Search NASA⌕ Search

SEARCH · Search NASA

Results for “throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Mechanical separations of corn stover anatomical fractions in an integrated feedstock preprocessing system: An experimental and data-driven modeling study

High variabilities of material attributes in lignocellulosic biomass present risks for biofuel and biochemical productions and must be mitigated via preprocessing. Since almost no mechanical device is originally designed for processing biomass, how to operate existing apparatuses with efficient performance has not been investigated extensively. This work presents a study on an integrated screening and air classification to separate cobs and stalks from husks and leaves in corn stover. Prototype machine learning models were developed to assess the feasibility of predicting the process outcome based on the measurable parameters. The models trained upon limited experimental data rendered decent predictive accuracy of yield and purity. The experimental data and modeling results collectively suggest decreasing throughput leads to a higher purity. To the contrary, if throughput increases, a lower purity is likely. A possible trade-off between yield and purity of the separated streams indicates the need for optimal combinations of feedstock size, moisture, and throughput to achieve optimized separations. The results of this study also suggest the need to further improve model predictability by developing more accurate formulations for physics governing the integrated unit operations. To accomplish this, additional experimental data needs to be generated for model training.

09 - BIOMASS FUELS↗

An antibody-free platform for multiplexed, sensitive quantification of protein biomarkers in complex biomatrices

Sensitive, multiplexed protein quantification remains challenging despite recent advancements in LC-MS assays for targeted protein biomarker quantification. High-sensitivity protein biomarker measurements usually require immuno-affinity enrichment of target protein; a process which is highly dependent on capture reagent and limited in capability to measure multiple analytes. Herein, we report a novel antibody-free platform, which measures multiple biomarkers from complex matrices employing a strategically optimized solid-phase extraction cleanup and orthogonal multidimensional LC-MS. Eight human protein biomarkers with different specifications were spiked into canine plasma as a model investigation system. The developed strategy achieved the desired sensitivity, robustness, and throughput via the following steps: (1) post digestion mixed-mode cation exchange-reverse phase SPE enrichment cleaned up the sample initially; (2) rapid, high-pH peptide fractionation further eliminated background components efficiently while selectively enriched signature peptides (SP) to provide sufficient sensitivity for multiple targets; and (3) trapping-micro-LC-MS analysis delivered high sensitivity comparable to a nano-LC-MS method but with much better robustness and throughput for the final analysis. Compared with a conventional LC-MS assay with direct protein digestion and limited clean-up, analysis with this antibody-free platform improved the LLOQ by 1–2 orders of magnitude for the eight protein biomarkers, reaching as low as 5 ng/mL in plasma, with feasible robustness and throughput. In conclusion, this platform was applied for the quantification of biomarkers of respiratory conditions in patients with various lung diseases, demonstrating real-world applicability.

59 BASIC BIOLOGICAL SCIENCES↗

Rahasak—Scalable blockchain architecture for enterprise applications

Blockchain-based decentralized infrastructure has been adapted in various industries to handle the sensitive data in a privacy-preserving manner without trusting third parties. However, integrating state-of-the-art blockchain platforms with the scalable, enterprise-level applications result in several challenges. Current blockchain platforms do not support high transaction throughput, lack high scalability, and cannot provide real-time transaction processing and back-pressure operation handling in high transaction throughput applications(e.g Big data, IoT). In this paper, we propose a novel permissioned blockchain platform “Rahasak” for highly scalable, enterprise applications. Rahasak blockchain adopts the Apache Kafka-based consensus on top of a “Validate-Execute-Group” blockchain architecture to handle realtime transaction execution on the blockchain. The architecture is equipped with a functional programming and actor-based smart contract platform that enables concurrent execution of transactions in the blockchain. Rahasak supports high transaction throughput, high scalability, concurrent transaction execution, data analytics features. Finally, with Rahasak, we make blockchain more scalable, secure, structured and meaningful for further data analytics.

