Search NASA⌕ Search

SEARCH · Search NASA

Results for “normal distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Differential Intrahepatic Phospholipid Zonation in Simple Steatosis and Nonalcoholic Steatohepatitis

Nonalcoholic fatty liver disease (NAFLD) occurs frequently in a setting of obesity, dyslipidemia and insulin resistance, but the etiology of the disease, particularly the events favoring progression to nonalcoholic steatohepatitis (NASH) as opposed to simple steatosis (SS), are not fully understood. Based on known zonation patterns in protein, glucose and lipid metabolism, coupled with evidence that phosphatidylcholine may play a role in NASH pathogenesis, we hypothesized that phospholipid zonation exists in liver and that specific phospholipid abundance and distribution may be associated with histologic disease. A survey of normal hepatic protein expression profiles in the Human Protein Atlas revealed pronounced zonation of enzymes involved in lipid utilization and storage, particularly those facilitating phosphatidylcholine (PC) metabolism. Immunohistochemistry of obese normal, SS and NASH liver specimens with anti-phosphatidylethanomine Nmethyltransferase (PEMT) antibodies showed a progressive decrease in the zonal distribution of this PC biosynthetic enzyme. Phospholipid quantitation by liquid chromatography mass spectrometry (LC-MS) in hepatic extracts of Class III obese patients with increasing NAFLD severity revealed that most PC species with 32, 34 and 36 carbons as well as total PC abundance was decreased with SS and NASH. Matrix assisted laser desorption ionization - imaging mass spectrometry (MALDI-IMS) imaging revealed strong zonal distributions for 32, 34 and 36 carbon PCs in controls (minimal histologic findings) and SS that was lost in NASH specimens. Specific lipid species such as PC 34:1 and PC 36:2 best illustrated this phenomenon. These findings suggest that phospholipid zonation may be associated with the presence of an intrahepatic proinflammatory phenotype and thus have broad implications in the etiopathogenesis of NASH.

59 BASIC BIOLOGICAL SCIENCES↗

A dual frequency radar for ocean roughness sampling

A microwave technique for determining the roughness (rms wave height) of a randomly varying air-water interface has been developed theoretically, verified with laboratory wavetank studies and is currently being implemented for ocean surface measurements in a series of applications flight experiments. These aircraft observations will be near the Chesapeake Light Tower and will include a range of altitudes and sea conditions. The measurement concept involves cross-correlating the envelope fluctuations on two received carriers that are monochromatic when transmitted in a normal direction to the interface and are observed in a backscatter direction after reflection by the large number of randomly distributed specular points on the surface. The measured correlation coefficient (normalized covariance) as a function of carrier frequency separation will depend on the surface roughness, specifically the probability density function of the specular point height. Details of the flight system are discussed, and preliminary flight results are presented.

Weissman, D. E.↗

A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware

Purpose: To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Methods: Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E + IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. Results: The normal tissue integral dose was lowered by about 20% by the E + IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E + IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E + IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. Conclusions: The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning technique (E + IMRT) can decrease the normal tissue integral dose compared to a photon-only IMRT plan. Different planning approaches can be enabled by the use of an electron beam directed toward organs at risk distal to the target, which are still spared due the rapid dose fall-off of the electron beam. Examples of such cases are the lateral electron beams in the thoracic region that do not irradiate the heart and contralateral lung, electron beams pointed toward kidneys in the abdominal region, or beams treating brain lesions pointed toward the brainstem or optical apparatus. For brain, electron vertex beams can also be used without irradiating the whole body. Since radiation retreatments become more and more common, minimizing the normal tissue integral dose and the dose delivered to tissues surrounding the target, as enabled by E + IMRT type techniques, should receive more attention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of inhomogeneous broadening and deliberately introduced disorder on the width of the lasing spectrum of a quantum dot laser

Analytical expressions for the shape and width of the lasing spectra of a quantum-dot (QD) laser in the case of a small (in comparison with the spectrum width) homogeneous broadening of the QD energy levels have been obtained. It is shown that the dependence of the lasing spectrum width on the output power at room temperature is determined by two dimensionless parameters: the width of QD distribution over the optical-transition energy, normalized to temperature, and the ratio of the optical loss to the maximum gain. The optimal dimensions of the laser active region have been found to obtain a specified width of the emission spectrum at a minimum pump current. The possibility of using multilayer structures with QDs to increase the lasing spectrum's width has been analyzed. It is shown that the use of several arrays of QDs with deliberately variable optical-transition energies leads to broadening of the lasing spectra; some numerical estimates are presented.

