Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Finite time step and spatial grid effects in δf simulation of warm plasmas

This paper introduces a technique for analyzing time integration methods used with the particle weight equations in δf method particle-in-cell (PIC) schemes. The analysis applies to the simulation of warm, uniform, periodic or infinite plasmas in the linear regime and considers the collective behavior similar to the analysis performed by Langdon for full-f PIC schemes [1,2]. We perform both a time integration analysis and spatial grid analysis for a kinetic ion, adiabatic electron model of ion acoustic waves. An implicit time integration scheme is studied in detail for δf simulations using our weight equation analysis and for full-f simulations using the method of Langdon. It is found that the δf method exhibits a CFL-like stability condition for low temperature ions, which is independent of the parameter characterizing the implicitness of the scheme. The accuracy of the real frequency and damping rate due to the discrete time and spatial schemes is also derived using a perturbative method. The theoretical analysis of numerical error presented here may be useful for the verification of simulations and for providing intuition for the design of new implicit time integration schemes for the δf method, as well as understanding differences between δf and full-f approaches to plasma simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Argo Observations of the Deep Mixing Band in the Southern Ocean: A Salinity Modeling Challenge

The Southern Ocean plays an important role in mediating oceanic uptake of CO 2 and heat due to a strong meridional overturning circulation. Gridded Argo float data for 2004–2017 were used to evaluate subsurface processes at the mixed layer depth (MLD) that occur in a narrow deep mixing band. Shifts in the value of the Turner Angle at the MLD indicate that early in the season the MLD deepens slowly as it encounters and is stabilized by a subsurface salt maximum. By September mixing has penetrated this salinity feature and the rate of deepening is faster once the MLD is deeper than the depth where the maximum salinity occurs (~150–200 m). This distinctive salinity layer is the result of surface Ekman transport of fresh water from the south and subsurface advection of high-salinity water from the north. Two configurations of the Community Earth System Model (CESM) ocean-ice forced hindcast experiments—one with 1° and the other with 0.1° horizontal resolution (Parallel Ocean Program low and high resolutions [POP-LR and POP-HR], respectively)—are compared with the Argo data for 2005–2009. POP-LR has a shallow MLD bias common to many Fifth Coupled Models Intercomparison Project (CMIP5) models, while POP-HR has a mix of deep and shallow MLD biases. While both models were able to replicate the large-scale processes leading to formation of a high-salinity layer, the salinity feature in POP-HR is too strong and deep. Neither model was able to replicate the vertical mixing processes leading to penetration of the subsurface salt maximum.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Generation and Industrial Heat Opportunities for Nuclear Plants in the Gulf Coast

The United States (U.S.) nuclear-generation fleet stands as a critical national strategic asset, playing a pivotal role in achieving climate goals. Operating on light-water reactor (LWR) technologies, this fleet provides the largest share of U.S. carbon-free electrical generation, ensuring 24/7 clean-energy stability. With a proven track record of reliability while operating at high-capacity factors, consistently above 90%, the existing nuclear fleet serves as a cornerstone for sustainable energy. The Department of Energy’s (DOE’s) Light Water Reactor Sustainability (LWRS), Flexible Plant Operations and Generation pathway addresses U.S. nuclear power plant (NPP) grid integration challenges in the face of evolving energy landscapes. Research at Idaho National Laboratory (INL) highlights the potential synergy between high-temperature steam-electrolysis (HTSE) technology and nuclear steam and electricity during periods of high renewable grid penetration. Large-scale nuclear-integrated hydrogen production through HTSE presents significant potential for decarbonizing such energy-intensive sectors as oil refining, petrochemicals, ammonia, and fertilizers. The strategic advantage lies in the nuclear sector’s capability to deliver clean electrical and/or steam output during periods of low demand. Nuclear-produced hydrogen—with its ability to provide high-purity clean H 2 well below the national standard of 1 kg of CO 2 per kg of H 2 —represents a breakthrough methodology. This emphasizes the crucial role NPPs can fill in addressing the increasing need for clean hydrogen, establishing them as essential contributors to decarbonization. This report specifically delves into hydrogen-generation opportunities from the U.S. Gulf Coast region. This study aims to assess NPP capabilities for hydrogen production and to identify practical nearby industrial and pipeline-operator off-takers for nuclear-integrated hydrogen production as well as to present some specific case-study analysis showing the conditions under which nuclear hydrogen production and sale can be profitable. Also considered in this report is preliminary analysis of nuclear-heat opportunities accessible near Waterford NPP via transportation of hypothetical steam pipelines and heat-exchange equipment.

