Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Structure and Morphology of Neodymium-doped Cerium Oxide Solid Solution Prepared by a Combined Simple Polymer Heating and D.C.-Magnetron Sputtering Method

Neodymium-doped Cerium Oxide (NDC) solid solution is attractive alternative material to replace yttria-stabillized zirconia (YSZ) used as an electrolyte for solid-oxide fuel cells (SOFCs). In this study Nd-CeO{sub 2} nanoparticles with Nd of 3, 6 and 9 at./at.-% were synthesized by simple polymer heating. The NDC thin films were deposited on silicon substrates by using target made from the nanoparticles. Deposition process was carried out by D.C.-magnetron sputtering at temperature as low as 375 deg. C. XRD pattern was used to confirm solid solubility and structural properties of the films. The results indicated that all samples are single phase solid solution with cubic fluorite structure. Their lattice parameters increase with increasing Nd content. It was also found that the mean grain size decrease with increasing Nd content. SEM analysis showed that NDC thin films have dense and uniform thickness. These results revealed that the nanoparticles and thin films of NDC solid solution are successfully prepared by a combined simple polymer heating and D.C.-Magnetron Sputtering method at low temperature.

36 MATERIALS SCIENCE↗

SU-E-T-590: Optimizing Magnetic Field Strengths with Matlab for An Ion-Optic System in Particle Therapy Consisting of Two Quadrupole Magnets for Subsequent Simulations with the Monte-Carlo Code FLUKA

Purpose: Aim of this study was to optimize the magnetic field strengths of two quadrupole magnets in a particle therapy facility in order to obtain a beam quality suitable for spot beam scanning. Methods: The particle transport through an ion-optic system of a particle therapy facility consisting of the beam tube, two quadrupole magnets and a beam monitor system was calculated with the help of Matlab by using matrices that solve the equation of motion of a charged particle in a magnetic field and field-free region, respectively. The magnetic field strengths were optimized in order to obtain a circular and thin beam spot at the iso-center of the therapy facility. These optimized field strengths were subsequently transferred to the Monte-Carlo code FLUKA and the transport of 80 MeV/u C12-ions through this ion-optic system was calculated by using a user-routine to implement magnetic fields. The fluence along the beam-axis and at the iso-center was evaluated. Results: The magnetic field strengths could be optimized by using Matlab and transferred to the Monte-Carlo code FLUKA. The implementation via a user-routine was successful. Analyzing the fluence-pattern along the beam-axis the characteristic focusing and de-focusing effects of the quadrupole magnets could be reproduced. Furthermore the beam spot at the iso-center was circular and significantly thinner compared to an unfocused beam. Conclusion: In this study a Matlab tool was developed to optimize magnetic field strengths for an ion-optic system consisting of two quadrupole magnets as part of a particle therapy facility. These magnetic field strengths could subsequently be transferred to and implemented in the Monte-Carlo code FLUKA to simulate the particle transport through this optimized ion-optic system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of cooling rates on the structure, density and micro-indentation behavior of the Fe, Co-based bulk metallic glass

The experiments demonstrate that ductility of the samples of bulk metallic glass (BMG) with the same chemical composition increased with decreasing sample size. It is shown that microhardness and density increases with decreasing the cooling rate. The fracture morphology of rods after compressive fracture were different on the cross section. Two characteristic features of the compressive fracture morphologies of metallic glasses (MGs) were observed in samples: smooth region and the vein pattern. Many parallel shear bands were observed on the deformed specimen with ϕ = 2 mm in diameter. The results provide more understanding on the relationship among the cooling rate, structure and micro-indentation behavior of the Fe-Co-based BMGs. - Highlights: •Fracture morphology and micro-indentation behavior is studied. •The smaller BMG sample exhibits the larger plasticity. •Microhardness and density increase with decreasing the cooling rate. •Formation of shear bands has been reported in deformed specimens. •Structure and mechanical properties of BMGs can be controlled by the cooling rate.

