Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Critical Need for Plutonium and Uranium Isotopic Standards with Lower Uncertainties

Certified reference materials (CRMs) traceable to national and international safeguards database are a critical prerequisite for ensuring that nuclear measurement systems are free of systematic biases. CRMs are used to validate measurement processes associated with nuclear analytical laboratories. Diverse areas related to nuclear safeguards are impacted by the quality of the CRM standards available to analytical laboratories. These include: nuclear forensics, radio-chronometry, national and international safeguards, stockpile stewardship, nuclear weapons infrastructure and nonproliferation, fuel fabrication, waste processing, radiation protection, and environmental monitoring. For the past three decades the nuclear community is confronted with the strange situation that improvements in measurement data quality resulting from the improved accuracy and precision achievable with modern multi-collector mass spectrometers could not be fully exploited due to large uncertainties associated with CRMs available from New Brunswick Laboratory (NBL) that are used for instrument calibration and measurement control. Similar conditions prevail for both plutonium and uranium isotopic standards and for impurity element standards in uranium matrices. Herein, the current status of U and Pu isotopic standards available from NBL is reviewed. Critical areas requiring improvement in the quality of the nuclear standards to enable the U. S. and international safeguards community to utilize the full potential of modern multi-collector mass spectrometer instruments are highlighted.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-E-T-775: Use of Electronic Portal Imaging Device (EPID) for Quality Assurance (QA) of Electron Beams On Varian Truebeam System

Purpose: In a previous study we have demonstrated the feasibility of using EPID to QA electron beam parameters on a single Varian TrueBeam LINAC. This study aims to provide further investigation on (1) reproducibility of using EPID to detect electron beam energy changes on multiple machines and (2) evaluation of appropriate calibration methods to compare results from different EPIDs. Methods: Ad-hoc mode electron beam images were acquired in developer mode with XML code. Electron beam data were collected on a total of six machines from four institutions. A custom-designed double-wedge phantom was placed on the EPID detector. Two calibration methods - Pixel Sensitivity Map (PSM) and Large Source-to-Imager Distance Flood Field (LSID-FF) - were used. To test the sensitivity of EPID in detecting energy drifts, Bending Magnet Current (BMC) was detuned to invoke energy changes corresponding to ∼±1.5 mm change in R50% of PDD on two machines from two institutions. Percent depth ionization (PDI) curves were then analyzed and compared with the respective baseline images using LSID-FF calibration. For reproducibility testing, open field EPID images and images with a standard testing phantom were collected on multiple machines. Images with and without PSM correction for same energies on different machines were overlaid and compared. Results: Two pixel shifts were observed in PDI curve when energy changes exceeded the TG142 tolerance. PSM showed the potential to correct the differences in pixel response of different imagers. With PSM correction, the histogram of images differences obtained from different machines showed narrower distributions than those images without PSM correction. Conclusion: EPID is sensitive for electron energy changes and the results are reproducible on different machines. When overlaying images from different machines, PSM showed the ability to partially eliminate the intrinsic variation of various imagers. Research Funding from Varian Medical Systems Inc.Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗

Measurement of ionization chamber absorbed dose k{sub Q} factors in megavoltage photon beams

Purpose: Absorbed dose beam quality conversion factors (k{sub Q} factors) were obtained for 27 different types of ionization chamber. The aim was to obtain objective evidence on the performance of a wide range of chambers currently available, and potentially used for reference dosimetry, and to investigate the accuracy of the k{sub Q} calculation algorithm used in the TG-51 protocol. Methods: Measurements were made using the {sup 60}Co irradiator and Elekta Precise linac facilities at the National Research Council of Canada. The objective was to characterize the chambers over the range of energies applicable to TG-51 and determine whether each chamber met the requirements of a reference-class instrument. Chamber settling, leakage current, ion recombination and polarity, and waterproofing sleeve effects were investigated, and absorbed dose calibration coefficients were obtained for {sup 60}Co and 6, 10, and 25 MV photon beams. Only thimble-type chambers were considered in this investigation and were classified into three groups: (i) Reference chambers (''standard''0.6 cm{sup 3} Farmer-type chambers and their derivatives traditionally used for beam output calibration); (ii) scanning chambers (typically 0.1 cm{sup 3} volume chambers used for beam commissioning with 3-D scanning phantoms); and (iii) microchambers (very small volume ion chambers ({<=}0.01 cm{sup 3}) used for small field dosimetry). Results: As might be expected, 0.6 cm{sup 3} thimble chambers showed the most predictable performance and experimental k{sub Q} factors were obtained with a relative uncertainty of 0.1%. The performance of scanning and microchambers was somewhat variable. Some chambers showed very good behavior but others showed anomalous polarity and recombination corrections that are not fully explained at present. For the well-behaved chambers, agreement between measured and calculated k{sub Q} factors was within 0.4%; for some chambers, differences of more than 1% were seen that may be related to the recombination/polarity results. Use of such chambers could result in significant errors in the determination of reference dose in the clinic. Conclusions: Based on the experimental evidence obtained here, specification for a reference-class ionization chamber could be developed that would minimize the error in using a dosimetry protocol with calculated beam quality conversion factors. The experimental k{sub Q} data obtained here for a wide range of thimble chambers can be used when choosing suitable detectors for reference dosimetry and are intended to be used in the upcoming update/addendum to the AAPM TG-51 dosimetry protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

