Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arms Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Is Corn Stover Harvest Predictable Using Farm Operation, Technology, and Management Variables?

Core Ideas Corn stover removal was not common in 2010. Crop sequences were similar for stover and non‐stover harvest farms. State‐level variation occurred in the relative size of farms removing corn stover. Soil erosion control measures were not frequently adopted by either farm group. Crop residue management, provision of animal feed or bedding, and increased income are potential reasons for harvesting corn ( Zea mays L.) stover. Reasons for not doing so include the need for crop residue to restore or increase soil organic matter, protect against wind and water erosion, and cycle plant nutrients. Bioenergy market development may increase the number of producers harvesting corn stover. Can farming practice data predict the likelihood for harvesting corn stover at a national scale? Farm operation, technology, and management variables from the 2010 Agricultural Resource Management Survey (ARMS) of U.S. corn growers were compared between operations that removed corn stover and those that did not. Nationwide, stover was removed from approximately 6.3% of all corn operations, indicating stover harvest was not a common practice in 2010. Factors increasing the likelihood for stover harvest included producing feed corn, managing crop residues for pest control, and farmland ownership. Technology and conservation practice adoption rates were similar in both groups. Excessive stover removal can increase soil degradation. Both groups had erosion control adoption rates of ≤10%, which may provide an additional disincentive to harvest stover. Overall, the evaluated variables were similar between producers that did and did not harvest stover. This assessment provides a 2010 national baseline that can be used for future evaluations as bioenergy and bioproduct markets develop.

54 ENVIRONMENTAL SCIENCES↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

Control of intelligent robots in space

In view of space activities like International Space Station, Man-Tended-Free-Flyer (MTFF) and free flying platforms, the development of intelligent robotic systems is gaining increasing importance. The range of applications that have to be performed by robotic systems in space includes e.g., the execution of experiments in space laboratories, the service and maintenance of satellites and flying platforms, the support of automatic production processes or the assembly of large network structures. Some of these tasks will require the development of bi-armed or of multiple robotic systems including functional redundancy. For the development of robotic systems which are able to perform this variety of tasks a hierarchically structured modular concept of automation is required. This concept is characterized by high flexibility as well as by automatic specialization to the particular sequence of tasks that have to be performed. On the other hand it has to be designed such that the human operator can influence or guide the system on different levels of control supervision, and decision. This leads to requirements for the hardware and software concept which permit a range of application of the robotic systems from telemanipulation to autonomous operation. The realization of this goal requires strong efforts in the development of new methods, software and hardware concepts, and the integration into an automation concept.

Freund, E.↗

Continued Benefit to Rectal Separation for Prostate Radiation Therapy: Final Results of a Phase III Trial

Purpose: SpaceOAR, a Food and Drug Administration–approved hydrogel intended to create a rectal–prostate space, was evaluated in a single-blind phase III trial of image guided intensity modulated radiation therapy. A total of 222 men were randomized 2:1 to the spacer or control group and received 79.2 Gy in 1.8-Gy fractions to the prostate with or without the seminal vesicles. The present study reports the final results with a median follow-up period of 3 years. Methods and Materials: Cumulative (Common Terminology Criteria for Adverse Events, version 4.0) toxicity was evaluated using the log-rank test. Quality of life (QOL) was examined using the Expanded Prostate Cancer Index Composite (EPIC), and the mean changes from baseline in the EPIC domains were tested using repeated measures models. The proportions of men with minimally important differences (MIDs) in each domain were tested using repeated measures logistic models with prespecified thresholds. Results: The 3-year incidence of grade ≥1 (9.2% vs 2.0%; P=.028) and grade ≥2 (5.7% vs 0%; P=.012) rectal toxicity favored the spacer arm. Grade ≥1 urinary incontinence was also lower in the spacer arm (15% vs 4%; P=.046), with no difference in grade ≥2 urinary toxicity (7% vs 7%; P=0.7). From 6 months onward, bowel QOL consistently favored the spacer group (P=.002), with the difference at 3 years (5.8 points; P<.05) meeting the threshold for a MID. The control group had a 3.9-point greater decline in urinary QOL compared with the spacer group at 3 years (P<.05), but the difference did not meet the MID threshold. At 3 years, more men in the control group than in the spacer group had experienced a MID decline in bowel QOL (41% vs 14%; P=.002) and urinary QOL (30% vs 17%; P=.04). Furthermore, the control group were also more likely to have experienced large declines (twice the MID) in bowel QOL (21% vs 5%; P=.02) and urinary QOL (23% vs 8%; P=.02). Conclusions: The benefit of a hydrogel spacer in reducing the rectal dose, toxicity, and QOL declines after image guided intensity modulated radiation therapy for prostate cancer was maintained or increased with a longer follow-up period, providing stronger evidence for the benefit of hydrogel spacer use in prostate radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). Conclusions: Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Manipulation strategies for massive space payloads