97 MATHEMATICS AND COMPUTING↗

Characterization of Strategies for Obtaining Confident Identifications in Bottom-Up Proteomics Measurements Using Hybrid FTMS instruments

Hybrid FTMS instruments, such as the LTQ-FTTM and LTQ-OrbitrapTM, are capable of generating fast duty cycle linear ion trap MS/MS data along with high resolution information without compromising the overall throughput of measurements. Combined with online LC separations, these instruments represent powerful and flexible tools for proteomics research. In the present work, we explore strategies for high throughput, high coverage proteomics measurements using hybrid FTMS instruments. Our accurate mass and time tag (AMT tag) strategy enables identification of thousands of peptides in a single LC-FTMS analysis by comparing accurate molecular mass and LC elution time information from the analysis to a reference database. An alternative strategy considered here employs linear ion trap (low resolution) MS/MS identifications generated by an appropriate search engine, such as SEQUEST; the high resolution precursor ion spectra were used to refine the MS/MS identifications, an approach termed Accurate Precursor Mass Filter (APMF). The APMF results can be additionally filtered using the LC elution time information from the AMT tag database, which constitutes a Precursor Mass and Time Filter (PMTF), the third approach implemented in this study. Both the APMF and the PMTF approaches are evaluated for coverage and confidence of peptide identifications and contrasted with the current AMT tag strategy. Two separate methodologies were used to reliably quantify identification confidence: a commonly used decoy database method and an alternative method based on the mass accuracy histogram. The two methodologies produced consistent results, confirming the validity of the identification confidence evaluations. Comparison of the three approaches has shown that the AMT tag data analysis approach may be preferential for studies giving a priority to the highest achievable coverage. The APMF approach by itself does not require AMT tag database and provides a moderate coverage combined with acceptable confidence values of ~99%.The PMTF approach yielded a significantly better peptide identification confidence, >99.9%, that essentially excluded any false peptide identifications. The results suggest that even with a perfect peptide ID (0% FDR in the peptide MS/MS database), the peak matching FDR is a function of the database size, so smaller high confidence databases are the goal. Thus a combined strategy can implement multi-pass APMF approach to generate high confidence AMT tag databases, which can be then validated using PMTF approach; the compact high quality databases will be used for subsequent high-throughput, high coverage AMT tag studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Rapid assessment of human amylin aggregation and its inhibition by copper(II) ions by laser ablation electrospray ionization mass spectrometry with ion mobility separation

Native electrospray ionization (ESI) mass spectrometry (MS) is often used to monitor noncovalent complex formation between peptides and ligands. The relatively low throughput of this technique, however, is not compatible with extensive screening. Laser ablation electrospray ionization (LAESI) MS combined with ion mobility separation (IMS) can analyze complex formation and provide conformation information within a matter of seconds. Islet amyloid polypeptide (IAPP) or amylin, a 37-amino acid residue peptide, is produced in pancreatic beta-cells through proteolytic cleavage of its prohormone. Both amylin and its precursor can aggregate and produce toxic oligomers and fibrils leading to cell death in the pancreas that can eventually contribute to the development of type 2 diabetes mellitus. The inhibitory effect of the copper(II) ion on amylin aggregation has been recently discovered, but details of the interaction remain unknown. Finding other more physiologically tolerated approaches requires large scale screening of potential inhibitors. In this paper, we demonstrate that LAESI-IMS-MS can reveal the binding stoichiometry, copper oxidation state, and the dissociation constant of human amylin–copper(II) complex. The conformations of hIAPP in the presence of copper(II) ions were also analyzed by IMS, and preferential association between the β-hairpin amylin monomer and the metal ion was found. The copper(II) ion exhibited strong association with the —HSSNN– residues of the amylin. In the absence of copper(II), amylin dimers were detected with collision cross sections consistent with monomers of β-hairpin conformation. When copper(II) was present in the solution, no dimers were detected. Thus, the copper(II) ions disrupt the association pathway to the formation of β-sheet rich amylin fibrils. Using LAESI-IMS-MS for the assessment of amylin–copper(II) interactions demonstrates the utility of this technique for the high-throughput screening of potential inhibitors of amylin oligomerization and fibril formation. Finally and more generally, this rapid technique opens the door for high-throughput screening of potential inhibitors of amyloid protein aggregation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separating Miscible Liquid–Liquid Mixtures Using Supported Ionic Liquid Membranes

