Search NASA⌕ Search

SEARCH · Search NASA

Results for “mean squared error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Noncoherent DTTLs for Symbol Synchronization

Noncoherent data-transition tracking loops (DTTLs) have been proposed for use as symbol synchronizers in digital communication receivers. [Communication- receiver subsystems that can perform their assigned functions in the absence of synchronization with the phases of their carrier signals ( carrier synchronization ) are denoted by the term noncoherent, while receiver subsystems that cannot function without carrier synchronization are said to be coherent. ] The proposal applies, more specifically, to receivers of binary phase-shift-keying (BPSK) signals generated by directly phase-modulating binary non-return-to-zero (NRZ) data streams onto carrier signals having known frequencies but unknown phases. The proposed noncoherent DTTLs would be modified versions of traditional DTTLs, which are coherent. The symbol-synchronization problem is essentially the problem of recovering symbol timing from a received signal. In the traditional, coherent approach to symbol synchronization, it is necessary to establish carrier synchronization in order to recover symbol timing. A traditional DTTL effects an iterative process in which it first generates an estimate of the carrier phase in the absence of symbol-synchronization information, then uses the carrier-phase estimate to obtain an estimate of the symbol-synchronization information, then feeds the symbol-synchronization estimate back to the carrier-phase-estimation subprocess. In a noncoherent symbol-synchronization process, there is no need for carrier synchronization and, hence, no need for iteration between carrier-synchronization and symbol- synchronization subprocesses. The proposed noncoherent symbolsynchronization process is justified theoretically by a mathematical derivation that starts from a maximum a posteriori (MAP) method of estimation of symbol timing utilized in traditional, coherent DTTLs. In that MAP method, one chooses the value of a variable of interest (in this case, the offset in the estimated symbol timing) that causes a likelihood function of symbol estimates over some number of symbol periods to assume a maximum value. In terms that are necessarily oversimplified to fit within the space available for this article, it can be said that the mathematical derivation involves a modified interpretation of the likelihood function that lends itself to noncoherent DTTLs. The proposal encompasses both linear and nonlinear noncoherent DTTLs. The performances of both have been computationally simulated; for comparison, the performances of linear and nonlinear coherent DTTLs have also been computationally simulated. The results of these simulations show that, among other things, the expected mean-square timing errors of coherent and noncoherent DTTLs are relatively insensitive to window width. The results also show that at high signal-to-noise ratios (SNRs), the performances of the noncoherent DTTLs approach those of their coherent counterparts at, while at low SNRs, the noncoherent DTTLs incur penalties of the order of 1.5 to 2 dB.

Simon, Marvin↗

Influence of Vibrotactile Feedback on Controlling Tilt Motion After Spaceflight

We hypothesize that adaptive changes in how inertial cues from the vestibular system are integrated with other sensory information leads to perceptual disturbances and impaired manual control following transitions between gravity environments. The primary goals of this ongoing post-flight investigation are to quantify decrements in manual control of tilt motion following short-duration spaceflight and to evaluate vibrotactile feedback of tilt as a sensorimotor countermeasure. METHODS. Data is currently being collected on 9 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s, <20 cm radius) in a darkened room is utilized to elicit otolith reflexes in the lateral plane without concordant canal or visual cues. A Tilt-Translation Sled (TTS) is capable of synchronizing pitch tilt with fore-aft translation to align the resultant gravitoinertial vector with the longitudinal body axis, thereby eliciting canal reflexes without concordant otolith or visual cues. A simple 4 tactor system was implemented to provide feedback when tilt position exceeded predetermined levels in either device. Closed-loop nulling tasks are performed during random tilt steps or sum-of-sines (TTS only) with and without vibrotactile feedback of chair position. RESULTS. On landing day the manual control performance without vibrotactile feedback was reduced by >30% based on the gain or the amount of tilt disturbance successfully nulled. Manual control performance tended to return to baseline levels within 1-2 days following landing. Root-mean-square position error and tilt velocity were significantly reduced with vibrotactile feedback. CONCLUSIONS. These preliminary results are consistent with our hypothesis that adaptive changes in vestibular processing corresponds to reduced manual control performance following G-transitions. A simple vibrotactile prosthesis improves the ability to null out tilt motion within a limited range of motion disturbances.