36 MATERIALS SCIENCE↗

Finite difference procedure for boundary layers including effects of longitudinal and transverse curvatures

A second order viscous layer solution procedure has been developed that does in a consistent way include curvature effects and the corresponding normal pressure gradients. In the present system, the normal momentum equation is retained. The parabolic system of nonlinear partial differential equations is converted by linear finite differencing procedures to a system of linear algebraic equations and solved in primitive coordinates. The solutions have been shown to give smooth stable distributions for all the variables, most particularly the normal velocity which plays an important role in the interaction procedure. An algorithm for matching the viscous layer solution with a rotational characteristics outer solution has been developed.

Tassa, Y.↗

Comparison of Radiation-Induced Normal Lung Tissue Density Changes for Patients From Multiple Institutions Receiving Conventional or Hypofractionated Treatments

Purpose: To quantitatively assess changes in computed tomography (CT)–defined normal lung tissue density after conventional and hypofractionated radiation therapy (RT). Methods and Materials: The pre-RT and post-RT CT scans from 118 and 111 patients receiving conventional and hypofractionated RT, respectively, at 3 institutions were registered to each other and to the 3-dimensional dose distribution to quantify dose-dependent changes in normal lung tissue density. Dose-response curves (DRC) for groups of patients receiving conventional and hypofractionated RT were generated for each institution, and the frequency of density changes >80 Hounsfield Units (HU) was modeled depending on the fractionation type using a Probit model for different follow-up times. Results: For the pooled data from all institutions, there were significant differences in the DRC between the conventional and hypofractionated groups; the respective doses resulting in 50% complication risk (TD{sub 50}) were 62 Gy (95% confidence interval [CI] 57-67) versus 36 Gy (CI 33-39) at <6 months, 48 Gy (CI 46-51) versus 31 Gy (CI 28-33) at 6-12 months, and 47 Gy (CI 45-49) versus 35 Gy (32-37) at >12 months. The corresponding m values (slope of the DRC) were 0.52 (CI 0.46-0.59) versus 0.31 (CI 0.28-0.34) at <6 months, 0.46 (CI 0.42-0.51) versus 0.30 (CI 0.26-0.34) at 6-12 months, and 0.45 (CI 0.42-0.50) versus 0.31 (CI 0.27-0.35) at >12 months (P<.05 for all comparisons). Conclusion: Compared with conventional fractionation, hypofractionation has a lower TD{sub 50} and m value, both suggesting an increased degree of normal tissue density sensitivity with hypofractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved method for the aerodynamic analysis of wing-body-tail configurations in subsonic and supersonic flow. Part 1: Theory and application

A new method has been developed for calculating the pressure distribution and aerodynamic characteristics of wing-body-tail combinations in subsonic and supersonic potential flow. A computer program has been developed to perform the numerical calculations. The configuration surface is subdivided into a large number of panels, each of which contains an aerodynamic singularity distribution. A constant source distribution is used on the body panels, and a vortex distribution having a linear variation in the streamwise direction is used on the wing and tail panels. The normal components of velocity induced at specified control points by each singularity distribution are calculated and make up the coefficients of a system of linear equations relating the strengths of the singularities to the magnitude of the normal velocities. The singularity strengths which satisfy the boundary condition of tangential flow at the control points for a given Mach number and angle of attack are determined by solving this system of equations using an interactive procedure. Once the singularity strengths are known, the pressure coefficients are calculated, and the forces and moments acting on the configuration determined by numerical integration.

