Search NASA⌕ Search

SEARCH · Search NASA

Results for “high throughput analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Longitudinal genome-wide association study reveals early QTL that predict biomass accumulation under cold stress in sorghum

Sorghum bicolor is a promising cellulosic feedstock crop for bioenergy due to its high biomass yields. However, early growth phases of sorghum are sensitive to cold stress, limiting its planting in temperate environments. Cold adaptability is crucial for cultivating bioenergy and grain sorghum at higher latitudes and elevations, or for extending the growing season. Identifying genes and alleles that enhance biomass accumulation under early cold stress can lead to improved sorghum varieties through breeding or genetic engineering. We conducted image-based phenotyping on 369 accessions from the sorghum Bioenergy Association Panel (BAP) in a controlled environment with early cold treatment. The BAP includes diverse accessions with dense genotyping and varied racial, geographical, and phenotypic backgrounds. Daily, non-destructive imaging allowed temporal analysis of growth-related traits and water use efficiency (WUE). A genome-wide association study (GWAS) was performed to identify genomic intervals and genes associated with cold stress response. The GWAS identified transient quantitative trait loci (QTL) strongly associated with growth-related traits, enabling an exploration of the genetic basis of cold stress response at different developmental stages. This analysis of daily growth traits, rather than endpoint traits, revealed early transient QTL predictive of final phenotypes. The study identified both known and novel candidate genes associated with growth-related traits and temporal responses to cold stress. The identified QTL and candidate genes contribute to understanding the genetic mechanisms underlying sorghum's response to cold stress. These findings can inform breeding and genetic engineering strategies to develop sorghum varieties with improved biomass yields and resilience to cold, facilitating earlier planting, extended growing seasons, and cultivation at higher latitudes and elevations.

59 BASIC BIOLOGICAL SCIENCES↗

A rapid thioacidolysis method for biomass lignin composition and tricin analysis

Abstract Background Biomass composition varies from plant to plant and greatly affects biomass utilization. Lignin is a heterogeneous phenolic polymer derived mainly from p -coumaryl, coniferyl, and sinapyl alcohols and makes up to 10–25% of lignocellulosic biomass. Recently, tricin, an O -methylated flavone, was identified as a lignin monomer in many grass species. Tricin may function as a nucleation site for lignification and is advocated as a novel target for lignin engineering to reduce lignin content and improve biomass digestibility in grasses. Thioacidolysis is an analytical method that can be adapted to analyze both lignin monomeric composition and tricin content in the lignin polymer. However, the original thioacidolysis procedure is complex, laborious, and time consuming, making it difficult to be adopted for large-scale screening in biomass research. In this study, a modified, rapid higher throughput thioacidolysis method was developed. Results In combination with gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS), the modified thioacidolysis method can be used to simultaneously characterize the lignin composition and tricin content using 2–5 mg of dry samples. The modified method eliminates the solvent extraction and drastically improves the throughput; 80 samples can be processed in one day per person. Our results indicate that there is no significant difference in the determination of lignin S/G ratio and tricin content between the original and modified methods. Conclusions A modified thioacidolysis protocol was established. The results demonstrate that the modified method can be used for rapid, high-throughput, and reliable lignin composition and tricin content analyses for screening transgenic plants for cell wall modifications or in large-scale genome-wide association studies (GWAS).

09 BIOMASS FUELS↗

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Distillation Column Flooding Predictor

The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid/vapor traffic that produce increased contact area and lead to substantial increases in separation efficiency – which translates to a 10% increase in energy efficiency on a BTU/bbl basis. The Flooding Predictor™ operates on the principle that between five to sixty minutes in advance of a flooding event, certain column variables experience an oscillation, a pre-flood pattern. The pattern recognition system of the Flooding Predictor™ utilizes the mathematical first derivative of certain column variables to identify the column’s pre-flood pattern(s). This pattern is a very brief, highly repeatable, simultaneous movement among the derivative values of certain column variables. While all column variables experience negligible random noise generated from the natural frequency of the process, subtle pre-flood patterns are revealed among sub-sets of the derivative values of column variables as the column approaches its hydraulic limit. The sub-set of column variables that comprise the pre-flood pattern is identified empirically through in a two-step process. First, 2ndpoint’s proprietary off-line analysis tool is used to mine historical data for pre-flood patterns. Second, the column is flood-tested to fine-tune the pattern recognition for commissioning. Then the Flooding Predictor™ is implemented as closed-loop advanced control strategy on the plant’s distributed control system (DCS), thus automating control of the column at its hydraulic limit.