Wood, S. J.↗

Principal Component Noise Filtering for NAST-I Radiometric Calibration

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

Tian, Jialin↗

Determination of Ice Cloud Models Using MODIS and MISR Data

Representation of ice clouds in radiative transfer simulations is subject to uncertainties associated with the shapes and sizes of ice crystals within cirrus clouds. In this study, we examined several ice cloud models consisting of smooth, roughened, homogeneous and inhomogeneous hexagonal ice crystals with various aspect ratios. The sensitivity of the bulk scattering properties and solar reflectances of cirrus clouds to specific ice cloud models is investigated using the improved geometric optics method (IGOM) and the discrete ordinates radiative transfer (DISORT) model. The ice crystal habit fractions in the ice cloud model may significantly affect the simulations of cloud reflectances. A new algorithm was developed to help determine an appropriate ice cloud model for application to the satellite-based retrieval of ice cloud properties. The ice cloud particle size retrieved from Moderate Resolution Imaging Spectroradiometer (MODIS) data, collocated with Multi-angle Imaging Spectroradiometer (MISR) observations, is used to infer the optical thicknesses of ice clouds for nine MISR viewing angles. The relative differences between view-dependent cloud optical thickness and the averaged value over the nine MISR viewing angles can vary from −0.5 to 0.5 and are used to evaluate the ice cloud models. In the case for 2 July 2009, the ice cloud model with mixed ice crystal habits is the best fit to the observations (the root mean square (RMS) error of cloud optical thickness reaches 0.365). This ice cloud model also produces consistent cloud property retrievals for the nine MISR viewing configurations within the measurement uncertainties.

MODIS↗

Nonnegative Matrix Factorization for Efficient Hyperspectral Image Projection

Hyperspectral imaging for remote sensing has prompted development of hyperspectral image projectors that can be used to characterize hyperspectral imaging cameras and techniques in the lab. One such emerging astronomical hyperspectral imaging technique is wide-field double-Fourier interferometry. NASA's current, state-of-the-art, Wide-field Imaging Interferometry Testbed (WIIT) uses a Calibrated Hyperspectral Image Projector (CHIP) to generate test scenes and provide a more complete understanding of wide-field double-Fourier interferometry. Given enough time, the CHIP is capable of projecting scenes with astronomically realistic spatial and spectral complexity. However, this would require a very lengthy data collection process. For accurate but time-efficient projection of complicated hyperspectral images with the CHIP, the field must be decomposed both spectrally and spatially in a way that provides a favorable trade-off between accurately projecting the hyperspectral image and the time required for data collection. We apply nonnegative matrix factorization (NMF) to decompose hyperspectral astronomical datacubes into eigenspectra and eigenimages that allow time-efficient projection with the CHIP. Included is a brief analysis of NMF parameters that affect accuracy, including the number of eigenspectra and eigenimages used to approximate the hyperspectral image to be projected. For the chosen field, the normalized mean squared synthesis error is under 0.01 with just 8 eigenspectra. NMF of hyperspectral astronomical fields better utilizes the CHIP's capabilities, providing time-efficient and accurate representations of astronomical scenes to be imaged with the WIIT.

NMF↗

Field Test: Results of Tandem Walk Performance Following Long-Duration Spaceflight

BACKGROUND: Coordinated locomotion has proven to be challenging for many astronauts following long duration spaceflight. As NASA's vision for spaceflight points toward interplanetary travel, we must prepare for unassisted landings, where crewmembers may need to perform mission critical tasks within minutes of landing. Thus, it is vital to develop a knowledge base from which operational guidelines can be written that define when astronauts can be expected to safely perform certain tasks. Data obtained during the Field Test experiment (FT) will add important insight to this knowledge base. Specifically, we aim to develop a recovery timeline of functional sensorimotor performance during the first 24 hours and several days after landing. METHODS: FT is an ongoing study of 30 long-duration ISS crewmembers. Thus far, 9 have completed the full FT (5 U.S. Orbital Segment [USOS] astronauts and 4 Russian cosmonauts) and 4 more consented and launching within the next year. This is in addition to the eighteen crewmembers that participated in the pilot FT (11 USOS and 7 Russian crewmembers). The FT is conducted three times preflight and three times during the first 24 hours after landing. All crewmembers were tested in Kazakhstan in either the medical tent at the Soyuz landing site (~one hour post-landing), or at the airport (~four hours post-landing). The USOS crewmembers were also tested at the refueling stop (~12 hours post-landing) and at the NASA Johnson Space Center (~24 hours post-landing) and a final session 7 days post-landing. Crewmembers are instrumented with 9 inertial measurement unit sensors that measure acceleration and angular displacement (APDM's Emerald Sensors) and foot pressure-sensing insoles that measure force, acceleration, and center of pressure (Moticon GmbH, Munich, Germany) along with heart rate and blood pressure recording instrumentation. The FT consists of 12 tasks, but here we will focus on the most challenging task, the Tandem Walk, which was also performed as part of pilot FT. To perform the Tandem Walk, subjects begin with their feet together, their arms crossed at their chest and eyes closed. When ready, they brought one foot forward and touched the heel of their foot to their toe, repeating with the other foot, and continuing for about 10 steps. Three trials were collected with the eyes closed and a fourth trial was collected with eyes open. There are four metrics which are used to determine the performance level of the Tandem Walk. The first is percent correct steps. For a step to be counted as correct, the foot could not touch the ground while bringing it forward (no side stepping), eyes must stay closed during the eyes closed trials, the heel and toe should be touching, or almost touching (no large gaps) and there shouldn't be more than a three second pause between steps. Three judges score each step and the median of the three scores is kept. The second metric is the average step speed, or the number of steps/time to complete them. Thirdly, the root mean squared (RMS) error in the resultant trunk acceleration is used to determine the amount of upper body instability observed during the task. Finally, the RMS error of the mediolateral center of pressure as measured by the Moticon insoles is used to determine the mediolateral instability at the foot level. These four parameters are combined into a new overall Tandem Walk Parameter. RESULTS: Preliminary results show that crewmembers perform the Tandem Walk significantly worse the first 24 hours after landing as compared to their baseline performance. We find that each of the four performance metrics is significantly worse immediately after landing. We will present the results of tandem walk performance during the FT thus far. We will also combine these with the 18 crewmembers that participated in the pilot FT, concentrating on the level of performance and recovery rate. CONCLUSION: The Tandem Walk data collected as part of the FT experiment will provide invaluable information on the performance capabilities of astronauts during the first 24 hours after returning from long-duration spaceflight that can be used in planning future Mars, or other deep-space missions with unassisted landings. FT will determine the average sensorimotor recovery timeline and inform return-to-duty guidelines for unassisted landings.