36 MATERIALS SCIENCE↗

Advanced FIB-based Preparation of Cryogenically-prepared Specimens for APT Analysis

The utilization of the focused ion beam scanning electron microscope (FIB-SEM) has aided the application of Atom Probe Tomography (APT) to a continually-growing variety of materials, including soft biological materials. However, the regular application of APT to hydrated interfaces such as those found in biological and environmental materials is lacking in large part due to difficulties in specimen preparation under high and ultra-high vacuum conditions. Although a FIB-SEM based cryogenic specimen preparation approach offers a rational route to the preparation of such specimens for APT analysis, many practical aspects such as welding and limitations in the cryo stage manipulation makes it challenging for routine liftout of site-targeted specimens. In this work, we describe our recent efforts in the development of a site-specific liftout and attachment scheme for cryogenically cooled specimens involving a combination of redeposition and overcoating of organic and organometallic molecules, as shown in Fig. 1a-d for a cryogenically-frozen corroded glass sample containing a hydrated porous gel surface layer. Application of an annular milling pattern to the frozen specimens leads to a needle-shaped morphology necessary for APT analysis with the targeted water-ice filled porous corroded silicate glass region of interest near the apex. Using a custom shuttle device and environmental transfer hub at PNNL to facilitate environmentally-protected specimen transfer, APT analysis was applied to directly map, for the first time, a water/solid interface in 3D to reveal the complex nanoscale water-filled porous network of corroded glass. Application of this unique specimen preparation approach to biological specimens will also be discussed, as well as the application of a unique cryo nanomaniupulator with integrated gas injection system to enable controlled FIB-based welding under cryogenic temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Polypyrrole-based nitrogen-doped carbon replicas of SBA-15 and SBA-16 containing magnetic nanoparticles

Polypyrrole-based ordered mesoporous carbons (OMCs) were synthesized via chemical vapor infiltration of pyrrole into pores of the SBA-15 and SBA-16 silica templates containing iron(III) chloride catalyst (FeCl{sub 3}). After carbonization of polypyrrole at 800 C and etching of the silica templates with hydrofluoric acid solution, nitrogen-doped and graphitic OMCs with incorporated magnetic nanoparticles were obtained. These materials were analyzed by CHNS elemental analysis, thermogravimetry (TG), nitrogen adsorption, small and wide angle powder X-ray diffraction (XRD), Raman spectroscopy, scanning, and transmission electron microscopy (TEM). The resulting carbon replicas retained the crystallographic symmetry of the silica templates: namely, P6mm in the case of the SBA-15 template, and Im3m in the case of the SBA-16 template. The uniformity, size, and volume of ordered mesopores in the carbon replicas were affected by structural properties of the templates used as shown by analysis of nitrogen adsorption isotherms and pore size distributions. A better infiltration of carbon precursor was achieved for the templates with larger pores, which resulted in the carbon replicas of improved adsorption and structural properties. Elemental analysis revealed the presence of nitrogen in the carbon replicas studied in the range of 3-8 wt %, whereas TG analysis of the replica samples in air gave about 2-5% residue, which was identified as hematite (Fe{sub 2}O{sub 3}). The presence of graphitic domains was confirmed by characteristic TG oxidation profile above 400 C, the D and G bands on the Raman spectra, and the intense reflections on the wide angle XRD patterns. Powder XRD also showed the presence of extra-framework magnetic iron ({alpha}-Fe) and iron carbide (Fe{sub 3}C) nanoparticles having crystallite size in the ranges of 40-80 and 20-40 nm, respectively. TEM images also revealed that these nanoparticles were larger than the carbon rods and pore widths of the SBA-15 carbon replica, which is in good agreement with the XRD-based estimation. The in situ EDS analysis of carbon rods and spheres showed that iron was present in the carbonaceous framework, which does not exclude the existence of much smaller nanoparticles, below 5 nm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial control of heavy-fermion superconductivity in CeIrIn 5