02 PETROLEUM↗

RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computational Systems Biology

Computational systems biology is the term that we use to describe computational methods to identify, infer, model, and store relationships between the molecules, pathways, and cells (“systems”) involved in a living organism. Based on this definition, the field of computational systems biology has been in existence for some time. However, the recent confluence of high throughput methodology for biological data gathering, genome-scale sequencing and computational processing power has driven a reinvention and expansion of this field. The expansions include not only modeling of small metabolic{Ishii, 2004 #1129; Ekins, 2006 #1601; Lafaye, 2005 #1744} and signaling systems{Stevenson-Paulik, 2006 #1742; Lafaye, 2005 #1744} but also modeling of the relationships between biological components in very large systems, incluyding whole cells and organisms {Ideker, 2001 #1124; Pe'er, 2001 #1172; Pilpel, 2001 #393; Ideker, 2002 #327; Kelley, 2003 #1117; Shannon, 2003 #1116; Ideker, 2004 #1111}{Schadt, 2003 #475; Schadt, 2006 #1661}{McDermott, 2002 #878; McDermott, 2005 #1271}. Generally these models provide a general overview of one or more aspects of these systems and leave the determination of details to experimentalists focused on smaller subsystems. The promise of such approaches is that they will elucidate patterns, relationships and general features that are not evident from examining specific components or subsystems. These predictions are either interesting in and of themselves (for example, the identification of an evolutionary pattern), or are interesting and valuable to researchers working on a particular problem (for example highlight a previously unknown functional pathway). Two events have occurred to bring about the field computational systems biology to the forefront. One is the advent of high throughput methods that have generated large amounts of information about particular systems in the form of genetic studies, gene expression analyses (both protein and mRNA) and metabolomics. With such tools, research to consider systems as a whole are being conceived, planned and implemented experimentally on an ever more frequent and wider scale. The other is the growth of computational processing power and tools. Methods to analyze large data sets of this kind are often computationally demanding and, as is the case in other areas, the field has benefited from continuing improvements in computational hardware and methods. The field of computational biology is very much like a telescope with two sequential lenses: one lens represents the biological data and the other represents a computational and/or mathematical model of the data. Both lenses must be properly coordinated to yield an image that reflects biological reality. This means that the design parameters for both lenses must be designed in concert to create a system that yields a model of the organism that provides both predictive and mechanistic information. The chapters in this book describe the construction of subcomponents of such a system. Computational systems biology is a rapidly evolving field and no single group of investigators has yet developed a compete system that integrates both data generation and data analysis in such a way so as to allow full and accurate modeling of any single biological organism. However, the field is rapidly moving in that direction. The chapters in this book represent a snapshot of the current methods being developed and used in the area of computational systems biology. Each method or database described within represents one or more steps on the path to a complete description of a biological system. How these tools will evolve and ultimately be integrated is an area of intense research and interest. We hope that readers of this book will be motivated by the chapters within and become involved in this exciting area of research.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the 235 U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires uncertainty «1%. Accounting for material self-shielding properties, pipe thickness, and source-detector orientation is instrumental in determining the robustness of gamma-ray detection in the process monitoring of uranyl nitrate in NUCPs. Monte Carlo models and ray-tracing models were employed to determine the sensitivity of the detected 185.7 keV photon to self-shielding properties, pipe thickness, and source-detector geometry. Considering the implementation of the detection of 1 SQ, diversion of 1 SQ becomes essentially undetectable given the systematic uncertainty, in addition to considerations such as propagating uncertainties due to pipe offset/position, as well as minor variations in pipe thickness. Consequently, pipe thickness was the most sensitive variable in affecting full energy efficiency of the 185.7 keV signature peak with up to 8% variation in efficiency for ±0.5 mm changes in Schedule 40 304L stainless steel piping. Furthermore, computation of the attenuation correction factor of the uranyl nitrate solution [CF(AT) (i.e. εsample)] using Parker's method using with the approximation for the geometrical factor κ≈π/4 was validated through experimental, Monte Carlo and ray-tracing calculations for a uranyl nitrate filled transfer pipe segment. Furthermore, quantifying sensitivity in detector position, as well as voiding effects due to bubbly flow or laminar flow with an air gap in the uranyl nitrate becomes increasingly important as considerations from (static) design-scale measurements translate into (dynamic) field operations tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Evaluation of the Terminal Area Precision Scheduling and Spacing System