Rosenberg, M. J. F.↗

Polarization Ray Tracing and Polarization Aberration Compensation in Reflective Astronomical Telescopes

Assessing and optimizing polarization performance in the context of ray-based optical design can be challenging. We describe an approach to this problem that decouples polarization effects from optical system geometry for reflective systems. Each surface's polarization properties are parameterized in terms of their impact on retardance and diattenuation in the small angle-of-incidence limit, separating polarization assessment from the task of coating design. A low-resolution ray trace of the system is adequate to determine ray geometry at each interface, which can then be interpolated to rapidly evaluate net Jones Matrix pupil functions. Coating behavior can be easily varied using the ellipsometric parameters to investigate impacts and compensation. Desired values of these parameters can then be specified as constraints in coating design. Investigation with candidate telescope optical designs for LUVOIR show baseline root-mean-square wavefront errors in the nm range for the on-diagonal Jones matrix component, and throughputs of tens of parts per million. Promising possibilities for compensation using a purpose-designed coating on the secondary mirror are discussed, which reduce the on-diagonal wavefront error by a factor 20, with accompanying but more modest reductions in coupling into off-diagonal terms.

Sabatke, Derek↗

PM 2.5 Concentrations over Major Metropolitan Regions Inferred from Airborne High Spectral Resolution Lidar Measurements Using Machine Learning Regression

We use measurements of near-surface aerosol backscatter, extinction, and depolarization acquired by four NASA Langley Research Center airborne High Spectral Resolution Lidars (HSRLs) to develop a machine learning regression methodology to infer PM2.5 concentrations at the surface and aloft. These airborne HSRL measurements were acquired over major metropolitan regions in the United States and Asia during more than 170 flights since 2010. Hourly surface PM2.5 measurements from the EPA air quality system and similar networks in other countries acquired within 10 km and 15 minutes of these near-surface HSRL measurements are used to train models that compute PM2.5 concentrations from the HSRL measurements. We examine several regression methods and find that exponential Gaussian Process algorithms consistently give the best performance in terms of the lowest root-mean-square (RMS) errors and the highest correlations. Model performance varies significantly depending on various combinations of HSRL aerosol measurements (e.g., aerosol backscatter, extinction, depolarization, backscatter color ratios, lidar ratios, aerosol optical thickness) and retrievals (e.g., mixed layer height, aerosol type) used in the regressions. Models that use near-surface measurements of aerosol backscatter and aerosol intensive properties such as depolarization, backscatter color ratio, and lidar ratio typically give the best performance with RMS errors around 4 mg/m3 and correlation coefficients above 0.9. HSRL measurements were often acquired when the aircraft flew systematic “raster-scan” patterns for several hours over these cities. These flight patterns enabled measurements of the spatial, temporal, and vertical variabilities in the distributions of aerosol backscatter and aerosol intensive properties and allowed us to derive the corresponding variabilities in PM2.5 concentrations. We present examples of such variabilities over urban areas in the United States as well as Asia. We describe also how the distribution of surface PM2.5 varies with aerosol type and use these retrievals to examine model simulations of surface PM2.5 in these metropolitan regions. We also discuss how this methodology may be applied to measurements from satellite lidars such as CALIOP on CALIPSO and ATLID on EarthCARE.