Markham, Brian↗

Absolute Cavity Pyrgeometer to Measure the Absolute Outdoor Longwave Irradiance with Traceability to International System of Units, SI

This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180{sup o} view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U{sub 95}) of {+-}3.96 W m{sup 02} with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m{sup 2} lower than that measured by the two pyrgeometers that are traceable to WISG, with a standard deviation of {+-}0.7 W m{sup -2}. These results suggest that the ACP design might be used for addressing the need to improve the international reference for broadband outdoor longwave irradiance measurements.

14 SOLAR ENERGY↗

Constraining Cosmic Birefringence with Polarization Angle Calibration

The Cosmic Microwave Background (CMB) is a sensitive probe of cosmic birefringence, which, if detected, would imply physics beyond the standard model. For example, cosmic birefringence can be caused by axion-like pseudo scalar-fields coupling to photons via the Chern-Simons effect. These represent favored candidates for dark matter particles and are used in models to explain dark energy. However, measuring cosmic birefringence with CMB experiments requires exceptional polarization angle calibration to disentangle instrumental effects from this elusive signal. I will give an overview of the current state of the art in CMB polarization angle calibration on Simons Observatory and its implications for constraints on cosmic birefringence.

Simon, Sara M. [Fermilab] (ORCID:0000000192217802)↗

Constraining Cosmic Birefringence with Polarization Angle Calibration

The Cosmic Microwave Background (CMB) is a sensitive probe of cosmic birefringence, which, if detected, would imply physics beyond the standard model. For example, cosmic birefringence can be caused by axion-like pseudo scalar-fields coupling to photons via the Chern-Simons effect. These represent favored candidates for dark matter particles and are used in models to explain dark energy. However, measuring cosmic birefringence with CMB experiments requires exceptional polarization angle calibration to disentangle instrumental effects from this elusive signal. I will give an overview of the current state of the art in CMB polarization angle calibration on Simons Observatory and its implications for constraints on cosmic birefringence.

Simon, Sara M. [Fermilab] (ORCID:0000000192217802)↗

Technical Note: An investigation of polarity effects for wide-angle free-air chambers

