Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

The reactive bed plasma system for contamination control

The contamination control capabilities of the Reactive Bed Plasma (RBP) system is described by delineating the results of toxic chemical composition studies, aerosol filtration work, and other testing. The RBP system has demonstrated its capabilities to decompose toxic materials and process hazardous aerosols. The post-treatment requirements for the reaction products have possible solutions. Although additional work is required to meet NASA requirements, the RBP may be able to meet contamination control problems aboard the Space Station.

Birmingham, Joseph G.↗

Contamination control program for the Cosmic Background Explorer: An overview

Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.

Barney, Richard D.↗

Migration and generation of contaminants from launch through recovery: LDEF case history

The migration of contaminants to and between Long Duration Exposure Facility (LDEF) surfaces reveals new information relevant to all future space missions. The surface of the LDEF satellite closely paralleled over seven meters of the shuttle during one launch and one reentry. Transfer of contaminants from the shuttle bay to the payload were documented and partially quantified for both the launch and recovery separately. LDEF carried a load of volatile silicones and hydrocarbons into orbit which were then polymerized by UV radiation into tough, dark brown stains on exposed surfaces. The distribution of these stains is providing new information on deposition mechanisms that should be studied on future missions. Electrostatic effects, diffusional flow, and effects due to small surface temperature differences at the time of UV exposure are suggested. The types of functional groups present in the LDEF deposit it nearly identical to stains recovered from other spacecraft. These stains were remarkably stable in low Earth orbit even with atomic oxygen exposure if the amount of silicones present was sufficient to create a sealing layer of silicon dioxide over the dark brown stain beneath.

Crutcher, E. Russ↗

Contamination control program for the Cosmic Background Explorer

Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.

Barney, Richard D.↗

Contamination study

The time dependence of the angular reflectance from molecularly contaminated optical surfaces in the Vacuum Ultraviolet (VUV) is measured. The light scattering measurements are accomplished in situ on optical surfaces in real time during deposition of molecular contaminants. The measurements are taken using non-coherent VUV sources with the predominant wavelengths being the Krypton resonance lines at 1236 and 1600 A. Detection of the scattered light is accomplished using a set of three solar blind VUV photomultipliers. An in-plane VUV BRDF (Bidirectional Reflectance Distribution Functions) experiment is described and details of the ongoing program to characterize optical materials exposed to the space environment is reported.

Johnson, R. Barry↗

XPS study of the effect of hydrocarbon contamination on polytetrafluoroethylene (teflon) exposed to atomic oxygen

The presence of hydrocarbon contamination on the surface of polytetrafluoroethylene (PTFE) markedly affects the oxygen uptake, and hence the wettability, of this polymer when exposed to an oxygen plasma. As revealed by X-ray photoelectron spectroscopy (XPS) analysis, the oxygen-to-carbon ratio (O/C) for such a polymer can increase sharply, and correspondingly the fluorine-to-carbon ratio (F/C) can decrease sharply, at very short exposure times; at longer times, however, such changes in the O/C and F/C ratios reverse direction, and these ratios then assume values similar to those of the unexposed PTFE. The greater the extent of hydrocarbon contamination in the PTFE, the larger are the amplitudes of the 'spikes' in the O/C- and F/C-exposure time plots. In contrast, a pristine PTFE experiences a very small, monotonic increase of surface oxidation or O/C ratio with time of exposure to oxygen atoms, while the F/C ratio is virtually unchanged from that of the unexposed polymer (2.0). Unless the presence of adventitious hydrocarbon is taken into account, anomalous surface properties relating to polymer adhesion may be improperly ascribed to PTFE exposed to an oxygen plasma.

