Search NASA⌕ Search

SEARCH · Search NASA

Results for “source injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

NASA Operational Simulator for Small Satellites: Tools for Software Based Validation and Verification of Small Satellites

The NASA Operational Simulator for Small Satellites (NOS3) is a suite of tools to aid in areas such as software development, integration test (IT), mission operations training, verification and validation (VV), and software systems check-out. NOS3 provides a software development environment, a multi-target build system, an operator interface-ground station, dynamics and environment simulations, and software-based hardware models. NOS3 enables the development of flight software (FSW) early in the project life cycle, when access to hardware is typically not available. For small satellites there are extensive lead times on many of the commercial-off-the-shelf (COTS) components as well as limited funding for engineering test units (ETU). Considering the difficulty of providing a hardware test-bed to each developer tester, hardware models are modeled based upon characteristic data or manufacturers data sheets for each individual component. The fidelity of each hardware models is such that FSW executes unaware that physical hardware is not present. This allows binaries to be compiled for both the simulation environment, and the flight computer, without changing the FSW source code. For hardware models that provide data dependent on the environment, such as a GPS receiver or magnetometer, an open-source tool from NASA GSFC (42 Spacecraft Simulation) is used to provide the necessary data. The underlying infrastructure used to transfer messages between FSW and the hardware models can also be used to monitor, intercept, and inject messages, which has proven to be beneficial for VV of larger missions such as James Webb Space Telescope (JWST). As hardware is procured, drivers can be added to the environment to enable hardware-in-the-loop (HWIL) testing. When strict time synchronization is not vital, any number of combinations of hardware components and software-based models can be tested. The open-source operator interface used in NOS3 is COSMOS from Ball Aerospace. For testing, plug-ins are implemented in COSMOS to control the NOS3 simulations, while the command and telemetry tools available in COSMOS are used to communicate with FSW. NOS3 is actively being used for FSW development and component testing of the Simulation-to-Flight 1 (STF-1) CubeSat. As NOS3 matures, hardware models have been added for common CubeSat components such as Novatel GPS receivers, ClydeSpace electrical power systems and batteries, ISISpace antenna systems, etc. In the future, NASA IVV plans to distribute NOS3 to other CubeSat developers and release the suite to the open-source community.

Verification↗

How Many Muons Do We Need to Store in a Ring For Neutrino Cross-Section Measurements?

Analytical estimate of the number of muons that must decay in the straight section of a storage ring to produce a neutrino & anti-neutrino beam of sufficient intensity to facilitate cross-section measurements with a statistical precision of 1%. As we move into the era of precision long-baseline {nu}{sub {mu}} {yields} {nu}{sub e} and {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e} measurements there is a growing need to precisely determine the {nu}{sub e} and {bar {nu}}{sub e} cross-sections in the relevant energy range, from a fraction of 1 GeV to a few GeV. This will require {nu}{sub e} and {bar {nu}}{sub e} beams with precisely known fluxes and spectra. One way to produce these beams is to use a storage ring with long straight sections in which muon decays ({mu}{sup -} {yields} e{sup -}{nu}{sub {mu}}{bar {nu}}{sub e} if negative muons are stored, and {nu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} if positive muons are stored) produce the desired beam. The challenge is to capture enough muons in the ring to obtain useful neutrino and anti-neutrino fluxes. Early proposals to use a muon storage ring for neutrino oscillation experiments were based upon injecting 'high energy' charged pions into the ring which then decayed to create stored muons. These proposals were hampered by lack of sufficient intensity to pursue the physics. The Neutrino Factory proposal in 1997 was designed to fix this problem by using a Muon Collider class 'low energy' muon source to capture many more pions at low energy, allow them to decay in an external decay channel, manipulate their phase space to capture as many muons as possible within the acceptance of an accelerator, and then accelerate to the energy of choice before injecting into a specially designed ring with long straight sections. All this technology would do a wonderful job in fixing the intensity problem, but at a price that excludes this solution from being realized in the short term. The question that we are now faced with is whether the older, lower intensity 'parasitic' muon storage ring based on 'high energy' pion decays can, with suitable modification, produce sufficient intensity to measure the desired cross-sections. Fortunately, the intensity requirements for cross-section measurements are less demanding than the corresponding requirements for oscillation measurements, so there is hope. To fuel the discussion, in this note we consider the design goal: how many muons do we need to store?

