Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Three-dimensional nanoscale characterisation of materials by atom probe tomography

The development of three-dimensional (3D), characterization techniques with high spatial and mass resolution is crucial for understanding and developing advanced materials for many engineering applications as well as for understanding natural materials. In recent decades, atom probe tomography (APT) which combines a point projection microscope and time-of-flight mass spectrometer has evolved to be an excellent characterization technique capable of providing 3D nanoscale characterization of materials with sub-nanometer scale spatial resolution, with equal sensitivity for all elements. This review discusses the current state as of beginning of the year 2016 of APT instrumentation, new developments in sample preparation methods, experimental procedures for different material classes, reconstruction of APT results, the current status of correlative microscopy, and application of APT for microstructural characterization in established scientific areas like structural materials as well as new applications in semiconducting nanowires, semiconductor devices, battery materials, catalyst materials, geological materials and biological materials. Finally, a brief perspective is given regarding the future of APT.

Atom Probe Tomography, characterization, microstru↗

Computer synthesis of high resolution electron micrographs

Specimen damage, spherical aberration, low contrast and noisy sensors combine to prevent direct atomic viewing in a conventional electron microscope. The paper describes two methods for obtaining ultra-high resolution in biological specimens under the electron microscope. The first method assumes the physical limits of the electron objective lens and uses a series of dark field images of biological crystals to obtain direct information on the phases of the Fourier diffraction maxima; this information is used in an appropriate computer to synthesize a large aperture lens for a 1-A resolution. The second method assumes there is sufficient amplitude scatter from images recorded in focus which can be utilized with a sensitive densitometer and computer contrast stretching to yield fine structure image details. Cancer virus characterization is discussed as an illustrative example. Numerous photographs supplement the text.

Nathan, R.↗

Shape controlled synthesis of CaMoO{sub 4} thin films and their photoluminescence property

CaMoO{sub 4} (CMO) disordered and ordered thin films were prepared by the complex polymerization method (CPM). The films were annealed at different temperatures and time in a conventional resistive furnace (RF) and in a microwave (MW) oven. The microstructure and surface morphology of the structure were monitored by atomic force microscopy (AFM) and high-resolution scanning electron microscopy (HRSEM). Order and disorder were characterized by X-ray diffraction (XRD) and optical reflectance. A strong photoluminescence (PL) emission was observed in the disordered thin films and was attributed to complex cluster vacancies. The experimental results were compared with density functional and Hartree-Fock calculations. - Graphical abstract: CaMoO{sub 4} thin films were prepared by the complex polymerization method (CPM). The films were annealed at different temperatures and time in a conventional resistive furnace and in a microwave oven. A strong photoluminescence emission was observed in the disordered thin films and was attributed to complex cluster vacancies. The experimental results were confirmed by high level first principle calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increasing the electron-transfer ability of Cyanidioschyzon merolae ferredoxin by a one-point mutation – A high resolution and Fe-SAD phasing crystal structure analysis of the Asp58Asn mutant

Highlights: •A single amino acid change on the ferredoxin surface affects electron transfer. •Precise positions of amide atoms were located utilizing no prior structural data. •Ultra high resolution and SAD phasing may be used for bias-free model building. -- Abstract: Cyanidioschyzon merolae (Cm) is a single cell red algae that grows in rather thermophilic (40–50 °C) and acidic (pH 1–3) conditions. Ferredoxin (Fd) was purified from this algae and characterized as a plant-type [2Fe–2S] Fd by physicochemical techniques. A high resolution (0.97 Å) three-dimensional structure of the CmFd D58N mutant molecule has been determined using the Fe-SAD phasing method to clarify the precise position of the Asn58 amide, as this substitution increases the electron-transfer ability relative to wild-type CmFd by a factor of 1.5. The crystal structure reveals an electro-positive surface surrounding Asn58 that may interact with ferredoxin NADP{sup +} reductase or cytochrome c.

60 APPLIED LIFE SCIENCES↗

Vibrational spectra of nanowires measured using laser doppler vibrometry and STM studies of epitaxial graphene : an LDRD fellowship report.

