Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Development of a Control Platform for a Building-Scale Hybrid Solar PV-Natural Gas Microgrid

Building-scale microgrids are a type of behind-the-meter microgrids where the building operator has control of the distributed energy resources, including, in this case, a natural gas-fired microturbine in addition to solar PV and battery energy storage systems. There is a growing trend in deploying behind-the-meter microgrids due to their benefits including the resiliency of serving critical loads, especially in regions with abundant natural gas. In order to ensure distributed energy resources are dispatched optimally for the desired mode of operation, a hierarchical control platform including a centralized controller was developed and installed. The platform includes communication and control infrastructure that interface with controllers for distributed energy resources and the building automation system of a recently built energy efficient commercial building. Based on desirable outcomes under different grid and building conditions, operational modes were defined for the microgrid controller. The controller is programmed to map each mode to respective operational modes for distributed energy resources controllers. Experimental data for test runs corresponding to two operational modes confirm the communication and control infrastructure can execute hierarchical control commands. Finally, dispatch optimization for a year-long simulation of system operation is presented and the benefits of the hybrid solar PV-natural gas setup are evaluated.

Energy & Fuels↗

Leveraging Real-World Driving Data for Design and Impact Evaluation of Energy Efficient Control Strategies

Modeling and simulation are crucial in the development of advanced energy efficient control strategies. Utilizing real-world driving data as the underlying basis for control design and simulation lends veracity to projected real-world energy savings. Standardized drive cycles are limited in their utility for evaluating advanced driving strategies that utilize connectivity and on-vehicle sensing, primarily because they are typically intended for evaluating emissions and fuel economy under controlled conditions. Real-world driving data, because of its scale, is a useful representation of various road types, driving styles, and driving environments. The scale of real-world data also presents challenges in effectively using it in simulations. A fast and efficient simulation methodology is necessary to handle the large number of simulations performed for design analysis and impact evaluation of control strategies. In this study, two methods are presented of leveraging real-world data in both design optimization of energy efficient control strategies and in evaluating the real-world impact of those control strategies upon large-scale deployment. Through these methodologies, strategies with highest impact on energy savings were selected to be implemented as control algorithms. The developed algorithms were incorporated into a vehicle dynamics and powertrain control architecture implemented on a Cadillac CT6 demonstration vehicle. The control algorithms were then exercised on real-world driving scenarios to determine their impact on collective energy savings. The methodology utilizes the large-scale driving data sets maintained by the National Renewable Energy Laboratory to extract real-world driving scenarios and efficient simulation software tools. The insights obtained through this research help in guiding technology selection for energy efficient driving controls.

ARPA-E↗

Electron beam energy stabilization using a neural network hybrid controller at the Australian Synchrotron Linac.

This paper describes the implementation of a neural network hybrid controller for energy stabilization at the Australian Synchrotron Linac. The structure of the controller consists of a neural network (NNET) feed forward control, augmented by a conventional Proportional-Integral (PI) feedback controller to ensure stability of the system. The system is provided with past states of the machine in order to predict its future state, and therefore apply appropriate feed forward control. The NNET is able to cancel multiple frequency jitter in real-time. When it is not performing optimally due to jitter changes, the system can successfully be augmented by the PI controller to attenuate the remaining perturbations. With a view to control the energy and bunch length at the FERMI{at}Elettra Free Electron Laser (FEL), the present study considers a neural network hybrid feed forward-feedback type of control to rectify limitations related to feedback systems, such as poor response for high jitter frequencies or limited bandwidth, while ensuring robustness of control. The Australian Synchrotron Linac is equipped with a beam position monitor (BPM), that was provided by Sincrotrone Trieste from a former transport line thus allowing energy measurements and energy control experiments. The present study will consequently focus on correcting energy jitter induced by variations in klystron phase and voltage.

