Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

The Machine Protection System for the Fermilab Accelerator Science and Technology Facility

The Machine Protection System (MPS) for the Fermilab Accelerator Science and Technology Facility (FAST) has been implemented and tested. The system receives signals from several subsystems and devices which conveys the relevant status needed to the safely operate the accelerator. Logic decisions are made based on these inputs and some predefined user settings which in turn controls the gate signal to the laser of the photo injector. The inputs of the system have a wide variety of signal types, encoding methods and urgencies for which the system is designed to accommodate. The MPS receives fast shutdown (FSD) signals generated by the beam loss system and inhibits the beam or reduces the beam intensity within a macropulse when the beam losses at several places along the accelerator beam line are higher than acceptable values. TTL or relay contact signals from the vacuum system, toroids, magnet systems etc., are chosen with polarities that ensure safe operation of the accelerator from unintended events such as cable disconnection in the harsh industrial environment of the experimental hall. A RS422 serial communication scheme is used to interface the operation permit generator module and a large number of movable devices each reporting multi-bit status. The system also supports operations at user defined lower beam levels for system conunissioning. The machine protection system is implemented with two commercially available off-the-shelf VMEbus based modules with on board FPGA devices. The system is monitored and controlled via the VMEbus by a single board CPU

Wu, Jinyuan↗

Full-Scale Retrieval and Transfer System Mockup for Pneumatic Conveyance of High-Level Calcine Waste - 19563

The Idaho National Laboratory reprocessed spent nuclear fuel from 1953 to 1994. The reprocessing used solvent extraction to separate uranium, resulting in a high-level radioactive liquid waste. A calcination process was used to convert the liquid waste to a high-level radioactive granular solid, referred to as calcine. The calcine is stored in stainless-steel bins contained within six concrete vaults called the Calcined Solids Storage Facilities (CSSFs). The Calcine Disposition Project is tasked with demonstrating the ability to retrieve the calcine from the bins of CSSF 1 and transferring it to the bins of CSSF 6. CSSF 1 was constructed to be a final calcine repository, with no forethought of retrieval. It represents the greatest technical hurdle to calcine extraction of all the CSSFs. The challenges inherent with accessing the calcine, safely extracting it, and securely transporting it are copious and complex. To overcome those challenges in a timely and objective manner, a full-scale mockup will be constructed. The mockup includes a full-size model of a concentric group of bins from CSSF 1 and a storage vessel representing CSSF 6. Mockup equipment will include an air compressor, filtration, blower/vacuum, and retrieval devices. In addition to defining process parameters, the mockup testing scope will demonstrate the amount of residual calcine that can be expected to be in the bins following extraction. This will be key to preparing for closure of CSSF 1 following removal of the calcine. Once testing is complete, the mockup will constitute a model of the calcine extraction and transport system and will be prepared to fulfill a second advantageous objective: the operators that will carry out the calcine transfer from CSSF 1 to CSSF 6 will be trained using the mockup. The control system will be identical, the major pieces of equipment will be representative, and the procedures will be analogous; hence, high-fidelity training can take place at the mockup. Once radiological operations commence at CSSF 1, the mock-up's commission will still not be completed. If any problems arise during calcine transport, the mockup will be ready to serve as a simulator to more effectively reproduce dilemmas and deduce solutions. The mock-up's mission spans the duration of the project. Its usefulness begins with helping to identify process criteria. Operations personnel will benefit greatly from its use as a training tool. And finally, the immediate availability of a simulator to reproduce problems encountered during radiological extraction and transfer will be invaluable. The knowledge gained during this process will also be of continued benefit as future work is done to remove various types of calcine from the remaining CSSFs. The methodology of safe and secure pneumatic transfer of radioactive material may be of benefit to others throughout the U.S. Department of Energy complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Te inclusions on the performance of CdZnTe radiation detectors

Te inclusions existing at high concentrations in CdZnTe (CZT) material can degrade the performance of CZT detectors. These microscopic defects trap the free electrons generated by incident radiation, so entailing significant fluctuations in the total collected charge and thereby strongly affecting the energy resolution of thick (long-drift) detectors. Such effects were demonstrated in thin planar detectors, and, in many cases, they proved to be the dominant cause of the low performance of thick detectors, wherein the fluctuations in the charge losses accumulate along the charge's drift path. We continued studying this effect using different tools and techniques. We employed a dedicated beamline recently established at BNL's National Synchrotron Light Source for characterizing semiconductor radiation detectors, along with an IR transmission microscope system, the combination of which allowed us to correlate the concentration of defects with the devices performances. We present here our new results from testing over 50 CZT samples grown by different techniques. Our goals are to establish tolerable limits on the size and concentrations of these detrimental Te inclusions in CZT material, and to provide feedback to crystal growers to reduce their numbers in the material.