Woodward, F. A.↗

Study of grain structure evolution during annealing of a twin-roll-cast Mg alloy

The evolution of microstructure under static annealing was studied for mid-thickness section of a twin-roll-cast (TRC) magnesium alloy. Annealing was performed at 300 °C and 500 °C for different times. Microstructural evolution was quantitatively analyzed, from optical micrographs, using grain path envelope analysis. Additional information from electron backscatter diffraction (EBSD) was used for addressing the possible mechanism(s). It was found that the TRC structure had a bimodal grain size, which was preserved even after annealing at 300 °C. However, the annealing at 500 °C led to a unimodal grain size. This difference in the grain size distribution created a contrasting behavior in the normalized standard deviations. This was primarily attributed to a competition between recovery and recrystallization, and their respective dominance at 300° and 500 °C. A deformation induced recrystallization recovery (DIRR) model was proposed. The proposed model could successfully address the experimental microstructural evolution. - Highlights: • Annealing of twin roll cast (TRC) magnesium alloy was done at temperatures of 300 °C and 500 °C. • TRC had bimodal structure. Bimodality preserved for annealing at 300 °C. Annealing at 500 °C led to unimodal structure. • Grain evolution was described based on the competition between recovery and recrystallization. • Deformation induced recrystallization recovery (DIRR) mechanistic model was developed.

36 MATERIALS SCIENCE↗

HELIUM-IGNITED VIOLENT MERGERS AS A UNIFIED MODEL FOR NORMAL AND RAPIDLY DECLINING TYPE Ia SUPERNOVAE

The progenitors of Type Ia supernovae (SNe Ia) are still unknown, despite significant progress during the past several years in theory and observations. Violent mergers of two carbon-oxygen (CO) white dwarfs (WDs) are a candidate scenario suggested to be responsible for at least a significant fraction of normal SNe Ia. Here, we simulate the merger of two CO WDs using a moving-mesh code that allows for the inclusion of thin helium (He) shells (0.01 M{sub Sun }) on top of the WDs at an unprecedented numerical resolution. The accretion of He onto the primary WD leads to the formation of a detonation in its He shell. This detonation propagates around the CO WD and sends a converging shock wave into its core, known to robustly trigger a second detonation, as in the well-known double-detonation scenario for He-accreting CO WDs. However, in contrast to that scenario where a massive He shell is required to form a detonation through thermal instability, here the He detonation is ignited dynamically. Accordingly the required He-shell mass is significantly smaller, and hence its burning products are unlikely to affect the optical display of the explosion. We show that this scenario, which works for CO primary WDs with CO- as well as He-WD companions, has the potential to explain the different brightness distributions, delay times, and relative rates of normal and fast declining SNe Ia. Finally, we discuss extensions to our unified merger model needed to obtain a comprehensive picture of the full observed diversity of SNe Ia.

79 ASTRONOMY AND ASTROPHYSICS↗

Should Patient Setup in Lung Cancer Be Based on the Primary Tumor? An Analysis of Tumor Coverage and Normal Tissue Dose Using Repeated Positron Emission Tomography/Computed Tomography Imaging

