Economizer-based Data Center Liquid Cooling with Advanced Metal Interfaces
Fact sheet about project to reduce cooling energy to 5% of total data center energy
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fact sheet about project to reduce cooling energy to 5% of total data center energy
Explore the source record for details and available documents.
Historically 67 assumed and known leaking tanks in the single-shell tank (SST) system were identified at the Hanford Site. The US DOE, Washington River Protection Solutions LLC., and the State of Washington, Department of Ecology identified 25 of the 67 tanks as likely having had liner leaks by a comprehensive review of current and historical data. The remaining tanks are those with potential leaks from sources other than liner failures such as overfilling the tanks or the failure of process lines connecting SSTs. The location of the leaks was determined, based largely on logging radiological data from dry wells installed around the tank and/or radiological data from laterals installed under select tanks. The dry wells and laterals provide the best indication of the vicinity of the leak location, but not necessarily the exact location of the leak. Twenty of the 25 liner leaks appear to have occurred at or near the bottom of the tanks. Many of the tanks appeared to have multiple leak locations. Leak locations could not be determined for all tanks with the available data. Three of the tanks showed apparent sidewall leaks. Potential causes for liner leaks that were evaluated included tank design features, tank construction conditions, waste temperature, tank waste chemistry conducive to different types of corrosion (uniform corrosion, nitrate induced stress corrosion cracking, pitting, crevice, and liquid-air interface corrosion), and bulges in the tank bottom. (authors)
Hanford nuclear waste has a very high pH, and Hanford tanks are ventilated with air. Air has CO{sub 2(g)} in it, which is an acid, so it has some affinity for the waste. The absorption of CO{sub 2} by the waste is important because CO{sub 2} absorption consumes hydroxide at the liquid-air interface, and the hydroxide is important for inhibiting tank corrosion. NaOH is periodically added to some tanks in order to mitigate the surface acidification. The NaOH added then becomes part of the waste and must be treated as waste, increasing the cost of the mission. The Hobbs Equation, developed at the Savannah River site, is used at Hanford to predict CO{sub 2} absorption from the tank ventilation system. In this study, the Hobbs Equation functional form is theoretically evaluated from thermodynamic calculations of CO{sub 2} absorption, and diffusion rates in the waste surface. This study theoretically justifies the empirical equation reported by Hobbs. Thermodynamic calculations performed using the Environmental Simulation Program (ESP) software on a typical double-shell tank waste composition indicate that essentially 100 % of CO{sub 2} that contacts the waste will react with the waste whenever the pH is above 10. In the 1990's, a substantial amount of data was collected on the concentration of CO{sub 2} in the off-gas of ventilated double-shell tanks at Hanford. This historic data was mined in order to determine the quantity of CO{sub 2} absorbed by the waste. The results of this data mining activity determined that tanks below approximately pH 10 (i.e., tank 241-AN-107) will show limited CO{sub 2} absorption, consistent with both the Hobbs model and the theory developed here. Two other tank with higher pH showed contrasting CO{sub 2} absorption. One showed substantial CO{sub 2} absorption, and the other showed minimal CO{sub 2} absorption despite the high waste pH in one tank, presumably because there was minimal contact between the waste surface and most of the air flow. (authors)
Liquid radioactive wastes at the Hanford and Savannah River sites are stored in large underground carbon steel tanks. The high-level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life (i.e., greater than 60 years). Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. Chemistry controls are based on in-situ coupon tests, waste tank experience, and laboratory testing. These requirements comprise the technical standards for corrosion control. The standards are utilized then as guidelines for operational procedures. The present waste chemistry controls for the Hanford DSTs were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits, which were developed at the Savannah River National Laboratory (SRNL) were coupled with corrosion testing results from Pacific Northwest National Laboratories (PNNL) and adopted for corrosion control of the double-shell tank (DST) waste at the Hanford Site. Since that time, the temperatures of the waste in the DSTs have decreased to less than 50 deg. C in most cases as the radioactive material has decayed. As a consequence, new chemistry controls were formulated for SCC in 2010. This testing however, did not address that potential for pitting in the supernatant and at the liquid-air interface. Indeed, initial tests indicated that the inhibitor requirements for SCC would be insufficient for the prevention of pitting. In addition to lower waste temperatures, future retrieval and process changes may impact the DST waste chemistry. Initial projections suggest that the waste chemistry of the DSTs may shift to a broader range of pH and higher aggressive anion concentrations (e.g., chloride, sulfate, etc.) than the wastes that are presently stored. Additionally, processes within the vitrification facility may result in streams that are returned to the tank farm for evaporation. These streams may also contain high concentrations of aggressive species. SRNL investigated the propensity for pitting of the carbon steel waste tanks at current and projected DST waste chemistries. A statistically designed series of tests provided a pitting factor that relates the ratio of the inhibitor species to the aggressive species and the probability of observing pitting. An acceptable pitting factor was determined and was utilized for the development of a new chemistry envelope. The new chemistry envelope was compared to the envelope that was established for SCC and was determined to be bounding. Validation of the new chemistry envelope was performed via model simulations and comparison with historical experimental results and approaches to establishing chemistry envelopes. The new chemistry envelope will eventually be part of an overall assessment of the condition of the tanks and any changes made to the overall structural integrity program for the Hanford DSTs. (authors)
Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)
Explore the source record for details and available documents.
