Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Resin transfer molding systems and control logic for manufacturing fiber-reinforced composite parts

Presented are manufacturing control systems for fabricating composite-material structures, methods for making/operating such systems, and resin transfer molding techniques for ameliorating race-tracking effects in fiber-reinforced polymer panels. A method for forming a composite-material construction includes confirming, via a system electronic control unit (ECU), that a fiber-based preform is placed in a mold cavity and that opposing mold segments of the molding apparatus are sealed together. A filler, such as a compressible bladder, a cluster of spring-biased pins, or a spray-chopped fiber bed, is introduced into a void between the fiber-based preform and a tool face of one mold segment to thereby eliminate an unwanted resin race track. The system ECU commands a resin pump to inject resin through a primary gate of the molding apparatus and into the mold cavity to thereby impregnate the fiber-based preform with the resin. One or more vents operate to evacuate air from the mold.

Rodgers, William R.↗

New test techniques to evaluate near field effects for supersonic store carriage and separation

Store separation and store carriage drag studies were conducted. A primary purpose is to develop new experimental methods to evaluate near field effects of store separation and levels of store carriage drag associated with a variety of carriage techniques for different store shapes and arrangements. Flow field measurements consisting of surface pressure distributions and vapor screen photographs are used to analyze the variations of the store separation characteristics with cavity geometry. Store carriage drag measurements representative of tangent, semi-submerged, and internal carriage installations are presented and discussed. Results are included from both fully metric models and models with only metric segments (metric pallets) and the relative merits of the two are discussed. Carriage drag measurements for store installations on an aircraft parent body are compared both with prediction methods and with installations on a generic parent body.

Sawyer, Wallace C.↗

Dynamic PID loop control

The Horizontal Test Stand (HTS) SRF Cavity and Cryomodule 1 (CM1) of eight 9-cell, 1.3GHz SRF cavities are operating at Fermilab. For the cryogenic control system, how to hold liquid level constant in the cryostat by regulation of its Joule-Thompson JT-valve is very important after cryostat cool down to 2.0 K. The 72-cell cryostat liquid level response generally takes a long time delay after regulating its JT-valve; therefore, typical PID control loop should result in some cryostat parameter oscillations. This paper presents a type of PID parameter self-optimal and Time-Delay control method used to reduce cryogenic system parameters oscillation.

43 PARTICLE ACCELERATORS↗

Tailoring the optical properties of wide-bandgap based microcavities via metal films

We report on the tuning of the optical properties of II-VI-material-based microcavity samples, which is achieved by depositing Ag films on top of the structures. The micro-reflectivity spectra show a spectral shift of the sample resonance dependent on the metal layer thickness. By comparison of the experimental findings with the theoretical calculations applying the transfer matrix method on a metal-dielectric mirror structure, the influence of the metal layer particularly with regard to its partial oxidation was explored. Tamm plasmon modes are created at the interface between an open cavity with three ZnSe quantum wells and a metal layer on top. When tuning the excitonic emission relative to the mode by changing the sample temperature, an anticrossing of the resonances was observed. This is a clear indication that the strong coupling regime has been achieved in that sample configuration yielding a Rabi splitting of 18.5 meV. These results are promising for the realization of polariton-based optical devices with a rather simple sample configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BDS Thin Film UV Antireflection Laser Damage Competition

UV antireflection coatings are a challenging coating for high power laser applications as exemplified by the use of uncoated Brewster's windows in laser cavities. In order to understand the current laser resistance of UV AR coatings in the industrial and university sectors, a double blind laser damage competition was performed. The coatings have a maximum reflectance of 0.5% at 355 nm at normal incidence. Damage testing will be performed using the raster scan method with a 7.5 ns pulse length on a single testing facility to facilitate direct comparisons. In addition to the laser resistance results, details of deposition processes and coating materials will also be shared.