This paper describes the design, development and results from a high fidelity human-in-the-loop simulation of an integrated set of trajectory-based automation tools providing precision scheduling, sequencing and controller merging and spacing functions. These integrated functions are combined into a system called the Terminal Area Precision Scheduling and Spacing (TAPSS) system. It is a strategic and tactical planning tool that provides Traffic Management Coordinators, En Route and Terminal Radar Approach Control air traffic controllers the ability to efficiently optimize the arrival capacity of a demand-impacted airport while simultaneously enabling fuel-efficient descent procedures. The TAPSS system consists of four-dimensional trajectory prediction, arrival runway balancing, aircraft separation constraint-based scheduling, traffic flow visualization and trajectory-based advisories to assist controllers in efficient metering, sequencing and spacing. The TAPSS system was evaluated and compared to today's ATC operation through extensive series of human-in-the-loop simulations for arrival flows into the Los Angeles International Airport. The test conditions included the variation of aircraft demand from a baseline of today's capacity constrained periods through 5%, 10% and 20% increases. Performance data were collected for engineering and human factor analysis and compared with similar operations both with and without the TAPSS system. The engineering data indicate operations with the TAPSS show up to a 10% increase in airport throughput during capacity constrained periods while maintaining fuel-efficient aircraft descent profiles from cruise to landing.

Swenson, Harry N.↗

Nuclear Material Accounting and Control (NMAC) for a Commercial Fuel Debundling Facility in the United States

The concept of fuel debundling proposes that all non-fuel components of a fuel assembly be removed prior to beginning the recycling process. It was introduced to reduce the quantity of and cost of disposing high level radioactive waste during recycling in the United States. However, nuclear material accountancy and control programs could also benefit from fuel debundling due to a reduction in self-shielding material for individual fuel rods compared to a fuel assembly. Current NRC regulations and guidance point to an independent fuel debundling facility with a material-possession-only license as the best option for implementing this concept into a used fuel recycling scheme in the United States. This allows the facility to comply only with simple NMAC requirements under Subpart B of 10 CFR Part 74 without the need to submit an NMAC plan to the NRC, exempting it from more tedious and complex NMAC requirements. However, a recycling facility may desire a Pu mass estimate from measurements of each individual fuel rod to improve accountancy into the dissolver. Many technologies and methodologies were considered for performing NMAC in an independent fuel debundling facility in the United States. Few were able to meet anticipated throughput demands of up to 3,300 rods/day and achieve measurement uncertainties suitable for input accountancy for a recycling facility. The best option was a combination of passive gamma-ray spectroscopy and neutron coincidence counting to meet all requirements for the proposed Fuel Debundling Detector (FUDD). Follow-on work will include a full uncertainty analysis to inform what assumptions can be made to meet input accountancy objectives before beginning experimental activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Evaluating Linear Ion Trap for MS3-Based Multiplexed Single-Cell Proteomics