A few of the many applications for nanowires are high-aspect ratio conductive atomic force microscope (AFM) cantilever tips, force and mass sensors, and high-frequency resonators. Reliable estimates for the elastic modulus of nanowires and the quality factor of their oscillations are of interest to help enable these applications. Furthermore, a real-time, non-destructive technique to measure the vibrational spectra of nanowires will help enable sensor applications based on nanowires and the use of nanowires as AFM cantilevers (rather than as tips for AFM cantilevers). Laser Doppler vibrometry is used to measure the vibration spectra of individual cantilevered nanowires, specifically multiwalled carbon nanotubes (MWNTs) and silver gallium nanoneedles. Since the entire vibration spectrum is measured with high frequency resolution (100 Hz for a 10 MHz frequency scan), the resonant frequencies and quality factors of the nanowires are accurately determined. Using Euler-Bernoulli beam theory, the elastic modulus and spring constant can be calculated from the resonance frequencies of the oscillation spectrum and the dimensions of the nanowires, which are obtained from parallel SEM studies. Because the diameters of the nanowires studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate the lower diameter limit for nanowires whose vibration can be measured in this way. The techniques developed in this thesis can be used to measure the vibrational spectra of any suspended nanowire with high frequency resolution Two different nanowires were measured - MWNTs and Ag{sub 2}Ga nanoneedles. Measurements of the thermal vibration spectra of MWNTs under ambient conditions showed that the elastic modulus, E, of plasma-enhanced chemical vapor deposition (PECVD) MWNTs is 37 {+-} 26 GPa, well within the range of E previously reported for CVD-grown MWNTs. Since the Ag{sub 2}Ga nanoneedles have a greater optical scattering efficiency than MWNTs, their vibration spectra was more extensively studied. The thermal vibration spectra of Ag{sub 2}Ga nanoneedles was measured under both ambient and low-vacuum conditions. The operational deflection shapes of the vibrating Ag{sub 2}Ga nanoneedles was also measured, allowing confirmation of the eigenmodes of vibration. The modulus of the crystalline nanoneedles was 84.3 {+-} 1.0 GPa. Gas damping is the dominate mechanism of energy loss for nanowires oscillating under ambient conditions. The measured quality factors, Q, of oscillation are in line with theoretical predictions of air damping in the free molecular gas damping regime. In the free molecular regime, Q{sub gas} is linearly proportional to the density and diameter of the nanowire and inversely proportional to the air pressure. Since the density of the Ag{sub 2}Ga nanoneedles is three times that of the MWNTs, the Ag{sub 2}Ga nanoneedles have greater Q at atmospheric pressures. Our initial measurements of Q for Ag{sub 2}Ga nanoneedles in low-vacuum (10 Torr) suggest that the intrinsic Q of these nanoneedles may be on the order of 1000. The epitaxial carbon that grows after heating (000{bar 1}) silicon carbide (SiC) to high temperatures (1450-1600) in vacuum was also studied. At these high temperatures, the surface Si atoms sublime and the remaining C atoms reconstruct to form graphene. X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM) were used to characterize the quality of the few-layer graphene (FLG) surface. The XPS studies were useful in confirming the graphitic composition and measuring the thickness of the FLG samples. STM studies revealed a wide variety of nanometer-scale features that include sharp carbon-rich ridges, moire superlattices, one-dimensional line defects, and grain boundaries. By imaging these features with atomic scale resolution, considerable insight into the growth mechanisms of FLG on the carbon-face of SiC is obtained.

36 MATERIALS SCIENCE↗

High-resolution laser spectroscopy between 0.9 and 14.3 THz in a supersonic beam: Rydberg-Rydberg transitions of atomic Xe at intermediate n values