42 ENGINEERING↗

Localization dynamics in a centrally coupled system

In systems in which interactions couple a central degree of freedom and a bath, one would expect signatures of the bath's phase to be reflected in the dynamics of the central degree of freedom. This has been recently explored in connection with many-body localized baths coupled with a central qubit or a single-cavity mode - systems with growing experimental relevance in various platforms. Such models also have an interesting connection with Floquet many-body localization via quantizing the external drive, although this has been relatively unexplored. Here we adapt the multilayer multiconfigurational time-dependent Hartree (ML-MCTDH) method, a well-known tree tensor network algorithm, to numerically simulate the dynamics of a central degree of freedom, represented by a d-level system (qudit), coupled to a disordered interacting one-dimensional spin bath. ML-MCTDH allows us to reach ≈10 2 lattice sites, a far larger system size than what is feasible with exact diagonalization or kernel polynomial methods. From the intermediate time dynamics, we find a well-defined thermodynamic limit for the qudit dynamics upon appropriate rescaling of the system-bath coupling. The spin system shows similar scaling collapse in the Edward-Anderson spin-glass order parameter or entanglement entropy at relatively short times. At longer timescales, we see slow growth of the entanglement, which may arise from dephasing mechanisms in the localized system or long-range interactions mediated by the central degree of freedom. Similar signs of localization are shown to appear as well with unscaled system-bath coupling.

1-dimensional spin chains↗

A 1.5 T transverse magnetic field in radiotherapy of rectal cancer: Impact on the dose distribution

Purpose: MRI guidance during radiotherapy has the potential to enable more accurate dose delivery, optimizing the balance between local control and treatment related toxicity. However, the presence of a permanent magnetic field influences the dose delivery, especially around air cavities. Here, electrons are able to return to the surface through which they entered the air cavity (electron return effect, ERE) locally resulting in dose hot- and cold-spots. Where RT of rectal cancer patients might benefit from MRI guidance for margin reduction, air cavities in and around the target volume are frequently present. The purpose of this research is to evaluate the impact of the presence of a 1.5 T transverse magnetic field on dose delivery in patients with rectal cancer. Methods: Ten patients treated with 5 × 5 Gy RT having large changes in pelvic air content were selected out of a cohort of 33 patients. On the planning CT, a 1.5 T, 6 MV, 7-field intensity modulated radiotherapy (IMRT) plan was created. This plan was subsequently recalculated on daily CT scans. For each daily CT, the CTV V{sub 95%} and V{sub 107%} and bowel area V{sub 5Gy}, V{sub 10Gy}, V{sub 15Gy}, V{sub 20Gy}, and V{sub 25Gy} were calculated to evaluate the changes in dose distribution from fraction to fraction. For comparison, the authors repeated this procedure for the 0 T situation. To study the effect of changing air cavities separate from other anatomical changes, the authors also generated artificial air cavities in the CTV of one patient (2 and 5 cm diameter), in the high dose gradient region (2 cm), and in the low dose area (2 cm). Treatment plans were optimized without and with each simulated air cavity. For appearing and disappearing air cavities, the CTV V{sub 95%} and V{sub 107%} were evaluated. The authors also evaluated the ERE separate from attenuation changes locally around appearing gas pockets. Results: For the ten patients, at 1.5 T, the V{sub 95%} was influenced by both appearing and disappearing air, and dropped to <98% in 2 out of 50 fractions due a disappearing air cavity of 150 cm{sup 3}. V{sub 95%} differences between 0 and 1.5 T were all within 2%. The V{sub 107%} was below 1% in 46 out of 50 fractions, and increased to 3% in the remaining fractions due to appearing air of around 120 cm{sup 3}. For comparison, V{sub 107%} was <1% at 0 T for all fractions. In the bowel area, the V{sub 15Gy} varied strongest from fraction to fraction, but differences between 1.5 and 0 T were minimal with an average difference of 2.3 cm{sup 3} (SD = 18.7 cm{sup 3}, p = 0.38). For the simulated air cavities, the ERE resulted in cold-spots maximally 5% lower than prescribed and hot-spots maximally 6% higher than prescribed. Conclusions: The presence of a 1.5 T magnetic field has an impact on the dose distribution when the air content changes of within a few percent in these selected rectal cancer patients. The authors consider this influence of the transverse magnetic field on the dose distribution in IMRT for rectal cancer patients clinically acceptable.

60 APPLIED LIFE SCIENCES↗

Hydrodynamic instabilities and heat transfer characteristics in the duct flow of a fluid in the supercritical thermodynamic regime

The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.