43 PARTICLE ACCELERATORS↗

Contact Control, Version 1

The contact control code is a generalized force control scheme meant to interface with a robotic arm being controlled using the Robot Operating System (ROS). The code allows the user to specify a control scheme for each control dimension in a way that many different control task controllers could be built from the same generalized controller. The input to the code includes maximum velocity, maximum force, maximum displacement, and a control law assigned to each direction and the output is a 6 degree of freedom velocity command that is sent to the robot controller.

von Sternberg, Alex↗

Power inverter implementing phase skipping control

A power inverter includes a DC/AC inverter having first, second and third phase circuitry coupled to receive power from a power source. A controller is coupled to a driver for each of the first, second and third phase circuitry (control input drivers). The controller includes an associated memory storing a phase skipping control algorithm, wherein the controller is coupled to receive updating information including a power level generated by the power source. The drivers are coupled to control inputs of the first, second and third phase circuitry, where the drivers are configured for receiving phase skipping control signals from the controller and outputting mode selection signals configured to dynamically select an operating mode for the DC/AC inverter from a Normal Control operation and a Phase Skipping Control operation which have different power injection patterns through the first, second and third phase circuitry depending upon the power level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational control of fuel cells

Various examples are provided for operational control of fuel cells. In one example, among others, a system for controlling a fuel cell includes a stack temperature controller in cascade with a liquid level controller. The liquid level controller can provide a control output based at least in part upon an indication of a liquid level of a liquid fuel tank and a level reference. The stack temperature controller can provide a fan speed control output based at least in part upon an indication of a stack temperature of the fuel cell and the control output of the liquid level controller. In another example, a system for estimating methanol concentration of a fuel cell system includes a state observer that generates an estimate of the methanol concentration of fuel provided to a direct methanol fuel cell based upon a plurality of states of the fuel cell system.

42 ENGINEERING↗

Control circuits for asynchronous circuits

The described embodiments include a computing device with one or more asynchronous circuits and control circuits that control the operation of the asynchronous circuits. In some embodiments, the control circuits are arranged in a hierarchy with a top-level control circuit atop the hierarchy and one or more local control circuits lower in the hierarchy. In these embodiments, the top-level control circuit processes operating information for the one or more asynchronous circuits and/or other functional blocks in the computing device to determine an operating state for the computing device. Based on the operating state, the top-level control circuit communicates commands to the local control circuits to cause the local control circuits to operate in corresponding operating modes. Based on a corresponding operating mode command, each local control circuit sets one or more operating parameters for corresponding asynchronous circuits (and/or one or more other functional blocks).

42 ENGINEERING↗

Local access control system management using domain information updates

Systems and methods are presented for managing physical access to an access-controlled area using a local access control system. In certain embodiments, information that may be used in access control determinations managed by a remote domain controller may be communicated to a local access control system for use in connection with local access control determinations performed by the access control system independent of the domain controller. In some embodiments, such a configuration may allow for access control determinations to be performed when communication with the domain controller is interrupted and/or otherwise limited.

Masters, George W.↗

Local access control system management using domain information updates

Systems and methods are presented for managing physical access to an access-controlled area using a local access control system. In certain embodiments, information that may be used in access control determinations managed by a remote domain controller may be communicated to a local access control system for use in connection with local access control determinations performed by the access control system independent of the domain controller. In some embodiments, such a configuration may allow for access control determinations to be performed when communication with the domain controller is interrupted and/or otherwise limited.

Masters, George W.↗

Command and Control of Utilities Systems

The utilities systems that encompass the Y-12 National Security Complex are an integral part of the entire campus, and are essential to maintaining critical mission focus for the site. Although the utilities systems each differ in function, the central production and distribution model creates a common thread on which each system is run. Several incidents in FY 2018 and FY 2019 documented a lack of overall systems control and highlighted the need to create a better command system that could maintain system availability and decrease possible impacts to the surrounding environment. An initial system was started in September of 2019 to better control mechanical utility distribution systems. The measurement of the system can be modeled against a standard command and control related incident. The corresponding work hours from a typical control-related incident were used as key component to this system model. System effectiveness is modeled against utility’s incidents that demonstrate a loss of command and control. The increased simulations of the model also document control can only be effectively contained within the stated time (3-5 years) by yielding more engineers to complete alignments, or drastically reducing the amount of time for alignments. The total control points of the model document a clear correlation between alignments, control points, and the amount of man-hours per incident. Current data shows that actual incident man-hours (1.88 manhours/ incident since initial system implementation) are near expected incident man-hours (1.81 manhours/ incident) with command and control for October 2021, which documents a 33.3% reduction in man-hours/incident since initial system implementation. A conclusion can be drawn that focus on increasing the amount of controlled points in the system can reduce incidents and the decrease the amount of non-value added work to employee’s day-to-day lives, while also achieving a culture that enhances and sustains utilities reliability.