Supported liquid membranes (SLMs) are promising in separating miscible liquid–liquid mixtures, which has been a key challenge in wastewater treatment and other applications. However, SLMs suffer from poor durability due to the loss of the liquid phase. In current work, ionic liquids (ILs) with high stability have been impregnated into polyvinylidene fluoride membranes to separate miscible benzene–heptane mixtures. The two imidazolium-based ILs, that is, 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF 6 ]) and 1-butyl-3-methylimidazolium tris(pentafluoroethyl) trifluorophosphate ([BMIM][FAP]), were tested in supported ionic liquid membranes (SILMs) for the benzene–heptane separation. Both ILs show successful separation within 48 h as indicated by nuclear magnetic resonance results. Compared to the SILM with [BMIM][FAP], the SILM with [BMIM][PF 6 ] has lower throughput and higher selectivity. The higher selectivity can be attributed to the higher hydrophilicity of [BMIM][PF 6 ], which results in strong repulsion against heptane. The lower throughput can be attributed to the higher hydrophilicity as well since it lowers the solubility of benzene in [BMIM][PF 6 ]. The stability of IL in SILMs has also been investigated via multiple separation cycles. The scanning electron microscopy, weight change of SILMs, and separation results indicate that the separation efficiency of the [BMIM][PF 6 ] SILM does not degrade for up to 144 h. The SILM has been further optimized with curvature design (i.e., curved SILM) to increase the interfacial area and thus increase the separation throughput, where the curved SILM separation device was 3D-printed. Here, the findings here have important implications on design and application of SILMs in separating miscible liquid–liquid mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning Framework for Characterizing Processing–Structure Relationship in Block Copolymer Thin Films

The morphology of block copolymers (BCPs) critically influences material properties and applications. This work introduces a machine learning (ML)-enabled, high-throughput framework for analyzing grazing incidence small-angle X-ray scattering (GISAXS) data and atomic force microscopy (AFM) images to characterize BCP thin film morphology. A convolutional neural network was trained to classify AFM images by surface features, achieving 97% testing accuracy. Classified images were then analyzed to extract 2D grain size measurements from the samples in a high-throughput manner. ML models were trained to predict domain orientation based on processing parameters such as solvent ratio, additive type, and additive ratio. GISAXS-based properties were predicted with strong performances (R 2 > 0.75), while AFM-based property predictions were less accurate (R 2 < 0.60), likely due to the localized nature of AFM measurements compared to the bulk information captured by GISAXS. Beyond model performance, interpretability was addressed using SHapley Additive exPlanations (SHAP). SHAP analysis revealed that the additive ratio had the largest impact on morphological predictions, where additive provides the BCP chains with increased volume to rearrange into thermodynamically favorable morphologies. This interpretability helps validate model predictions and offers insight into parameter importance. Altogether, the presented framework combining high-throughput characterization and interpretable ML offers an approach to exploring and optimizing BCP thin film morphology across a broad processing landscape.

36 MATERIALS SCIENCE↗

Crystal Orientation and Defect Mapping in Electron-Beam-Sensitive Zeolites with Near-Axis Transmission Kikuchi Diffraction

Porous materials are vital in catalysis, energy conversion, and environmental remediation. Understanding structural heterogeneity in zeolites is key to linking synthesis, framework intergrowths, and catalytic performance, yet current methods for phase identification and spatial mapping lack sufficient resolution or throughput. We present a high-throughput approach using near-axis transmission Kikuchi diffraction in a scanning electron microscope, achieving high phase and spatial resolution for electron-beam-sensitive zeolites, including ZSM-5 and, for the first time, Zeolite A. Here, this method enables direct visualization of intergrowth features that critically affect catalytic and adsorption behavior, bridging the gap between ensemble-averaged X-ray diffraction and high-resolution but low-throughput transmission electron microscopy. Combining nanoscale mapping with statistical sampling is highly suited for machine-learning pipelines guiding new structure function understanding and could be extended to other beam-sensitive porous materials such as metal–organic or covalent–organic frameworks.