lidar↗

PARAMETER ESTIMATION OF THE EXPONENTIALLY DAMPED SINUSOID FOR NOISY SIGNALS

The damped sinusoid equation is a common model for many scientific processes involving damped periodic signals. Here we present two methods for estimating the damped sinusoid parameters for noisy signals. Both methods are based upon an exact, closed form solution to fit the parameters for signals without noise, and they estimate the parameters for the noisy signals by the statistical maximum likelihood criterion. The first method relies on an optimizer to minimize the mean square signal error. The second method estimates the parameters by direct calculation and is suitable when the signal noise is small and the frequencies are sufficiently far from the integer and half integer values.

Pelaia, II, Tom↗

Statistical Interpolation for Surface Reconstruction of PDV and BLR Data

Data collection is becoming more and more dense in dynamic experiments, requiring a variety of diagnostics. Data are detected through such means as holography, Mie scattering / extinction, assay foils, surface imaging, and high-speed photography. The data are measured by radiography, velocimetry, ranging, Fiber Bragg, and pyrometry. The question is how can we unify information from multiple diagnostics and incorporate uncertainties to tell a coherent story about an experiment in a meaningful way? This presentation provides an overview of statistical interpolation by means of Kriging. Kriging involves three basic steps: (1) compute and model covariance spatial structure; (2) compute weights by minimizing mean squared prediction error; and (3) predict at the desired prediction sites.

dynamic experiments, holography, Mie scattering/ex↗

Verification of the pin power reconstruction method in NESTLE

NESTLE is a 3D nodal core simulator that solves the few group neutron diffusion equation using the nodal expansion method (NEM) for the steady state (eigenvalue or fixed-source), adjoint (eigenvalue), and transient (eigenvalue or fixed-source) problems. NESTLE has been in use for over 25 years and has been continuously improved and developed. NESTLE can be used to model either Cartesian geometries (for use with typical PWR, BWR fuel assemblies) or hexagonal geometries (for use with VVER and other triangularly pitched fuel assemblies). As part of NESTLE's ongoing verification and validation process, several computational comparisons have been made to quantify the discrepancies in NESTLE's hexagonal pin power reconstruction method. In this paper, we present the results of these code-to-code comparisons and find that the root mean squared (RMS) error in pin power is comparable to other nodal codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress toward the development of a high-fidelity neutronic \model of MARVEL using Griffin

The Microreactor Applications Research Validation and Evaluation (MARVEL) is a 100 kWth microreactor envisioned to start operations at Idaho National Laboratory (INL) in early 2025. This paper is focused on the development of a high-fidelity neutronic model of the MARVEL reactor using Griffin. In particular, the step-by-step verification procedure against Serpent reference calculations is here reported. In this version of the paper, the comparison is only performed in terms of effective multiplication factor, root mean square percentage error (RMSPE) of the pin power, and maximum error for pin-wise power.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An efficient computational method for characterizing the effects of random surface errors on the average power pattern of reflectors

Based on the works of Ruze (1966) and Vu (1969), a novel mathematical model has been developed to determine efficiently the average power pattern degradations caused by random surface errors. In this model, both nonuniform root mean square (rms) surface errors and nonuniform illumination functions are employed. In addition, the model incorporates the dependence on F/D in the construction of the solution. The mathematical foundation of the model rests on the assumption that in each prescribed annular region of the antenna, the geometrical rms surface value is known. It is shown that closed-form expressions can then be derived, which result in a very efficient computational method for the average power pattern. Detailed parametric studies are performed with these expressions to determine the effects of different random errors and illumination tapers on parameters such as gain loss and sidelobe levels. The results clearly demonstrate that as sidelobe levels decrease, their dependence on the surface rms/wavelength becomes much stronger and, for a specified tolerance level, a considerably smaller rms/wavelength is required to maintain the low sidelobes within the required bounds.

Rahmat-Samii, Y.↗

Charged-Particle Calibration Of Spacecraft-Ranging Signals

Report discusses determination of effective densities of electrically charged particles along paths of microwave signals transmitted to and from spacecraft and use of those densities to calibrate measured signal-propagation times, used to compute distances between ground stations and spacecraft. Oriented toward selection of method of calibration optimal with respect to three criteria: minimization of range error and of root-mean-square uncertainty in range error; minimization of amount, complexity, and/or cost of equipment; and capability of calibrating changes in group velocities of signals on ranging channel.