Purpose: Wide-angle free-air chambers (WAFACs) are used as primary standard measurement devices for establishing the air-kerma strength of low-energy, low-dose rate brachytherapy seeds. The National Research Council of Canada (NRC) is commissioning a primary standard wide-angle free-air chamber (NRC WAFAC) to serve the calibration needs of Canadian clients. The University of Wisconsin has developed a similar variable-aperture free-air chamber (UW VAFAC) to be used as a research tool. As part of the NRC commissioning, measurements were carried out for both polarities of the applied bias voltage and the resulting effects were observed to be very large. Similar effects were identified with the UW VAFAC. The authors describe the measurements carried out to determine the underlying causes of the polarity effect and the approach used to eliminate it. Methods: The NRC WAFAC is based on the WAFAC design developed at the National Institute of Standards and Technology in the USA. Charge measurements for {sup 125}I and {sup 241}Am sources were carried out for both negative and positive polarities on the NRC WAFAC and UW VAFAC. Two aperture sizes were also investigated with the UW VAFAC. In addition, measurements on the NRC WAFAC were carried out with a small bias between the collecting electrode and the shield foil at the downstream end of the chamber. To mitigate all of the polarity effects, the downstream surface of the collecting electrode was covered with a thin layer of graphite on both the NRC and UW chambers. Results: Both chamber designs showed a difference of more than 30 % between the charge collected with positive and negative bias voltages for the smallest electrode separation. It was shown for the NRC WAFAC that charge could be collected in the small gap downstream of the collecting volume by applying a voltage between the shield foil and the collecting electrode, even though an insulating foil (Mylar or polyimide film) separated the conducting surface from the small gap region. The unwanted additional current was shown to be proportional to the size of the aperture for the UW VAFAC. The extra ionization produced in the small gap region was eliminated for both chambers by covering the insulating side of the collecting electrode with a grounded conducting layer. Conclusions: The small gap region downstream of the collecting electrode in the NRC WAFAC and UW VAFAC can serve as an unwanted source of ion current. It is concluded that a residual electric field in the small gap region may lead to ion transport and to charge being trapped on the surface of the foil. The foil then acts as a capacitor with an equal charge, but of opposite sign, being attracted to the conducting surface. Covering the back of the collecting electrode surface with a grounded conducting layer eliminated the polarity effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

Big Data Mining for Applied Energy Savings in Buildings

Residential and commercial buildings in China, India, the United States (US), United Kingdom (UK), and Italy consume 39-45% of each nation's primary energy (approximately 73% of electricity). Building energy models can be used to automatically optimize the return-on-investment for retrofits to improve a building’s energy efficiency. However, with an average of 3,000 building descriptors necessary to accurately simulate a single building, there is a market need to reduce the transaction cost for creating a simulatable model for every building in a city and calibrate the models to utility data prior to capital expenditures. Oak Ridge National Laboratory has utilized two of the world’s fastest supercomputers, assembled unique datasets, and developed innovative algorithms for big data mining to produce the Automatic detection and creation of Building Energy Models (AutoBEM) technology for urban-scale energy modeling. The project developed the world’s most accurate method for determining building footprints from satellite imagery and the world’s fastest building energy model generator. The team has also leveraged a total of eight supercomputers to analyze the best methods, metrics, and algorithms for calibrating building models to measured data within 4% of hourly electricity use; well beyond current industry standards necessary for private-sector financing. The project developed the world’s fastest buildings simulator, over 8 million simulations totaling over 200TB, and mined this data with over 130,000 parallel artificial intelligence algorithmic instances to develop the world’s best calibration algorithm in terms of accuracy, runtime, and robustness.

New, Joshua↗

NASA Glenn Icing Research Tunnel: 2019 Cloud Calibration Procedure and Results

The NASA Glenn Research Center 2019 Icing Research Tunnel cloud calibration results are presented in this paper. The current status of the cloud uniformity, liquid water content, and drop-size calibration results will be discussed. The goals achieved in this calibration were to establish a uniform cloud and to generate transfer functions from the inputs of airspeed, spray bar atomizing air pressure, and spray bar water pressure to the outputs of median volumetric diameter (drop size distributions) and liquid water content. This was completed for both 14 CFR Parts 25 and 29, Appendix C (“typical” icing) and Appendix O (supercooled large drop) conditions. The cloud uniformity from the Standard nozzles has remained the same as what was reported for the 2014 full calibration. Changes were made to the Mod1 nozzle cloud, resulting in higher liquid water content values associated with the Mod1 cloud.

Emily N. Timko↗

Demonstration of emulator-based Bayesian calibration of safety analysis codes: Theory and formulation

System codes for simulation of safety performance of nuclear plants may contain parameters whose values are not known very accurately. New information from tests or operating experience is incorporated into safety codes by a process known as calibration, which reduces uncertainty in the output of the code and thereby improves its support for decision-making. The work reported here implements several improvements on classic calibration techniques afforded by modern analysis techniques. The key innovation has come from development of code surrogate model (or code emulator) construction and prediction algorithms. Use of a fast emulator makes the calibration processes used here with Markov Chain Monte Carlo (MCMC) sampling feasible. This study uses Gaussian Process (GP) based emulators, which have been used previously to emulate computer codes in the nuclear field. The present work describes the formulation of an emulator that incorporates GPs into a factor analysis-type or pattern recognition-type model. This “function factorization” Gaussian Process (FFGP) model allows overcoming limitations present in standard GP emulators, thereby improving both accuracy and speed of the emulator-based calibration process. Calibration of a friction-factor example using a Method of Manufactured Solution is performed to illustrate key properties of the FFGP based process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-dose MVCT image guidance for stereotactic body radiation therapy

