0.68 and 0.83, respectively, but large for OPG (ICC 0.11). Conclusions: We conclude that OPN and VEGF-A can be reliably measured in a large population, that IL-17A is suitable only for small experiments, and that OPG should be assessed with caution due to degradation during storage and intra-individual variation. The overall results of our study illustrate the need for validation under relevant conditions when measuring circulating cytokines in population studies.

60 APPLIED LIFE SCIENCES↗

Perceptions of Barriers Towards Active Surveillance for Low-Risk Prostate Cancer: Results From a National Survey of Radiation Oncologists and Urologists

Purpose: The reasons for low clinical adoption of active surveillance (AS) for low-risk prostate cancer (PCa) remain poorly understood. Thus, we conducted a national survey of radiation oncologists (ROs) and urologists (UROs) to elucidate perceived barriers to AS for low-risk PCa. Methods: In 2017, we undertook a four-wave mail survey of 1855 ROs and UROs. The survey instrument assessed attitudes about possible barriers towards AS for low-risk PCa. We used Pearson Chi square and multivariable logistic regression analyses to identify physician characteristics associated with attitudes about AS. Results: We received 691 completed surveys for an overall response rate of 37.3%. A majority of respondents indicated that they felt comfortable recommending AS (90.0%), agreed that high-level evidence supports it (82.3%), and considered AS equally effective for survival compared with surgery and radiation therapy (84.4%). UROs were less likely to agree that patients were not interested in AS for low-risk PCa compared with ROs (16.5 vs. 48.9%; adjusted odds ratio [OR] 0.18, p < 0.001). Similarly, UROs were less likely to concur patients avoid AS because of repeat prostate biopsies than ROs (36.3 vs. 55.4%; adjusted OR 0.41, p < 0.001). ROs and UROs were more likely to agree that patients preferred treatments delivered by the respondent’s specialty. Conclusions: Physician perceptions of patient lack of interest in AS, need for repeat prostate biopsies, and biases of patient treatment preferences in favor of their own specialty treatments represent key barriers to AS. Shared decision making may be a meaningful approach to engaging patients in conversations about treatment decisions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fission yeast RNA triphosphatase reads an Spt5 CTD code

mRNA capping enzymes are directed to nascent RNA polymerase II (Pol2) transcripts via interactions with the carboxy-terminal domains (CTDs) of Pol2 and transcription elongation factor Spt5. Fission yeast RNA triphosphatase binds to the Spt5 CTD, comprising a tandem repeat of nonapeptide motif TPAWNSGSK. Here we report the crystal structure of a Pct1·Spt5-CTD complex, which revealed two CTD docking sites on the Pct1 homodimer that engage TPAWN segments of the motif. Each Spt5 CTD interface, composed of elements from both subunits of the homodimer, is dominated by van der Waals contacts from Pct1 to the tryptophan of the CTD. The bound CTD adopts a distinctive conformation in which the peptide backbone makes a tight U-turn so that the proline stacks over the tryptophan. We show that Pct1 binding to Spt5 CTD is antagonized by threonine phosphorylation. Our results fortify an emerging concept of an “Spt5 CTD code” in which (i) the Spt5 CTD is structurally plastic and can adopt different conformations that are templated by particular cellular Spt5 CTD receptor proteins; and (ii) threonine phosphorylation of the Spt5 CTD repeat inscribes a binary on–off switch that is read by diverse CTD receptors, each in its own distinctive manner.

59 BASIC BIOLOGICAL SCIENCES↗

Nop9 recognizes structured and single-stranded RNA elements of preribosomal RNA

Nop9 is an essential factor in the processing of preribosomal RNA. Its absence in yeast is lethal, and defects in the human ortholog are associated with breast cancer, autoimmunity, and learning/language impairment. PUF family RNA-binding proteins are best known for sequence-specific RNA recognition, and most contain eight α-helical repeats that bind to the RNA bases of single-stranded RNA. Nop9 is an unusual member of this family in that it contains eleven repeats and recognizes both RNA structure and sequence. Here we report a crystal structure of Saccharomyces cerevisiae Nop9 in complex with its target RNA within the 20S preribosomal RNA. This structure reveals that Nop9 brings together a carboxy-terminal module recognizing the 5' single-stranded region of the RNA and a bifunctional amino-terminal module recognizing the central double-stranded stem region. We further show that the 3' single-stranded region of the 20S target RNA adds sequence-independent binding energy to the RNA–Nop9 interaction. Both the amino- and carboxy-terminal modules retain the characteristic sequence-specific recognition of PUF proteins, but the amino-terminal module has also evolved a distinct interface, which allows Nop9 to recognize either single-stranded RNA sequences or RNAs with a combination of single-stranded and structured elements.