A laser-based, pulsed, narrow-band source of submillimeter-wave radiation has been developed that is continuously tunable from 0.1 THz to 14.3 THz. The source is based on difference-frequency mixing in the nonlinear crystal trans-4{sup Prime }-(dimethylamino)-N-methyl-4-stilbazolium tosylate. By varying the pulse length, the bandwidth of the submillimeter-wave radiation can be adjusted between 85 MHz and 2.8 MHz. This new radiation source has been integrated in a vacuum-ultraviolet-submillimeter-ware double-resonance spectrometer, with which low-frequency transitions of atoms and molecules in supersonic beams can be detected mass-selectively by photoionization and time-of-flight mass spectrometry. The properties of the radiation source and spectrometer are demonstrated in a study of 33f Leftwards-Arrow nd Rydberg-Rydberg transitions in Xe with n in the range 16-31. The frequency calibration of the submillimeter-wave radiation was performed with an accuracy of 2.8 MHz. The narrowest lines observed experimentally have a full-width at half-maximum of {approx}3 MHz, which is sufficient to fully resolve the hyperfine structure of the Rydberg-Rydberg transitions of {sup 129}Xe and {sup 131}Xe. A total of 72 transitions were measured in the range between 0.937 THz and 14.245 THz and their frequencies are compared with frequencies calculated by multichannel quantum defect theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the use of logarithmic scales for analysis of diffraction data

Conventional and free R factors and their difference, as well as the ratio of the number of measured reflections to the number of atoms in the crystal, were studied as functions of the resolution at which the structures were reported. When the resolution was taken uniformly on a logarithmic scale, the most frequent values of these functions were quasi-linear over a large resolution range. Predictions of the possible model parameterization and of the values of model characteristics such as R factors are important for macromolecular refinement and validation protocols. One of the key parameters defining these and other values is the resolution of the experimentally measured diffraction data. The higher the resolution, the larger the number of diffraction data N{sub ref}, the larger its ratio to the number N{sub at} of non-H atoms, the more parameters per atom can be used for modelling and the more precise and detailed a model can be obtained. The ratio N{sub ref}/N{sub at} was calculated for models deposited in the Protein Data Bank as a function of the resolution at which the structures were reported. The most frequent values for this distribution depend essentially linearly on resolution when the latter is expressed on a uniform logarithmic scale. This defines simple analytic formulae for the typical Matthews coefficient and for the typically allowed number of parameters per atom for crystals diffracting to a given resolution. This simple dependence makes it possible in many cases to estimate the expected resolution of the experimental data for a crystal with a given Matthews coefficient. When expressed using the same logarithmic scale, the most frequent values for R and R{sub free} factors and for their difference are also essentially linear across a large resolution range. The minimal R-factor values are practically constant at resolutions better than 3 Å, below which they begin to grow sharply. This simple dependence on the resolution allows the prediction of expected R-factor values for unknown structures and may be used to guide model refinement and validation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heterogeneity in M. tuberculosis β-lactamase inhibition by Sulbactam

Abstract For decades, researchers have elucidated essential enzymatic functions on the atomic length scale by tracing atomic positions in real-time. Our work builds on possibilities unleashed by mix-and-inject serial crystallography (MISC) at X-ray free electron laser facilities. In this approach, enzymatic reactions are triggered by mixing substrate or ligand solutions with enzyme microcrystals. Here, we report in atomic detail (between 2.2 and 2.7 Å resolution) by room-temperature, time-resolved crystallography with millisecond time-resolution (with timepoints between 3 ms and 700 ms) how the Mycobacterium tuberculosis enzyme BlaC is inhibited by sulbactam (SUB). Our results reveal ligand binding heterogeneity, ligand gating, cooperativity, induced fit, and conformational selection all from the same set of MISC data, detailing how SUB approaches the catalytic clefts and binds to the enzyme noncovalently before reacting to a trans- enamine. This was made possible in part by the application of singular value decomposition to the MISC data using a program that remains functional even if unit cell parameters change up to 3 Å during the reaction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Revealing the Atomic Structures of Exposed Lateral Surfaces for Polymorphic Manganese Dioxide Nanowires

Polymorphic 1D MnO 2 nanostructures are widely applied in fields such as catalysis, sensing, and energy storage with the functionality mainly determined by the atomic patterns of their laterally exposed facets, which largely remain unclear so far. Herein, by high‐resolution transmission electron microscopy (HRTEM) imaging directly along their axial directions, the atomic structures of the outmost lateral facets of polymorphic MnO 2 nanowires are disclosed. To generalize the findings, four most commonly seen phases with characteristic tunnel structures are targeted, i.e., β‐, γ‐, α‐, and todorokite(t)‐MnO 2 , which are synthesized conventionally using a hydrothermal method reported in the literature. Axially imaging these MnO 2 nanowires via HRTEM, the {hkl} facets covering the lateral surfaces are accurately indexed, the atomic pattern of each {hkl} facet is revealed, and it is further coupled with the outmost tunnel configuration that can significantly affect the physicochemical property of MnO 2 materials via tunnel‐driven mass adsorption/transport. This work provides a reliable reference for atomic modeling of MnO 2 to benefit the pursuit of its structure–property relationship; in addition, it can benefit surface engineering strategies to better rationalize the facet growth control with optimized functionality.