42 ENGINEERING↗

Prediction of p K a s of Late Transition‐Metal Hydrides via a QM/QM Approach

Three implicit solvation models, the conductor‐like polarizable continuum model (C‐PCM), the conductor‐like screening model (COSMO), and universal implicit solvent model (SMD), combined with a hybrid two layer QM/QM approach (ONIOM), were utilized to calculate the p K a values, using a direct thermodynamic scheme, of a set of Group 10 transition metal (TM) hydrides in acetonitrile. To obtain the optimal combination of quantum methods for ONIOM calculations with implicit solvation models, the influence of factors, such as the choice of density functional and basis set, the atomic radii used to build a cavity in the solvent, and the size of the model system in an ONIOM scheme, was examined. Additionally, the impact of Grimme's empirical dispersion correction and exact exchange was also investigated. The results were calibrated by experimental data. This investigation provides insight about effective models for the prediction of thermodynamic properties of TM‐containing complexes with bulky ligands. © 2019 Wiley Periodicals, Inc.

Patel, Prajay↗

A New Method of an Axial Puncture Approach for Draining Loculated Pleural Effusions

Purpose: The authors devised a new method of an axial puncture approach through the pulmonary apex (PA) for percutaneous catheter drainage (PCD) of loculated fluid collections extending to the PA. The purpose of this report is to introduce the new procedure. Methods: Percutaneous catheter drainage by the axial puncture approach was performed in two patients with limited supine position and loculated pleural fluid collection in the posteromedial part of thoracic cavity. Results: The procedures succeeded in two patients without difficulties while keeping them in a supine position, even if the loculated fluids exist in the posterior side of thoracic cavity. Conclusions: Percutaneous catheter drainage by the axial puncture approach is particularly effective in patients with limited supine positions and loculated pleural fluid collection in the posteromedial part of thoracic cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating Fiducial Markers for Image-Guided Radiation Therapy for Accelerated Partial Breast Irradiation in Early-Stage Breast Cancer

Purpose: Image-guided radiation therapy (IGRT) may be beneficial for accelerated partial breast irradiation (APBI). The goal was to validate the use of intraparenchymal textured gold fiducials in patients receiving APBI. Methods and Materials: Twenty-six patients were enrolled on this prospective study that had three or four textured gold intraparenchymal fiducials placed at the periphery of the lumpectomy cavity and were treated with three-dimensional (3D) conformal APBI. Free-breathing four-dimensional computed tomography image sets were obtained pre- and posttreatment, as were daily online megavoltage (MV) orthogonal images. Intrafraction motion, variations in respiratory motion, and fiducial marker migration were calculated using the 3D coordinates of individual fiducials and a calculated center of mass (COM) of the fiducials. We also compared the relative position of the fiducial COM with the geometric center of the seroma. Results: There was less than 1 mm of intrafraction respiratory motion, variation in respiratory motion, or fiducial marker migration. The change in seroma position relative to the fiducial COM was 1 mm {+-} 1 mm. The average position of the geometric seroma relative to the fiducial COM pretreatment compared with posttreatment was 1 mm {+-} 1 mm. The largest daily variation in displacement when using bony landmark was in the anteroposterior direction and two standard deviations (SD) of this variation was 10 mm. The average variation in daily separation between the fiducial pairs from daily MV images was 3 mm {+-} 3 mm therefore 2 SD is 6 mm. Conclusion: Fiducial markers are stable throughout the course of APBI. Planning target volume margins when using bony landmarks should be 10 mm and can be reduced to 6 mm if using fiducials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Autocorrelation and Multifractal Detrended Fluctuation Analyses Reveal Superdiffusive Mass Transport in Solvent-Filled Nanoporous Media

Fluorescence fluctuation spectroscopy experiments were conducted to better understand the complex mass transport dynamics of organic molecules in liquid-filled nanoporous media. Anodic aluminum oxide (AAO) membranes incorporating 10 and 20 nm diameter cylindrical pores were employed as model materials. Nile red (NR) dye was used as a fluorescent tracer. The dye was dissolved separately in ethanol and toluene at a concentration of 20 nM and used to fill the membrane nanopores. Confocal fluorescence microscopy was employed to capture photon intensity time series data reflecting apparent diffusion of the dye within the pores. Autocorrelation of these data revealed that NR diffusion within the membranes occurred over a broad range of time scales. The autocorrelation decays were fit to a model for one-dimensional diffusion incorporating both fast and slow components having apparent diffusion coefficients, D f and D s , differing by a factor of ∼100. The fast mechanism was attributed to hindered bulk-like diffusion in the central pore cavity, while slow diffusion likely involved absorption of the dye to the pore surfaces. Unfortunately, important evidence of diffusion anomalies is lost in the broad autocorrelation decays obtained. The method of multifractal detrended fluctuation analysis (MF-DFA) was applied to the same data as a means to overcome this limitation. MF-DFA revealed that time series acquired from within the nanopores were multifractal and exhibited evidence of anomalous superdiffusion, likely resulting from the participation of a desorption-mediated diffusion mechanism. Monte Carlo simulations of time series modeling desorption-mediated diffusion in cylindrical nanopores provided support for this assignment. Here, the new knowledge gained affords an improved understanding of hydrocarbon dynamics within nanoporous oil and gas shales.