Purpose: Evaluation of the dose distribution for lung cancer patients using a patient setup procedure based on the bony anatomy or the primary tumor. Methods and materials: For 39 patients with non-small-cell lung cancer, the planning fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scan was registered to a repeated FDG-PET/CT scan made in the second week of treatment. Two patient setup methods were analyzed based on the bony anatomy or the primary tumor. The original treatment plan was copied to the repeated scan, and target and normal tissue structures were delineated. Dose distributions were analyzed using dose-volume histograms for the primary tumor, lymph nodes, lungs, and spinal cord. Results: One patient showed decreased dose coverage of the primary tumor caused by progressive disease and required replanning to achieve adequate coverage. For the other patients, the minimum dose to the primary tumor did not significantly deviate from the planned dose: -0.2 {+-} 1.7% (p = 0.71) and -0.1 {+-} 1.7% (p = 0.85) for the bony anatomy setup and the primary tumor setup, respectively. For patients (n = 31) with nodal involvement, 10% showed a decrease in minimum dose larger than 5% for the bony anatomy setup and 13% for the primary tumor setup. The mean lung dose exceeded the maximum allowed 20 Gy in 21% of the patients for the bony anatomy setup and in 13% for the primary tumor setup, whereas for the spinal cord this occurred in 10% and 13% of the patients, respectively. Conclusions: In 10% and 13% of patients with nodal involvement, setup based on bony anatomy or primary tumor, respectively, led to important dose deviations in nodal target volumes. Overdosage of critical structures occurred in 10-20% of the patients. In cases of progressive disease, repeated imaging revealed underdosage of the primary tumor. Development of practical ways for setup procedures based on repeated high-quality imaging of all tumor sites during radiotherapy should therefore be an important research focus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning the temporal evolution of multivariate densities via normalizing flows

In this work, we propose a method to learn multivariate probability distributions using sample path data from stochastic differential equations. Specifically, we consider temporally evolving probability distributions (e.g., those produced by integrating local or nonlocal Fokker–Planck equations). Here, we analyze this evolution through machine learning assisted construction of a time-dependent mapping that takes a reference distribution (say, a Gaussian) to each and every instance of our evolving distribution. If the reference distribution is the initial condition of a Fokker–Planck equation, what we learn is the time-T map of the corresponding solution. Specifically, the learned map is a multivariate normalizing flow that deforms the support of the reference density to the support of each and every density snapshot in time. We demonstrate that this approach can approximate probability density function evolutions in time from observed sampled data for systems driven by both Brownian and Lévy noise. We present examples with two- and three-dimensional, uni- and multimodal distributions to validate the method.

97 MATHEMATICS AND COMPUTING↗

Palmer Station, Antarctica: A Ground-Based Spaceflight Analog Suitable for Validation of Biomedical Countermeasures for Deep Space Missions

Astronauts are known to exhibit a variety of immunological alterations during spaceflight including changes in leukocyte distribution and plasma cytokine concentrations, a reduction in T-cell function, and subclinical reactivation of latent herpesviruses. These alterations are most likely due to mission-associated stressors including circadian misalignment, microgravity, isolation, altered nutrition, and increased exposure to cosmic radiation. Some of these stressors may also occur in terrestrial situations. This study sought to determine if crewmembers performing overwinter deployment at Palmer Station, Antarctica displayed similar immune alterations. The larger goal was to validate a ground analog suitable for the evaluation of countermeasures designed to protect astronauts during future deep space missions. For this pilot study, plasma, saliva, hair, and health surveys were collected from Palmer Station, Antarctica winterover participants at baseline, and at five overwinter timepoints. Twenty-six subjects consented to participate over the course of two seasons. Initial sample processing was performed at Palmer, and eventually stabilized samples were returned to the Johnson Space Center for analysis. A white blood cell differential was performed (real time) using a fingerstick blood sample to determine alterations in basic leukocyte subsets throughout the winterover. Plasma and saliva samples were analyzed for 30 and 13 cytokines, respectively. Saliva was analyzed for cortisol concentration and three latent herpesviruses (DNA by qPCR), EBV, HSV1, and VZV. Hair samples were analyzed for several hormones, as a measure of stress over prolonged periods of time. Voluntary surveys related to general health and adverse clinical events were distributed to participants. It is noteworthy that due to logistical constraints due to COVID-19, the baseline samples for each season were collected in Punta Arenas, Chile, after long international travel and during isolation. Therefore, the palmer pre mission samples may not reflect a true normal ‘baseline’. Minimal alterations were observed in leukocyte distribution during overwinter. The mean percentage of monocyte concentration elevated at one timepoint. Plasma G-CSF, IL1RA, MCP-1, MIP-1β, TNFα and VEGF were decreased during at least one overwinter timepoint, whereas RANTES was significantly increased. No statistically significant changes were observed in mean saliva cytokine concentrations. Salivary cortisol was substantially elevated throughout the entire winterover compared to baseline. Compared to shedding levels observed in healthy controls (23%), the percentage of participants who shed EBV was higher throughout all winterover timepoints (52-60%). Five subjects shed HSV1 during at least one timepoint throughout the season compared to no subjects shedding during pre-deployment. Finally, VZV reactivation, common in astronauts but exceptionally rare in ground-based stress analogs, was observed in one subject during pre-deployment and a different subject at WO2 and WO3. These pilot data, somewhat influenced by the COVID-19 situation, do suggest that participants at Palmer Station do undergo immunological alterations similar to, but likely in reduced magnitude, as those observed in astronauts. We suggest that overwinter at Palmer Station may be suitable test analog for spaceflight biomedical countermeasures designed to mitigate clinical risks for deep space missions.

