Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11275105). Thanks for the support from Accuray Corp.

60 APPLIED LIFE SCIENCES↗

Monte Carlo calculation and verification of the geometrical factors for the NPDGamma experiment

The NPDGamma experiment measures the parity-violating asymmetry in gamma-ray emission in the capture of polarized neutrons on liquid parahydrogen. The sensitivity to the asymmetry for each detector in the array is used as a parameter in the extraction of the physics asymmetry from the measured data. The detector array is approximately cylindrically symmetric around the target and a step-wise sinusoidal function has been used for the sensitivity in the previous iteration of the NPDGamma experiment, but deviations from cylindrical symmetry necessitate the use of a Monte Carlo model to determine corrections to the geometrical factors. For the calculations, source code modifications to MCNPX were done in order to calculate the sensitivity of each cesium iodide detector to the physics asymmetry. We describe the MCNPX model and results from calculations and how the results are validated through measurement of the parity violating asymmetry of gamma-rays from neutron capture on chlorine.

Grammer, K. B.↗

Parallel Environment for the Creation of Stochastics 1.0

PECOS is a computational library for creating and manipulating realizations of stochastic quantities, including scalar uncertain variables, random fields, and stochastic processes. It offers a unified interface to univariate and multivariate polynomial approximations using either orthogonal or interpolation polynomials; numerical integration drivers for Latin hypercube sampling, quadrature, cubature, and sparse grids; and fast Fourier transforms using third party libraries. The PECOS core also offers statistical utilities and transformations between various representations of stochastic uncertainty. PECOS provides a C++ API through which users can generate and transform realizations of stochastic quantities. It is currently used by Sandia's DAKOTA, Stokhos, and Encore software packages for uncertainty quantification and verification. PECOS generates random sample sets and multi-dimensional integration grids, typically used in forward propagation of scalar uncertainty in computational models (uncertainty quantification (UQ)). PECOS also generates samples of random fields (RFs) and stochastic processes (SPs) from a set of user-defined power spectral densities (PSDs). The RF/SP may be either Gaussian or non-Gaussian and either stationary or nonstationary, and the resulting sample is intended for run-time query by parallel finite element simulation codes. Finally, PECOS supports nonlinear transformations of random variables via the Nataf transformation and extensions.

Field Jr, Richard↗

Tuning and Verification of an Internal Flooding Model for Dynamic PRA

In probabilistic risk assessment (PRA), the likelihoods and consequences of basic events are combined to determine possible system level outcomes and the likelihood of each outcome given an initial event. Both the consequences and likelihoods of basic events may be informed by the use of mathematical models or experimental data regarding the phenomena of interest. In either case, the impact of uncertainties on the results need to be evaluated. If a model is used to predict the evolution of an initiating event, uncertainty quantification can be computationally challenging for complex phenomena with many epistemic (e.g., model) uncertainties. In this work, a reduced order model is introduced for the flooding analysis of a multi-room building at a nuclear power plant under uncertainties which can require long run times using high fidelity computer models. The reduced order model focuses on macro-level transfer of water between rooms and tracks the water level within each room. In order to verify the model's fidelity, its results for the phenomena involved in a scenario of interest are compared to those of a computational fluid dynamics (CFD) code, which are taken to represent reality. This work does not focus on the overall fidelity of the flooding model, as the goal of the project for which it was developed is to develop a methodology rather than to analyze a particular case. The focus instead is on the tunability and verifiability of the reduced order model for relevant physical measures. In analyzing a particular case, the model may be required to incorporate more realistic description of phenomena; however, the procedure described in this work may be used to verify its performance as well. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation

Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose volume histograms (DVHs) for single-shot irradiations of the Gamma Knife (GK) unit were used to investigate the effects of the presence of inhomogeneities on 3D dose distribution. The head phantom was a custom-built 16 cm diameter Plexiglas sphere. Inside the phantom, there is a cubic cutout for inserting the gel vials and another cutout for inserting the inhomogeneities. Following irradiation with the GK unit, the polymer gel phantoms were scanned with a 1.5 T MRI scanner. Comparing the results of measurement in homogeneous and heterogeneous phantoms revealed that inserting inhomogeneities inside the homogeneous phantom did not cause considerable disturbances on dose distribution in irradiation with 8 mm collimator within low isodose levels (<50%), which is essential for the dose sparing of sensitive structures. The results of simulation for homogeneous and inhomogeneous phantoms in irradiation with 18 mm collimator of the GK unit showed 23.24% difference in DVH within 90%-100% relative isodose level and also revealed that a significant part of the target (28.56%) received relative doses higher than the maximum dose, which exceeds the acceptance criterion (5%). Based on these results it is concluded that the presence of inhomogeneities inside the phantom can cause considerable errors in dose calculation within high isodose levels with respect to LGP prediction which assumes that the target is a homogeneous material. Moreover, it is demonstrated that the applied MC code is an accurate and stand-alone tool for 3D evaluation of dose distribution in irradiation with the GK unit, which can provide important, 3D plan evaluation criteria used in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

Study of applied magnetic field magnetoplasmadynamic thrusters with particle-in-cell code with Monte Carlo collision. I. Computation methods and physical processes

A two-dimensional axisymmetric electromagnetic particle-in-cell code with Monte Carlo collision conditions has been developed for an applied-field magnetoplasmadynamic thruster simulation. This theoretical approach establishes a particle acceleration model to investigate the microscopic and macroscopic characteristics of particles. This new simulation code was used to study the physical processes associated with applied magnetic fields. In this paper (I), detail of the computation procedure and results of predictions of local plasma and field properties are presented. The numerical model was applied to the configuration of a NASA Lewis Research Center 100-kW magnetoplasmadynamic thruster which has well documented experimental results. The applied magnetic field strength was varied from 0 to 0.12 T, and the effects on thrust were calculated as a basis for verification of the theoretical approach. With this confirmation, the changes in the distributions of ion density, velocity, and temperature throughout the acceleration region related to the applied magnetic fields were investigated. Using these results, the effects of applied field on physical processes in the thruster discharge region could be represented in detail, and those results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm{sup 3} sized ion chambers covering 11×11 cm{sup 2}, which spacing is 2.5 mm in the central 5.5×5.5 cm{sup 2}, dedicated mainly in principle, in conjunction with Octavius 4D (PTW), to IMRT, VMAT, SBRT verifications. Verisoft software that allows for 3D and planar analysis has been used to evaluate the results. Applicators were located on the surface of the array. To verify the SID, measurements corresponding to the reference value, SID ± 1 mm and SID ± 2 mm were acquired (integration time was fixed in order to discard the influence of the source entrance/exit). Once SID was determined, standard protocol treatments corresponding to 3 Gy and 7 Gy were acquired in order to establish typical patient dose distribution. Results: The method is fast and sensitive. The SID obtained was 1321 mm which is the nominal value included in the applicator manual. For example at 1319 mm an asymmetry of ±8% with respect to the central value was measured, along with a central deviation of −4% referred to 1321 mm. Conclusion: A practical method for the commissioning and QA of Valencia applicators has been described. It has been shown that it is an efficient and accurate tool for these purposes as well as for the verification of the absolute output constancy.