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

54 ENVIRONMENTAL SCIENCES↗

Developing methanogenic microbial consortia from diverse coal sources and environments

Biogenic gas production is a promising alternative or supplement to conventional methane extraction from coalbeds. Adsorbed and free gas, generated over geologic time, can be supplemented with biogenic gas during short-term engineering operations. There are two generic protocols for doing this. The first is to contact the coal with nutrients to support native bacterial development. The second approach is to inject appropriately cultured ex-situ consortia into subsurface coal accumulations. Research has mainly focused on the former: in-situ stimulation of native microbial communities with added nutrients. Relatively few studies have been conducted on the strategies for enriching ex-situ microbial populations under initial atmospheric exposure for subsequent injection into coal seams to stimulate biodegradation, and methanogenesis. In order to evaluate the feasibility of ex-situ cultivation, natural microbial populations were collected from various hydrocarbon-rich environments and locations characterized by natural methanogenesis. Different rank coals (i.e., lignite, sub-bituminous, bituminous), complex hydrocarbon sources (i.e., oil shale, waxy crude), hydrocarbon seeps, and natural biogenic environments were incorporated in the sampling. Three levels of screening (down-selection to high grade the most productive consortia) allowed selection of microbial populations, favorable nutrient amendments, sources of the microbial community, and quantification of methane produced from various coal types. Incubation periods of up to twenty-four weeks were evaluated at 23 °C. Headspace concentrations of CH 4 and CO 2 were analyzed by gas chromatography. After a two-week incubation period of the most promising microbes, generated headspace gas concentrations reached 873,400 ppm (154 sft 3 /ton or 4.8 scm 3 /g) for methane and 176,370 ppm (31 sft 3 /ton or 0.9 scm 3 /g) for carbon dioxide. Rudimentary statistical assessments – variance analysis (ANOVA) of a single factor - were used to identify trends and levels of significance or impact of the consortia enrichment. We then demonstrated that microbial communities from coal and lake sediments can be enriched and adapted to effectively generate methane under initial atmospheric exposure. The development and enrichment of these methanogenic consortia is described.

01 COAL, LIGNITE, AND PEAT↗

Effect of CoFe insertion in Co{sub 2}MnSi/CoFe/n-GaAs junctions on spin injection properties

The CoFe thickness (t{sub CoFe}) dependence of spin injection efficiency was investigated for Co{sub 2}MnSi/CoFe/n-GaAs junctions. The ΔV{sub NL}/I value, which is a measure of spin injection efficiency, strongly depended on t{sub CoFe}, where ΔV{sub NL} is the amplitude of a nonlocal spin-valve signal, and I is an injection current. Importantly, the maximum value of ΔV{sub NL}/I for a Co{sub 2}MnSi/CoFe/n-GaAs junction was one order of magnitude higher than that for a CoFe/n-GaAs junction, indicating that a Co{sub 2}MnSi electrode works as a highly polarized spin source. No clear spin signal, on the other hand, was observed for a Co{sub 2}MnSi/n-GaAs junction due to diffusion of Mn atoms into the GaAs channel. Secondary ion mass spectrometry analysis indicated that the CoFe insertion effectively suppressed the diffusion of Mn into GaAs, resulting in improved spin injection properties compared with those for a Co{sub 2}MnSi/n-GaAs junction.