Control for the bracing strategy is being examined. It was concluded earlier that trajectory planning must be improved to best achieve the bracing motion. Very interesting results were achieved which enable the inverse dynamics of flexible arms to be calculated for linearized motion in a more efficient manner than previously published. The desired motion of the end point beginning at t=0 and ending at t=t sub f is used to calculate the required torque at the joint. The solution is separated into a causal function that is zero for t is less than 0 and an accusal function which is zero for t is greater than t sub f. A number of alternative end point trajectories were explored in terms of the peak torque required, the amount of anticipatory action, and other issues. The single link case is the immediate subject and an experimental verification of that case is being performed. Modeling with experimental verification of closed chain dynamics continues. Modeling effort has pointed out inaccuracies that result from the choice of numerical techniques used to incorporate the closed chain constraints when modeling our experimental prototype RALF (Robotic Arm Large and Flexible). Results were compared to TREETOPS, a multi body code. The experimental verification work is suggesting new ways to make comparisons with systems having structural linearity and joint and geometric nonlinearity. The generation of inertial forces was studied with a small arm that will damp the large arm's vibration.

Book, Wayne J.↗

Three dimensional vision - Requirements and applications in a space environment

Various approaches to three-dimensional vision in space are reviewed with emphasis on the redundant 3D vision system designed for the Center for Intelligent Robotic Systems for Space Exploration. The system uses a controllable subset of five cameras, programmable structured light patterns, and sophisticated calibration routines. The design emphasizes real-time operation, human supervisory intervention, and the use of 3D vision to enhance the performance of cooperating robotic arms. Two methods of estimating the location of a point using 3D vision are discussed.

Noseworthy, J. R.↗

STS-88 Day 04 Highlights

On this forth day of the STS-88 mission, the flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei are awakened to the sounds of "Somewhere Over the Rainbow," requested by Commander Bob Cabana's daughter, Sarah. With the three-story-high Unity connecting module latched upright in the shuttle's payload bay, Cabana takes manual control of the shuttle as it moves to within about a half-mile of Zarya. Cabana and Sturckow execute a sequence of maneuvers that will bring Endeavour directly above the module. Currie uses the robotic arm to capture the module. She then positions Zarya above Unity's docking mechanism.

Source record↗

NASA Tech Briefs, February 2014

Topics include: JWST Integrated Simulation and Test (JIST) Core; Software for Non-Contact Measurement of an Individual's Heart Rate Using a Common Camera; Rapid Infrared Pixel Grating Response Testbed; Temperature Measurement and Stabilization in a Birefringent Whispering Gallery Resonator; JWST IV and V Simulation and Test (JIST) Solid State Recorder (SSR) Simulator; Development of a Precision Thermal Doubler for Deep Space; Improving Friction Stir Welds Using Laser Peening; Methodology of Evaluating Margins of Safety in Critical Brazed Joints; Interactive Inventory Monitoring; Sensor for Spatial Detection of Single-Event Effects in Semiconductor-Based Electronics; Reworked CCGA-624 Interconnect Package Reliability for Extreme Thermal Environments; Current-Controlled Output Driver for Directly Coupled Loads; Bulk Metallic Glasses and Matrix Composites as Spacecraft Shielding; Touch Temperature Coating for Electrical Equipment on Spacecraft; Li-Ion Electrolytes Containing Flame-Retardant Additives; Autonomous Robotic Manipulation (ARM); CARVE Log; Platform Perspective Toolkit; Convex Hull-Based Plume and Anomaly Detection; Pre-Filtration of GOSAT Data Using Only Level 1 Data and an Intelligent Filter to Remove Low Clouds; Affordability Comparison Tool - ACT; "Ascent - Commemorating Shuttle" for iPad; Cassini Mission App; Light-Weight Workflow Engine: A Server for Executing Generic Workflows; Model for System Engineering of the CheMin Instrument; Timeline Central Concepts; Parallel Particle Filter Toolkit; Particle Filter Simulation and Analysis Enabling Non-Traditional Navigation; Quasi-Terminator Orbits for Mapping Small Primitive Bodies; The Subgrid-Scale Scalar Variance Under Supercritical Pressure Conditions; Sliding Gait for ATHLETE Mobility; and Automated Generation of Adaptive Filter Using a Genetic Algorithm and Cyclic Rule Reduction.