60 APPLIED LIFE SCIENCES↗

The Source Physics Experiment (SPE) Science Plan (Version 2.4c)

The Source Physics Experiment (SPE) series is a long-term NNSA research and development effort designed to improve U.S. arms control and nuclear nonproliferation verification and monitoring capabilities. The findings from the SPE will advance the United States’ nuclear explosion monitoring capabilities, particularly with respect to detection, discrimination and determination of yields associated with small nuclear explosions that can be lost amid the noisy seismo-acoustic background from other sources. The data generated from the SPE, a series of well-designed and recorded chemical explosions, will contribute to the development and validation of first-principles explosive source generated seismo-acoustic modeling codes. These codes will then facilitate the update of semi-empirical methods, currently based on historic test site data, such that key explosion observables can be reproduced, thus improving confidence in nuclear test monitoring in new areas and/or under novel emplacement conditions. The overall SPE project is comprised of both the development of the new explosion simulation codes and the chemical explosion test series. The chemical explosion test series will generate the empirical data required to both develop and validate the new simulation codes.

58 GEOSCIENCES↗

Data Evaluation of Actinide Cross Sections: 230 Th and 231 Th

A new evaluation of the ENDL cross section set for Thorium (Z=90) is developed using the TALYS statistical model cross section code. The primary goal of this effort is to produce an evaluation that attempts to match as closely as possible fission cross sections developed through surrogate reaction techniques on actinide targets 230 Th and 231 Th. This evaluation effort and the processing needed to render its results into data libraries is a necessary step in making the efforts of nuclear experimentalists useful to the broad community of researchers engaged in simulations of nuclear fusion for basic and applied science. Another aspect, verification and validation against various AGEX experiments, is also presented. The end-product is an updated library that includes the latest measurements of fission cross sections for comparison against those measured via traditional techniques. All the steps in the evaluation, processing, validation and verification, and library release are described in the following sections. For completeness, the appendix contains all the parameters used in the TALYS cross section evaluation for neutrons incident on 230 Th and 231 Th.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Source Physics Experiment (SPE) Science Plan

The Source Physics Experiment (SPE) series is a long-term NNSA research and development effort designed to improve U.S. arms control and nuclear nonproliferation verification and monitoring capabilities. The findings from the SPE will advance the United States’ nuclear explosion monitoring capabilities, particularly with respect to detection, discrimination and determination of yields associated with small nuclear explosions that can be lost amid the noisy seismo-acoustic background from other sources. The data generated from the SPE, a series of well-designed and recorded chemical explosions, will contribute to the development and validation of first-principles explosive source generated seismo-acoustic modeling codes. These codes will then facilitate the update of semi-empirical methods, currently based on historic test site data, such that key explosion observables can be reproduced, thus improving confidence in nuclear test monitoring in new areas and/or under novel emplacement conditions. The overall SPE project is comprised of both the development of the new explosion simulation codes and the chemical explosion test series. The chemical explosion test series will generate the empirical data required to both develop and validate the new simulation codes.

58 GEOSCIENCES↗

Verification and validation of residual stresses in composite structures

Process-induced residual stresses occur in composite structures composed of dissimilar materials. As these residual stresses could result in fracture, their consideration when designing composite parts is necessary. However, the experimental determination of residual stresses in prototype parts can be time and cost prohibitive. Alternatively, it is possible for computational tools to predict potential residual stresses. Therefore, the objectives of the presented work are to demonstrate an efficient method for simulating residual stresses in composite parts, as well as the potential value of statistical methods during analyses for which material properties are unknown. Specifically, a simplified residual stress modeling approach is implemented within Sandia National Laboratories’ SIERRA/SolidMechanics code. Concurrent with the model development, bi-material composite structures are designed and manufactured to exhibit significant residual stresses. Then, the presented modeling approach is rigorously verified and validated through simulations of the bi-material composite structures’ manufacturing processes, including a mesh convergence study, sensitivity analysis, and uncertainty quantification. The simulations’ final results show adequate agreement with the experimental measurements, indicating the validity of a simple modeling approach, as well as a necessity for the inclusion of material parameter uncertainty in the final residual stress predictions.