36 MATERIALS SCIENCE↗

SpotSDC: Revealing the Silent Data Corruption Propagation in High-Performance Computing Systems

We report the trend of rapid technology scaling is expected to make the hardware of high-performance computing (HPC) systems more susceptible to computational errors due to random bit flips. Some bit flips may cause a program to crash or have a minimal effect on the output, but others may lead to silent data corruption (SDC), i.e., undetected yet significant output errors. Classical fault injection analysis methods employ uniform sampling of random bit flips during program execution to derive a statistical resiliency profile. However, summarizing such fault injection result with sufficient detail is difficult, and understanding the behavior of the fault-corrupted program is still a challenge. In this article, we introduce SpotSDC, a visualization system to facilitate the analysis of a program's resilience to SDC. SpotSDC provides multiple perspectives at various levels of detail of the impact on the output relative to where in the source code the flipped bit occurs, which bit is flipped, and when during the execution it happens. SpotSDC also enables users to study the code protection and provide new insights to understand the behavior of a fault-injected program. Based on lessons learned, we demonstrate how what we found can improve the fault injection campaign method.

97 MATHEMATICS AND COMPUTING↗

Microtomography and pore-scale modeling of two-phase Fluid Distribution

Synchrotron-based X-ray microtomography (micro CT) at the Advanced Light Source (ALS) line 8.3.2 at the Lawrence Berkeley National Laboratory produces three-dimensional micron-scale-resolution digital images of the pore space of the reservoir rock along with the spacial distribution of the fluids. Pore-scale visualization of carbon dioxide flooding experiments performed at a reservoir pressure demonstrates that the injected gas fills some pores and pore clusters, and entirely bypasses the others. Using 3D digital images of the pore space as input data, the method of maximal inscribed spheres (MIS) predicts two-phase fluid distribution in capillary equilibrium. Verification against the tomography images shows a good agreement between the computed fluid distribution in the pores and the experimental data. The model-predicted capillary pressure curves and tomography-based porosimetry distributions compared favorably with the mercury injection data. Thus, micro CT in combination with modeling based on the MIS is a viable approach to study the pore-scale mechanisms of CO{sub 2} injection into an aquifer, as well as more general multi-phase flows.

54 ENVIRONMENTAL SCIENCES↗

The Integration and Mapping of an Open-Source National Well Resource to Inform Geologic Carbon Storage Site Selection and Risk Prevention: The CO2-Locate Database

Geologic carbon storage (GCS) offers a way to capture and permanently store CO₂ from fossil fuel operations in underground geologic structures, aiding in the transition to a carbon-neutral energy economy. However, CO₂ injection sites can experience gas leakage through existing wells that penetrate storage reservoirs, making knowledge of well locations and characteristics crucial for permitting, infrastructure reusability, and risk assessment in GCS. Currently, public wellbore data from state, federal, and tribal entities are inconsistent and fragmented, with gaps and redundancies. To address this, the National Energy Technology Laboratory (NETL) developed CO2-Locate, an open-source, geospatial database and online application. CO2-Locate integrates over 50 data sources from federal, state, and tribal entities, creating a standardized national well database. Funded by the Bipartisan Infrastructure Law, the database is publicly available through the Energy Data eXchange (EDX) and viewable via the CO2-Locate web mapping application. This tool allows users to query, filter, and visualize well data to support GCS planning, permitting, and risk assessments. This presentation covers the methods used to create CO2-Locate, including data acquisition, processing, attribute mapping, and integration, much of which is automated for future updates. The web mapping application and its role in GCS site selection will also be discussed.

Tetteh, Daniel A.↗

Numerical Analysis of the Source of Excessive Na + and Cl – Species in Flowback Water From Hydraulically Fractured Shale Formations

