Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega

The gas Cherenkov detectors at NIF and Omega measure several ICF burn characteristics by detecting multi-MeV nuclear γ emissions from the implosion. Of primary interest are γ bang-time (GBT) and burn width defined as the time between initial laser-plasma interaction and peak in the fusion reaction history and the FWHM of the reaction history respectively. To accurately calculate such parameters the collaboration relies on Monte Carlo codes, such as GEANT4 and ACCEPT, for diagnostic properties that cannot be measured directly. This paper describes a series of experiments performed at the High Intensity γ Source (HIγS) facility at Duke University to validate the geometries and material data used in the Monte Carlo simulations. Results published here show that model-driven parameters such as intensity and temporal response can be used with less than 50% uncertainty for all diagnostics and facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of transport models using additive flux minimization technique

A new additive flux minimization technique is proposed for carrying out the verification and validation (V and V) of anomalous transport models. In this approach, the plasma profiles are computed in time dependent predictive simulations in which an additional effective diffusivity is varied. The goal is to obtain an optimal match between the computed and experimental profile. This new technique has several advantages over traditional V and V methods for transport models in tokamaks and takes advantage of uncertainty quantification methods developed by the applied math community. As a demonstration of its efficiency, the technique is applied to the hypothesis that the paleoclassical density transport dominates in the plasma edge region in DIII-D tokamak discharges. A simplified version of the paleoclassical model that utilizes the Spitzer resistivity for the parallel neoclassical resistivity and neglects the trapped particle effects is tested in this paper. It is shown that a contribution to density transport, in addition to the paleoclassical density transport, is needed in order to describe the experimental profiles. It is found that more additional diffusivity is needed at the top of the H-mode pedestal, and almost no additional diffusivity is needed at the pedestal bottom. The implementation of this V and V technique uses the FACETS::Core transport solver and the DAKOTA toolkit for design optimization and uncertainty quantification. The FACETS::Core solver is used for advancing the plasma density profiles. The DAKOTA toolkit is used for the optimization of plasma profiles and the computation of the additional diffusivity that is required for the predicted density profile to match the experimental profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental validation of Mueller-Stokes theory and investigation of the influence of the Cotton-Mouton effect on polarimetry in a magnetized fusion plasma

Mueller-Stokes theory can be used to calculate the polarization evolution of an electromagnetic (EM) wave as it propagates through a magnetized plasma. Historically, the theory has been used to interpret polarimeter signals from systems operating on fusion plasmas. These interpretations have mostly employed approximations of Mueller-Stokes theory in regimes where either the Faraday rotation (FR) or the Cotton-Mouton (CM) effect is dominant. The current paper presents the first systematic comparison of polarimeter measurements with the predictions of full Mueller-Stokes theory where conditions transition smoothly from a FR-dominant (i.e., weak CM effect) plasma to one where the CM effect plays a significant role. A synthetic diagnostic code, based on Mueller-Stokes theory accurately reproduces the trends evident in the experimentally measured polarimeter phase over this entire operating range, thereby validating Mueller-Stokes theory. The synthetic diagnostic code is then used to investigate the influence of the CM effect on polarimetry measurements. As expected, the measurements are well approximated by the FR effect when the CM effect is predicted to be weak. However, the code shows that as the CM effect increases, it can compete with the FR effect in rotating the polarization of the EM-wave. This results in a reduced polarimeter response to the FR effect, just as observed in the experiment. The code also shows if sufficiently large, the CM effect can even reverse the handedness of a wave launched with circular polarization. This helps to understand the surprising experimental observations that the sensitivity to the FR effect can be nearly eliminated at high enough B{sub T} (2.0 T). The results also suggest that the CM effect on the plasma midplane can be exploited to potentially measure magnetic shear in tokamak plasmas. These results establish increased confidence in the use of such a synthetic diagnostic code to guide future polarimetry design and interpret the resultant experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental validation of advanced regulations for superconducting magnet cooling undergoing periodic heat loads

