Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Short Period Fluctuations in Intelligence Final Report

The problem of isolating fluctuations in intellectual function is one that has long intrigued both psychologists and non-psychologists, We are all aware of our own short-period physiological, mood and motivational changes and many believe that their intelligence must undergo similar change. 1965 for a recent review) does not provide support for this kind of argu- ment. It indicates that measures of intelligence - -at least those intended for use with people other than infants --are usually highly stable over both short and rather extended periods of time: the changes which are indicated have almost always been regarded as errors of measurement. Thus in scientific developments (as opposed, perhaps, to common- sense discussions) ;intelligence usually has been regarded as a highly stable attribute of man. But existing scientific evidence (see Tyler, A notable exception to the scientific theory arguing (albeit im- plicitly) that human intellect does not fluctuate over short period of time is that of Moran (1961) and his co-workers (Moran, Kimble & Mefferd, 1960; 1964; Moran & Mefferd, 1959). The work of these in- vestigators has been directed at designing alternate -form tests to measure some of what are now regarded as the major, replicated-by- research dimensions of human intelligence, viz., what are known as the primary mental abilities (French, 1951: French, Ekstrom & Price, 1963; Guilford, 1966; Guilford & Merrifield, 1960). The Repetitive Psychological Measures (RPM) resulting from this work are intended to assess "change in performance with time" (Moran & Mefferd, 1959: p. 269). little has been done to determine whether or not the performances actually assessed do, in fact, change in a reliable manner. Indeed, evidence somewhat contrary to an hypothesis of short-period change is provided by the high (relative to test length) test-retest correlations ob- tained over a period of 3 hours with the RPM tests (Moran & Mefferd, 1959; Table 2). Hence, while a basic hypothesis underlying this work certainly does imply that abilities change over short periods, evidence for this hypothesis either has not been developed or, where it has (as in test-retest correlations), does not provide convincing support for the hypothesis

Intelligence↗

Precision Segmented Reflector figure control system architecture

A control system architecture for an actively controlled segmented reflector is described along with a design realization for achieving precision alignment of reflector panels. Performance requirements are derived in part from the Large Deployable Reflector, which is a representative mission, and error allocations are made which consider mirror panel surface errors, position measurement and figure estimation, and position control of both quasi-static and dynamic disturbances. The design uses multiple wavelength interferometric edge sensors and voice coil actuators in conjunction with a hybrid control strategy to correct panel position errors. A unit cell shown to be central to the concept is analyzed. The cell integrates the sensing, actuation, and mechanical functions of a control module together with a reflector panel to form a unitized assembly.

Mettler, E.↗

Analysis of Fade Detection and Compensation Experimental Results in a Ka-Band Satellite System

The frequency bands being used for new satellite communication systems are constantly increasing to accommodate the requirements for additional capacity. At these higher frequencies, propagation impairments that did not significantly affect the signal at lower frequencies begin to have considerable impact. In Ka-band, the next logical commercial frequency band to be used for satellite communication, attenuation of the signal due to rain is a primary concern. An experimental satellite built by NASA, the Advanced Communication Technology Satellite (ACTS), launched in September 1993, is the first US communication satellite operating in the Ka-band. In addition to higher carrier frequencies, a number of other new technologies, including onboard baseband processing, multiple beam antennas, and rain fade detection and compensation techniques, were designed into the ACTS. Verification experiments have been conducted since the launch to characterize the new technologies. The focus of this thesis is to describe and validate the method used by the ACTS Very Small Aperture Terminal (VSAT) ground stations in detecting the presence of fade in the communication signal and to adaptively compensate for it by the addition of burst rate reduction and forward error correction. Measured data obtained from the ACTS program is used to validate the compensation technique. In this thesis, models in MATLAB are developed to statistically characterize the increased availability achieved by the compensation techniques in terms of the bit error rate time enhancement factor. Several improvements to the ACTS technique are discussed and possible implementations for future Ka-band systems are also presented.

Johnson, Sandra↗

Computer Simulation of Global Profiles of Carbon Dioxide Using a Pulsed, 2-Micron, Coherent-Detection, Column-Content DIAL System

We present preliminary results of computer simulations of the error in measuring carbon dioxide mixing ratio profiles from earth orbit. The simulated sensor is a pulsed, 2-micron, coherent-detection lidar alternately operating on at least two wavelengths. The simulated geometry is a nadir viewing lidar measuring the column content signal. Atmospheric absorption is modeled using FASCODE3P software with the HITRAN 2004 absorption line data base. Lidar shot accumulation is employed up to the horizontal resolution limit. Horizontal resolutions of 50, 100, and 200 km are shown. Assuming a 400 km spacecraft orbit, the horizontal resolutions correspond to measurement times of about 7, 14, and 28 s. We simulate laser pulse-pair repetition frequencies from 1 Hz to 100 kHz. The range of shot accumulation is 7 to 2.8 million pulse-pairs. The resultant error is shown as a function of horizontal resolution, laser pulse-pair repetition frequency, and laser pulse energy. The effect of different on and off pulse energies is explored. The results are compared to simulation results of others and to demonstrated 2-micron operating points at NASA Langley.