Fracture fluid comprises fresh water, proppant, and a small percentage of other additives, which support the hydraulic fracturing process. Excluding situations in which flowback water is recycled and reused, total dissolve solids in fracture fluid is limited to the fluid additives, such as potassium chloride (1-7 weight percent KCL), which is used as a clay stabilizer to minimize clay swelling, and clay particle migration. However, the composition of recovered fluid, especially as it relates to the total dissolve solids (TDS), is always substantially different than the injected fracture fluid. The ability to predict flowback water volume and composition is useful when planning for the management or reuse of this aqueous byproduct stream. In this work, an ion transport and halite dissolution model was coupled with a fully implicit, dual porosity, numerical simulator, to study the source of the excess solutes in flowback water, and to predict the concentration of both Na+ and Cl- species seen in recovered water. The results showed that mixing alone, between the injected fracture fluid and concentrated in situ formation brine, could not account for the substantial rise in TDS seen in flowback water. Instead, the results proved that halite dissolution is a major contributor to the change in TDS seen in fracture fluid during injection and recovery. Halite dissolution can account for as much as 81% of Cl- and 86.5% of Na+ species seen in 90-day flowback water; mixing, between the injected fracture fluid and in situ concentrated brine, accounts for approximately 19% Cl- and 13% Na+.

03 NATURAL GAS↗

Proton Injector for CW-Mode Linear Accelerators

Numerous applications exist for CW linear accelerators with final energies in the 0.5 to 4.0 MeV proton energy range. Typical proton current at the linac output energy is 20 mA. An important subsystem for the accelerator facility is a reliable dc mode proton injector. We present here design and laboratory results for a dc, 25-keV, 30-mA proton injector. The proton source is a 2.45-GHz microwave hydrogen ion source which operates with an 875-G axial magnetic field. Low emittance, high proton fraction (>85%), beams have been demonstrated from this source. The injector uses a novel dual-solenoid magnet for matching the injector beam into a radio frequency quadrupole (RFQ) linear accelerator. Recently, a dc ion-source development program has given up to 30 mA beam current. The dual solenoid is a compact and simple design utilizing tape-wound, edge-cooled coils. The low-energy beam transport design as well as 25-keV beam matching calculations to an RFQ will also be presented.

43 PARTICLE ACCELERATORS↗

Evaluation of the spline reconstruction technique for PET

Purpose: The spline reconstruction technique (SRT), based on the analytic formula for the inverse Radon transform, has been presented earlier in the literature. In this study, the authors present an improved formulation and numerical implementation of this algorithm and evaluate it in comparison to filtered backprojection (FBP). Methods: The SRT is based on the numerical evaluation of the Hilbert transform of the sinogram via an approximation in terms of “custom made” cubic splines. By restricting reconstruction only within object pixels and by utilizing certain mathematical symmetries, the authors achieve a reconstruction time comparable to that of FBP. The authors have implemented SRT in STIR and have evaluated this technique using simulated data from a clinical positron emission tomography (PET) system, as well as real data obtained from clinical and preclinical PET scanners. For the simulation studies, the authors have simulated sinograms of a point-source and three digital phantoms. Using these sinograms, the authors have created realizations of Poisson noise at five noise levels. In addition to visual comparisons of the reconstructed images, the authors have determined contrast and bias for different regions of the phantoms as a function of noise level. For the real-data studies, sinograms of an{sup 18}F-FDG injected mouse, a NEMA NU 4-2008 image quality phantom, and a Derenzo phantom have been acquired from a commercial PET system. The authors have determined: (a) coefficient of variations (COV) and contrast from the NEMA phantom, (b) contrast for the various sections of the Derenzo phantom, and (c) line profiles for the Derenzo phantom. Furthermore, the authors have acquired sinograms from a whole-body PET scan of an {sup 18}F-FDG injected cancer patient, using the GE Discovery ST PET/CT system. SRT and FBP reconstructions of the thorax have been visually evaluated. Results: The results indicate an improvement in FWHM and FWTM in both simulated and real point-source studies. In all simulated phantoms, the SRT exhibits higher contrast and lower bias than FBP at all noise levels, by increasing the COV in the reconstructed images. Finally, in real studies, whereas the contrast of the cold chambers are similar for both algorithms, the SRT reconstructed images of the NEMA phantom exhibit slightly higher COV values than those of FBP. In the Derenzo phantom, SRT resolves the 2-mm separated holes slightly better than FBP. The small-animal and human reconstructions via SRT exhibit slightly higher resolution and contrast than the FBP reconstructions. Conclusions: The SRT provides images of higher resolution, higher contrast, and lower bias than FBP, by increasing slightly the noise in the reconstructed images. Furthermore, it eliminates streak artifacts outside the object boundary. Unlike other analytic algorithms, the reconstruction time of SRT is comparable with that of FBP. The source code for SRT will become available in a future release of STIR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological System Characterization to Address Biofouling of the 200 West Pump-and-Treat Injection Wells

