Time and spectrum-resolving multiphoton correlator for 300–900 nm

We demonstrate a single-photon sensitive spectrometer in the visible range, which allows us to perform time-resolved and multi-photon spectral correlation measurements at room temperature. It is based on a monochromator composed of two gratings, collimation optics, and an array of single photon avalanche diodes. The time resolution can reach 110 ps and the spectral resolution is 2 nm/pixel, limited by the design of the monochromator. This technique can easily be combined with commercial monochromators and can be useful for joint spectrum measurements of two photons emitted in the process of parametric down conversion, as well as time-resolved spectrum measurements in optical coherence tomography or medical physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tomographic analysis of the nonthermal x-ray bursts during disruption instability in the T-10 tokamak

Non-thermal x-ray radiation (E{sub γ} up to 150 keV) is measured in the T-10 tokamaks during disruption instability using two sets of CdTe detectors (10 vertical and 7 horizontal view detectors). Special narrow cupper tubes collimators with lead screening and CdTe detectors integrated with amplifiers inside metallic containers provides enhanced spatial resolution of the system (r ~ 3 cm) and assures protection from the parasitic hard x-ray (E{sub γ} up to 1.5 MeV) and electromagnetic loads during disruption. Spatial localization of the nonthermal x-ray emissivity is reconstructed using tomographic Cormack technique with SVD matrix inversion. Analysis indicated appearance of an intensive non-thermal x-ray bursts during initial stage of the disruptions at high density. The bursts are characterized by repetitive spikes (2–3 kHz) of the x-ray emissivity from the plasma core area. Analysis indicated that the spikes can be connected with acceleration of the non-thermal electrons in enhanced longitudinal electric fields induced during energy quench at the disruption instability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism{sup 1}. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

43 PARTICLE ACCELERATORS↗

Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High intensity multi beam design of SANS instrument for Dhruva reactor

A new and versatile design of Small Angle Neutron Scattering (SANS) instrument based on utilization of multi-beam is presented. The multi-pinholes and multi-slits as SANS collimator for medium flux Dhruva rearctor have been proposed and their designs have been validated using McStas simulations. Various instrument configurations to achieve different minimum wave vector transfers in scattering experiments are envisioned. These options enable smooth access to minimum wave vector transfers as low as ~ 6×10{sup −4} Å{sup −1} with a significant improvement in neutron intensity, allowing faster measurements. Such angularly well defined and intense neutron beam will allow faster SANS studies of agglomerates larger than few tens of nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NSLS-II beamline scattered gas bremsstrahlung radiation shielding calculation

National Synchrotron Light Source II (NSLS-II) is a new state-of-the-art 3rd generation synchrotron. The NSLS-II facility is shielded up to 3 GeV electron beam energy at 500 mA. When the gas bremsstrahlung (GB) from the storage ring is scattered by the beamline components in the first optical enclosure (FOE), the scattered radiation will pose additional radiation hazard (bypassing primary GB collimators and stops) and challenge the FOE shielding. The scattered GB radiation hazard can be mitigated by supplementary shielding or with an exclusion zone downstream of the FOE.

43 PARTICLE ACCELERATORS↗

Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

43 PARTICLE ACCELERATORS↗

Development of the radial neutron camera system for the HL-2A tokamak

A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasma have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard {sup 235}U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high performance neutron powder diffractometer at 3 MW Triga Mark-II research reactor in Bangladesh

A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fiber-coupled displacement measuring interferometer for determination of the posture of a reflective surface