Space↗

Quantifying Local Radiation-Induced Lung Damage From Computed Tomography

Purpose: Optimal implementation of new radiotherapy techniques requires accurate predictive models for normal tissue complications. Since clinically used dose distributions are nonuniform, local tissue damage needs to be measured and related to local tissue dose. In lung, radiation-induced damage results in density changes that have been measured by computed tomography (CT) imaging noninvasively, but not yet on a localized scale. Therefore, the aim of the present study was to develop a method for quantification of local radiation-induced lung tissue damage using CT. Methods and Materials: CT images of the thorax were made 8 and 26 weeks after irradiation of 100%, 75%, 50%, and 25% lung volume of rats. Local lung tissue structure (S{sub L}) was quantified from local mean and local standard deviation of the CT density in Hounsfield units in 1-mm{sup 3} subvolumes. The relation of changes in S{sub L} (DELTAS{sub L}) to histologic changes and breathing rate was investigated. Feasibility for clinical application was tested by applying the method to CT images of a patient with non-small-cell lung carcinoma and investigating the local dose-effect relationship of DELTAS{sub L}. Results: In rats, a clear dose-response relationship of DELTAS{sub L} was observed at different time points after radiation. Furthermore, DELTAS{sub L} correlated strongly to histologic endpoints (infiltrates and inflammatory cells) and breathing rate. In the patient, progressive local dose-dependent increases in DELTAS{sub L} were observed. Conclusion: We developed a method to quantify local radiation-induced tissue damage in the lung using CT. This method can be used in the development of more accurate predictive models for normal tissue complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); soft open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-124: Dosimetric Comparison of HDR Brachytherapy and Intensity Modulated Proton Therapy

Purpose: Brachytherapy is known to be able to deliver more radiation dose to tumor while minimizing radiation dose to surrounding normal tissues. Proton therapy also provides superior dose distribution due to Bragg peak. Since both HDR and Intensity Modulated Proton Therapy (IMPT) are beneficial for their quick dose drop off, our goal in this study is to compare the pace of dose gradient drop-off between HDR and IMPT plans based on the same CT image data-set. In addition, normal tissues sparing were also compared among HDR, IMPT and SBRT. Methods: Five cervical cancer cases treated with EBRT + HDR boost combination with Tandem and Ovoid applicator were used for comparison purpose. Original HDR plans with prescribed dose of 5.5 Gy x 5 fractions were generated and optimized. The 100% isodose line of HDR plans was converted to a dose volume, and treated as CTV for IMPT and SBRT planning. The same HDR CT scans were also used for IMPT plan and SBRT plan for direct comparison. The philosophy of the IMPT and SBRT planning was to create the same CTV coverage as HDR plans. All three modalities treatment plans were compared to each other with a set of predetermined criteria. Results: With similar target volume coverage in cervix cancer boost treatment, HDR provides a slightly sharper dose drop-off from 100% to 50% isodose line, averagely in all directions compared to IMPT. However, IMPT demonstrated more dose gradient drop-off at the junction of the target and normal tissues by providing more normal tissue sparing and superior capability to reduce integral dose. Conclusion: IMPT is capable of providing comparable dose drop-off as HDR. IMPT can be explored as replacement for HDR brachytherapy in various applications.