While crystals of strongly correlated metals exhibit a diverse set of electronic ground states, few approaches exist for spatially modulating their properties. In this study, we demonstrate disorder-free control, on the micrometer scale, over the superconducting state in samples of the heavy-fermion superconductor CeIrIn 5 . We pattern crystals by focused ion beam milling to tailor the boundary conditions for the elastic deformation upon thermal contraction during cooling. The resulting nonuniform strain fields induce complex patterns of superconductivity, owing to the strong dependence of the transition temperature on the strength and direction of strain. These findings showcase a generic approach to manipulating electronic order on micrometer length scales in strongly correlated matter without compromising the cleanliness, stoichiometry, or mean free path.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and Characterization of Sol–Gel Auto Combustion-Derived Ce/Zr-Substituted Strontium Hexaferrite Nanoparticles

In this work, Ce/Zr-substituted strontium hexaferrite (SrFe{sub 12}O{sub 19}) nanoparticles have been synthesized by the sol–gel auto combustion method and the synthesized samples were annealed at 900 {sup ∘}C for 3 h. The powder XRD pattern revealed that all the diffraction peaks match the hexagonal phase of strontium hexaferrite and the lattice parameters are determined. The VSM study revealed that the values of saturation magnetization, coercivity and remanent magnetization are decreased for the Ce/Zr-substituted strontium hexaferrite sample. Thermal analysis reveals the formation of a hexagonal phase above 670 {sup ∘}C. The specific vibration band of hexagonal ferrite was observed in the range 400–600 cm{sup −1}. The FE-SEM image shows that the particles are spherical shaped and particle size varied from 37 to 44 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and electrochemical behavior of nanostructured cauliflower-shape Co-Ni/Co-Ni oxides composites

Nanostructured Co-Ni/Co-Ni oxides were electrochemically deposited onto stainless steel electrode by electrochemical method and characterized for their structural and supercapacitive properties. The SEM images indicated that the obtained Co-Ni/Co-Ni oxides had cauliflower-type nanostructure. The X-ray diffraction pattern showed the formation of Co{sub 3}O{sub 4}, NiO, Co and Ni. The EDX elemental mapping images indicated that Ni, Co and O are distributed uniformly. The deposited Co-Ni/Co-Ni oxides showed good supercapacitive characteristics with a specific capacitance of 331 F/g at 1 mA/cm{sup 2} current density in 1 M KOH electrolyte. A mechanism of the formation of cauliflower-shape Co-Ni/Co-Ni oxides was proposed. A variety of promising applications in the fields such as energy storage devices and sensors can be envisioned from Co-Ni/Co-Ni oxides.

36 MATERIALS SCIENCE↗

Improving of the electrical and magnetic properties of BiFeO{sub 3} by doping with yttrium

Bismuth ferrite is one of the most promising multiferroic materials, and the main barriers for exploiting all of its specific properties are difficulties in obtaining pure, high resistive material with nanosized grains. Doping of BiFeO{sub 3} with different transition metals and rare earth elements is often used way for overcoming these obstacles. Yttrium doped bismuth ferrite, Bi{sub 1−x}Y{sub x}FeO{sub 3} (x = 0; 0.01; 0.03; 0.05; 0.1), was prepared by auto-combustion method. X-ray diffraction patterns and Raman results showed that partial phase transition from rhombohedral to orthorhombic structure took place at around 10 mol% of Y. Effect of Y doping on microstructure was studied from SEM micrographies, showing the reduction of grain size in doped samples. Electrical measurements showed continuous improvement of resistivity with Y doping, whereas the values of saturation and remnant polarizations exhibit maximums at around 5 mol% of Y. Yttrium doping also enhanced magnetic properties, leading to weak ferromagnetism.

36 MATERIALS SCIENCE↗

A Novel Polyester Fabric Treated with Nanoclay/Nano TiO{sub 2}/PAMAM for Discoloration of Reactive Red 4 from Aqueous Solution Under UVA Irradiation

Here, a commercially available absorbent with a high absorbance capacity (Cloisite{sup ®} 15A) together with the high active nano photocatalyst (AEROXIDE{sup ®} TiO{sub 2} P 25) and polyamidoamine based dendrimer (PAMAM) were immobilized on polyester fabric through simple pad-dry-cure method for removing dye from an aqueous solution. Using three components with good activities toward discoloration expected to produce a substrate with an excellent discoloration capacity. FESEM images with EDX patterns and X-ray diffraction spectra revealed the presence of nanoclay and nano TiO{sub 2} on the surface of the fabric. Discoloration of Reactive Red 4 (RR4) was carried out successfully by addition of a piece of the treated fabric in the dye solution under UVA irradiation. UV–visible spectra of the remaining solutions after discoloration indicated complete discoloration of RR4 solution for several times. The photocatalytic properties of the treated fabric was not changed after consecutive discoloration however the fabric surface was colored due to the presence of nanoclay on the surface acting as the dye absorbent. Graphical Abstract: .