Kavaya, Michael J.↗

Multipath calibration in GPS pseudorange measurements

Novel techniques are disclosed for eliminating multipath errors, including mean bias errors, in pseudorange measurements made by conventional global positioning system receivers. By correlating the multipath signals of different satellites at their cross-over points in the sky, multipath mean bias errors are effectively eliminated. By then taking advantage of the geometrical dependence of multipath, a linear combination of spherical harmonics are fit to the satellite multipath data to create a hemispherical model of the multipath. This calibration model can then be used to compensate for multipath in subsequent measurements and thereby obtain GPS positioning to centimeter accuracy.

Kee, Changdon↗

Application of in-flight thrust determination uncertainty

A numerical example is given of a previously proposed methodology for the evaluation of in-flight thrust measurement uncertainty, using data extracted from a performance report comparing two different missile prototypes under a variety of flight conditions. Attention is given to the data for the AGM-68B Air Launched Cruise Missile, which is powered by the F107 dual-spool, mixed flow turbofan engine. Assessments are made of the definition of the measurement process, instrumentation error estimation, the propagation of errors to thrust calculation, mathematical model errors, the in-flight thrust error component, and correction to standard conditions. It is concluded that in-flight thrust measurement uncertainty limits can be evaluated from measurement system error analysis results and test data for the missile evaluation process presently described.

Adams, G. R.↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗

Intervertebral anticollision constraints improve out-of-plane translation accuracy of a single-plane fluoroscopy-to-CT registration method for measuring spinal motion

Purpose: The study aimed to propose a new single-plane fluoroscopy-to-CT registration method integrated with intervertebral anticollision constraints for measuring three-dimensional (3D) intervertebral kinematics of the spine; and to evaluate the performance of the method without anticollision and with three variations of the anticollision constraints via an in vitro experiment. Methods: The proposed fluoroscopy-to-CT registration approach, called the weighted edge-matching with anticollision (WEMAC) method, was based on the integration of geometrical anticollision constraints for adjacent vertebrae and the weighted edge-matching score (WEMS) method that matched the digitally reconstructed radiographs of the CT models of the vertebrae and the measured single-plane fluoroscopy images. Three variations of the anticollision constraints, namely, T-DOF, R-DOF, and A-DOF methods, were proposed. An in vitro experiment using four porcine cervical spines in different postures was performed to evaluate the performance of the WEMS and the WEMAC methods. Results: The WEMS method gave high precision and small bias in all components for both vertebral pose and intervertebral pose measurements, except for relatively large errors for the out-of-plane translation component. The WEMAC method successfully reduced the out-of-plane translation errors for intervertebral kinematic measurements while keeping the measurement accuracies for the other five degrees of freedom (DOF) more or less unaltered. The means (standard deviations) of the out-of-plane translational errors were less than -0.5 (0.6) and -0.3 (0.8) mm for the T-DOF method and the R-DOF method, respectively. Conclusions: The proposed single-plane fluoroscopy-to-CT registration method reduced the out-of-plane translation errors for intervertebral kinematic measurements while keeping the measurement accuracies for the other five DOF more or less unaltered. With the submillimeter and subdegree accuracy, the WEMAC method was considered accurate for measuring 3D intervertebral kinematics during various functional activities for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable tuning of building models to hourly data

Energy models of existing buildings are unreliable unless calibrated so they correlate well with actual energy usage. Manual tuning requires a skilled professional, is prohibitively expensive for small projects, imperfect, non-repeatable, non-transferable, and not scalable to the dozens of sensor channels that smart meters, smart appliances, and cheap/ubiquitous sensors are beginning to make available today. A scalable, automated methodology is needed to quickly and intelligently calibrate building energy models to all available data, increase the usefulness of those models, and facilitate speed-and-scale penetration of simulation-based capabilities into the marketplace for actualized energy savings. The "Autotune'' project is a novel, model-agnostic methodology which leverages supercomputing, large simulation ensembles, and big data mining with multiple machine learning algorithms to allow automatic calibration of simulations that match measured experimental data in a way that is deployable on commodity hardware. This paper shares several methodologies employed to reduce the combinatorial complexity to a computationally tractable search problem for hundreds of input parameters. Furthermore, accuracy metrics are provided which quantify model error to measured data for either monthly or hourly electrical usage from a highly-instrumented, emulated-occupancy research home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Permutation codes for sources.