This report implements a high-fidelity multiphysics modeling framework using the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program tools to track isotopic species in Molten Salt Reactors (MSRs), with a specific focus on the 91-depletion chain within the Molten Salt Reactor Experiment (MSRE). The model integrates neutronics, thermal-hydraulics, depletion, and thermochemistry to simulate the production, transport, and phase transitions of isotopes under steady-state and transient conditions. The main findings reveal that isotopes such as bromine-91 largely remain in the liquid phase, while others, including krypton-91and yttrium-91, transition to the gas phase, significantly influencing the reactor’s radiological source term. The study also shows that during transients, like a reactivity insertion transient, rapid void formation and the expansion of the liquid-gas interface led to substantial transfers of dissolved isotopes into the gas phase, altering isotope distribution and largely increasing the source term in the off-gas system. Additionally, the research highlights that short-lived isotopes dominate the initial off-gas response during transients, while longer-lived isotopes determine the equilibrium state, underscoring the necessity of dynamic simulations for accurate species tracking and reactor safety analysis. The developed methodology will be applied in the future to the tracking of a larger number of species and introduce other species tracking mechanisms, such as deposition and plating.
Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated a new two-phase model into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model. It provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model’s accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase model implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, the model is applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of the mixture drift-flux model for capturing the two-phase flow dynamics critical to MSR operations
Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.
Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.
Chemical reactions at surfaces underlie some of the most important processes of today, including catalysis, energy conversion, microelectronics, human health and the environment. Understanding surface chemical reactions at a fundamental level is at the core of the field of surface science. The Gordon Research Conference on Chemical Reactions at Surfaces is one of the premiere meetings in the field. The program this year will cover a broad range of topics, including heterogeneous catalysis and surface chemistry, surfaces in environmental chemistry and energy conversion, reactions at the liquid-solid and liquid-gas interface, electronic materials growth and surface modification, biological interfaces, and electrons and photons at surfaces. An exciting program is planned, with contributions from outstanding speakers and discussion leaders from the international scientific community. The conference provides a dynamic environment with ample time for discussion and interaction. Attendees are encouraged to present posters; the poster sessions are historically well attended and stimulate additional discussions. The conference provides an excellent opportunity for junior researchers (e.g. graduate students or postdocs) to present their work and interact with established leaders in the field.
Bismuth (Bi) has a fairly low melting point of 544 K making it practical as a liquid metal medium in a number of applications. Under ambient atmospheric conditions the surface of solid Bi oxidizes. While the solid Bi interface has been fairly well characterized with surface science studies upon exposure to oxygen, to date little is known about the molecular level reactivity of the liquid interface. Here, using ambient pressure X-ray photoelectron spectroscopy the liquid-gas interfacial chemistry of Bi was examined upon exposure to oxygen gas and water vapor at 550 K up to a maximum pressure of 0.5 Torr. Water vapor remained unreactive towards the liquid interface over the entire pressure range. Oxygen remined unreactive up to 10 –4 Torr, whereas above this pressure oxidation was observed forming Bi 2 O 3 . The oxidation exposure onset was > 5 x 10 5 Langmuirs, significantly higher than what is required for solid Bi interfaces.
Electrode-polymer interfaces dictate many of the properties of thin films such as capacitance, the electric field experienced by polymers, and charge transport. However, structure and dynamics of charged polymers near electrodes remain poorly understood, especially in the high concentration limit representative of the melts. To develop an understanding of electric field–induced transformations of electrode-polymer interfaces, we have studied electrified interfaces of an imidazolium-based polymerized ionic liquid (PolyIL) using combinations of broadband dielectric spectroscopy, specular neutron reflectivity, and simulations based on the Rayleigh’s dissipation function formalism. Overall, we obtained the camel-shaped dependence of the capacitance on applied voltage, which originated from the responses of an adsorbed polymer layer to applied voltages. This work provides additional insights related to the effects of molecular weight in affecting structure and properties of electrode-polymer interfaces, which are essential for designing next-generation energy storage and harvesting devices.
La 2-x Sr x CuO 4 /La 2 CuO 4 bilayers show interface superconductivity that originates from accumulation and depletion of mobile charge carriers across the interface. Surprisingly, the doping level can be varied broadly (within the interval 0.15 < x < 0.47) without affecting the transition temperature, which stays essentially constant and equal to that in optimally doped material, T c ≈ 40 K. Here we argue that this finding implies that doping up to the optimum level does not shift the chemical potential, unlike in ordinary Fermi liquids. Lastly, we discuss possible physical scenarios that can give doping-independent chemical potential in the pseudogap regime: electronic phase separation, formation of charge-density waves, strong Coulomb interactions, or self-trapping of mobile charge carriers.