36 MATERIALS SCIENCE↗

Accuracy of Proton Beam Range Verification Using Post-Treatment Positron Emission Tomography/Computed Tomography as Function of Treatment Site

Purpose: For 23 patients, an off-line positron emission tomography scan and a computed tomography scan after proton radiotherapy was performed at the Massachusetts General Hospital to assess in vivo treatment verification. A well-balanced population of patients was investigated to assess the effect of the tumor location on the accuracy of the technique. Methods and Materials: Range verification was achieved by comparing the measured positron emission tomography activity distributions with the corresponding Monte Carlo-simulated distributions. Observed differences in the distal end of the activity distributions were analyzed as potential indicators for the range differences between the actual delivered and planned dose. Results: The average spatial agreement between the measured and simulated activity distribution was within {+-}3 mm, and the corresponding average absolute agreement was within {+-}45% (derived from gamma index analysis). The mean absolute range deviation at 93 randomly chosen positions in 17 treatment fields delivered to 11 patients was 3.6 mm. Characteristic differences in the agreement of the measured and simulated activity distribution for the different tumor/target sites were found. This resulted from the different effect of factors such as biologic washout effects, motion, or limitations in the Monte Carlo-simulated activity patterns. Conclusion: We found that intracranial and cervical spine patients can greatly benefit from off-line positron emission tomography and computed tomography range verification. However, for the successful application of the method to patients with abdominopelvic tumors, major technological and methodologic improvements are needed. Among the intracranial and cervical spine target sites, patients with arteriovenous malformations or metal implants represent groups that could especially benefit from the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft chemical synthesis of Ag{sub 3}SbS{sub 3} with efficient and recyclable visible light photocatalytic properties

Highlights: • Highly crystalline Ag{sub 3}SbS{sub 3} synthesized using soft chemical approach. • First time report of photocatalytic activity of Ag{sub 3}SbS{sub 3}. • Ag{sub 3}SbS{sub 3} degraded the harmful organic dyes rapidly under visible radiation. • Pseudo first order kinetics have been followed in these sets of reactions. • Up to 90% of Methylene Blue degraded even after 4th cycle of catalyst reuse. • Structure of catalyst is intact after reuse. • As the catalyst is heavy, its separation after use is quite simple. - Abstract: Application of Ag{sub 3}SbS{sub 3}, obtained by soft chemical approach involving rapid reaction of air stable metal–thiourea complexes in ethylene glycol medium, as visible light photocatalyst for the degradation of dye solutions was investigated. Ag{sub 3}SbS{sub 3} was confirmed by high resolution powder X-ray diffraction pattern and its no defined morphology was present in SEM images. From UV–vis spectroscopy measurements, optical band gap of 1.77 eV was deduced for Ag{sub 3}SbS{sub 3}. Rapid degradation kinetics and recyclability was exhibited by Ag{sub 3}SbS{sub 3} towards Methylene Blue, Methyl Orange, Malachite Green, and Rhodamine 6G dye solutions under visible radiation. All these processes followed pseudo first order kinetics. High surface area (6.39 m{sup 2}/g), with mesopores (3.81 nm), arising from solvent mediated synthesis of Ag{sub 3}SbS{sub 3} has been correlated to its catalytic activity.