Superconducting magnets used in tokamaks undergo periodic heat load caused by cycling plasma operations inducing AC losses, neutrons fluxes and eddy currents in magnet structures. In the cryogenic system of JT60-SA tokamak, the Auxiliary Cold Box (ACB) distributes helium from the refrigerator to the cryogenic users and in particular to the superconducting magnets. ACB comprises a saturated helium bath with immersed heat exchangers, extracting heat from independent cooling loops. The supercritical helium flow in each cooling loop is driven by a cold circulator. In order to safely operate the refrigerator during plasma pulses, the interface between the ACB and the refrigerator shall be as stable as possible, with well-balanced bath inlet and outlet mass flows during cycling operation. The solution presented in this paper relies on a combination of regulations to smooth pulsed heat loads and to keep a constant refrigeration power during all the cycle. Two smoothing strategies are presented, both regulating the outlet mass flow of the bath: the first one using the bath as a thermal buffer and the second one storing energy in the loop by varying the cold circulator speed. The bath outlet mass flow is also controlled by an immersed resistive heater which enables a constant evaporation rate in the bath when power coming from the loops is decreasing. The refrigeration power is controlled so that the compensating power remains within an acceptable margin. Experimental validation is achieved using the HELIOS facility. This facility running at CEA Grenoble since 2010 is a scaled down model of the ACB bath and Central Solenoid magnet cooling loop of the JT60-SA tokamak. Test results show performances and robustness of the regulations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of plasma shape reconstruction by Cauchy condition surface method in KSTAR

Cauchy Condition Surface (CCS) method is a numerical approach to reconstruct the plasma boundary and calculate the quantities related to plasma shape using the magnetic diagnostics in real time. It has been applied to the KSTAR plasma in order to establish the plasma shape reconstruction with the high elongation of plasma shape and the large effect of eddy currents flowing in the tokamak structures for the first time. For applying the CCS calculation to the KSTAR plasma, the effects by the eddy currents and the ferromagnetic materials on the plasma shape reconstruction are studied. The CCS calculation includes the effect of eddy currents and excludes the magnetic diagnostics, which is expected to be influenced largely by ferromagnetic materials. Calculations have been performed to validate the plasma shape reconstruction in 2012 KSTAR experimental campaign. Comparison between the CCS calculation and non-magnetic measurements revealed that the CCS calculation can reconstruct the accurate plasma shape even with a small I{sub P}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new Gaussian MCTDH program: Implementation and validation on the levels of the water and glycine molecules

We report the main features of a new general implementation of the Gaussian Multi-Configuration Time-Dependent Hartree model. The code allows effective computations of time-dependent phenomena, including calculation of vibronic spectra (in one or more electronic states), relative state populations, etc. Moreover, by expressing the Dirac-Frenkel variational principle in terms of an effective Hamiltonian, we are able to provide a new reliable estimate of the representation error. After validating the code on simple one-dimensional systems, we analyze the harmonic and anharmonic vibrational spectra of water and glycine showing that reliable and converged energy levels can be obtained with reasonable computing resources. The data obtained on water and glycine are compared with results of previous calculations using the vibrational second-order perturbation theory method. Additional features and perspectives are also shortly discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation experiment of a numerically processed millimeter-wave interferometer in a laboratory

We propose a new interferometer system for density profile measurements. This system produces multiple measurement chords by a leaky-wave antenna driven by multiple frequency inputs. The proposed system was validated in laboratory evaluation experiments. We confirmed that the interferometer generates a clear image of a Teflon plate as well as the phase shift corresponding to the plate thickness. In another experiment, we confirmed that quasi-optical mirrors can produce multiple measurement chords; however, the finite spot size of the probe beam degrades the sharpness of the resulting image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative prediction of radio frequency induced local heating derived from measured magnetic field maps in magnetic resonance imaging: A phantom validation at 7 T