Yuan, Yifei↗

Graphene-enabled electron microscopy and correlated super-resolution microscopy of wet cells

The application of electron microscopy to hydrated biological samples has been limited by high-vacuum operating conditions. Traditional methods utilize harsh and laborious sample dehydration procedures, often leading to structural artefacts and creating difficulties for correlating results with high-resolution fluorescence microscopy. Here, we utilize graphene, a single-atom-thick carbon meshwork, as the thinnest possible impermeable and conductive membrane to protect animal cells from vacuum, thus enabling high-resolution electron microscopy of wet and untreated whole cells with exceptional ease. Our approach further allows for facile correlative super-resolution and electron microscopy of wet cells directly on the culturing substrate. In particular, individual cytoskeletal actin filaments are resolved in hydrated samples through electron microscopy and well correlated with super-resolution results.

Science & Technology - Other Topics↗

Protein crystallography with a micrometre-sized synchrotron-radiation beam

For the first time, protein microcrystallography has been performed with a focused synchrotron-radiation beam of 1 µm using a goniometer with a sub-micrometre sphere of confusion. The crystal structure of xylanase II has been determined with a flux density of about 3 × 10{sup 10} photons s{sup −1} µm{sup −2} at the sample. For the first time, protein microcrystallography has been performed with a focused synchrotron-radiation beam of 1 µm using a goniometer with a sub-micrometre sphere of confusion. The crystal structure of xylanase II has been determined with a flux density of about 3 × 10{sup 10} photons s{sup −1} µm{sup −2} at the sample. Two sets of diffraction images collected from different sized crystals were shown to comprise data of good quality, which allowed a 1.5 Å resolution xylanase II structure to be obtained. The main conclusion of this experiment is that a high-resolution diffraction pattern can be obtained from 20 µm{sup 3} crystal volume, corresponding to about 2 × 10{sup 8} unit cells. Despite the high irradiation dose in this case, it was possible to obtain an excellent high-resolution map and it could be concluded from the individual atomic B-factor patterns that there was no evidence of significant radiation damage. The photoelectron escape from a narrow diffraction channel is a possible reason for reduced radiation damage as indicated by Monte Carlo simulations. These results open many new opportunities in scanning protein microcrystallography and make random data collection from microcrystals a real possibility, therefore enabling structures to be solved from much smaller crystals than previously anticipated as long as the crystallites are well ordered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adsorption and Reaction of Acetone over CeOX(111) Thin Films

This study reports the interaction of acetone (CH3COCH3), the simplest ketone, with well ordered CeO2(111) thin film surfaces. The fully oxidized CeO2(111) surface shows a weak interaction with acetone with the sole desorption product (TPD) being acetone at 210 K. The chemisorbed molecule binds to the surface as the ?1-acetone species rather than through a bridge-bonded dioxy-configuration. Exposure of a CeO2(111) surface to acetone at 600K removes oxygen as CO and results in the conversion of Ce4+ to Ce3+. Acetone chemisorbs strongly on reduced CeO2-x(111) with molecular acetone desorbing near 500 K. Decomposition also occurs with H2 desorbing between 450 and 600 K and C reacting with O in the ceria to desorb above 650 K. A stable species exists from 200 to 500 K on the reduced surface that has three unique types of C. High resolution C 1s XPS spectra indicate these are Ce-CH2, C-CH3 and C-O species. C k-edge NEXAFS indicates the presence of C{double_bond}C and C{double_bond}O bonds. It is postulated that the intermediate is a carbanion bonded through both O and C atoms to Ce cations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing nanoscale scanning probes using electron microscopy: A novel fixture and a practical guide

The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic Oxygen Abundance in Molecular Clouds: Absorption Toward Sagittarius B2

