Search NASA⌕ Search

SEARCH · Search NASA

Results for “target variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Experimental impacts into Teflon targets and LDEF thermal blankets

The Long Duration Exposure Facility (LDEF) exposed approximately 20 sq m of identical thermal protective blankets, predominantly on the Ultra-Heavy Cosmic Ray Experiment (UHCRE). Approximately 700 penetration holes greater than 300 micron in diameter were individually documented, while thousands of smaller penetrations and craters occurred in these blankets. As a result of their 5.7 year exposure and because they pointed into a variety of different directions relative to the orbital motion of the nonspinning LDEF platform, these blankets can reveal important dynamic aspects of the hypervelocity particle environment in near-earth orbit. The blankets were composed of an outer teflon layer (approximately 125 micron thick), followed by a vapor-deposited rear mirror of silver (less than 1000 A thick) that was backed with an organic binder and a thermal protective paint (approximately 50 to 75 micron thick), resulting in a cumulative thickness (T) of approximately 175 to 200 microns for the entire blanket. Many penetrations resulted in highly variable delaminations of the teflon/metal or metal/organic binder interfaces that manifest themselves as 'dark' halos or rings, because of subsequent oxidation of the exposed silver mirror. The variety of these dark albedo features is bewildering, ranging from totally absent, to broad halos, to sharp single or multiple rings. Over the past year experiments were conducted over a wide range of velocities (i.e., 1 to 7 km/s) to address velocity dependent aspects of cratering and penetrations of teflon targets. In addition, experiments were performed with real LDEF thermal blankets to duplicate the LDEF delaminations and to investigate a possible relationship of initial impact conditions on the wide variety of dark halo and ring features.

Hoerz, F.↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Animal Protection and Structural Studies of a Consensus Sequence Vaccine Targeting the Receptor Binding Domain of the Type IV Pilus of Pseudomonas aeruginosa

One of the main obstacles in the development of a vaccine against Pseudomonas aeruginosa is the requirement that it is protective against a wide range of virulent strains. We have developed a synthetic-peptide consensus-sequence vaccine (Cs1) that targets the host receptor-binding domain (RBD) of the type IV pilus of P. aeruginosa. Here, we show that this vaccine provides increased protection against challenge by the four piliated strains that we have examined (PAK, PAO, KB7 and P1) in the A.BY/SnJ mouse model of acute P. aeruginosa infection. To further characterize the consensus sequence, we engineered Cs1 into the PAK monomeric pilin protein and determined the crystal structure of the chimeric Cs1 pilin to 1.35 {angstrom} resolution. The substitutions (T130K and E135P) used to create Cs1 do not disrupt the conserved backbone conformation of the pilin RBD. In fact, based on the Cs1 pilin structure, we hypothesize that the E135P substitution bolsters the conserved backbone conformation and may partially explain the immunological activity of Cs1. Structural analysis of Cs1, PAK and K122-4 pilins reveal substitutions of non-conserved residues in the RBD are compensated for by complementary changes in the rest of the pilin monomer. Thus, the interactions between the RBD and the rest of the pilin can either be mediated by polar interactions of a hydrogen bond network in some strains or by hydrophobic interactions in others. Both configurations maintain a conserved backbone conformation of the RBD. Thus, the backbone conformation is critical in our consensus-sequence vaccine design and that cross-reactivity of the antibody response may be modulated by the composition of exposed side-chains on the surface of the RBD. This structure will guide our future vaccine design by focusing our investigation on the four variable residue positions that are exposed on the RBD surface.

08 HYDROGEN↗

Planning Target Volume D95 and Mean Dose Should Be Considered for Optimal Local Control for Stereotactic Ablative Radiation Therapy