Source record↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

spacesuit arms↗

HI-SCALE Nanoparticle Composition and Precursors Field Campaign Report

From 21 August to 27 September, 2016, during the second Intensive Operational Period (IOP) of the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecoystems (HI-SCALE) field campaign, a suite of instruments were placed in the Guest Instrument Facility (GIF) at the Central Facility of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site in Lamont, Oklahoma. The goal of these measurements was to fully characterize the formation and evolution of atmospheric aerosol particles through measurements of gas-phase precursor and ambient nanoparticle composition. Specifically, we sought to: 1. investigate the role of acid-base chemistry in new-particle growth through measurements of ammonia and amines as well as organic and inorganic acids in both atmospheric nanoparticles and the gas phase; 2. investigate the contribution of other surface-area or volume-controlled processes to nanoparticle formation and growth, such as the uptake of extremely low volatility organic compounds (ELVOCs); 3. evaluate the performance of a new instrument being developed with funding from the DOE Small Business Innovation Research (SBIR) program for measuring gas-phase amines and related compounds; and 4. together with colleagues measuring on the ground and onboard the ARM Gulfstream-1 (G-1) aircraft during HI-SCALE, create a comprehensive data set related to new particle formation and growth that can be used in modeling efforts by the research team as well as DOE collaborators.

54 ENVIRONMENTAL SCIENCES↗

Clouds, Aerosols, and Precipitation in the Marine Boundary Layer: An Arm Mobile Facility Deployment

The Clouds, Aerosol, and Precipitation in the Marine Boundary Layer (CAP-MBL) deployment at Graciosa Island in the Azores generated a 21 month (April 2009-December 2010) comprehensive dataset documenting clouds, aerosols and precipitation using the Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF). The scientific aim of the deployment is to gain improved understanding of the interactions of clouds, aerosols and precipitation in the marine boundary layer. Graciosa Island straddles the boundary between the subtropics and midlatitudes in the Northeast Atlantic Ocean, and consequently experiences a great diversity of meteorological and cloudiness conditions. Low clouds are the dominant cloud type, with stratocumulus and cumulus occurring regularly. Approximately half of all clouds contained precipitation detectable as radar echoes below the cloud base. Radar and satellite observations show that clouds with tops from 1- 11 km contribute more or less equally to surface-measured precipitation at Graciosa. A wide range of aerosol conditions was sampled during the deployment consistent with the diversity of sources as indicated by back trajectory analysis. Preliminary findings suggest important two-way interactions between aerosols and clouds at Graciosa, with aerosols affecting light precipitation and cloud radiative properties while being controlled in part by precipitation scavenging. The data from at Graciosa are being compared with short-range forecasts made a variety of models. A pilot analysis with two climate and two weather forecast models shows that they reproduce the observed time-varying vertical structure of lower-tropospheric cloud fairly well, but the cloud-nucleating aerosol concentrations less well. The Graciosa site has been chosen to be a permanent fixed ARM site that became operational in October 2013.

clouds↗

Concomitant Cisplatin and Hyperfractionated Radiotherapy in Locally Advanced Head and Neck Cancer: 10-Year Follow-Up of a Randomized Phase III Trial (SAKK 10/94)

Purpose: To compare the long-term outcome of treatment with concomitant cisplatin and hyperfractionated radiotherapy versus treatment with hyperfractionated radiotherapy alone in patients with locally advanced head and neck cancer. Methods and Materials: From July 1994 to July 2000, a total of 224 patients with squamous cell carcinoma of the head and neck were randomized to receive either hyperfractionated radiotherapy alone (median total dose, 74.4 Gy; 1.2 Gy twice daily; 5 days per week) or the same radiotherapy combined with two cycles of cisplatin (20 mg/m{sup 2} for 5 consecutive days during weeks 1 and 5). The primary endpoint was the time to any treatment failure; secondary endpoints were locoregional failure, metastatic failure, overall survival, and late toxicity assessed according to Radiation Therapy Oncology Group criteria. Results: Median follow-up was 9.5 years (range, 0.1-15.4 years). Median time to any treatment failure was not significantly different between treatment arms (hazard ratio [HR], 1.2 [95% confidence interval {l_brace}CI{r_brace}, 0.9-1.7; p = 0.17]). Rates of locoregional failure-free survival (HR, 1.5 [95% CI, 1.1-2.1; p = 0.02]), distant metastasis-free survival (HR, 1.6 [95% CI, 1.1-2.5; p = 0.02]), and cancer-specific survival (HR, 1.6 [95% CI, 1.0-2.5; p = 0.03]) were significantly improved in the combined-treatment arm, with no difference in major late toxicity between treatment arms. However, overall survival was not significantly different (HR, 1.3 [95% CI, 0.9-1.8; p = 0.11]). Conclusions: After long-term follow-up, combined-treatment with cisplatin and hyperfractionated radiotherapy maintained improved rates of locoregional control, distant metastasis-free survival, and cancer-specific survival compared to that of hyperfractionated radiotherapy alone, with no difference in major late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adding Erlotinib to Chemoradiation Improves Overall Survival but Not Progression-Free Survival in Stage III Non-Small Cell Lung Cancer