Contaminated groundwater in the 200W Area of the Hanford Site is being treated ex situ by the 200W Pump-and-Treat (P&T) Facility and the subsurface plume is under hydraulic containment. The 200W P&T Facility removes several contaminants of concern from groundwater, as well as nitrate. Facility capacity is constrained by biofouling of injection wells, which limits the ability to efficiently inject treated effluent water in to the subsurface. In a previous report, Thomle et al. provided a comprehensive engineering assessment of biofouling at the 200W P&T Facility. In that report, both operational changes and facility modifications were recommended to help mitigate the symptoms and consequences of biofouling by expanding treatment processes in the plant. The 200W P&T Facility’s fluidized bed reactor (FBR) is a biological treatment system that has been identified as a principal source of biofouling. Carbon and nutrient inputs to the FBR are needed to sustain high rates of activity, but can also be responsible for microbial proliferation in the effluent water distribution pipeline, and loss injection well capacity. The primary objective of this work was to fill critical knowledge gaps associated with the FBR that can be used to optimize the biological system for continuous operation and sustained performance.

54 ENVIRONMENTAL SCIENCES↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

RF undulator for compact X-ray SASE source of variable wavelength

A room-temperature RF undulator, fed by Ka-band radiation and intended to produce {approx}1 nm wavelength radiation using moderate energy electrons, is considered. The necessary electron bunches with energy 0.2-1 GeV could be produced by petawatt laser pulses injected into plasma bubbles.

43 PARTICLE ACCELERATORS↗

Investigating the Combustion Performance of Dual Fuel Combustion with Diesel and Port Injected Hydrogen in a Large Bore Locomotive Engine

The heavy-duty transportation sector has primarily relied on conventional diesel combustion engines given their reliability and high thermal efficiency relative to spark ignition engines, but increased focus on reducing greenhouse gas emissions has led to investigation into alternative fuels. Gaseous hydrogen fuel has garnered a great deal of recent interest in the engine community given it has zero carbon, but hydrogen is not available at the scale and cost that petroleum fuels are currently available, and this is a barrier to adoption for industries that are looking to decarbonize their operations. Because of the fuel flexibility provided, dual fuel technology offers a pathway for some industries to adopt hydrogen as a fuel source while maintaining sufficient flexibility in times and locations where the new fuel is not yet available. This computational study investigates dual fuel combustion in a large bore locomotive engine architecture using direct injected diesel and port injected gaseous hydrogen fuel. With an optimal port fuel injection configuration from previous work, simulations of varying substitution ratio, compression ratio, manifold air temperature, diesel injection timing, and diesel injection pressure were performed to understand their effect on combustion performance. Results indicated that both increased substitution ratio and higher intake air temperature accelerates hydrogen flame propagation and can result in high peak cylinder pressures. Additionally, diesel injection timing and injection pressure were demonstrated as effective methods for controlling dual fuel combustion heat release rates.

ODonnell, Patrick Christopher↗

Ultra-luminous X-ray sources in Haro 11 and the role of X-ray binaries in feedback in Lyα emitting galaxies