60 APPLIED LIFE SCIENCES↗

Involved-Site Image-Guided Intensity Modulated Versus 3D Conformal Radiation Therapy in Early Stage Supradiaphragmatic Hodgkin Lymphoma

Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows for margin reduction and highly conformal dose distribution, with consistent advantages in sparing of normal tissues. The purpose of this retrospective study was to compare involved-site IG-IMRT with involved-site 3D conformal RT (3D-CRT) in the treatment of early stage Hodgkin lymphoma (HL) involving the mediastinum, with efficacy and toxicity as primary clinical endpoints. Methods and Materials: We analyzed 90 stage IIA HL patients treated with either involved-site 3D-CRT or IG-IMRT between 2005 and 2012 in 2 different institutions. Inclusion criteria were favorable or unfavorable disease (according to European Organization for Research and Treatment of Cancer criteria), complete response after 3 to 4 cycles of an adriamycin- bleomycin-vinblastine-dacarbazine (ABVD) regimen plus 30 Gy as total radiation dose. Exclusion criteria were chemotherapy other than ABVD, partial response after ABVD, total radiation dose other than 30 Gy. Clinical endpoints were relapse-free survival (RFS) and acute toxicity. Results: Forty-nine patients were treated with 3D-CRT (54.4%) and 41 with IG-IMRT (45.6%). Median follow-up time was 54.2 months for 3D-CRT and 24.1 months for IG-IMRT. No differences in RFS were observed between the 2 groups, with 1 relapse each. Three-year RFS was 98.7% for 3D-CRT and 100% for IG-IMRT. Grade 2 toxicity events, mainly mucositis, were recorded in 32.7% of 3D-CRT patients (16 of 49) and in 9.8% of IG-IMRT patients (4 of 41). IG-IMRT was significantly associated with a lower incidence of grade 2 acute toxicity (P=.043). Conclusions: RFS rates at 3 years were extremely high in both groups, albeit the median follow-up time is different. Acute tolerance profiles were better for IG-IMRT than for 3D-CRT. Our preliminary results support the clinical safety and efficacy of advanced RT planning and delivery techniques in patients affected with early stage HL, achieving complete response after ABVD-based chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the chi-squared approximation for bivariate normal tolerance regions

Let X be a two-dimensional random variable distributed according to N2(mu,Sigma) and let bar-X and S be the respective sample mean and covariance matrix calculated from N observations of X. Given a containment probability beta and a level of confidence gamma, we seek a number c, depending only on N, beta, and gamma such that the ellipsoid R = (x: (x - bar-X)'S(exp -1) (x - bar-X) less than or = c) is a tolerance region of content beta and level gamma; i.e., R has probability gamma of containing at least 100 beta percent of the distribution of X. Various approximations for c exist in the literature, but one of the simplest to compute -- a multiple of the ratio of certain chi-squared percentage points -- is badly biased for small N. For the bivariate normal case, most of the bias can be removed by simple adjustment using a factor A which depends on beta and gamma. This paper provides values of A for various beta and gamma so that the simple approximation for c can be made viable for any reasonable sample size. The methodology provides an illustrative example of how a combination of Monte-Carlo simulation and simple regression modelling can be used to improve an existing approximation.

Feiveson, Alan H.↗

Wind tunnel force and pressure tests of a 21% thick general aviation airfoil with 20% aileron, 25% slotted flap and 10% slot-lip spoiler

Force and surface pressure distributions were measured for the 21% LS(1)-0421 modified airfoil fitted with 20% aileron, 25% slotted flap and 10% slot lip spoiler. All tests were conducted at a Reynolds number of 2.2 x 10 to the 6th power and a Mach number of 0.13. The lift, drag, pitching moments, control surface normal force and hinge moments, and surface pressure distributions are included in the results. Incremental performance of flap and aileron are discussed and compared to the GA(W)-2 airfoil. Spoiler control which shows a slight reversal tendency at high alpha, is examined.

Wentz, W. H., Jr.↗