Nguyen, Tien M.↗

Couch height–based patient setup for abdominal radiation therapy

There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ex situ metrology and data analysis for optimization of beamline performance of aspherical pre-shaped x-ray mirrors at the advanced light source

Super high quality aspherical x-ray mirrors with a residual slope error of ~100 nrad (root-mean-square) and a height error of ~1-2 nm (peak-to-valley), and even lower, are now available from a number of the most advanced vendors utilizing deterministic polishing techniques. The mirror specification for the fabrication is based on the simulations of the desired performance of the mirror in the beamline optical system and is normally given with the acceptable level of deviation of the mirror figure and finish from the desired ideal shape. For example, in the case of aspherical x-ray mirrors designed for the Advanced Light Source (ALS) QERLIN beamline, the ideal shape is defined with the beamline application (conjugate) parameters and their tolerances. Here, we first introduce an original procedure and dedicated software developed at the ALS X-Ray Optics Laboratory (XROL) for optimization of beamline performance of pre-shaped hyperbolic and elliptical mirrors. The optimization is based on results of ex situ surface slope metrology and consists in minimization of the mirror shape error by determining the conjugate parameters of the best-fit ideal shape within the specified tolerances. We describe novel optical metrology instrumentation, measuring techniques, and analytical methods used at the XROL for acquisition of surface slope data and optimization of the optic’s beamline performance. The high efficacy of the developed experimental methods and data analysis procedures is reflected in results of measurements with and performance optimization of hyperbolic and elliptical cylinder mirrors designed and fabricated for the ALS QERLIN beamline.

47 OTHER INSTRUMENTATION↗

Application of a spring-dashpot system to clinical lung tumor motion data

Purpose: The treatment efficacy of radiation therapy for lung tumors can be increased by compensating for breath-induced tumor motion. In this study, we quantitatively examine a mathematical model of pseudomechanical linkages between an external surrogate signal and lung tumor motion. Methods: A spring-dashpot system based on the Voigt model was developed to model the correlation between abdominal respiratory motion and tumor motion during lung radiotherapy. The model was applied to clinical data obtained from 52 treatments ('beams') from 10 patients, treated on the Mitsubishi Real-Time Radiation Therapy system, Sapporo, Japan. In Stage 1, model parameters were optimized for individual patients and beams to determine reference values and to investigate how well the model can describe the data. In Stage 2, for each patient the optimal parameters determined for a single beam were applied to data from other beams to investigate whether a beam-specific set of model parameters is sufficient to model tumor motion over a course of treatment. Results: In Stage 1, the baseline root mean square (RMS) residual error for all individually optimized beam data was 0.90 {+-} 0.40 mm (mean {+-} 1 standard deviation). In Stage 2, patient-specific model parameters based on a single beam were found to model the tumor position closely, even for irregular beam data, with a mean increase with respect to Stage 1 values in RMS error of 0.37 mm. On average, the obtained model output for the tumor position was 95% of the time within an absolute bound of 2.0 and 2.6 mm in Stages 1 and 2, respectively. The model was capable of dealing with baseline, amplitude and frequency variations of the input data, as well as phase shifts between the input abdominal and output tumor signals. Conclusions: These results indicate that it may be feasible to collect patient-specific model parameters during or prior to the first treatment, and then retain these for the rest of the treatment period. The model has potential for clinical application during radiotherapy treatment of lung tumors.

60 APPLIED LIFE SCIENCES↗

Implementing nonlinear optics from Off-Energy closed orbit at NSLS-II

To characterize the second-order (chromatic sextupole) magnet lattice with high precision, we implemented nonlinear optics from off-energy closed orbit (NOECO) tool based on the linear optics from closed orbit modulation (LOCOM) method, named LOCOM-NOECO. The preliminary numerical study indicates that 1–2% precision can be achieved for the calibration of chromatic sextupoles. Further, this accuracy could potentially help in resolving some long-standing challenges of NSLS-II (e.g., the discrepancy between the designed and measured dynamic apertures) if such high precision can be fulfilled. As an independent crosscheck, we also implemented NOECO based on the independent component analysis (ICA) method using turn-by-turn (TBT) BPM data, named ICA-NOECO. Both ICA-NOECO and LOCOM-NOECO have been successfully applied to identify the pre-dialed random errors of a chromatic sextupole family including five power supplies, and achieved the root mean square (RMS) residual error of 1% and peak error less than 2%. Moreover, to mitigate the chromatic sextupole error effect, we applied the correction and achieved significant improvements in the injection efficiency as well as the dynamic apertures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