Lyman Break Analogs (LBAs) are local proxies of high-redshift Lyman Break Galaxies. Spatially resolved studies of nearby starbursts have shown that Lyman continuum and line emission are absorbed by dust and that the Lyα is resonantly scattered by neutral hydrogen. In order to observe Lyα emission from star-forming regions, some source of feedback is required to blow the neutral gas away from the starburst to prevent scattering and allow the Lyα emission to escape. We show that there are two X-ray point sources embedded in the diffuse emission of the LBA galaxy Haro 11. CXOU J003652.4-333316 (abbreviated to Haro 11 X-1) is an extremely luminous (L{sub X}∼10{sup 41} erg s{sup −1}), spatially compact source with a hard-X-ray spectrum. We suggest that the X-ray emission from Haro 11 X-1 is dominated by a single accretion source. This might be an active galactic nucleus or a source similar to the extreme black hole binary (BHB) M82 X-1. The hard X-ray spectrum indicates that Haro 11 X-1 may be a BHB in a low accretion state. In this case, the very high X-ray luminosity suggests an intermediate mass black hole that could be the seed for formation of a supermassive black hole. Source CXOU J003652.7-33331619.5 (abbreviated Haro 11 X-2) has an X-ray luminosity of L{sub X}∼5×10{sup 40} erg s{sup −1} and a soft X-ray spectrum (power-law photon index Γ ∼ 2.2). This strongly suggests that Haro 11 X-2 is an X-ray binary in the ultra luminous state (i.e., an Ultra Luminous X-ray source, ULX). Haro 11 X-2 is coincident with the star-forming knot that is the source of the Lyα emission. The association of a ULX with Lyα emission raises the possibility that strong winds from X-ray binaries play an important role in injecting mechanical power into the interstellar medium, thus blowing away neutral material from the starburst region and allowing the Lyα to escape. We suggest that feedback from X-ray binaries may play a significant role in allowing Lyα emission to escape from galaxies in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Residual-gas-ionization beam profile monitors in RHIC

Four ionization profile monitors (IPMs) are in RHIC to measure vertical and horizontal beam profiles in the two rings. These work by measuring the distribution of electrons produced by beam ionization of residual gas. During the last two years both the collection accuracy and signal/noise ratio have been improved. An electron source is mounted across the beam pipe from the collector to monitor microchannel plate (MCP) aging and the signal electrons are gated to reduce MCP aging and to allow charge replenishment between single-turn measurements. Software changes permit simultaneous measurements of any number of individual bunches in the ring. This has been used to measure emittance growth rates on six bunches of varying intensities in a single store. Also the software supports FFT analysis of turn-by-turn profiles of a single bunch at injection to detect dipole and quadrupole oscillations.

43 PARTICLE ACCELERATORS↗

Frequency of Atrial Septal Aneurysms in Patients with Cerebral Ischemic Events

Background-Atrial septal aneurysm (ASA) is a putative risk factor for cardioembolism. However, the frequency of ASA in the general population has not been adequately determined. Therefore, the frequency in patients with cerebral ischemic events, compared with the frequency in the general population, is poorly defined. We sought to determine the frequency of ASA in the general population and to compare the frequency of ASA in patients with cerebral ischemic events with the frequency in the general population. Methods and Results-The frequency of ASA in the population was determined in 363 subjects, a sample of the participants in the Stroke Prevention: Assessment of Risk in a Community study (control subjects), and was compared with the frequency in 355 age- and sex-matched patients undergoing transesophageal echocardiography in search of a cardiac source of embolism after a focal cerebral ischemic event. The proportion with ASA was 7.9% in patients versus 2.2% in control subjects (P=0.002; odds ratio of ASA, 3.65; 95% CI, 1.64 to 8.13, in patients versus control subjects). Patent foramen ovale (PFO) was detected with contrast injections in 56% of subjects with ASA. The presence of ASA predicted the presence of PFO (odds ratio of PFO, 4.57; 95% CI, 2.18 to 9.57, in subjects with versus those without ASA). In 86% of subjects with ASA and cerebral ischemia, transesophageal echocardiography did not detect an alternative source of cardioembolism other than an associated PFO. Conclusions-The prevalence of ASA based on this population-based study is 2.2%. The frequency of ASA is relatively higher in patients evaluated with transesophageal echocardiography after a cerebral ischemic event. ASA is frequently associated with PFO, suggesting paradoxical embolism as a mechanism of cardioembolism. In patients with cerebral ischemia and ASA, ASA (with or without PFO) commonly is the only potential cardioembolic source detected with transesophageal echocardiography.

Agmon, Yoram↗