Diffusion↗

Optical and mechanical mode tuning in an optomechanical crystal with light-induced thermal effects

We report on the modification of the optical and mechanical properties of a silicon 1D optomechanical crystal cavity due to thermo-optic effects in a high phonon/photon population regime. The cavity heats up due to light absorption in a way that shifts the optical modes towards longer wavelengths and the mechanical modes to lower frequencies. By combining the experimental optical results with finite-difference time-domain simulations, we establish a direct relation between the observed wavelength drift and the actual effective temperature increase of the cavity. By assuming that the Young's modulus decreases accordingly to the temperature increase, we find a good agreement between the mechanical mode drift predicted using a finite element method and the experimental one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trapping of a microsphere pendulum resonator in an optical potential

We propose a method to spatially confine or corral the movements of a micropendulum via the optical forces produced by two simultaneously excited optical modes of a photonic molecule comprising two microspherical cavities. We discuss how the cavity-enhanced optical force generated in the photonic molecule can create an optomechanical potential of about 10 eV deep and 30 pm wide, which can be used to trap the pendulum at any given equilibrium position by a simple choice of laser frequencies. This result presents opportunities for very precise all-optical self-alignment of microsystems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery

Purpose: In external-beam radiation therapy, existing on-board x-ray imaging chains orthogonal to the delivery beam cannot recover 3D target trajectories from a single view in real-time. This limits their utility for real-time motion management concurrent with beam delivery. To address this limitation, the authors propose a novel concept for on-board imaging based on the inverse-geometry Scanning-Beam Digital X-ray (SBDX) system and evaluate its feasibility for single-view 3D intradelivery fiducial tracking. Methods: A chest phantom comprising a posterior wall, a central lung volume, and an anterior wall was constructed. Two fiducials were placed along the mediastinal ridge between the lung cavities: a 1.5 mm diameter steel sphere superiorly and a gold cylinder (2.6 mm length x 0.9 mm diameter) inferiorly. The phantom was placed on a linear motion stage that moved sinusoidally. Fiducial motion was along the source-detector (z) axis of the SBDX system with {+-}10 mm amplitude and a programmed period of either 3.5 s or 5 s. The SBDX system was operated at 15 frames per second, 100 kVp, providing good apparent conspicuity of the fiducials. With the stage moving, detector data were acquired and subsequently reconstructed into 15 planes with a 12 mm plane-to-plane spacing using digital tomosynthesis. A tracking algorithm was applied to the image planes for each temporal frame to determine the position of each fiducial in (x,y,z)-space versus time. A 3D time-sinusoidal motion model was fit to the measured 3D coordinates and root mean square (RMS) deviations about the fitted trajectory were calculated. Results: Tracked motion was sinusoidal and primarily along the source-detector (z) axis. The RMS deviation of the tracked z-coordinate ranged from 0.53 to 0.71 mm. The motion amplitude derived from the model fit agreed with the programmed amplitude to within 0.28 mm for the steel sphere and within -0.77 mm for the gold seed. The model fit periods agreed with the programmed periods to within 7%. Conclusions: Three dimensional fiducial tracking with approximately 1 mm or better accuracy and precision appears to be feasible with SBDX, supporting its use to guide radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-76: Incorporation of Ultrasound Elastography in Target Volume Delineation for Partial Breast Radiotherapy Planning: A Comparative Study