A fiber-coupled displacement measuring interferometer capable of determining of the posture of a reflective surface of a measuring mirror is proposed. The newly constructed instrument combines fiber-coupled displacement and angular measurement technologies. The proposed interferometer has advantages of both the fiber-coupled and the spatially beam-separated interferometer. A portable dual-position sensitive detector (PSD)-based unit within this proposed interferometer measures the parallelism of the two source beams to guide the fiber-coupling adjustment. The portable dual PSD-based unit measures not only the pitch and yaw of the retro-reflector but also measures the posture of the reflective surface. The experimental results of displacement calibration show that the deviations between the proposed interferometer and a reference one, Agilent 5530, at two different common beam directions are both less than ±35 nm, thus verifying the effectiveness of the beam parallelism measurement. The experimental results of angular calibration show that deviations of pitch and yaw with the auto-collimator (as a reference) are less than ±2 arc sec, thus proving the proposed interferometer’s effectiveness for determination of the posture of a reflective surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements

In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell—to study ionization of atoms and molecules by electron impact—is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of harmonics and supercontinuum in nematic liquid crystals

Nonlinear optical properties of nematic liquid crystals (NLC) have been investigated. A technique for efficient laser frequency conversion in a microscopic NLC volume deposited on an optical fibre end face is experimentally demonstrated. An efficient design of a compact NLC-based IR frequency converter with a fibre input and achromatic collimator is proposed and implemented. Simultaneous generation of the second and third harmonics is obtained for the first time under pumping NLC by a 1.56-mm femtosecond fibre laser. The second-harmonic generation efficiency is measured to be about 1 %, while the efficiency of third-harmonic generation is several tenths of percent. A strong polarisation dependence of the third-harmonic generation efficiency is revealed. When pumping NLC by a cw laser, generation of spectral supercontinua (covering the visible and near-IR spectral ranges) is observed. The nonlinear effects revealed can be due to the light-induced change in the orientational order in liquid crystals, which breaks the initial symmetry and leads to formation of disclination structures. The NLC optical nonlinearity is believed to be of mixed orientationalelectronic nature as a whole. (laser optics 2012)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SOFT X-RAY SPECTROSCOPY OF THE CYGNUS LOOP SUPERNOVA REMNANT

We present the results of a suborbital rocket flight whose scientific target was the Cygnus Loop Supernova Remnant. The payload consists of wire grid collimators, off-plane grating arrays, and gaseous electron multiplier (GEM) detectors. The system is designed for spectral measurements in the 17-107 A bandpass with a resolution up to {approx}60 ({lambda}/{Delta}{lambda}). The Extended X-ray Off-plane Spectrometer (EXOS) was launched on a Terrier-Black Brant rocket on 2009 November 13 from White Sands Missile Range and obtained 340 s of useable scientific data. The X-ray emission is dominated by O VII and O VIII, including the He-like O VII triplet at {approx}22 A. Another emission feature at {approx}45 A is composed primarily of Si XI and Si XII. The best-fit model to this spectrum is an equilibrium plasma model at a temperature of log(T) = 6.4 (0.23 keV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ANGULAR DISTRIBUTION OF Ly{alpha} RESONANT PHOTONS EMERGING FROM AN OPTICALLY THICK MEDIUM

We investigate the angular distribution of Ly{alpha} photons scattering or emerging from an optically thick medium. Since the evolution of specific intensity I in frequency space and angular space are coupled with each other, we first develop the WENO numerical solver to find the time-dependent solutions of the integro-differential equation of I in frequency and angular space simultaneously. We first show that the solutions with the Eddington approximation, which assume that I is linearly dependent on the angular variable {mu}, yield similar frequency profiles of the photon flux as those without the Eddington approximation. However, the solutions of the {mu} distribution evolution are significantly different from those given by the Eddington approximation. First, the angular distribution of I is found to be substantially dependent on the frequency of the photons. For photons with the resonant frequency {nu}{sub 0}, I contains only a linear term of {mu}. For photons with frequencies at the double peaks of the flux, the {mu}-distribution is highly anisotropic; most photons are emitted radially forward. Moreover, either at {nu}{sub 0} or at the double peaks, the {mu} distributions actually are independent of the initial {mu} distribution of photons of the source. This is because the photons with frequencies either at {nu}{sub 0} or the double peaks undergo the process of forgetting their initial conditions due to resonant scattering. We also show that the optically thick medium is a collimator of photons at the double peaks. Photons from the double peaks form a forward beam with a very small opening angle.