Bilge water from ships is regarded as a major pollutant in the marine environment. Bilge water exists in a stable oil-in-water (O/W) emulsion form. However, little is known about the O/W liquid–liquid (l–l) interface. Traditional bulk characterization approaches are not capable of capturing the chemical changes at the O/W l–l interface. Although surfactants are deemed essential in droplet formation, their roles in bilge water stabilization have not been fully revealed. We have utilized novel in situ chemical imaging tools including in situ scanning electron microscopy (SEM) and in situ time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the evolving O/W interface using a NAVY bilge model for the first time. The droplet size distribution (DSD) does not change significantly without the addition of X-100 surfactants under static or rocking conditions. Both the oil components and the water clusters are shown to evolve over time at the O/W droplet interface by in situ liquid SIMS imaging. Of particular interest to droplet stabilization, the contribution of surfactants to the aged bilge droplets becomes more significant as the droplet size increases. The higher mass surfactant component does not appear on the droplet surface immediately while many lower mass surfactants are solvated inside the droplet. We have provided the first three-dimensional images of the evolving O/W interface and demonstrated that in situ surface chemical mapping is powerful enough to reveal the complex and dynamic l–l interface in the liquid state. Our observational insights suggest that surfactants are important in mediating droplet growth and facilitating effective separation of bilge water emulsion.
Conventional closed loop-Kelvin probe force microscopy (KPFM) has emerged as a powerful technique for probing electric and transport phenomena at the solid-gas interface. The extension of KPFM capabilities to probe electrostatic and electrochemical phenomena at the solid–liquid interface is of interest for a broad range of applications from energy storage to biological systems. However, the operation of KPFM implicitly relies on the presence of a linear lossless dielectric in the probe-sample gap, a condition which is violated for ionically-active liquids (e.g., when diffuse charge dynamics are present). Here, electrostatic and electrochemical measurements are demonstrated in ionically-active (polar isopropanol, milli-Q water and aqueous NaCl) and ionically-inactive (non-polar decane) liquids by electrochemical force microscopy (EcFM), a multidimensional (i.e., bias- and time-resolved) spectroscopy method. In the absence of mobile charges (ambient and non-polar liquids), KPFM and EcFM are both feasible, yielding comparable contact potential difference (CPD) values. In ionically-active liquids, KPFM is not possible and EcFM can be used to measure the dynamic CPD and a rich spectrum of information pertaining to charge screening, ion diffusion, and electrochemical processes (e.g., Faradaic reactions). EcFM measurements conducted in isopropanol and milli-Q water over Au and highly ordered pyrolytic graphite electrodes demonstrate both sample- and solvent-dependent features. Finally, the feasibility of using EcFM as a local force-based mapping technique of material-dependent electrostatic and electrochemical response is investigated. The resultant high dimensional dataset is visualized using a purely statistical approach that does not require a priori physical models, allowing for qualitative mapping of electrostatic and electrochemical material properties at the solid–liquid interface.
On November 5, 2010, Space Shuttle mission STS-133 was scrubbed due to a hydrogen leak at the Ground Umbilical Carrier Plate (GUCP). After the scrub, a crack in the foam thermal protection system (TPS) was observed on the External Tank (ET) near the interface between the liquid oxygen (LOX) tank and the Intertank. When the damaged foam was removed, two 9-in. long cracks were found on the feet of Intertank stringer S7-2, and the stringer failure was the cause of the TPS crack. An investigation was conducted to determine the root cause of the cracks, establish a remedy/repair for the stringers, and provide flight rationale for the damaged tank, ET-137. The Space Transportation System (STS) Super Lightweight ET (SLWT) is comprised of two propellant tanks (an aft liquid hydrogen (LH2) tank and a forward LOX tank) and an Intertank. The Intertank serves as the structural connection between the two propellant tanks and also functions to receive and distribute all thrust loads from the solid rocket boosters . The Intertank is a stiffened cylinder structure consisting of eight mechanically joined panels (two integrally-stiffened, machined thrust panels to react the booster loads and six stringer-stiffened skin panels). There are one main ring frame, four intermediate ring frames, and forward and aft flange chords that mate to the respective propellant tanks.. The skin/stringer panels utilize external hat-section stringers that are mechanically attached with rivets along most of their length and with specialty fasteners, such as GP Lockbolts and Hi-Loks, at the forward and aft ends where the stringers attach to the flange chords. During the STS-133 Intertank stringer crack investigation, cracks were found on a total of five stringers. All of the cracks were at the LOX end, in the feet of the stringers, and near the forward fasteners (GP Lockbolts). Video of tanking for the November 5 launch attempt was used to determine that the TPS failure, and thus the stringer failure, occurred as the LOX liquid level crossed the LOX tank / Intertank interface ring frame. Hence, cryogenically-induced displacements were suspected as a contributing cause of the stringer cracks. To study the behavior of Intertank stringers subjected to similar displacements, static load tests of individual stringers, colloquially known as "single stringer bending tests" were performed. Approximately thirty stringers were tested, many of which were cut from the partially completed Intertank for what would have been ET-139. In addition to the tests, finite element (FE) analyses of the test configuration were also performed. In this paper, the FE analyses and test-analysis correlation for stringer test S6-8 are presented. Stringer S6-8 is a "short chord" configuration with no doubler panels.