crystallography↗

Process Model-Based Validation of the Intensification of Biomass Fast Pyrolysis in a Fluidized Bed via Autothermal Operation

A model for the fluidized-bed pyrolysis of biomass is extended to enable the simulation of intensified autothermal operation. In this system, partial oxidation of char and pyrolysate species replaces an external heat source to supply the enthalpy of pyrolysis, greatly increasing the throughput of a given fast pyrolysis reactor. Oxidation reactions are compiled from CRECK and other literature sources and extended to cover the species found in pyrolysis products, including a derivation of the catalytic effect of ash on char combustion from experimental studies at Iowa State University (ISU). Results indicate a roughly 3-fold increase in biomass throughput for a given reactor volume at the pilot scale with minimal loss of valuable products, in agreement with published data from the 3 × 10 -2 m 3 reactor operated by ISU. Additionally, a proposal for a 250 ton/day commercial-scale biomass pyrolysis reactor is analyzed, showing that the same size reactor operated by heating the fluidizing gas externally would have only one-tenth the capacity; if operated by heating the sand externally, the sand would need to circulate at an impractical 0.7 bed volume per minute rate to maintain a 250 ton/day biomass throughput.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting defect behavior in B2 intermetallics by merging ab initio modeling and machine learning

We present a combination of machine learning and high throughput calculations to predict the points defects behavior in binary intermetallic (A-B) compounds, using as an example systems with the cubic B2 crystal structure (with equiatomic AB stoichiometry). To the best of our knowledge, this work is the first application of machine learning-models for point defect properties. High throughput first principles density functional calculations have been employed to compute intrinsic point defect energies in 100 B2 intermetallic compounds. The systems are classified into two groups: (i) those for which the intrinsic defects are antisites for both A and B rich compositions, and (ii) those for which vacancies are the dominant defect for either or both composition ranges. The data was analyzed by machine learning-techniques using decision tree, and full and reduced multiple additive regression tree (MART) models. Among these three schemes, a reduced MART (r-MART) model using six descriptors (formation energy, minimum and difference of electron densities at the Wigner-Seitz cell boundary, atomic radius difference, maximal atomic number and maximal electronegativity) presents the highest fit (98 %) and predictive (75 %) accuracy. This model is used to predict the defect behavior of other B2 compounds, and it is found that 45 % of the compounds considered feature vacancies as dominant defects for either A or B rich compositions (or both). The ability to predict dominant defect types is important for the modeling of thermodynamic and kinetic properties of intermetallic compounds, and the present results illustrate how this information can be derived using modern tools combining high throughput calculations and data analytics.

97 MATHEMATICS AND COMPUTING↗

Empirical modeling of dopability in diamond-like semiconductors

Carrier concentration optimization has been an enduring challenge when developing newly discovered semiconductors for applications (e.g., thermoelectrics, transparent conductors, photovoltaics). This barrier has been particularly pernicious in the realm of high-throughput property prediction, where the carrier concentration is often assumed to be a free parameter and the limits are not predicted due to the high computational cost. In this work, we explore the application of machine learning for high-throughput carrier concentration range prediction. Bounding the model within diamond-like semiconductors, the learning set was developed from experimental carrier concentration data on 127 compounds ranging from unary to quaternary. The data were analyzed using various statistical and machine learning methods. Accurate predictions of carrier concentration ranges in diamond-like semiconductors are made within approximately one order of magnitude on average across both p- and n-type dopability. The model fit to empirical data is analyzed to understand what drives trends in carrier concentration and compared with previous computational efforts. Lastly, dopability predictions from this model are combined with high-throughput quality factor predictions to identify promising thermoelectric materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D nanolithography with metalens arrays and spatially adaptive illumination