There is a growing demand to develop high-throughput and high-sensitivity mass spectrometry methods for single-cell proteomics. The commonly used isobaric labeling-based multiplexed single-cell proteomics approach suffers from distorted protein quantification due to co-isolated interfering ions during MS/MS fragmentation, also known as ratio compression. We reasoned that the use of MS3-based quantification could mitigate ratio compression and provide better quantification. However, previous studies indicated reduced proteome coverages in the MS3 method, likely due to long duty cycle time and ion losses during multilevel ion selection and fragmentation. Here, in this paper, we described an improved MS acquisition method for MS3-based single-cell proteomics by employing a linear ion trap to measure reporter ions. We demonstrated that linear ion trap can increase the proteome coverages for single-cell-level peptides with even higher gain obtained via the MS3 method. The optimized real-time search MS3 method was further applied to study the immune activation of single macrophages. Among a total of 126 single cells studied, over 1200 and 1000 proteins were quantifiable when at least 50 and 75% nonmissing data were required, respectively. Our evaluation also revealed several limitations of the low-resolution ion trap detector for multiplexed single-cell proteomics and suggested experimental solutions to minimize their impacts on single-cell analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗

Batched matrix computations on hardware accelerators based on GPUs

Scientific applications require solvers that work on many small size problems that are independent from each other. At the same time, the high-end hardware evolves rapidly and becomes ever more throughput-oriented and thus there is an increasing need for an effective approach to develop energy-efficient, high-performance codes for these small matrix problems that we call batched factorizations. The many applications that need this functionality could especially benefit from the use of GPUs, which currently are four to five times more energy efficient than multicore CPUs on important scientific workloads. This study, consequently, describes the development of the most common, one-sided factorizations, Cholesky, LU, and QR, for a set of small dense matrices. The algorithms we present together with their implementations are, by design, inherently parallel. In particular, our approach is based on representing the process as a sequence of batched BLAS routines that are executed entirely on a GPU. Importantly, this is unlike the LAPACK and the hybrid MAGMA factorization algorithms that work under drastically different assumptions of hardware design and efficiency of execution of the various computational kernels involved in the implementation. Thus, our approach is more efficient than what works for a combination of multicore CPUs and GPUs for the problems sizes of interest of the application use cases. The paradigm where upon a single chip (a GPU or a CPU) factorizes a single problem at a time is not at all efficient in our applications’ context. We illustrate all of these claims through a detailed performance analysis. With the help of profiling and tracing tools, we guide our development of batched factorizations to achieve up to two-fold speedup and three-fold better energy efficiency as compared against our highly optimized batched CPU implementations based on MKL library. Finally, the tested system featured two sockets of Intel Sandy Bridge CPUs and we compared with a batched LU factorizations featured in the CUBLAS library for GPUs, we achieve as high as 2.5× speedup on the NVIDIA K40 GPU.

97 MATHEMATICS AND COMPUTING↗

Macrocycle peptides delineate locked-open inhibition mechanism for microorganism phosphoglycerate mutases

Glycolytic interconversion of phosphoglycerate isomers is catalysed in numerous pathogenic microorganisms by a cofactor-independent mutase (iPGM) structurally distinct from the mammalian cofactor-dependent (dPGM) isozyme. The iPGM active site dynamically assembles through substrate-triggered movement of phosphatase and transferase domains creating a solvent inaccessible cavity. Here we identify alternate ligand binding regions using nematode iPGM to select and enrich lariat-like ligands from an mRNA-display macrocyclic peptide library containing >10 12 members. Functional analysis of the ligands, named ipglycermides, demonstrates sub-nanomolar inhibition of iPGM with complete selectivity over dPGM. The crystal structure of an iPGM macrocyclic peptide complex illuminated an allosteric, locked-open inhibition mechanism placing the cyclic peptide at the bi-domain interface. This binding mode aligns the pendant lariat cysteine thiolate for coordination with the iPGM transition metal ion cluster. The extended charged, hydrophilic binding surface interaction rationalizes the persistent challenges these enzymes have presented to small-molecule screening efforts highlighting the important roles of macrocyclic peptides in expanding chemical diversity for ligand discovery.