43 PARTICLE ACCELERATORS↗

Effect of Te Inclusions on the Performance of Cdznte Radiation Detectors

Te inclusions existing at high concentrations in CdZnTe (CZT) material can degrade the performance of CZT detectors. These microscopic defects trap the free electrons generated by incident radiation, so entailing significant fluctuations in the total collected charge and thereby strongly affecting the energy resolution of thick (long-drift) detectors. Such effects were demonstrated in thin planar detectors, and, in many cases, they proved to be the dominant cause of the low performance of thick detectors, wherein the fluctuations in the charge losses accumulate along the charge's drift path. We continued studying this effect using different tools and techniques. We employed a dedicated beamline recently established at BNL's National Synchrotron Light Source for characterizing semiconductor radiation detectors, along with an IR transmission microscope system, the combination of which allowed us to correlate the concentration of defects with the devices' performances. We present here our new results from testing over 50 CZT samples grown by different techniques. Our goals are to establish tolerable limits on the size and concentrations of these detrimental Te inclusions in CZT material, and to provide feedback to crystal growers to reduce their numbers in the material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scale up, Field testing, and Optimization of Nontoxic, Durable, Economical Coatings for Control of Biofouling and Corrosion (Abstract Only)

The objective of this project is the technical maturation and demonstration of a durable, economical, and nontoxic coating, Superhydrophobic Lubricant Infused Composite (SLIC), that will prevent fouling organisms from growing on marine and hydrokinetic (MHK) structures and prevent invasive mussels from growing on hydropower structures. SLIC technology was developed and patented by PNNL. It combines multiple antifouling mechanisms to provide excellent antifouling performance, durability, and low hydrodynamic drag without using toxic materials. Advanced proof-of-concept testing and demonstrations completed during a Phase 1 TCF project attracted industry interest and partnerships for this Phase 2 effort focused on maturation of a commercial product. Specific tasks and tests will shift the development emphasis to optimizing formulations, validating antifouling performance to address specific application needs, explore compatibility with other paint systems, develop a product with useful shelf life (in can), and determine curing times and effective applications methodology. Phase 2 efforts will focus upon technology transfer and commercialization of the technology with the industrial team. Industrial partners now include a coatings development specialist (Lorama), hydrophobic material manufacturer and paint developer (Dry Surface Technologies), nontoxic biodegradable lubricants manufacturer (BioBlend), and aquatic applications specialists (Prometheus Innovations, River Connectivity Systems). Engagement with the MHK device developers, the PNNL Marine and Coastal Research Laboratory (MCRL) test site in Sequim WA, Bureau of Reclamation, and Taylor Shellfish throughout the project will provide topical expertise and field test sites that will deliver crucial real-world performance data. Through this Phase 2 effort, SLIC will transition from a Technical Readiness Level (TRL) 5 to TRL 6 and long-term performance data will be acquired through demonstrations. The field test data will allow optimization of SLIC formulation to enhance performance (e.g., durability) and packaging, which are key de-risking activities for technology transfer and ultimately to the production of a viable commercial product.

13 HYDRO ENERGY↗

Substation Circuit Breaker SCADA Cut-Over

The electric power industry has a unique set of issues related to the infrastructure put in place since the 1880s. As methods of generation, delivery and protection evolve, so must the equipment used by the utility. Furthermore, the equipment in use has a finite life and must be replaced over time. The substation at which this project takes place was originally built in the 1950s, though most of the equipment had already gone through several updates. The issue presented was upgrading the Supervisory Control and Data Acquisition (SCADA) system for all the devices connected to the last SCADA system installed a few decades ago. Though the SCADA system being replaced was connected to substation transformers, breakers, disconnects, relays and other devices, the scope of this report will focus on the cut-over of a single gas circuit breaker. After connecting the circuit breaker to the new SCADA, a system and operability (SO) test would need to be designed and carried out to validate the proper function of the device before returning it to service. This report will follow the design approach, execution, testing, and troubleshooting for the substation circuit breaker SCADA cut-over.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuum electromagnetic gyrokinetic simulations of turbulence in the tokamak scrape-off layer and laboratory devices