The growing demand for advanced materials, miniaturized devices and integrated microsystems calls for the reliable fabrication of complex, multiscale, three-dimensional (3D) architectures, a need increasingly addressed through light-based and laser-based processes. However, owing to the field-of-view (FOV) limitations of conventional imaging optics, existing 3D laser nanofabrication techniques face fundamental challenges in throughput, proximity error and stitching defects on the path to scaling. Here, in this study, we present a scalable 3D nanofabrication platform that uses a metalens-generated focal spot array to parallelize two-photon lithography (TPL) beyond centimetre-scale write field areas. Metalenses are ideally suited for producing submicron-scale focal spots for high-throughput nanolithography, as they uniquely feature large numerical apertures (NAs), immersion media compatibility and large-scale manufacturability. We experimentally demonstrate a printing system that uses a 12-cm 2 metalens array to produce more than 120,000 cooperative focal spots, corresponding to a throughput exceeding 10 8 voxels s −1 . By programmatically patterning the focal spot array using a spatial light modulator (SLM), an adaptive parallel printing strategy is developed for precise greyscale linewidth modulation and choreographed printing of semiperiodic and fully aperiodic 3D geometries. We demonstrate parallel printing of replicated microstructures (>50 M microparticles per day), centimetre-scale 3D architectures with feature sizes down to 113 nm, and photonic and mechanical metamaterials. This work demonstrates the potential of 3D nanolithography towards wafer-scale production, showing how TPL could be used at scale for applications in microelectronics, biomedicine, quantum technology and high-energy laser targets.

Materials science↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Spatially-Resolved Proteomics: Rapid Quantitative Analysis of Laser Capture Microdissected Alveolar Tissue Samples

Global proteomics approaches allow characterization of whole tissue lysates to an impressive depth. However, it is now increasingly recognized that to better understand the complexity of multicellular organisms, global protein profiling of specific spatially defined regions/substructures of tissues (i.e. spatially-resolved proteomics) is essential. Laser capture microdissection (LCM) enables microscopic isolation of defined regions of tissues preserving crucial spatial information. However, current proteomics workflows entail several manual sample preparation steps and are challenged by the microscopic mass-limited samples generated by LCM, and that impact measurement robustness, quantification, and throughput. Here, we coupled LCM with a fully automated sample preparation workflow that with a single manual step allows: protein extraction, tryptic digestion, peptide cleanup and LC-MS/MS analysis of proteomes from microdissected tissues. Benchmarking against the current state of the art in ultrasensitive global proteomic analysis, our approach demonstrated significant improvements in quantification and throughput. Using our LCM-SNaPP proteomics approach, we characterized to a depth of more than 3,400 proteins, the ontogeny of protein changes during normal lung development in laser capture microdissected alveolar tissue containing ~4,000 cells per sample. Importantly, the data revealed quantitative changes for 350 low abundance transcription factors and signaling molecules, confirming earlier transcript-level observations and defining seven modules of coordinated transcription factor/signaling molecule expression patterns, suggesting that a complex network of temporal regulatory control directs normal lung development with epigenetic regulation fine-tuning pre-natal developmental processes. Furthermore, our LCM-proteomics approach facilitates efficient, spatially-resolved, ultrasensitive global proteomics analyses in high-throughput that will be enabling for several clinical and biological applications.

60 APPLIED LIFE SCIENCES↗

Machine learning-assisted ultrafast flash sintering of high-performance and flexible silver–selenide thermoelectric devices