59 BASIC BIOLOGICAL SCIENCES↗

Propagule Pressure in Microbial Introductions

The use of potentially beneficial microorganisms in agriculture (microbial inoculants) has rapidly accelerated in recent years. For microbial inoculants to be effective as agricultural tools, these organisms must be able to survive and persist in novel environments while not destabilizing the resident community or spilling over into adjacent natural ecosystems. Here, we adapt a macroecological propagule pressure model to a microbial scale and present an experimental approach for testing the role of propagule pressure in microbial inoculant introductions. We experimentally determined the risk-release relationship for an IAA-expressing Pseudomonas simiae inoculant in a model monocot system. We then used this relationship to simulate establishment outcomes under a range of application frequencies (propagule number) and inoculant concentrations (propagule size). Our simulations show that repeated inoculant applications may increase establishment, even when increased inoculant concentration does not alter establishment probabilities. The dataset filed here includes the experimemtal datafile, and a RMarkdown file that includes all the code used in in both the modeling and anaylsis.

agriculture↗

Thermal enhancement cartridge heater modified tritium hydride bed development, Part 2 - Experimental validation of key conceptual design features

The Thermal Enhancement Cartridge Heater Modified (TECH Mod) tritium hydride bed is an interim replacement for the first generation (Gen1) process hydride beds currently in service in the Savannah River Site (SRS) Tritium Facilities. 3 new features are implemented in the TECH Mod hydride bed prototype: internal electric cartridge heaters, porous divider plates, and copper foam discs. These modifications will enhance bed performance and reduce costs by improving bed activation and installation processes, in-bed accountability measurements, end-of-life bed removal, and He-3 recovery. A full-scale hydride bed test station was constructed at the Savannah River National Laboratory (SRNL) in order to evaluate the performance of the prototype TECH Mod hydride bed. Controlled hydrogen (H{sub 2}) absorption/ desorption experiments were conducted to validate that the conceptual design changes have no adverse effects on the gas transfer kinetics or H{sub 2} storage/release properties compared to those of the Gen1 bed. Inert gas expansions before, during, and after H{sub 2} flow tests were used to monitor changes in gas transfer rates with repeated hydriding/de-hydriding of the hydride material. The gas flow rates significantly decreased after initial hydriding of the material; however, minimal changes were observed after repeated cycling. The data presented herein confirm that the TECH Mod hydride bed would be a suitable replacement for the Gen1 bed with the added enhancements expected from the advanced design features. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Linear diffraction grating interferometer with high alignment tolerance and high accuracy

We present an innovative structure of a linear diffraction grating interferometer as a long stroke and nanometer resolution displacement sensor for any linear stage. The principle of this diffractive interferometer is based on the phase information encoded by the {+-}1st order beams diffracted by a holographic grating. Properly interfering these two beams leads to modulation similar to a Doppler frequency shift that can be translated to displacement measurements via phase decoding. A self-compensation structure is developed to improve the alignment tolerance. LightTool analysis shows that this new structure is completely immune to alignment errors of offset, standoff, yaw, and roll. The tolerance of the pitch is also acceptable for most installation conditions. In order to compact the structure and improve the signal quality, a new optical bonding technology by mechanical fixture is presented so that the miniature optics can be permanently bonded together without an air gap in between. For the output waveform signals, a software module is developed for fast real-time pulse counting and phase subdivision. A laser interferometer HP5529A is employed to test the repeatability of the whole system. Experimental data show that within 15 mm travel length, the repeatability is within 15 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional stitching interferometry assisted by a triple-beam interferometer

In this work, we proposed for stitching interferometry to use a triple-beam interferometer to measure both the distance and the tilt for all sub-apertures before the stitching process. The relative piston between two neighboring sub-apertures is then calculated by using the data in the overlapping area. Comparisons are made between our method, and the classical least-squares principle stitching method. Our method can improve the accuracy and repeatability of the classical stitching method when a large number of sub-aperture topographies are taken into account. Our simulations and experiments on flat and spherical mirrors indicate that our proposed method can decrease the influence of the interferometer error from the stitched result. The comparison of stitching system with Fizeau interferometry data is about 2 nm root mean squares and the repeatability is within ± 2.5 nm peak to valley.

47 OTHER INSTRUMENTATION↗