Source encoding techniques based on permutation codes are investigated. For a broad class of distortion measures it is shown that optimum encoding of a source permutation code is easy to instrument even for very long block lengths. Also, the nonparametric nature of permutation encoding is well suited to situations involving unknown source statistics. For the squared-error distortion measure a procedure for generating good permutation codes of a given rate and block length is described. The performance of such codes for a memoryless Gaussian source is compared both with the rate-distortion function bound and with the performance of various quantization schemes. The comparison reveals that permutation codes are asymptotically ideal for small rates and perform as well as the best entropy-coded quantizers presently known for intermediate rates. They can be made to compare favorably at high rates, too, provided the coding delay associated with extremely long block lengths is tolerable.

Berger, T.↗

Determination of the Newtonian Gravitational Constant G with Time-of-Swing Method

We present a new value of the Newtonian gravitational constant G by using the time-of-swing method. Several improvements greatly reduce the uncertainties: (1) measuring the anelasticity of the fiber directly; (2) using spherical source masses minimizes the effects of density inhomogeneity and eccentricities; (3) using a quartz block pendulum simplifies its vibration modes and minimizes the uncertainty of inertial moment; (4) setting the pendulum and source masses both in a vacuum chamber reduces the error of measuring the relative positions. By two individual experiments, we obtain G=6.673 49(18)x10{sup -11} m{sup 3} kg{sup -1} s{sup -2} with a standard uncertainty of about 2.6 parts in 10{sup 5}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical phase-locked loop (OPLL) for free-space laser communications with heterodyne detection

Several advantages of coherent free-space optical communications are outlined. Theoretical analysis is formulated for an OPLL disturbed by shot noise, modulation noise, and frequency noise consisting of a white component, a 1/f component, and a 1/f-squared component. Each of the noise components is characterized by its associated power spectral density. It is shown that the effect of modulation depends only on the ratio of loop bandwidth and data rate, and is negligible for an OPLL with loop bandwidth smaller than one fourth the data rate. Total phase error variance as a function of loop bandwidth is displayed for several values of carrier signal to noise ratio. Optimal loop bandwidth is also calculated as a function of carrier signal to noise ratio. An OPLL experiment is performed, where it is shown that the measured phase error variance closely matches the theoretical predictions.

Win, Moe Z.↗

Assessment of Error in Aerosol Optical Depth Measured by AERONET Due to Aerosol Forward Scattering

We present an analysis of the effect of aerosol forward scattering on the accuracy of aerosol optical depth (AOD) measured by CIMEL Sun photometers. The effect is quantified in terms of AOD and solar zenith angle using radiative transfer modeling. The analysis is based on aerosol size distributions derived from multi-year climatologies of AERONET aerosol retrievals. The study shows that the modeled error is lower than AOD calibration uncertainty (0.01) for the vast majority of AERONET level 2 observations, ~99.53%. Only ~0.47% of the AERONET database corresponding mostly to dust aerosol with high AOD and low solar elevations has larger biases. We also show that observations with extreme reductions in direct solar irradiance do not contribute to level 2 AOD due to low Sun photometer digital counts below a quality control cutoff threshold.

AERONET↗

Shack-Hartmann centroid detection method based on high dynamic range imaging and normalization techniques

In the optical quality measuring process of an optical system, including diamond-turning components, the use of a laser light source can produce an undesirable speckle effect in a Shack-Hartmann (SH) CCD sensor. This speckle noise can deteriorate the precision and accuracy of the wavefront sensor measurement. Here we present a SH centroid detection method founded on computer-based techniques and capable of measurement in the presence of strong speckle noise. The method extends the dynamic range imaging capabilities of the SH sensor through the use of a set of different CCD integration times. The resultant extended range spot map is normalized to accurately obtain the spot centroids. The proposed method has been applied to measure the optical quality of the main optical system (MOS) of the mid-infrared instrument telescope smulator. The wavefront at the exit of this optical system is affected by speckle noise when it is illuminated by a laser source and by air turbulence because it has a long back focal length (3017 mm). Using the proposed technique, the MOS wavefront error was measured and satisfactory results were obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WAVELENGTH CALIBRATION OF THE VLT-UVES SPECTROGRAPH