Flexible thermoelectric generators (TEGs) have shown immense potential for serving as a power source for wearable electronics and the Internet of Things. A key challenge preventing large-scale application of TEGs lies in the lack of a high-throughput processing method, which can sinter thermoelectric (TE) materials rapidly while maintaining their high thermoelectric properties. Herein, we integrate high-throughput experimentation and Bayesian optimization (BO) to accelerate the discovery of the optimum sintering conditions of silver–selenide TE films using an ultrafast intense pulsed light (flash) sintering technique. Due to the nature of the high-dimensional optimization problem of flash sintering processes, a Gaussian process regression (GPR) machine learning model is established to rapidly recommend the optimum flash sintering variables based on Bayesian expected improvement. For the first time, an ultrahigh-power factor flexible TE film (a power factor of 2205 μW m -1 K -2 with a zT of 1.1 at 300 K) is demonstrated with a sintering time less than 1.0 second, which is several orders of magnitude shorter than that of conventional thermal sintering techniques. Further, the films also show excellent flexibility with 92% retention of the power factor (PF) after 10 3 bending cycles with a 5 mm bending radius. In addition, a wearable thermoelectric generator based on the flash-sintered films generates a very competitive power density of 0.5 mW cm -2 at a temperature difference of 10 K. This work not only shows the tremendous potential of high-performance and flexible silver–selenide TEGs but also demonstrates a machine learning-assisted flash sintering strategy that could be used for ultrafast, high-throughput and scalable processing of functional materials for a broad range of energy and electronic applications.

25 ENERGY STORAGE↗

Demonstration of and future perspective on scaling ultrafast-laser-ablation microstructuring of Li-ion battery electrodes to roll-to-roll production and large-format cells

This work demonstrates integration of an ultrafast laser onto a roll-to-roll machine, the laser structuring of a double-sided, 700 m long roll of graphite battery anode and its subsequent manufacture into 27 Ah prismatic cells. The electrode was ablated with a novel hybrid-microstructure composed of both hexagonally arranged pores for enhanced rate performance and channels for fast electrolyte wetting. Subsequently, this anode and a non-ablated baseline anode are paired with an NMC111 cathode for cell building and electrochemical characterization. Compared to the baseline, laser ablated cells demonstrated a reduction in soaking time of at least 60%, an improvement in fast charge capability with >30% more capacity accepted during 6C charging, and an extension of cycle life of >40% during 0.5C cycling. Further, a perspective is provided on scaling ultrafast laser ablation of battery electrodes to industrial throughputs. Additionally, lessons learned from this pilot-scale demonstration are provided in regards to optical architecture, debris removal, and system control. A techno-economic analysis is used to demonstrate that laser ablation can be integrated into existing electrode manufacturing facilities with only ≈$\$$1.3 per kWh increase (≈2%) in manufacturing cost. Preemptive electrode design for laser ablation is discussed as a further method for enhancing performance. Finally, an analysis of available laser systems and beam-scanning architectures is used to determine design requirements to scale process throughput to a state-of-the-art speed of 50 m min −1 . This analysis demonstrates that laser ablating Li-ion battery electrodes has multiple benefits to manufacturing and battery performance, that the technology already exists to achieve high laser-ablation throughputs, and that integrating ultrafast laser ablation to electrode manufacturing will not create a cost or processing bottleneck.

25 ENERGY STORAGE↗

Key Technologies for Ultra High Dose CMOS Applications

The trend towards shrinking advanced microelectronic Logic and DRAM devices will require ultra high dose implantation. One ultra high dose application in DRAM, being rapidly adopted in production is Dual Poly Gate (DPG). Three main challenges existed for the adoption of this high dose dual poly gate (DPG) doping applications: monitoring of high dose implantation, photoresist stripping and maintaining high throughput. In this paper we present how these challenges have been addressed. VSEA's plasma doping (PLAD) tool offers several unique advantages for DPG applications. When compared to conventional or molecular beam line implanters or other immersion techniques, PLAD delivers 3 to 7 times higher throughput (compared to traditional ion implanter) without dopant penetration through the thin doped polysilicon layer into the gate oxide. It also improves P{sup +} poly silicon DPG device properties at superior throughput. In this work we demonstrate how hot spray photoresist strip processing eliminates the need for multiple-tools required for wet+ash+wet process. In addition to PLAD's patented in-situ dose control metrology we also demonstrate an ex-situ high dose implantation metrology using spectroscopic ellipsometer (SE) and spectroscopic reflectometer (SR). The technique shows good correlation (R{sup 2}{approx}0.99) between implant dose and damaged layer thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