Electrical Properties Tomography (EPT) technique utilizes measurable radio frequency (RF) coil induced magnetic fields (B1 fields) in a Magnetic Resonance Imaging (MRI) system to quantitatively reconstruct the local electrical properties (EP) of biological tissues. Information derived from the same data set, e.g., complex numbers of B1 distribution towards electric field calculation, can be used to estimate, on a subject-specific basis, local Specific Absorption Rate (SAR). SAR plays a significant role in RF pulse design for high-field MRI applications, where maximum local tissue heating remains one of the most constraining limits. The purpose of the present work is to investigate the feasibility of such B1-based local SAR estimation, expanding on previously proposed EPT approaches. To this end, B1 calibration was obtained in a gelatin phantom at 7 T with a multi-channel transmit coil, under a particular multi-channel B1-shim setting (B1-shim I). Using this unique set of B1 calibration, local SAR distribution was subsequently predicted for B1-shim I, as well as for another B1-shim setting (B1-shim II), considering a specific set of parameter for a heating MRI protocol consisting of RF pulses plaid at 1% duty cycle. Local SAR results, which could not be directly measured with MRI, were subsequently converted into temperature change which in turn were validated against temperature changes measured by MRI Thermometry based on the proton chemical shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental validation of an 8 element EMAT phased array probe for longitudinal wave generation

Sodium cooled Fast Reactors (SFR) use liquid sodium as a coolant. Liquid sodium being opaque, optical techniques cannot be applied to reactor vessel inspection. This makes it necessary to develop alternative ways of assessing the state of the structures immersed in the medium. Ultrasonic pressure waves are well suited for inspection tasks in this environment, especially using pulsed electromagnetic acoustic transducers (EMAT) that generate the ultrasound directly in the liquid sodium. The work carried out at CEA LIST is aimed at developing phased array EMAT probes conditioned for reactor use. The present work focuses on the experimental validation of a newly manufactured 8 element probe which was designed for beam forming imaging in a liquid sodium environment. A parametric study is carried out to determine the optimal setup of the magnetic assembly used in this probe. First laboratory tests on an aluminium block show that the probe has the required beam steering capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Young's modulus of high-aspect-ratio carbon/carbon nanotube composite microcantilevers by experimental and modeling validation

This paper reports the Young's modulus of a carbon nanotube (CNT)-reinforced carbon/CNT (C/CNT) composite microcantilevers measured by laser Doppler vibrometer and validated by finite element method. Also, the microfabrication process of the high-aspect-ratio C/CNT microcantilever arrays based on silicon micromolding and pyrolysis is presented in detail. With the in-plane natural resonant frequencies of the microcantilevers measured by a laser Doppler vibrometer, a single degree of freedom (SDoF) model based on Euler-Bernoulli (E-B) beam theory is used to calculate the Young's modulus of this composite. To figure out whether this SDoF model can be applied to these composite microcantilevers, the finite element (FE) simulation of these microcantilevers was performed. The Young's modulus of C/CNT composite microcantilevers fabricated by the pyrolysis process at 600 °C is 9391 MPa, and a good agreement between the results from experiments and FE simulation is obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Numerical prediction of fiber orientation in injection-molded short-fiber/thermoplastic composite parts with experimental validation

Numerical prediction of the fiber orientation in the short-glass fiber (GF) reinforced polyamide 6 (PA6) composites with the fiber weight concentration of 30%, 50%, and 70% manufactured by the injection molding process is presented. And the fiber orientation was also directly observed and measured through X-ray computed tomography. During the injection molding process of the short-fiber/thermoplastic composite, the fiber orientation is produced by the flow states and the fiber-fiber interaction. Folgar and Tucker equation is the well known for modeling the fiber orientation in a concentrated suspension. They included into Jeffrey’s equation a diffusive type of term by introducing a phenomenological coefficient to account for the fiber-fiber interaction. Our developed model for the fiber-fiber interaction was proposed by modifying the rotary diffusion term of the Folgar-Tucker equation. This model was presented in a conference paper of the 29{sup th} International Conference of the Polymer Processing Society published by AIP conference proceeding. For modeling fiber interaction, the fiber dynamic simulation was introduced in order to obtain a global fiber interaction coefficient, which is sum function of the fiber concentration, aspect ratio, and angular velocity. The fiber orientation is predicted by using the proposed fiber interaction model incorporated into a computer aided engineering simulation package C-Mold. An experimental program has been carried out in which the fiber orientation distribution has been measured in 100 x 100 x 2 mm injection-molded plate and 100 x 80 x 2 mm injection-molded weld by analyzed with a high resolution 3D X-ray computed tomography system XVA-160α, and calculated by X-ray computed tomography imaging. The numerical prediction shows a good agreement with experimental validation. And the complex fiber orientation in the injection-molded weld was investigated.