Purpose: To identify the optimal dose parameters predictive for local/lobar control after stereotactic ablative radiation therapy (SABR) in early-stage non-small cell lung cancer (NSCLC). Methods and Materials: This study encompassed a total of 1092 patients (1200 lesions) with NSCLC of clinical stage T1-T2 N0M0 who were treated with SABR of 50 Gy in 4 fractions or 70 Gy in 10 fractions, depending on tumor location/size, using computed tomography-based heterogeneity corrections and a convolution superposition calculation algorithm. Patients were monitored by chest CT or positron emission tomography/CT and/or biopsy after SABR. Factors predicting local/lobar recurrence (LR) were determined by competing risk multivariate analysis. Continuous variables were divided into 2 subgroups at cutoff values identified by receiver operating characteristic curves. Results: At a median follow-up time of 31.7 months (interquartile range, 14.8-51.3 months), the 5-year time to local recurrence within the same lobe and overall survival rates were 93.8% and 44.8%, respectively. Total cumulative number of patients experiencing LR was 40 (3.7%), occurring at a median time of 14.4 months (range, 4.8-46 months). Using multivariate competing risk analysis, independent predictive factors for LR after SABR were minimum biologically effective dose (BED{sub 10}) to 95% of planning target volume (PTVD95 BED{sub 10}) ≤86 Gy (corresponding to PTV D95 physics dose of 42 Gy in 4 fractions or 55 Gy in 10 fractions) and gross tumor volume ≥8.3 cm{sup 3}. The PTVmean BED{sub 10} was highly correlated with PTVD95 BED{sub 10.} In univariate analysis, a cutoff of 130 Gy for PTVmean BED{sub 10} (corresponding to PTVmean physics dose of 55 Gy in 4 fractions or 75 Gy in 10 fractions) was also significantly associated with LR. Conclusions: In addition to gross tumor volume, higher radiation dose delivered to the PTV predicts for better local/lobar control. We recommend that both PTVD95 BED{sub 10} >86 Gy and PTVmean BED{sub 10} >130 Gy should be considered for SABR plan optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Economics of new molecular targeted personalized radiopharmaceuticals

We report that Nuclear Medicine has come a long way since 2007 when Adrian Nunn pointed out the approval of radiopharmaceuticals was at an all-time low with all the major radiopharmaceutical agents in use having been approved over 10 years ago. Challenges being the prohibitively high cost of drug development and the large number of drugs failing in clinical trials. Proceed to today where Molecular imaging is fast-tracking the drug discovery process by reducing both the time and cost to screen candidates by quantitating the drugs effect on the target and toxicity to normal tissues. Additionally, nuclear medicine is now leading medical practice in personalized medicine using the theragnostic approach. Theragnostics is defined as the use of molecular diagnostic techniques in real-time to stratify patients to guide treatment decisions such as the choice of drug, the dose of administration and the timing of drug delivery for a given patient. Enabling visualization and quantitation of in vivo function of the whole body and thus patient heterogeneity and variability informs the physician on how to treat an individual patient. Recent successes such as the FDA approval of Luta Thera® and NETSPOT™ have resulted in an increasing number of pharmaceutical companies pursing theragnostics further heightened by the purchase of Advanced Accelerator Applications for 3.9 billion by Novartis and Endocyte, Inc for 2.1 billion. Theragnostics are further aiding drug development by showing which agents are most viable and reducing the overall cost of bringing a drug to clinical trials and regulatory approval. This is indeed a renaissance for nuclear medicine in which the acceptance of imaging to inform and monitor therapy has been embraced and even required by the FDA for the clinical evaluation of targeted therapeutic radiopharmaceuticals showing there is indeed a viable business model for targeted theragnostic radiopharmaceuticals and personalized medicine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Semi-automated Filtration Method for Non-targeted LC-QTOF Data of Aged Nitroplasticizer Samples

A full dataset of aged nitroplasticizer (NP) is composed of more than 2000 unique mass-to-charges (m/z) when combining the non-targeted data obtained from both positive and negative electrospray ionization modes in time-of-flight mass spectrometry. Therefore, manual processing of these data often takes days, weeks, or even months to scrutinize for mechanistic insights. To effectively extract meaningful signals that represent vital degradation intermediates in the early NP degradation mechanism, a semi-automated postprocessing workflow for data filtering, tailored to the aging experiment of NP, has been developed. The automated portion of this workflow is written in a Python code (using pandas, numpy, and matplotlib libraries), which removes more than 65% of potential false signals within seconds via four threshold-based adjustable filters: signal sensitivity, coefficient of variation, number of measurements, and retention time variability. As for the manual portion, a pattern-based inspection method is employed to reduce another 23% or more false positives, which greatly simplifies data visualization and results in less than 3% of potential candidate m/z needing in-depth data interpretation. As a positive control, known compounds are verified. Using this semi-automated data reduction method, the amount of time required is reduced to a matter of hours for data filtering in the non-targeted datasets of aged NP, which saves more time and effort for compound identification.