We attempt to measure possible miscalibration of the wavelength scale of the VLT-UVES spectrograph. We take spectra of QSO HE0515-4414 through the UVES iodine cell which contains thousands of well-calibrated iodine lines and compare these lines to the wavelength scale from the standard thorium-argon pipeline calibration. Analyzing three exposures of this z = 1.71 QSO, we find two distinct types of calibration shifts needed to correct the Th/Ar wavelength scale. First, there is an overall average velocity shift of between 100 m s{sup -1} and 500 m s{sup -1} depending upon the exposure. Second, within a given exposure, we find intra-order velocity distortions of 100 m s{sup -1} up to more than 200 m s{sup -1}. These calibration errors are similar to, but smaller than, those found earlier in the Keck HIRES spectrometer. We discuss the possible origins of these two types of miscalibration. We also explore the implications of these calibration errors on the systematic error in measurements of {Delta}{alpha}/{alpha}, the change in the fine-structure constant derived from measurement of the relative redshifts of absorption lines in QSO absorption systems. The overall average, exposure-dependent shifts should be less relevant for fine-structure work, but the intra-order shifts have the potential to affect these results. Using either our measured calibration offsets or a Gaussian model with sigma of around 90 m s{sup -1}, Monte Carlo mock experiments find errors in {Delta}{alpha}/{alpha} of between 1 x 10{sup -6} N {sup -1/2}{sub sys} and 3 x 10{sup -6} N {sup -1/2}{sub sys}, where N{sub sys} is the number of systems used and the range is due to dependence on how many metallic absorption lines in each system are compared.

79 ASTRONOMY AND ASTROPHYSICS↗

Deciphering baryonic feedback with galaxy clusters

Abstract Upcoming cosmic shear analyses will precisely measure the cosmic matter distribution at low redshifts. At these redshifts, the matter distribution is affected by galaxy formation physics, primarily baryonic feedback from star formation and active galactic nuclei. Employing measurements from theMagneticumandIllustrisTNGsimulations and a dark matter + baryon (DMB) halo model, this paper demonstrates that Sunyaev-Zel'dovich (SZ) effect observations of galaxy clusters, whose masses have been calibrated using weak gravitational lensing, can constrain the baryonic impact on cosmic shear with statistical and systematic errors subdominant to the measurement errors of DES-Y3 and LSST-Y1, with systematic errors on S 8 and Ω m reaching 10% and 50% of the statistical errors, respectively. For LSST-Y6 and Roman surveys, these systematic errors increase to 150% and 100% of the statistical errors, indicating the necessity for further model developments for future surveys. We further dissect the contributions from different scales and halos with different masses to cosmic shear, highlighting the dominant role of SZ clusters at scales critical for cosmic shear analyses. These findings suggest a promising avenue for future joint analyses of Cosmic Microwave Background (CMB) and lensing surveys.

Astronomy & Astrophysics↗

3D Measurement Simulation and Relative Pointing Error Verification of the Telescope Mount Assembly Subsystem for the Large Synoptic Survey Telescope

An engineering validation of a large optical telescope consists of executing major performing tests at the subsystem level to verify the overall engineering performance of the observatory. Thus, the relative pointing error verification of the telescope mount assembly subsystem is of special interest to guarantee the absolute pointing performance of the large synoptic survey telescope. This paper presents a new verification method for the relative pointing error assessment of the telescope mount assembly, based on laser tracker technology and several fiducial points fixed to the floor. Monte-Carlo-based simulation results show that the presented methodology is fit for purpose, even if floor movement occurs due to temperature variation during the measurement acquisition process. A further research about laser tracker technology integration into the telescope structure may suggest that such laser tracker technology could be permanently installed in the telescope in order to provide an active alignment system that aims to detect and correct possible misalignment between mirrors or to provide the required mirror positioning verification accuracy after maintenance activities. The obtained results show that two on-board laser tracker systems combined with eight measurement targets could result in measurement uncertainties that are better than 1 arcsec, which would provide a reliable built-in metrology tool for large telescopes.

47 OTHER INSTRUMENTATION↗

Measurement of Seebeck coefficient using a light pulse

A high-temperature (1900 K) Seebeck coefficient apparatus is described in which small thermal gradients are generated in a sample by light pulses transmitted via light pipes. By employing an analog subtraction circuit, the Seebeck coefficient is displayed directly on an X-Y recorder. This technique presents a convenient, accurate, and rapid method for measuring the Seebeck coefficient in highly doped semiconductors as a function of temperature. The nature of the resulting display (X-Y recording) is a valuable tool in determining validity of the data. A straight line results (i.e., a minimum of hysteresis) only if all potential experimental errors are minimized. Under these conditions, the error of measurements of the Seebeck coefficient is estimated to be less than + or - 1 percent.

Wood, C.↗