Purpose: To test, in a single-arm, prospective, phase 2 trial, whether adding the epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor erlotinib to concurrent chemoradiotherapy for previously untreated, locally advanced, inoperable non-small cell lung cancer would improve survival and disease control without increasing toxicity. Methods and Materials: Forty-eight patients with previously untreated non-small cell lung cancer received intensity modulated radiation therapy (63 Gy/35 fractions) on Monday through Friday, with chemotherapy (paclitaxel 45 mg/m², carboplatin area under the curve [AUC] = 2) on Mondays, for 7 weeks. All patients also received the EGFR tyrosine kinase inhibitor erlotinib (150 mg orally 1/d) on Tuesday-Sunday for 7 weeks, followed by consolidation paclitaxel–carboplatin. The primary endpoint was time to progression; secondary endpoints were overall survival (OS), toxicity, response, and disease control and whether any endpoint differed by EGFR mutation status. Results: Of 46 patients evaluable for response, 40 were former or never-smokers, and 41 were evaluable for EGFR mutations (37 wild-type [WT] and 4 mutated [all adenocarcinoma]). Median time to progression was 14.0 months and did not differ by EGFR status. Toxicity was acceptable (no grade 5, 1 grade 4, 11 grade 3). Twelve patients (26%) had complete responses (10 WT, 2 mutated), 27 (59%) partial (21 WT, 2 mutated, 4 unknown), and 7 (15%) none (6 WT, 2 mutated, 1 unknown) (P=.610). At 37.0 months' follow-up (range, 3.6-76.5 months) for all patients, median OS time was 36.5 months, and 1-, 2-, and 5-year OS rates were 82.6%, 67.4%, and 35.9%, respectively; none differed by mutation status. Twelve patients had no progression, and 34 had local and/or distant failure. Eleven of 27 distant failures were in the brain (7 WT, 3 mutated, 1 unknown). Conclusions: Toxicity and OS were promising, but time to progression did not meet expectations. The prevalence of distant failures underscores the need for effective systemic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A case report on bilateral partial breast irradiation using SAVI

To assess dosimetric parameters in a case study where bilateral accelerated partial breast irradiation (APBI) is delivered using a strut-adjusted volume implant (SAVI) device. A 59-year-old female received APBI in both breasts over 5 days, with fractions of 3.4 Gy twice daily. A Vac-lok system was used for immobilization, and a C-arm was used for daily imaging. We generated dose-volume histograms (DVHs) for the brachytherapy plans to derive several important biologic factors. We calculated the normal tissue complication probability (NTCP), equivalent uniform dose (EUD), and tumor control probability (TCP) using the Lyman-Kutcher-Burman model parameters {alpha} = 0.3 Gy{sup -1}, {alpha}/{beta} = 4 Gy, n = 0.1, and m = 0.3. In addition, we assessed the dose homogeneity index (DHI), overdose index, and dose nonuniformity ratio. D95 was >95% and V150 was <50 mL for both breasts. The DHIs were 0.469 and 0.512 for the left and right breasts, respectively. The EUDs (normalized to 3.4 Gy b.i.d.) were 33.53 and 29.10 Gy. The TCPs were estimated at 99.2% and 99.9%, whereas the NTCP values were 4.2% and 2.57%. In this clinical case, we were able to quantify the dosimetric parameters of an APBI treatment performed with a SAVI device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radio frequency reflectometry and charge sensing of a precision placed donor in silicon

We compare charge transitions on a deterministic single P donor in silicon using radio frequency reflectometry measurements with a tunnel coupled reservoir and DC charge sensing using a capacitively coupled single electron transistor (SET). By measuring the conductance through the SET and comparing this with the phase shift of the reflected radio frequency (RF) excitation from the reservoir, we can discriminate between charge transfer within the SET channel and tunneling between the donor and reservoir. The RF measurement allows observation of donor electron transitions at every charge degeneracy point in contrast to the SET conductance signal where charge transitions are only observed at triple points. The tunnel coupled reservoir has the advantage of a large effective lever arm (∼35%), allowing us to independently extract a neutral donor charging energy ∼62 ± 17 meV. These results demonstrate that we can replace three terminal transistors by a single terminal dispersive reservoir, promising for high bandwidth scalable donor control and readout.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