36 MATERIALS SCIENCE↗

Structure and function of broadly reactive antibody PG16 reveal an H3 subdomain that mediates potent neutralization of HIV-1

Development of an effective vaccine against HIV-1 will likely require elicitation of broad and potent neutralizing antibodies against the trimeric surface envelope glycoprotein (Env). Monoclonal antibodies (mAbs) PG9 and PG16 neutralize {approx}80% of HIV-1 isolates across all clades with extraordinary potency and target novel epitopes preferentially expressed on Env trimers. As these neutralization properties are ideal for a vaccine-elicited antibody response to HIV-1, their structural basis was investigated. The crystal structure of the antigen-binding fragment (Fab) of PG16 at 2.5 {angstrom} resolution revealed its unusually long, 28-residue, complementarity determining region (CDR) H3 forms a unique, stable subdomain that towers above the antibody surface. A 7-residue 'specificity loop' on the 'hammerhead' subdomain was identified that, when transplanted from PG16 to PG9 and vice versa, accounted for differences in the fine specificity and neutralization of these two mAbs. The PG16 electron density maps also revealed that a CDR H3 tyrosine was sulfated, which was confirmed for both PG9 (doubly) and PG16 (singly) by mass spectral analysis. We further showed that tyrosine sulfation plays a role in binding and neutralization. An N-linked glycan modification is observed in the variable light chain, but not required for antigen recognition. Further, the crystal structure of the PG9 light chain at 3.0 {angstrom} facilitated homology modeling to support the presence of these unusual features in PG9. Thus, PG9 and PG16 use unique structural features to mediate potent neutralization of HIV-1 that may be of utility in antibody engineering and for high-affinity recognition of a variety of therapeutic targets.

36 MATERIALS SCIENCE↗

Structural principles of distinct assemblies of the human α4β2 nicotinic receptor

Fast chemical communication in the nervous system is mediated by neurotransmitter-gated ion channels. The prototypical member of this class of cell surface receptors is the cation-selective nicotinic acetylcholine receptor. As with most ligand-gated ion channels, nicotinic receptors assemble as oligomers of subunits, usually as hetero-oligomers and often with variable stoichiometries. This intrinsic heterogeneity in protein composition provides fine tunability in channel properties, which is essential to brain function, but frustrates structural and biophysical characterization. The α4β2 subtype of the nicotinic acetylcholine receptor is the most abundant isoform in the human brain and is the principal target in nicotine addiction. This pentameric ligand-gated ion channel assembles in two stoichiometries of α- and β-subunits (2α:3β and 3α:2β). Both assemblies are functional and have distinct biophysical properties, and an imbalance in the ratio of assemblies is linked to both nicotine addiction and congenital epilepsy. Here we leverage cryo-electron microscopy to obtain structures of both receptor assemblies from a single sample. Antibody fragments specific to β2 were used to ‘break’ symmetry during particle alignment and to obtain high-resolution reconstructions of receptors of both stoichiometries in complex with nicotine. Furthermore, the results reveal principles of subunit assembly and the structural basis of the distinctive biophysical and pharmacological properties of the two different stoichiometries of this receptor.

60 APPLIED LIFE SCIENCES↗

NEAR-INFRARED PHOTOMETRIC SURVEY OF HERBIG Ae/Be CANDIDATE STARS

We report near-infrared photometric measurements of 35 Herbig Ae/Be candidate stars obtained with direct imaging and aperture photometry. Observations were made through the broadband J, H, and K' filters, with each source imaged in at least one of the wavebands. We achieved subarcsecond angular resolution for all observations, providing us with the opportunity to search for close binary candidates and extended structure. The imaging revealed five newly identified binary candidates and one previously resolved T Tauri binary among the target sources with separations of {approx}<2.''5. Separate photometry is provided for each of the binary candidate stars. We detect one extended source that has been identified as a protoplanetary nebula. Comparing our magnitudes to past measurements yields significant differences for some sources, possibly indicating photometric variability. H-band finding charts for all of our sources are provided to aid follow-up high-resolution imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Dissociative recombination by frame transformation to Siegert pseudostates: A comparison with a numerically solvable model