Purpose: Stereotactic body radiation therapy (SBRT) is a potent treatment for early stage primary and limited metastatic disease. Accurate tumor localization is essential to administer SBRT safely and effectively. Tomotherapy combines helical IMRT with onboard megavoltage CT (MVCT) imaging and is well suited for SBRT; however, MVCT results in reduced soft tissue contrast and increased image noise compared with kilovoltage CT. The goal of this work was to investigate the use of increased imaging doses on a clinical tomotherapy machine to improve image quality for SBRT image guidance. Methods: Two nonstandard, high-dose imaging modes were created on a tomotherapy machine by increasing the linear accelerator (LINAC) pulse rate from the nominal setting of 80 Hz, to 160 Hz and 300 Hz, respectively. Weighted CT dose indexes (wCTDIs) were measured for the standard, medium, and high-dose modes in a 30 cm solid water phantom using a calibrated A1SL ion chamber. Image quality was assessed from scans of a customized image quality phantom. Metrics evaluated include: contrast-to-noise ratios (CNRs), high-contrast spatial resolution, image uniformity, and percent image noise. In addition, two patients receiving SBRT were localized using high-dose MVCT scans. Raw detector data collected after each scan were used to reconstruct standard-dose images for comparison. Results: MVCT scans acquired using a pitch of 1.0 resulted in wCTDI values of 2.2, 4.7, and 8.5 cGy for the standard, medium, and high-dose modes respectively. CNR values for both low and high-contrast materials were found to increase with the square root of dose. Axial high-contrast spatial resolution was comparable for all imaging modes at 0.5 lp/mm. Image uniformity was improved and percent noise decreased as the imaging dose increased. Similar improvements in image quality were observed in patient images, with decreases in image noise being the most notable. Conclusions: High-dose imaging modes are made possible on a clinical tomotherapy machine by increasing the LINAC pulse rate. Increasing the imaging dose results in increased CNRs; making it easier to distinguish the boundaries of low contrast objects. The imaging dose levels observed in this work are considered acceptable at our institution for SBRT treatments delivered in 3-5 fractions.

60 APPLIED LIFE SCIENCES↗

Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom

Purpose: Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCTNs) to relative linear stopping powers (RLSPs). Various facilities engaged in multi-institutional clinical trials involving proton beams have been applying significantly different margins in their patient planning. This study was performed to determine the variance in the conversion functions used at proton facilities in the U.S.A. wishing to participate in National Cancer Institute sponsored clinical trials. Methods: A simplified method of determining the conversion function was developed using a standard phantom containing only water and aluminum. The new method was based on the premise that all scanners have their XCTNs for air and water calibrated daily to constant values but that the XCTNs for high density/high atomic number materials are variable with different scanning conditions. The standard phantom was taken to 10 different proton facilities and scanned with the local protocols resulting in 14 derived conversion functions which were compared to the conversion functions used at the local facilities. Results: For tissues within ±300 XCTN of water, all facility functions produced converted RLSP values within ±6% of the values produced by the standard function and within 8% of the values from any other facility's function. For XCTNs corresponding to lung tissue, converted RLSP values differed by as great as ±8% from the standard and up to 16% from the values of other facilities. For XCTNs corresponding to low-density immobilization foam, the maximum to minimum values differed by as much as 40%. Conclusions: The new method greatly simplifies determination of the conversion function, reduces ambiguity, and in the future could promote standardization between facilities. Although it was not possible from these experiments to determine which conversion function is most appropriate, the variation between facilities suggests that the margins used in some facilities to account for the uncertainty in converting XCTNs to RLSPs may be too small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive onsite assessment that includes proficiency testing and documentation review. The ATL NVLAP accreditation currently applies specifically to its ISO 3744 soundpower- level determination procedure (see the photograph) and supporting ISO 17025 quality system, although all ATL operations are conducted in accordance with its quality system. The ATL staff is currently developing additional procedures to adapt this quality system to the testing of space flight hardware in accordance with International Space Station acoustic emission requirements.<

Akers, James C.↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