Golub, Morton A.↗

Biological Contamination of Mars: Issues and Recommendations

The ad hoc Task Group on Planetary Protection formed by the Space Studies Board (SSB) of the National Research Council focused on making recommendations concerning the protection of Mars from forward contamination (i.e., Earth to Mars) during upcoming missions by both the United States and the former Soviet Union. In so doing, it distinguished between missions whose goals include reconnaissance and measurement and those that specifically include experiments to detect life. The task group also discussed what additional knowledge will be needed in order to assure that future recommendations regarding contamination of Earth from Mars might be made with a higher degree of certainty than is now possible. Following a short introduction to the rationale underlying planetary exploration (Chapter 1) is a brief summary of approved and contemplated missions to Mars (Chapter 2). Chapter 3 briefly reviews the state of knowledge in several areas pertinent to the problem of planetary protection, in the limits of life on Earth and the abilities of known terrestrial organisms to withstand extreme environment conditions, as well as new approaches to detecting life forms. Chapter 5 includes a review and comments (made in light of current knowledge)- on the recommendations made in 'Recommendations on Quarantine Policy for Mars, Jupiter, Saturn, Uranus, Neptune, and Titan'. Updates to the recommendations made in 1978 are also given in Chapter 5. Chapter 6 gives additional recommendations concerning collection of essential data, spacecraft sterilization and bioburden assessment, and future research, as well as legal and social issues and NASA's overall planetary protection program.

Source record↗

ESCA study of the effect of hydrocarbon contamination on poly(tetrafluoroethylene) exposed to atomic oxygen plasma

The ESCA spectra and data obtained by Morra et al. (1989) on poly(tetrafluoroethylene) (PTFE) exposed to atomic oxygen plasma are closely reexamined. It is shown that the spikes observed in Morra et al. plots of O/C or F/C versus time of the exposure of PTFE to atomic oxygen plasma were not characteristic of PTFE per se but were instead a result of a contamination by hydrocarbon present in their PTFE samples. This was demonstrated experimentally by comparing data derived for a very clean PTFE sample exposed for 10, 20, and 30 min to oxygen plasma with data obtained on PTFE samples with very small amounts of hydrocarbon contamination.

Golub, Morton A.↗

Xylan - A potential contaminant for lunar samples and Antarctic meteorites

The possibility that lunar samples have been contaminated by the proprietary lubricant paint known as Xylan, which has been applied to screw threads in dry-N sample processing cabinets at NASA JSC, is considered. From a sample analysis using sealed-tube and stepped combustion, it is argued that the unexpectedly high concentration of organic materials found in EET A79001 is not due to Xylan contamination. It is considered unlikely that previous C and N analyses of lunar samples have been affected by the introduction of Xylan.

Wright, I. P.↗

The characterization of organic contaminants during the development of the Space Station water reclamation and management system

Examples of the application of various methods for characterizing samples for alcohols, fatty acids, detergents, and volatile/semivolatile basic, neutral, and phenolic acid contaminants are presented. Data, applications, and interpretations are given for a variety of methods including sample preparation/cleanup procedures, ion chromatography, and gas chromatography with various detectors. Summaries of the major organic contaminants that contribute to the total organic carbon content are presented.

Cole, H.↗

Fluorescence Reveals Contamination From Adhesives

Contamination of nearby surfaces from ingredients in some adhesive materials detected by ultraviolet illumination and observation of resulting fluorescence. Identification of contaminants via telltale fluorescence not new; rather, significance lies in method of implementation and potential extension to wider variety of materials and applications.

Nikolia, William↗

Swept wing attachment line contamination fence

A device for controlling attachment line contamination on an airfoil is presented. A fence is installed on the leading edge of the airfoil in the freestream direction perpendicular to the airfoil, outboard of the fuselage boundary layer. The inboard side of the fence arrests the spanwise movement of the turbulent boundary layer while the laminar boundary layer on the outboard side of the fence eliminates any further turbulent contamination of the attachment line.

Holmes, Bruce J.↗

Increased Fire and Toxic Contaminant Detection Responsibility by Use of Distributed, Aspirating Sensors

Viewgraphs of increased fire and toxic contaminant detection responsivity by use of distributed, aspirating sensors for space station are presented. Objectives of the concept described are (1) to enhance fire and toxic contaminant detection responsivity in habitable regions of space station; (2) to reduce system weight and complexity through centralized detector/monitor systems; (3) to increase fire signature information from selected locations in a space station module; and (4) to reduce false alarms.