Purpose: There is substantial observer variability in the delineation of target volumes for post-surgical partial breast radiotherapy because the tumour bed has poor x-ray contrast. This variability may result in substantial variations in planned dose distribution. Ultrasound elastography (USE) has an ability to detect mechanical discontinuities and therefore, the potential to image the scar and distortion in breast tissue architecture. The goal of this study was to compare USE techniques: strain elastography (SE), shear wave elastography (SWE) and acoustic radiation force impulse (ARFI) imaging using phantoms that simulate features of the tumour bed, for the purpose of incorporating USE in breast radiotherapy planning. Methods: Three gelatine-based phantoms (10% w/v) containing: a stiff inclusion (gelatine 16% w/v) with adhered boundaries, a stiff inclusion (gelatine 16% w/v) with mobile boundaries and fluid cavity inclusion (to mimic seroma), were constructed and used to investigate the USE techniques. The accuracy of the elastography techniques was quantified by comparing the imaged inclusion with the modelled ground-truth using the Dice similarity coefficient (DSC). For two regions of interest (ROI), the DSC measures their spatial overlap. Ground-truth ROIs were modelled using geometrical measurements from B-mode images. Results: The phantoms simulating stiff scar tissue with adhered and mobile boundaries and seroma were successfully developed and imaged using SE and SWE. The edges of the stiff inclusions were more clearly visible in SE than in SWE. Subsequently, for all these phantoms the measured DSCs were found to be higher for SE (DSCs: 0.91–0.97) than SWE (DSCs: 0.68–0.79) with an average relative difference of 23%. In the case of seroma phantom, DSC values for SE and SWE were similar. Conclusion: This study presents a first attempt to identify the most suitable elastography technique for use in breast radiotherapy planning. Further analysis will include comparison of ARFI with SE and SWE. This work is supported by the EPSRC Platform Grant, reference number EP/H046526/1.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-05: Analysis of Dosimetric Characteristics in Two Leaf Motion Calculator Algorithms for Sliding Window IMRT

Purpose: The Smart leaf motion calculator (SLMC) in Eclipse treatment planning system is an advanced fluence delivery modeling algorithm as it takes into account fine MLC features including inter-leaf leakage, rounded leaf tips, non-uniform leaf thickness, and the spindle cavity etc. In this study, SLMC and traditional Varian LMC (VLMC) algorithms were investigated, for the first time, in dosimetric characteristics and delivery accuracy of sliding window (SW) IMRT. Methods: The SW IMRT plans of 51 cancer cases were included to evaluate dosimetric characteristics and dose delivery accuracy from leaf motion calculated by SLMC and VLMC, respectively. All plans were delivered using a Varian TrueBeam Linac. The DVH and MUs of the plans were analyzed. Three patient specific QA tools - independent dose calculation software IMSure, Delta4 phantom, and EPID portal dosimetry were also used to measure the delivered dose distribution. Results: Significant differences in the MUs were observed between the two LMCs (p≤0.001).Gamma analysis shows an excellent agreement between the planned dose distribution calculated by both LMC algorithms and delivered dose distribution measured by three QA tools in all plans at 3%/3 mm, leading to a mean pass rate exceeding 97%. The mean fraction of pixels with gamma < 1 of SLMC is slightly lower than that of VLMC in the IMSure and Delta4 results, but higher in portal dosimetry (the highest spatial resolution), especially in complex cases such as nasopharynx. Conclusion: The study suggests that the two LMCs generates the similar target coverage and sparing patterns of critical structures. However, SLMC is modestly more accurate than VLMC in modeling advanced MLC features, which may lead to a more accurate dose delivery in SW IMRT. Current clinical QA tools might not be specific enough to differentiate the dosimetric discrepancies at the millimeter level calculated by these two LMC algorithms. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

High Power S-Band Vacuum Dry Loads for SLAC Linac

In the beginning of LCLS-1 commission era, an unstable termination mode of the residual RF power on all vacuum dry loads of the SLAC linac was found. The S-Band loads on the current SLAC linac RF system were designed, in some cases, 50+ years ago to terminate stably only 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber. The technology of the load design was based on a old flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the RF power sources dramatically increased from 24 MW peak klystrons to 240 MW peak (with new klystrons and SLED cavities). As a result, the residual RF power on the loads was increased accordingly. The original RF loads were overstressed and cannot stably terminate the residual RF power in the present RF linac layout.

43 PARTICLE ACCELERATORS↗