08 HYDROGEN↗

The Effect of Transmission-Line Dynamics on a Globally Synchronizing Controller for Power Inverters

In this work, we analyze a dispatchable virtual oscillator control (dVOC) strategy for grid-forming power inverters that ensures almost global synchronization of inverterbased AC power systems when the dynamics of the transmission network are neglected, i.e., if an algebraic model of the transmission lines is used. While this approximation is often justified for conventional power systems, the dynamics of the transmission lines can compromise the stability of an inverterbased power system. Therefore, in this article, we use tools from singular perturbation theory to construct a Lyapunov function candidate and explicit bounds on the controller gains that guarantee global convergence to the set of steady-states for the full power-system with transmission line dynamics. Moreover, we show that the only undesirable steady-state is unstable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Neural Lyapunov Approach to Transient Stability Assessment in Interconnected Microgrids

We propose a neural Lyapunov approach to assessing transient stability in power electronic-interfaced microgrid interconnections. The problem of transient stability assessment is cast as one of learning a neural network-structured Lyapunov function in the state space. Based on the function learned, a security region is estimated for monitoring the security of interconnected microgrids in real-time operation. The efficacy of the approach is tested and validated in a grid-connected microgrid and a three-microgrid interconnection. A comparison study suggests that the proposed method can achieve a less conservative characterization of the security region, as compared with a conventional approach.

Huang, Tong↗

Li-ion and Na-ion intercalation in layered MnO 2 cathodes enabled by using bismuth as a cation pillar

Low-cost batteries based on Earth-abundant materials are needed for large-scale electrical storage for the grid. Cathodes based almost entirely on Mn oxides would reduce overall battery cost but cycling of Mn oxides is often not stable. In Li-ion cells, most polymorphs of MnO 2 undergo irreversible transformation to spinel LiMn 2 O 4 during cycling, causing capacity loss. Doping MnO 2 with Bi is known to stabilize the structure, but previous reports have relied on low-crystallinity material making it impossible to pinpoint the Bi location in the structure or its mechanism. In this work, we report a series of hydrated Bi-doped layered MnO 2 compounds and characterize their structures as a function of Bi amount. Bi is shown to reside in the material interlayer, provoking higher long-range structural order even at a low doping level of 1.3%. Doped material improves the specific capacity and stability of cycling in both Li-ion and Na-ion cells. A high level of Bi doping, 4.3%, causes loss of the interlayer crystal water in non-aqueous electrolyte, and this reduces the interlayer distance. Crystal water is shown to be beneficial in a Na-ion system, while its loss improves Li-ion cycling. This provides fundamental insight into how pillaring by a heavy, multivalent cation stabilizes layered oxides.

25 ENERGY STORAGE↗

Sensitivity of Infrastructure Sectors to the Disruption of Commercial Electric Power

Electric power is crucial to the function of other infrastructures, as well as to the stability of the economy and the social order. Disruption of commercial electric power service, even for brief periods of time, can create significant consequences to the function of other sectors, and make living in some environments untenable. This analysis, conducted in 2017 for the United States Department of Energy (DOE) as part of the Grid Modernization Laboratory Consortium (GMLC) Initiative, focuses on describing the function of each of the other infrastructure sectors and subsectors, with an eye towards those elements of these sectors that depend on primary electric power service through the commercial electric power grid. It leverages the experience of Sandia analysts in analyzing historical disruptive events, and from the development of capabilities designed to identify the physical, logical, and geographic connectivity between infrastructures. The analysis goes on to identify alternatives for the provision of primary electric power service, and the redundancy of said alternatives, to provide a picture of the sector’s ability to withstand an extended disruption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grand Challenges in Modeling, Simulation and Analysis: Extraction and Visualization of Power Systems