59 BASIC BIOLOGICAL SCIENCES↗

The effects of carbonaceous inclusions and their distributions on dynamic failure processes in boron carbide ceramics

Commercially available boron carbide ceramics typically have heterogeneous microstructures that contain distributions of processing-induced inclusions. The inclusions that are rich in carbon (i.e., carbonaceous) govern the underlying mechanisms of brittle fracture through wing crack formation, and thus dictate the mechanical response of the ceramic. In this study, we investigate the dynamic failure of five boron carbide ceramic materials with different inclusion populations. All of the materials were prepared by hot-pressing; four of these boron carbides contained different sizes and concentrations of carbonaceous inclusions, while one contained no carbonaceous inclusions. The heterogeneity distributions were characterized in some detail for statistical analysis using scanning electron microscopy and quantitative image analysis. A modified compression Kolsky bar setup with in situ ultra-high-speed microscopic imaging (10 million frames per second) was then used to study the influence of the inclusion distributions on the dynamic failure processes in these materials, at nominal high strain rates of 10 2 -10 3 s -1 . The in situ ultra-high-speed microscopy highlighted the link between micro and macroscale failure processes and demonstrated that the carbonaceous inclusions are indeed the preferential sites for nucleation of wing cracks, as previously hypothesized based on post-mortem observations. The relative orientation of an inclusion with respect to the compression axis was shown to affect the likelihood that it would participate in crack nucleation. In conclusion, all of the ceramics were also found to have orientation-dependent peak compressive stress, regardless of the presence of carbonaceous inclusions, suggesting that grain orientation distributions are also important.

36 MATERIALS SCIENCE↗

A Single Tower Configuration of the Modular Gamma Box Counter System - 13392

Canberra's Standard Gamma Box Counter System is designed to perform accurate quantitative assays of gamma emitting nuclides for a wide range of large containers including B-25 crates and ISO shipping containers. Using a modular building-block approach, the system offers tremendous flexibility for a variety of measurement situations with wide ranges of sample activities and throughput requirements, as well as the opportunity to modify the configuration for other applications at a later date. The typical configuration consists of two opposing towers each equipped with two high purity germanium detectors, and an automated container trolley. This paper presents a modified configuration, consisting of a single tower placed inside a measurement trailer with three detector assemblies, allowing for additional vertical segmentation as well as a viewing a container outside the trailer through the trailer wall. An automatic liquid nitrogen fill system is supplied for each of the detectors. The use of a forklift to move the container for horizontal segmentation is accommodated by creating an additional operational and calibration set-up in the NDA 2000 software to allow for the operator to rotate the container and assay the opposite side, achieving the same sensitivity as a comparable two-tower system. This Segmented Gamma Box Counter System retains the core technologies and design features of the standard configuration. The detector assemblies are shielded to minimize interference from environmental and plant background, and are collimated to provide segmentation of the container. The assembly positions can also be modified in height and distance from the container. The ISOCS calibration software provides for a flexible approach to providing the calibrations for a variety of measurement geometries. The NDA 2000 software provides seamless operation with the current configuration, handling the data acquisition and analysis. In this paper, an overview of this system is discussed, along with the measured performance results, calibration methodology and verification, and minimum detectable activity levels. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices

As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, in this paper we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.

42 ENGINEERING↗

High-throughput chemical imaging for optimizing biofuel synthesis using synthetic biology (Final Technical Report)

Fatty acids can be produced biosynthetically in microbes and these compounds can serve as precursors to biodiesels and other high value oleochemicals. However, progress on engineering fatty acid biosynthesis, and biofuel synthesis more generally, has been hindered by current quantification methods that are either indirect or not amenable to high-throughput or single-cell resolution screening. In this project, we assembled an interdisciplinary team with complimentary expertise in synthetic biology and microscopy, metabolic engineering, and chemical imaging to address these challenges. We used chemical imaging to directly measure lipid biosynthesis in Escherichia coli engineered to produce fatty acids, obtaining detailed single-cell resolution measurements. We deployed stimulated Raman scattering (SRS) microscopy in concert with multiplexed genome engineering and gene circuit design strategies from synthetic biology to optimize production of fatty acids. These results provided novel insight into cell-to-cell heterogeneity present in biofuel production strains. In addition, we introduced new chemical imaging methods which are label-free and do not require fluorescent reporters. These efforts were complemented by other studied developing foundational tools for regulation and control, which offer excellent potential for advancing researchers’ ability to rapidly design, build, and test strains for enhanced biofuel synthesis.

09 BIOMASS FUELS↗