42 ENGINEERING↗

Standards, dissemination, and best practices in systems biology

In this study, the reproducibility of scientific research is crucial to the success of the scientific method. Here, we review the current best practices when publishing mechanistic models in systems biology. We recommend, where possible, to use software engineering strategies such as testing, verification, validation, documentation, versioning, iterative development, and continuous integration. In addition, adhering to the Findable, Accessible, Interoperable, and Reusable modeling principles allows other scientists to collaborate and build off of each other’s work. Existing standards such as Systems Biology Markup Language, CellML, or Simulation Experiment Description Markup Language can greatly improve the likelihood that a published model is reproducible, especially if such models are deposited in well-established model repositories. Where models are published in executable programming languages, the source code and their data should be published as open-source in public code repositories together with any documentation and testing code. For complex models, we recommend container-based solutions where any software dependencies and the run-time context can be easily replicated.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Neutron Energy Spectral Signatures for Passive Monitoring of Spent Nuclear Fuels in Dry Cask Storage

Demand for spent nuclear fuel dry casks as an interim storage solution has increased globally and the IAEA has expressed a need for robust safeguards and verification technologies for ensuring the continuity of knowledge and the integrity of radioactive materials inside spent fuel casks. Existing research has been focusing on “fingerprinting” casks based on count rate statistics to represent radiation emission signatures. The current research aims to expand to include neutron energy spectral information as part of the fuel characteristics. First, spent fuel composition data are taken from the Next Generation Safeguards Initiative Spent Fuel Libraries, representative for Westinghouse 17 x 17 PWR assemblies. The ORIGEN-S code then calculates the spontaneous fission and (α,n) emissions for individual fuel rods, followed by detailed MCNP simulations of neutrons transported through the fuel assemblies. A comprehensive database of neutron energy spectral profiles is to be constructed, with different enrichment, burn-up, and cooling time conditions. The end goal is to utilize the computational spent fuel library, predictive algorithm, and a pressurized 4 He scintillator to verify the spent fuel assemblies inside a cask. This work identifies neutron spectral signatures that correlate with the cooling time of spent fuel. Both the total and relative contributions from spontaneous fission and (α,n) change noticeably with respect to cooling time, due to the relatively short half-life (18 years) of the major neutron source 244 Cm. Identification of this and other neutron spectral signatures allows the characterization of spent nuclear fuels in dry cask storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fission Product Transport in TRISO Particles and Pebbles

This document demonstrates completion of the goals described in the technical narrative of the FOA project titled: ”Modeling and Simulation Development Pathways to Accelerating KP-FHR Licensing” regarding fission product transport in the Kairos-proposed fuel pebble by INL and Kairos Power. Showcased in this report are code developments and simulations in BISON that extend the state of the art in computation and understanding of fission product transport in a TRISO fuel particle and pebble. These enhancements lay the foundation for making predictions of fission product transport that can be used as input in the fuel licensing process. This was achieved by installing existing fuel material models originally used in PARFUME, developing a new failure probability method that is efficient and multi-dimensional, employing material homogenization, and expanding verification and validation simulations to demonstrate the efficacy of the work. All this work is leveraged to spotlight the main deliverable; a three-dimensional model and corresponding demonstration simulation of a pebble, which will serve as the starting point for models used to predict fission product release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Python Script to Read MCNP6.3 Surface-Source Files

This report provides a Python script to read an MCNP ® surface source file created with the SSW card with SYM = 0 (i.e., the default symmetry treatment). For background: the general format of an MCNP surface-source file is described in; however, that document did not provide coding and/or a tool to interrogate such files. The current format will not be given in this document other than through the record-read statements necessary for the script to function. The reader capability in this report is augmented with the ability to directly write a couple demonstrative outputs: 1. A comma-separated value (CSV) file containing particle phase-space state information and 2. A Matplotlib histogram of the energy distribution of the particles. This report also describes accompanying verification work that shows the script performing as required with MCNP6.2, MCNP6.3, and (expected) MCNP6.4 surface-source files. However, users of the enclosed script must still verify that the script is behaving correctly for their own work.

97 MATHEMATICS AND COMPUTING↗