42 ENGINEERING↗

Validation of a quantized-current source with 0.2 ppm uncertainty

We report on high-accuracy measurements of quantized current, sourced by a tunable-barrier single-electron pump at frequencies f up to 1 GHz. The measurements were performed with an ultrastable picoammeter instrument, traceable to the Josephson and quantum Hall effects. Current quantization according to I = ef with e being the elementary charge was confirmed at f = 545 MHz with a total relative uncertainty of 0.2 ppm, improving the state of the art by about a factor of 5. The accuracy of a possible future quantum current standard based on single-electron transport was experimentally validated to be better than the best (indirect) realization of the ampere within the present SI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dielectric barrier discharge-based plasma actuator operation in artificial atmospheres for validation of modeling and simulation

We present an experimental case study of time-resolved force production by an aerodynamic plasma actuator immersed in various mixtures of electropositive (N{sub 2}) and electronegative gases (O{sub 2} and SF{sub 6}) at atmospheric pressure using a fixed AC high-voltage input of 16 kV peak amplitude at 200 Hz frequency. We have observed distinct changes in the discharge structures during both negative- and positive-going voltage half-cycles, with corresponding variations in the actuator's force production: a ratio of 4:1 in the impulse produced by the negative-going half-cycle of the discharge among the various gas mixtures we explored, 2:1 in the impulse produced by the positive-going half-cycle, and cases in which the negative-going half-cycle dominates force production (by a ratio of 1.5:1), where the half-cycles produce identical force levels, and where the positive-going half cycle dominates (by a ratio of 1:5). We also present time-resolved experimental evidence for the first time that shows electrons do play a significant role in the momentum coupling to surrounding neutrals during the negative going voltage half-cycle of the N{sub 2} discharge. We show that there is sufficient macroscopic variation in the plasma that the predictions of numerical models at the microscopic level can be validated even though the plasma itself cannot be measured directly on those spatial and temporal scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust validation of approximate 1-matrix functionals with few-electron harmonium atoms

A simple comparison between the exact and approximate correlation components U of the electron-electron repulsion energy of several states of few-electron harmonium atoms with varying confinement strengths provides a stringent validation tool for 1-matrix functionals. The robustness of this tool is clearly demonstrated in a survey of 14 known functionals, which reveals their substandard performance within different electron correlation regimes. Unlike spot-testing that employs dissociation curves of diatomic molecules or more extensive benchmarking against experimental atomization energies of molecules comprising some standard set, the present approach not only uncovers the flaws and patent failures of the functionals but, even more importantly, also allows for pinpointing their root causes. Since the approximate values of U are computed at exact 1-densities, the testing requires minimal programming and thus is particularly suitable for rapid screening of new functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Construction and experimental validation of a simple, compact, resealable, and reliable Vycor{sup ®} superleak assembly for use at low temperatures