Here, we present algorithms and results from Gkeyll, a full-f continuum, electromagnetic gyrokinetic code, designed to study turbulence in the edge region of fusion devices. The edge is computationally very challenging, requiring robust algorithms that can handle large-amplitude fluctuations and stable interactions with plasma sheaths. We present an energy-conserving high-order discontinuous Galerkin scheme that solves gyrokinetic equations in Hamiltonian form. Efficiency is improved by a careful choice of basis functions and automatically generated computation kernels. Previous verification tests were performed in the straight-field-line large plasma device [Shi et al., J. Plasma Phys. 83, 905830304 (2017)] and the Texas Helimak, a simple magnetized torus [Bernard et al., Phys. Plasmas 26, 042301 (2019)], including the effect of end-plate biasing on turbulence. Results for the scrape-off layer for NSTX parameters with a model helical magnetic geometry with bad curvature have been obtained [Shi et al., Phys. Plasmas 26, 012307 (2019)]. In this paper, we present algorithms for the two formulations of electromagnetic gyrokinetics: the Hamiltonian and the symplectic. We describe each formulation and show results of benchmark tests. Although our scheme works for the Hamiltonian formulation, the presence of spurious numerical modes for high-β and large $k^2_⊥ρ^2_s$ regimes shows that the symplectic formulation is more robust. We then review our recent algorithm for the symplectic formulation [Mandell et al., J. Plasma Phys. 86, 905860109 (2020)], along with example application of this new capability. Maintaining positivity of the distribution function can be challenging, and we describe a new and novel exponential recovery based algorithm to address this.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR) power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CODING METHODS FOR USE WITH LOW POWER LASER GENERATED ULTRASOUND

We describe how the application of maximum-length sequence (m-sequence) coding can be used to improve the measured signal-to-noise ratio of ultrasonic waves generated by a low power laser diode. Lamb waves were generated in thin metallic plates using a pulsed excitation. To improve the signal-to-noise ratio of the detected signal, various signal processing methods have been evaluated, with m-sequences described here. We also show how the spectral content of the ultrasonic wave can be controlled by using a modified m-sequence approach.

36 MATERIALS SCIENCE↗

Experimental Testing of a Micron-Scale Laser-Powered Accelerator

An experimental program to develop, perfect, and demonstrate a micron-scale dielectric-based slab-symmetric accelerator is underway at UCLA. The effort includes parallel development of a particle source to be integrated with the accelerator, forming a monolithic radiation source. We present results from first-round cold tests of the structure resonance on a simplified metal-walled device, containing >100 structure periods in an area of 100x20 {mu}m. The resonance frequency and strength can be observed via reflection and transmission measurements on the drive laser. Initial measurements may be consistent with simulation. We also report on the status of the electron source development and on work toward an acceleration test in an all-dielectric structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A portable cryostat for the cold transfer of polarized solid HD targets: HDice-I

We developed a device with moveable liquid nitrogen and liquid helium volumes that is capable of reaching over 2 m into the coldest regions of a cryostat or dilution refrigerator and reliably extracting or installing a target of solid, polarized hydrogen deuteride (HD). This Transfer Cryostat incorporates a cylindrical neodymium rare-earth magnet that is configured as a Halbach dipole, which is maintained at 77 K and produces a 0.1 T field around the HD target. Multiple layers provide a hermetic 77 K-shield as the device is used to maintain a target at 2 K during a transfer between cryostats. Our tests with frozen-spin HD show very little polarization loss for either H (-1±2%, relative) or D (0±3%, relative) over typical transfer periods. Multiple target transfers with this apparatus have shown an overall reliability of about 95% per transfer, which is a significant improvement over earlier versions of the device.