36 MATERIALS SCIENCE↗

Textured Pr{sub 2}Fe{sub 14}B flakes with submicron or nanosize thickness prepared by surfactant-assisted ball milling

The textured Pr{sub 2}Fe{sub 14}B nanoflakes were produced by surfactant-assisted ball milling (SABM). Single phase tetragonal structure was characterized for the samples before and after SABM by X-ray diffraction (XRD). The thickness and length of the as-milled flakes are mainly in the range of 50–150 nm and 0.5–2 μm, respectively. For the field-aligned Pr{sub 2}Fe{sub 14}B nanoflakes, the out-of-plane texture (the easy magnetization direction (EMD) along the c-axis) is indicated from the increasing (00l) peaks in the XRD patterns. SEM image demonstrates that the EMD is parallel to flaky surface, which is different from the RCo{sub 5} (R = rare earth) system with EMD perpendicular to the surface. We propose a hypothesis that the easy glide planes are related with the area of crystal planes. In addition, a large coercivity H{sub c} = 3.9 kOe is observed in the Pr{sub 2}Fe{sub 14}B flakes with strong texture.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-13: Six Degree of Freedom Image Fusion Accuracy for Cranial Target Localization On the Varian Edge Stereotactic Radiosurgery System: Comparison Between 2D/3D and KV CBCT Image Registration

Purpose: To determine the 6 degree of freedom systematic deviations between 2D/3D and CBCT image registration with various imaging setups and fusion algorithms on the Varian Edge Linac. Methods: An anthropomorphic head phantom with radio opaque targets embedded was scanned with CT slice thicknesses of 0.8, 1, 2, and 3mm. The 6 DOF systematic errors were assessed by comparing 2D/3D (kV/MV with CT) with 3D/3D (CBCT with CT) image registrations with different offset positions, similarity measures, image filters, and CBCT slice thicknesses (1 and 2 mm). The 2D/3D registration accuracy of 51 fractions for 26 cranial SRS patients was also evaluated by analyzing 2D/3D pre-treatment verification taken after 3D/3D image registrations. Results: The systematic deviations of 2D/3D image registration using kV- kV, MV-kV and MV-MV image pairs were within ±0.3mm and ±0.3° for translations and rotations with 95% confidence interval (CI) for a reference CT with 0.8 mm slice thickness. No significant difference (P>0.05) on target localization was observed between 0.8mm, 1mm, and 2mm CT slice thicknesses with CBCT slice thicknesses of 1mm and 2mm. With 3mm CT slice thickness, both 2D/3D and 3D/3D registrations performed less accurately in longitudinal direction than thinner CT slice thickness (0.60±0.12mm and 0.63±0.07mm off, respectively). Using content filter and using similarity measure of pattern intensity instead of mutual information, improved the 2D/3D registration accuracy significantly (P=0.02 and P=0.01, respectively). For the patient study, means and standard deviations of residual errors were 0.09±0.32mm, −0.22±0.51mm and −0.07±0.32mm in VRT, LNG and LAT directions, respectively, and 0.12°±0.46°, −0.12°±0.39° and 0.06°±0.28° in RTN, PITCH, and ROLL directions, respectively. 95% CI of translational and rotational deviations were comparable to those in phantom study. Conclusion: 2D/3D image registration provided on the Varian Edge radiosurgery, 6 DOF-based system provides accurate target positioning for frameless image-guided cranial stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

Microstructural characterization of amorphous and nanocrystalline boron nitride prepared by high-energy ball milling

Microstructural parameters like crystallite size, lattice strain, stacking faults and dislocation density were evaluated from the X-ray diffraction data of boron nitride (BN) powder milled in a high-energy vibrational ball mill for different length of time (2-120 h), using different model based approaches like Scherrer analysis, integral breadth method, Williamson-Hall technique and modified Rietveld technique. From diffraction line-broadening analysis of the successive patterns of BN with varying milling time, it was observed that overall line broadening was an operative cause for crystallite size reduction at lower milling time ({approx}5 h), whereas lattice strains were the prominent cause of line broadening at higher milling times (>19 h). For intermediate milling time (7-19 h), both crystallite size and lattice strain influence the profile broadening although their relative contribution vary with milling time. Microstructural information showed that after long time milling (>19 h) BN becomes mixture of nanocrystalline and amorphous BN. The accumulations of defects cause this crystalline to amorphous transition. It has been found that twin fault ({beta}') and deformation fault ({alpha}) significantly contributed to BN powder as synthesized by a high-energy ball-milling technique. Present study consider only three ball-milled (0, 2 and 3 h) BN powder for faults calculation because fault effected reflections (1 0 1, 1 0 2, 1 0 3) disappear with milling time (>3 h). The morphology and particle size of the BN powders before and after ball milling were also observed in a field emission scanning electron microscope (FESEM)