Threats to the national electric power grid often require the coupling of real-time state data with look-ahead or forecasting models to provide timely disruption warnings. However, successful accomplishment of this capability presents a grand challenge in modeling, simulation, and analysis. Analysis of inter-area oscillatory modes may provide a new path to anticipate power system stability and address this grand challenge. An algorithm is presented for the identification and analysis of such modes from high resolution phasor measurement data that might indicate a pathway to meet this grand challenge. The process outlined includes data collection, conditioning, extraction of the primary oscillatory frequency, and determination of participating areas of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variational calculations for anisotropic solitons in dipolar Bose-Einstein condensates

We present variational calculations using a Gaussian trial function to calculate the ground state of the Gross-Pitaevskii equation (GPE) and to describe the dynamics of the quasi-two-dimensional solitons in dipolar Bose-Einstein condensates (BECs). Furthermore, we extend the ansatz to a linear superposition of Gaussians, improving the results for the ground state to exact agreement with numerical grid calculations using imaginary time and the split-operator method. We are able to give boundaries for the scattering length at which stable solitons may be observed in an experiment. By dynamic calculations with coupled Gaussians, we are able to describe the rather complex behavior of the thermally excited solitons. The discovery of dynamically stabilized solitons indicates the existence of such BECs at experimentally accessible temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kauai Island Utility Cooperative Energy Storage Study

Sandia National Laboratories performed an assessment of the benefits of energy storage for the Kauai Island Utility Cooperative. This report documents the methodology and results of this study from a generation and production-side benefits perspective only. The KIUC energy storage study focused on the economic impact of using energy storage to shave the system peak, which reduces generator run time and consequently reduces fuel and operation and maintenance (O&M) costs. It was determined that a 16-MWh energy storage system would suit KIUC's needs, taking into account the size of the 13 individual generation units in the KIUC system and a system peak of 78 MW. The analysis shows that an energy storage system substantially reduces the run time of Units D1, D2, D3, and D5 - the four smallest and oldest diesel generators at the Port Allen generating plant. The availability of stored energy also evens the diurnal variability of the remaining generation units during the off- and on-peak periods. However, the net economic benefit is insufficient to justify a load-leveling type of energy storage system at this time. While the presence of storage helps reduce the run time of the smaller and older units, the economic dispatch changes and the largest most efficient unit in the KIUC system, the 27.5-MW steam-injected combustion turbine at Kapaia, is run for extra hours to provide the recharge energy for the storage system. The economic benefits of the storage is significantly reduced because the charging energy for the storage is derived from the same fuel source as the peak generation source it displaces. This situation would be substantially different if there were a renewable energy source available to charge the storage. Especially, if there is a wind generation resource introduced in the KIUC system, there may be a potential of capturing the load-leveling benefits as well as using the storage to dampen the dynamic instability that the wind generation could introduce into the KIUC grid. General Electric is presently conducting such a study and results of this study will be available in the near future. Another study conducted by Electric Power Systems, Inc. (EPS) in May 2006 took a broader approach to determine the causes of KIUC system outages. This study concluded that energy storage with batteries will provide stability benefits and possibly eliminate the load shedding while also providing positive voltage control. Due to the lack of fuel diversity in the KIUC generation mix, SNL recommends that KIUC continue its efforts to quantify the dynamic benefits of storage. The value of the dynamic benefits, especially as an enabler of renewable generation such as wind energy, may be far greater than the production cost benefits alone. A combination of these benefits may provide KIUC sufficient positive economic and operational benefits to implement an energy storage project that will contribute to the overall enhancement of the KIUC system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison between pressure gradient method and MAC method on high Re calculation

A cavity flow driven by shear and buoyancy forces is used as a test problem in the application of a nonstaggered pressure gradient (PG) method in solving the two-dimensional incompressible Navier-Stokes equations. Twelve finite differencing schemes are used to solve the cavity flow problem. The schemes consist of various combinations of grid arrangements, upwinding treatments, and conservativeness of convection terms. An artificial source term is introduced, and the solutions are compared with those obtained by the conventional marker-and-cell (MAC) method. The comparisons favor the PG method. Numerical results obtained by the twelve schemes are compared with exact solutions in order to assess the stability and accuracy of each scheme.