Here, we present a simple two-dimensional model of the indirect dissociative recombination process. The model has one electronic and one nuclear degree of freedom and it can be solved to high precision, without making any physically motivated approximations, by employing the exterior complex scaling method together with the finite-elements method and discrete variable representation. The approach is applied to solve a model for dissociative recombination of H 2 + in the singlet ungerade channels, and the results serve as a benchmark to test validity of several physical approximations commonly used in the computational modeling of dissociative recombination for real molecular targets. The second, approximate, set of calculations employs a combination of multichannel quantum defect theory and frame transformation into a basis of Siegert pseudostates. The cross sections computed with the two methods are compared in detail for collision energies from 0 to 2 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

Cost of Wind Energy Review: 2024 Edition [Slides]

The primary elements of this analysis include: Estimated LCOE for (1) a representative land-based wind energy project installed in a moderate wind resource in the United States, (2) a representative fixed-bottom offshore wind energy project installed in the U.S. North Atlantic, and (3) a representative floating offshore wind energy project installed off the U.S. Pacific Coast. It also updates the LCOE estimates for representative residential-, commercial-, and large-scale distributed wind projects installed in a moderate wind resource in the United States. A sensitivity analyses is included that shows the range of effects that basic LCOE variables could have on the cost of wind energy for land-based and offshore wind projects and provides updated Fiscal Year 2024 values for land-based and offshore wind energy used for Government Performance and Results Act (GPRA) reporting and illustrated progress toward established GPRA targets.

17 WIND ENERGY↗

Collinear Structure Functions of the Nucleon: Status and Future

While our ultimate goal is a complete three-dimensional picture of the nucleon in terms of its fundamental constituents, there are still important lessons to be learned about its “one?dimensional” collinear parton distribution functions (PDFs) like f1(x) and g1(x). There are rigorous proofs for factorization and universality (process independence) which make these PDFs fundamental. They also appear as limits of Generalized Parton Distributions (GPD) and as integrals of transverse momentum-dependent (TMD) parton distribution functions. Experimentally, the unpolarized structure functions F1(x,Q 2 ),F2(x,Q 2 ) have been studied over a huge kinematic range in both variables. Information on the polarized structure functions g1(x,Q 2 ),g2(x,Q 2 ) is somewhat more limited, both in kinematics and in statistical precision. In both cases, much less is known about the neutron than the proton, due to the absence of a free neutron target. Accessing these structure functions at large x (where valence quarks dominate) has been challenging due to the high luminosity and the high resolution required. Finally, much information can be extracted from studying higher twist contributions to these structure functions and the connection between the DIS limit and the region where nucleon resonance excitation dominates. I present an overview of recent experimental results (with special emphasis on the valence region and the transition from quark to hadronic degrees of freedom). I will also give an outlook on the next round of experiments coming online with the energy-upgraded Jefferson Lab electron beam, and future projects like the Electron Ion Collider.

Kuhn, Sebastian E.↗

Arctic Mixed-Phase Cloud Base Ice Precipitation Properties Over the NSA Site

Cloud-climate feedbacks are still the greatest source of uncertainty in current climate projections. Arctic clouds, which are predominantly stratiform and supercooled, often long-lived, and nearly continuously precipitate ice particles, contribute roughly 10% of the uncertainty attributed to the global cloud feedback. This arctic cloud uncertainty is driven by incomplete observational and theoretical knowledge required to estimate and explain the state and active processes occurring in those clouds. A focus on ice precipitation properties at arctic cloud base rather than the surface deconfounds the product of cloud condensate sink processes from the influence of the atmospheric thermodynamic state below cloud base, rendering cloud-base properties a more appealing target for inference and evaluation of model simulations. This data set provides more than 1800 samples of cloud-base ice precipitation properties over Utqiagvik, North Slope of Alaska, all of which were retrieved using the synthesis of ARM radar and lidar measurements. The retrieved ice precipitation variables in this data set include, among others, the ice number concentration, water content, PSD parameters, precipitation rate, mass-weighted fall velocity, vertical air motion, and effective radius, all of which are highly valuable for model evaluation and a general understanding of polar cloud sink processes. Each variable sample includes its mean value and associated uncertainty. Additional variables based on ARM measurements (liquid layer statistics, etc.) are included in this data set. The retrieval algorithm and analysis of this data set are described in Silber (JGR, 2023, https://doi.org/10.1029/2022JD038202).