42 ENGINEERING↗

On the stability of capacitance-diaphragm gauges with ceramic membranes

Capacitance-diaphragm gauges with ceramic membranes or diaphragms have been on the market for about 15 years. The long-term stability of these devices with full scales from 13 Pa to 133 kPa has been tested in the past decade by the calibration of gauges used by the manufacturer as reference gauges on the production line. These reference gauges were calibrated annually on a primary standard. It was found that the reproducibility of these devices depends on their full scale. For 13 Pa, the annual reproducibility near full scale varied between 0.02% and 0.04%, and for full scales of 133 Pa and higher, it varied between 0.005% and 0.03% of full scale. The reproducibility of the ceramic capacitance-diaphragm gauges for full scales of 133 Pa and 1.3 kPa was significantly lower than the uncertainty of a primary standard applying the static-expansion method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 {sup 103}Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods of reducing vehicle aerodynamic drag

A small scale model (length 1710 mm) of General Motor SUV was built and tested in the wind tunnel for expected wind conditions and road clearance. Two passive devices, rear screen which is plate behind the car and rear fairing where the end of the car is aerodynamically extended, were incorporated in the model and tested in the wind tunnel for different wind conditions. The conclusion is that rear screen could reduce drag up to 6.5% and rear fairing can reduce the drag by 26%. There were additional tests for front edging and rear vortex generators. The results for drag reduction were mixed. It should be noted that there are aesthetic and practical considerations that may allow only partial implementation of these or any drag reduction options.

42 ENGINEERING↗

Unclonable RFID-based tag-seal for storage containers

We are using the DoD MIL-STD as our guide for microelectronics aging (MIL-STD 883J, Method 1016.2: Life/Reliability Characterization Tests). In that document they recommend aging at 3 temperatures between 200-300C, separated by at least 25C, with the supply voltage at the maximum recommended voltage for the devices at 125C (3.6V in our case). If that voltage causes excessive current or power then it can be reduced and the duration of the tests extended. The MIL-STD also recommends current limiting resistors in series with the supply. Since we don’t have much time and we may not have enough ovens and other equipment, two temperatures separated by at least 50C would be an acceptable backup plan. To ensure a safe range of conditions is used, we are executing 24-hour step tests. For these, we will apply the stress for 24 hours and then measure the device to make sure it wasn’t damaged. During the stress the PUFs should be exercised, but we don’t need to measure their response. Rather, at set intervals our devices should be returned to nominal temperature (under bias), and then measured. The MIL-STD puts these intervals at 4, 8, 16, 32, 64, 128, 256, 512 and 1000 hours, although the test can be stopped early if 75% of the devices have failed. A final recommendation per the MIL-STD is that at least 40 devices should be measured under each condition. Since we only have 25 parts, we will place 10 devices in each of two stress conditions.

25 ENERGY STORAGE↗

Renewed experimentation with Ranchero flux compression genereators

In the late 1990s, Los Alamos pursued a coaxial flux compression generator (FCG) concept that was described in several publications under the name 'Ranchero.' These FCGs were designed to be cost effective high current generators, and a variety of configurations were tested. The Ranchero armature is a 152 mm diameter aluminum cylinder with a 6 mm thick wall. The high explosive (HE) is detonated simultaneously on axis, and as the armature expands a factor of two, the wall thins to {approx}3 mm. At the final 300 mm diameter, the circumference is over 900 mm, and this should allow currents to be generated in the 90 MA range. No tests significantly over 50 MA have been performed but an experiment is planned. We have recently begun using Ranchero devices for a new application and we continue to improve the design. In this paper we describe recent tests of Ranchero and its subsystems. The load for our new application is an imploding aluminum liner that would deform due to the magnetic pressure applied during the initial flux loading. It will, however, implode properly when powered only during the {approx}29 {micro}s Ranchero flux compression time. This gives rise to a new system with explOSively formed fuse (EFF) opening switches and an integral closing switch that isolates the load. A capacitor bank delivers 2.8 MA to the Ranchero circuit in {approx}85 {micro}s. During this time, four parallel 63.5 mm wide EFFs, external to the coaxial system, complete the circuit. After armature motion begins, insulation which initially isolates the load is severed, connecting the load to the FCG in parallel with the EFFs. External HE charges are initiated on each of the EFFs to produce a resistance rise timed to not precede closure of the load isolation switch. The EFFs achieve significant resistance, and the flux remaining in the 191 nH generator and 3 nH transmission line is compressed to generate 30.85 MA in a {approx}12.5 nH static load. On three tests, the EFF system has operated flawlessly, and only {approx}100kA is driven back into the EFFs during peak voltage of the generator output. A test incorporating a 19.5 nH dual liner dynamic load has also been completed, and these results are also presented. Ranchero generators have been operated with armatures from 43 cm to 1.4 m long, corresponding to initial inductances from 56 to 191 nH. MHD code modeling gives better agreement with experiments using modules 43 cm long than the 1.4 m modules, and these results will also be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