36 MATERIALS SCIENCE↗

SU-E-J-27: Shifting Multiple EPID Imager Layers to Improve Image Quality and Resolution in MV CBCT

Purpose: Vertical stacking of four conventional EPID layers can improve DQE for MV-CBCT applications. We hypothesize that shifting each layer laterally by half a pixel relative to the layer above, will improve the contrast-to-noise ratio (CNR) and image resolution. Methods: For CNR assessment, a 20 cm diameter digital phantom with 8 inserts is created. The attenuation coefficient of the phantom is similar to lung at the average energy of a 6 MV photon beam. The inserts have attenuations 1, 2…8 times of lung. One of the inserts is close to soft tissue, resembling the case of a tumor in lung. For resolution assessment, a digital phantom featuring a bar pattern is created. The phantom has an attenuation coefficient similar to soft tissue and the bars have an attenuation coefficient of calcium sulfate. A 2 MeV photon beam is attenuated through these phantoms and hits each of the four stacked detector layers. Each successive layer is shifted by half a pixel in the x only, y only, and x and y (combined) directions, respectively. Blurring and statistical noise are added to the projections. Projections from one, two, three and four layers are used for reconstruction. CNR and image resolution are evaluated and compared. Results: When projections from multiple layers are combined for reconstruction, CNR increases with the number of layers involved. CNR in reconstructions from two, three and four layers are 1.4, 1.7 and 1.99 times that from one layer. The resolution from the shifted four layer detector is also improved from a single layer. In a comparison between one layer versus four layers in this preliminary study, the resolution from four shifted layers is at least 20% better. Conclusion: Layer-shifting in a stacked EPID imager design enhances resolution as well as CNR for half scan MV-CBCT. The project described was supported, in part, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Synthesis and characterization of nanocrystalline Zn ferrites substituted with Ni

Highlights: {yields} Ni{sub x}Zn{sub 1-x}Fe{sub 2}O{sub 4} are synthesized by sol-gel auto-combustion method using tartaric acid. {yields} XRD patterns reveal spinel structure and the crystallite size is max. 40 nm. {yields} SEM images for Ni{sub 0.6}Zn{sub 0.4}Fe{sub 2}O{sub 4} confirm the nano-scale crystallite size. {yields} The highest value of samples porosity belongs to Ni{sub 0.6}Zn{sub 0.4}Fe{sub 2}O{sub 4}. {yields} The maximum value of the magnetization is 63 emu/g for Ni{sub 0.8}Zn{sub 0.2}Fe{sub 2}O{sub 4}. -- Abstract: Nanocrystalline powders of nickel substituted zinc ferrite with general formula Ni{sub x}Zn{sub 1-x}Fe{sub 2}O{sub 4} (x = 0, 0.2, 0.4, 0.6, 0.8, 1) have been synthesized via sol-gel auto-combustion method using tartaric acid as combustion-complexing agent. Samples were sintered at 773 K and 973 K in static air atmosphere. The absence of the organic phase and the spinel formation were monitored by using Fourier transform infrared spectroscopy. The structure and crystallite size were analyzed from X-ray diffraction data revealing spinel mono-phase formation in the range of nanometric crystallite size confirmed also through scanning electron microscopy. Mean size of crystallites lay in the range 20-40 nm. The influence of nickel content on the microstructure was investigated considering the crystallite size, distance between adjacent crystal planes, lattice parameter and porosity. The variation of magnetic properties of the samples was studied by using vibrating samples magnetometer and discussed considering the proposed cation distribution, relative bond angles and canting angles. The highest maximum value of the magnetization (63 emu/g) was found for Ni{sub 0.8}Zn{sub 0.2}Fe{sub 2}O{sub 4}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