79 ASTRONOMY AND ASTROPHYSICS↗

AN ANALYTICAL MODEL OF INTERSTELLAR GAS IN THE HELIOSPHERE TAILORED TO INTERSTELLAR BOUNDARY EXPLORER OBSERVATIONS

The stationary distribution of interstellar neutral gas in the heliosphere subject to solar gravity, solar radiation pressure, photoionization, and charge exchange is investigated analytically assuming ionization rates and radiation pressure that are proportional to R{sup -2}, where R is the heliocentric radius. The collisionless hyperbolic trajectories of the individual atoms including ionization losses are combined with Liouville's Theorem to construct the heliospheric phase-space distribution function of an interstellar gas species in the solar reference frame under the assumption that the distribution is a drifting Maxwellian at large distances from the Sun. The distribution is transformed to the Earth (essentially Interstellar Boundary Explorer (IBEX)) frame as a function of solar longitude. The expression is then tailored to the latitudinal scan of IBEX as a function of longitude using the fact that IBEX detects each atom close to perihelion in its hyperbolic orbit. The distribution is further adapted to IBEX by integrating the differential intensity over the entrance aperture solid angle of the IBEX-Lo collimator, and over energy to predict the IBEX count rate of helium. The major features of the predicted count rate are described, including a peak in longitude, a peak in latitude at each longitude, and the widths of the major peak in both latitude and longitude. Analytical formulae for these features are derived for comparison with IBEX observations in order to determine the temperature and bulk velocity of the gas in interstellar space. Based in part on these formulae, the results for helium are presented in the companion paper by Moebius et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient propagation of ultra-intense laser beam in dense plasma

Ultra intense laser propagation in extended, dense plasma is investigated through optical and proton probing. When a >1 kJ, 10 ps laser propagates into a long-density scale length plasma, channel formation was observed up to 0.6 nc from the analysis of optical probe images. The proton track analysis shows the formation of strong electric and magnetic fields along the plasma channel, which may lead to the observed collimated electron beam on the laser axis. These results are promising for the feasibility of the direct irradiation scheme of fast ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subdiffraction and spatial filtering due to periodic spatial modulation of the gain-loss profile

We investigate light propagation in the materials with periodically modulated gain-loss profile in both transverse and longitudinal directions with respect to the direction of light propagation. We predict the effects of self-collimation (diffraction-free propagation) of the beams, as well as the superdiffusion (spatial frequency filtering) of the beams depending on the geometry of the gain-loss lattice, and justify the predictions by numerical simulations of the paraxial wave propagation equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compensating slice emittance growth in high brightness photoinjectors using sacrificial charge

Achieving maximum electron beam brightness in photoinjectors requires detailed control of the 3D bunch shape and precise tuning of the beam focusing. Even in state-of-the-art designs, slice emittance growth due to nonlinear space charge forces and partial nonlaminarity often remains non-negligible. In this work, we introduce a new means to linearize the transverse slice phase space: a sacrificial portion of the bunch’s own charge distribution, formed into a wavebroken shock front by highly nonlinear space charge forces within the gun, whose downstream purpose is to dynamically linearize the desired bunch core. We show that linearization of an appropriately prepared bunch can be achieved via strongly nonlaminar focusing of the sacrificial shock front, while the inner core focuses laminarly. This leads to a natural spatial separation of the two distributions: a dense core surrounded by a diffuse halo of sacrificial charge that can be collimated. Multiobjective genetic algorithm optimizations of the ultracompact x-ray free electron laser injector employ this concept, and we interpret it with an analytic model that agrees well with the simulations. In simulation, we demonstrate a final bunch charge of 100 pC, peak current ∼ 30 A, and a sacrificial charge of 150 pC (250 pC total emitted from cathode) with normalized emittance growth of < 20 nm rad due to space charge. This implies a maximum achievable brightness approximately an order of magnitude greater than existing free electron laser injector designs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