Youngblood, Wallace W.↗

Shuttle primary reaction control system engine exhaust plume contamination effects

Space Shuttle proximity operations constitute an important part of the SSF induced external environment. The impingement of primary reaction control system (PRCS) engine plumes on SSF functional surfaces during docking or berthing and separation leads to concerns about molecular contamination and high speed particle impact. The Shuttle Plume Impingement flight Experiment (SPIE) was designed to provide a direct measure of both the molecular contamination and particle impact rates produced by Shuttle PRCS engines in the LEO environment. The measured permanent deposition produced by PRCS engine firings was less than that assumed in current SSF programatic assessments. Only two to three possible high velocity particle impact pits were observed on the RMS end effector hardware.

Koontz, Steve↗

Molecular contamination and the calibration of AXAF

By the end of this decade, the two missions comprising the Advanced X-ray Astrophysics Facility (AXAF) will become the X-ray component of NASA's Great Observatories. In order to meet some of the ambitious scientific objectives, the AXAF team plans to calibrate the telescopes and instruments to an accuracy of a few percent. Particulate and molecular contamination potentially limit this precision, because they would likely change between ground calibration and orbital operation. To avoid this requires careful control over procedures affecting the coated optical surfaces, to ensure that neither particulate nor molecular contamination compromise the calibration. In particular, the fractional areal coverage by particulates or condensed droplets must be less than 0.005 projected onto the aperture plane; the thickness of any molecular film must be less than a few tens of angstrom.

Elsner, R. F.↗

An assessment of the contamination acquired by IDPs during atmospheric deceleration

The E-layer of the terrestrial mesosphere, between 80 and 110 km altitude, is derived from meteoric ablation. Concentrations of Na and Fe, contributed by meteoric vapor, have been monitored in the mesosphere, and both individual meteors and average concentration profiles have been measured. Individual interplanetary dust particles (IDP's) entering the earth's atmosphere must pass through the mesospheric layers rich in meteoric volatile elements. Limits on the extent to which individual IDP's can be contaminated by meteoric volatile elements during deceleration in the upper atmosphere can be established by considering the extreme cases: the direct passage of an IDP through a meteoric vapor trail or the passage of an IDP through the mesospheric layer rich in meteoric volatiles. It appears the interaction of IDP's with meteoric vapor during deceleration in the upper atmosphere does not produce significant contamination of IDP's as they decelerate in the upper atmosphere.

Flynn, George J.↗

Surface characterization and contamination analysis

The research activity for this first year has focussed on three distinct activities: (1) the use of an integrating sphere to improve upon the gathering of spectral data from a variety of surfaces; (2) the use of optical fiber spectrometry to determine levels of contamination from tape residues on critical bonding surfaces; and (3) an exploratory activity in the use of spectroscopic ellipsometry for the analysis of thin films of contaminants on critical surfaces has also begun.

Workman, Gary L.↗

International Space Station Alpha trace contaminant control subassembly life test report

The Environmental Control and Life Support System (ECLSS) Life Test Program (ELTP) began with Trace Contaminant Control Subassembly (TCCS) Life Testing on November 9, 1992, at 0745. The purpose of the test, as stated in the NASA document 'Requirements for Trace Contaminant Control Subassembly High Temperature Catalytic Oxidizer Life Testing (Revision A)' was to 'provide for the long duration operation of the ECLSS TCCS HTCO (High Temperature Catalytic Oxidizer) at normal operating conditions... (and thus)... to determine the useful life of ECLSS hardware for use on long duration manned space missions.' Specifically, the test was designed to demonstrate thermal stability of the HTCO catalyst. The report details TCCS stability throughout the test. Graphs are included to aid in evaluating trends and subsystem anomalies. The report summarizes activities through the final day of testing, January 17, 1995 (test day 762).

Tatara, J. D.↗