Tan, C.-H.↗

Thermal Neutron Detectors with Discrete Anode Pad Readout

A new two-dimensional thermal neutron detector concept that is capable of very high rates is being developed. It is based on neutron conversion in {sup 3}He in an ionization chamber (unity gas gain) that uses only a cathode and anode plane; there is no additional electrode such as a Frisch grid. The cathode is simply the entrance window, and the anode plane is composed of discrete pads, each with their own readout electronics implemented via application specific integrated circuits. The aim is to provide a new generation of detectors with key characteristics that are superior to existing techniques, such as higher count rate capability, better stability, lower sensitivity to background radiation, and more flexible geometries. Such capabilities will improve the performance of neutron scattering instruments at major neutron user facilities. In this paper, we report on progress with the development of a prototype device that has 48 x 48 anode pads and a sensitive area of 24cm x 24cm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling and Feedback Compensator Design for Power-Hardware-in-the-Loop System for Medium-Voltage Grid-Connected Power Converters

Hardware-in-the-loop (HIL) evaluation is a method in which the test subject is split into a physical part and a simulated part, and these parts are connected with interfaces to form a combined physical-numerical system. Power-hardware-in-the-loop (PHIL) systems, where actual hardware is connected to a real-time model, can exhibit issues of instability, inaccuracy and errors when operating in a closed-loop. The challenges of generating a PHIL setup are that, first, because of the limited dynamic response of the different parts of the system, the test results might be inaccurate, and, second, because of the high frequency noise introduced by the sensors to the closed-loop system, it can be difficult to design a compensator for the real-time emulator response, while stabilizing the closed-loop system at the same time. In this paper, different parts of a PHIL system are characterized, and the feedback compensator system design is proposed for the stable operation of the closed-loop PHIL system. The issues as observed in a PHIL system without any compensator are demonstrated using experimental results, and the effectiveness of a first order phase lead compensator is validated.

compensator design↗

PHIL Validation of Ultracapacitor Storage for Black Start Application

A deck of slides that present the modeling, and calibration to conduct PHIL test of ultracapacitor energy storage system. The PHIL test has been done while preparing for the black start field demonstration with Idaho Falls Power. Presentation is invited to the 6th International Workshop on Grid Simulator Testing of Wind Turbine Power Trains and Other Renewable Technologies.

13 HYDRO ENERGY↗

Ultrafast Metal Electrodeposition Revealed by In Situ Optical Imaging and Theoretical Modeling towards Fast–Charging Zn Battery Chemistry

Metallic Zn is a preferred anode material for rechargeable aqueous batteries towards a smart grid and renewable energy storage. Importantly, understanding how the metal nucleates and grows at the aqueous Zn anode is a critical and challenging step to achieve full reversibility of Zn battery chemistry, especially under fast-charging conditions. Here, by combining in situ optical imaging and theoretical modeling, we uncover the critical parameters governing the electrodeposition stability of the metallic Zn electrode, that is, the competition among crystallographic thermodynamics, kinetics, and Zn 2+ -ion diffusion. Moreover, steady-state Zn metal plating/ stripping with Coulombic efficiency above 99 % is achieved at 10-100 mA cm -2 in a reasonably high concentration (3 M) ZnSO 4 electrolyte. Significantly, a long-term cycling-stable Zn metal electrode is realized with a depth of discharge of 66.7% under 50 mA cm -2 in both Zn || Zn symmetrical cells and MnO 2 || Zn full cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I -- National Study

The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Thanks to advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India's RE targets and identify actions that may be favorable for integration. Our primary tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU's anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD $920 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment - from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India's 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