We have obtained high-resolution (approximately 35 km/s) spectra toward the molecular cloud Sgr B2 at 63 micrometers, the wavelength of the ground-state fine-structure line of atomic oxygen (O(I)), using the ISO-LWS instrument. Four separate velocity components are seen in the deconvolved spectrum, in absorption against the dust continuum emission of Sgr B2. Three of these components, corresponding to foreground clouds, are used to study the O(I) content of the cool molecular gas along the line of sight. In principle, the atomic oxygen that produces a particular velocity component could exist in any, or all, of three physically distinct regions: inside a dense molecular cloud, in the UV illuminated surface layer (PDR) of a cloud, and in an atomic (H(I)) gas halo. For each of the three foreground clouds, we estimate, and subtract from the observed O(I) column density, the oxygen content of the H(I) halo gas, by scaling from a published high-resolution 21 cm spectrum. We find that the remaining O(I) column density is correlated with the observed (13)CO column density. From the slope of this correlation, an average [O(I)]/[(13)CO] ratio of 270 +/- 120 (3-sigma) is derived, which corresponds to [O(I)]/[(13)CO] = 9 for a CO to (13)CO abundance ratio of 30. Assuming a (13)CO abundance of 1x10(exp -6) with respect to H nuclei, we derive an atomic oxygen abundance of 2.7x10(exp -4) in the dense gas phase, corresponding to a 15% oxygen depletion compared to the diffuse ISM in our Galactic neighborhood. The presence of multiple, spectrally resolved velocity components in the Sgr B2 absorption spectrum allows, for the first time, a direct determination of the PDR contribution to the O(I) column density. The PDR regions should contain O(I) but not (13)CO, and would thus be expected to produce an offset in the O(I)-(13)CO correlation. Our data do not show such an offset, suggesting that within our beam O(I) is spatially coexistent with the molecular gas, as traced by (13)CO. This may be a result of the inhomogeneous nature of the clouds.

Lis, D. C.↗

On the Efficiency $\eta$ and the Homogeneity of TiN Kinetic Inductance Detectors Produced through Atomic Layer Deposition

Microwave Kinetic Inductance Detectors (MKIDs) belong to non-equilibrium superconducting devices. It is a new promising device due to high quantum efficiency, low theoretical noise limit, multiplex frequency domain, photon-number-resolving, and energy resolving. In the case of MKIDs, a change in the kinetic inductance is produced by the breaking of Cooper pairs, modifying the electrodynamic response of the superconductor. The production process of an MKID consists of depositing a superconducting thin film on an insulating substrate and applying standard lithographic patterning techniques to produce a resonator structure. When an MKID is produced via sputtering, film nonuniformity is observed, producing instability, low yield, frequency collisions, and low energy resolution. We exploring film uniformity in films produced with Atomic Layer Deposition (ALD) and through ALD archive high values in the energy resolution. The uniformity of ALD is evaluated via measurement of the critical temperature of 4 MKIDs. Two MKIDs belong to the first fabrication process and the other two to another. The results obtained are: ΔTc/max(σT1,σT2) is 0.45 for A1-B1 and 0.21 for A2-B2. The difference in the Tc for MKIDs of the same wafer is around 5.1 mK and from different wafers, the maximum difference is 66 mk with a minimum of 48 mK. However, with the high uniformity archived, we obtained a poor response of the MKIDs when a photon is absorbed. As a consequence of the low response, we examined in the literature about the process of photon absorption. In this evaluation, we were focusing on the down-conversion efficiency as a possible cause for the degraded energy resolution. In this process, one part of the initial energy of the photon is lost, transferred to the creation of quasiparticles and phonons. The phonons that do not possess enough energy to break a Cooper pair are lost from the system. This loss in energy is accounted for by the eff iciency η which has a constant value reported as 0.57 (! from simulation). Due to the efficiency had been reported always as constant. We proceed to evaluate its value through a new method. The process consists of measuring the gain of the system via the photon transfer curve and thermal calibration. The efficiency obtained with this new method is of 0.008 which has a lower value in comparison with the simulation. The methods to obtain the critical temperature, as well as the new method to evaluate the efficiency of an MKID will be shown in this work.

43 PARTICLE ACCELERATORS↗