A new method of constructing a superleak assembly for use in experiments involving {sup 4}He or {sup 3}He-{sup 4}He mixtures at very low temperatures is described. Superleaks are made of a porous medium with very small pores and channels. Superleaks are often incorporated in thermomechanical pumps, superfluid magnetic pumps, dilution refrigerators, and superfluid helium transfer systems. We used several cylindrical pieces of Vycor, a permeable glass with average pore diameter of 40 Å and porosity of 28%, as a candidate to be used in our superleak assembly. Our design is simple and compact. Our superleak assembly can be disassembled and easily reassembled for reuse. We successfully tested and validated this device at temperatures between 1.4 K and 2.7 K. We experienced no superfluid leaks into the surrounding vacuum. We also report that thermal cycling caused no performance degradation. It is our goal to share the design and construction techniques of this new superleak assembly.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas

To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the D{sub α} spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading Limiting Peak-Power Analysis Techniques with Modern Validation and Uncertainty Quantification for the Advanced Test Reactor

Here, this work demonstrates the acceptability of the 2D deterministic transport code, HELIOS, to replace the legacy diffusion code, PDQ, for computing the peak-power performance parameters of the Advanced Test Reactor (ATR). The 95% Confidence Rule, commonly used in the commercial reactor sector, is explored to develop the so-called “reliability factors” which provide statistical confidence that the peak-power limits within the hottest location along a fuel plate, referred to as the hot-stripe, will not be exceeded. Additionally, an alternative “legacy” methodology was explored that attempts to mimic the exact PDQ analysis process used for defining the peak-power limits. The legacy methodology, involves interpolating power between regions at azimuthal boundaries subtending the regions of interest. In order to apply the 95% Confidence Rule, a statistically significant calculation-to-measurement bias must first be established. Unlike the commercial world where thousands of power observations can be collected every cycle using on-line flux mapping instrumentation, the ATR power distribution must be measured during “depressurized” zero-power measurements using fission wires in polyethylene wands. In 2012, fission wire activation data was collected during a flux run in the Advanced Test Reactor – Critical facility. Also to improve statistical validity, archival data from ATR zero power flux runs from 1977, 1986, and 1994 were digitized from scanned reports and used to create new benchmark models. Borrowing from least-squares adjustment methods commonly used for neutron activation spectroscopy, adjusted fission wire powers were calculated for all four datasets. The mean and standard deviation of the bias between a priori calculated and adjusted wire-powers was then taken as the bias and uncertainty used in the 95% Confidence Rule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of Continuous-Energy ENDF/B-VIII.0 16 O, 56 Fe, and 63,65 Cu Cross Sections for Nuclear Criticality Safety Applications

Recently completed cross-section evaluations sponsored in part by the Nuclear Criticality Safety Program were incorporated into the 2018 release of the ENDF/B-VIII.0 cross-section library. Evaluated isotopes of interest to the nuclear data and criticality safety community include 16 O, 56 Fe, and 63,65 Cu. For performance validation, benchmark models defined in the International Criticality Safety Benchmark Evaluation Project Handbook were selected based on energy-integrated k eff sensitivities to total cross sections of interest and compared with experimental values. Of the 102 benchmark configurations that were utilized, 63 are sensitive to 16 O, 32 sensitive to 63,65 Cu, and 25 sensitive to 56 Fe. Selected benchmarks were modeled in SCALE 6.2.3 Criticality Safety Analysis Sequence (CSAS) continuous-energy Monte Carlo k eff calculations with ENDF/B-VII.1, with a hybrid ENDF/B-VII.1 with ENDF/B-VIII.0 data substituted for individual isotopes of interest, and with ENDF/B-VIII.0. ENDF/B-VIII.0 showed improved agreement with experimental k eff for 56 Fe, 63 Cu, elemental copper, and full library substitution while producing lessened agreement for 16 O and 65 Cu. Furthermore, with full library and isotope-specific ENDF/B-VIII.0 performance, a best-case ENDF library was formed by excluding underperforming isotopes’ ENDF/B-VIII.0 data, reverting 16 O and 65 Cu cross sections to ENDF/B-VII.1. This resulted in the average relative deviation between calculated and experimental data improving from 1.45σ for the ENDF/B-VIII.0 library to 1.32σ for the best-case library, relative to benchmark uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