54 ENVIRONMENTAL SCIENCES↗

Bundle Data Approach at GES DISC Targeting Natural Hazards

Severe natural phenomena such as hurricane, volcano, blizzard, flood and drought have the potential to cause immeasurable property damages, great socioeconomic impact, and tragic loss of human life. From searching to assessing the Big, i.e., massive and heterogeneous scientific data (particularly, satellite and model products) in order to investigate those natural hazards, it has, however, become a daunting task for Earth scientists and applications researchers, especially during recent decades. The NASA Goddard Earth Sciences Data and Information Service Center (GES DISC) has served Big Earth science data, and the pertinent valuable information and services to the aforementioned users of diverse communities for years. In order to help and guide our users to online readily (i.e., with a minimum effort) acquire their requested data from our enormous resource at GES DISC for studying their targeted hazard event, we have thus initiated a Bundle Data approach in 2014, first targeting the hurricane event topic. We have recently worked on new topics such as volcano and blizzard. The bundle data of a specific hazard event is basically a sophisticated integrated data package consisting of a series of proper datasets containing a group of relevant (knowledge--based) data variables readily accessible to users via a system-prearranged table linking those data variables to the proper datasets (URLs). This online approach has been developed by utilizing a few existing data services such as Mirador as search engine; Giovanni for visualization; and OPeNDAP for data access, etc. The online Data Cookbook site at GES DISC is the current host for the bundle data. We are now also planning on developing an Automated Virtual Collection Framework that shall eventually accommodate the bundle data, as well as further improve our management in Big Data.

GES DISC↗

Spectral Characterization of Modern Spacecraft Materials

One of the observational parameters of interest in ground-based optical measurements is ascertaining material properties using broadband filter photometry and spectroscopy for orbiting targets. Broadband photometry can provide reflectance measurements that can aid in color-color indices and assess if objects can be classified into families or taxonomies. However, these reflectance properties can vary due to aspect angle, phase angle, and general degradation of the target’s exterior material. Spectral characterization can aid in material characterization utilizing known absorption bands and spectra signatures, but these signatures are affected by the same conditions described for remote observations. When utilizing ground-based measurements, it is well understood that material characterization is subject to variability due to space weathering and/or other external events (i.e., collision or explosion). The focus of this study is on space weathering effects on spacecraft materials in low Earth orbit. To better assess how materials are affected by the harsh space environment, specifically modern materials, a collection of materials was analyzed in both its pristine condition and after electron bombardment. This sample collection is part of an upcoming mission with the Materials International Space Station Experiment Flight Facility (MISSE-FF) that will be launched in 2022. These laboratory analyses on the samples will provide a ground truth to compare with the in-situ collected data. The data will also be stored in the NASA Johnson Space Center’s Spacecraft Materials Spectral Database that is available to U. S. citizens and maintained by the Orbital Debris Program Office. The following paper provides an overview of the materials investigated, laboratory and database overview, and spectral results for both pristine and post-electron exposed conditions. The spectral signature data highlights which materials are stable, or remain relatively unchanged, and which materials vary significantly due to exposure and material configuration (variations due to rotation of the sample on a flat surface). Initial results on changes in spectral directional reflectance of the materials as a function of incident illumination direction are also presented. This data also will benefit the space situational awareness community with spectral characterization of novel materials that can support their respective optical measurements focused on material identification.

Heather M Cowardin↗

Electrified vehicle DC power conversion with distributed control

An electrified vehicle has a battery pack comprising series-connected battery units providing a main voltage. To supply a lower voltage bus equally from all battery units, a plurality of DC/DC converters are powered by respective units and have their outputs in parallel. A central module has an outer loop controller generating a target current to regulate the bus voltage to a predetermined voltage and has an allocator distributing the target current into a plurality of allocated current commands according to respective states of charge of the battery units. A plurality of local controllers each adjusts a current of a respective DC/DC converter. Each local controller receives a respective allocated current command as a respective feedforward control variable. Each local controller uses an error between the bus voltage and the predetermined voltage to be integrated as a respective feedback control variable only when the error is above a threshold.

33 ADVANCED PROPULSION SYSTEMS↗