99 GENERAL AND MISCELLANEOUS↗

Real time MHD mode control using ECCD in KSTAR: Plan and requirements

For a high-performance, advanced tokamak mode in KSTAR, we have been developing a real-time control system of MHD modes such as sawtooth and Neo-classical Tearing Mode (NTM) by ECH/ECCD. The active feedback control loop will be also added to the mirror position and the real-time detection of the mode position. In this year, for the stabilization of NTM that is crucial to plasma performance we have implemented open-loop ECH antenna control system in KSTAR Plasma Control System (PCS) for ECH mirror movement during a single plasma discharge. KSTAR 170 GHz ECH launcher which was designed and fabricated by collaboration with PPPL and POSTECH has a final mirror of a poloidally and toroidally steerable mirror. The poloidal steering motion is only controlled in the real-time NTM control system and its maximum steering speed is 10 degree/sec by DC motor. However, the latency of the mirror control system and the return period of ECH antenna mirror angle are not fast because the existing launcher mirror control system is based on PLC which is connected to the KSTAR machine network through serial to LAN converter. In this paper, we present the design of real time NTM control system, ECH requirements, and the upgrade plan.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-Layer Predictive Controller for V2G and G2V Services Using on Wireless Power Transfer Technology

This paper presents a comprehensive solution that allows electric vehicles (EV) to autonomously charge and discharge their batteries wirelessly during long term parking and/or the transient stops. A two-layer power-flow controller for bidirectional wireless power transfer system (BWPTS) in EVs applications is proposed. The proposed controller can manage the bidirectional power-flow between EV and surrounding infrastructures such as power grid, home microgrid, building micro-grid, road or another vehicle. It consists of two levels of control; the first is responsible for communicating with the surrounding infrastructures and gathering information from driver, charging station, power grid and battery management system and then, based on these information, it estimates the EV's psychological price as a function of its battery's state-of-charge (SOC) and compares it with the energy price to decide whether to charge, discharge or abstain, and how much the charging or discharging rate. The second layer receives the reference signal from the first one and generates the control parameters for two synchronized resonant converters (one is on the vehicle side and the other is on the grid side) to provide the requited power-flow. The proposed controller is adaptively estimating the system parameters to consider the misalignment conditions effects on the system performance. The parameter estimation is achieved using only one voltage sensor. The second layer control is designed based on a new analytical modeling for the power flow in the system. For verification purposes, a prototype for BWPTS was built and driven by the proposed controller, which was implemented using a field-programmable gate array (FPGA) integrated circuit. The proposed controller provides very fast and stable response during both the transient and steady state operation in comparison with the conventional PI controller.

33 ADVANCED PROPULSION SYSTEMS↗

Notional Examples and Benchmark Aspects of a Resilient Control System

Digital control system technology has pervaded most industries, leading to improvements in the efficiency and reliability of the associated operations. However, the ease of distributing and connecting related control systems for the purposes of increasing performance has resulted in interdependencies that can lead to unexpected conditions. Even with less complex designs, operators and engineers alike are often left with competing goals that are difficult to resolve. A fundamental reason for this dichotomy is that responsibilities lie with different disciplines, and operations are hosted on separate control systems. In addition, with the rising awareness of cyber security and diverse human interactions with control systems, an understanding of human actions from a malicious and benevolent standpoint is necessary. Resilience considers the multiple facets of requirements that drive the performance of control systems in a holistic fashion, whether they are security or stability, stability or efficiency, human interactions or complex interdependencies. As will be shown by example, current research philosophies lack the depth or the focus on the control system application to satisfy these requirements, such as graceful degradation of hierarchical control while under cyber attack. A resilient control system promises to purposefully consider these diverse requirements, developing an adaptive capacity to complex events that can lead to failure of traditional control system designs.

47 OTHER INSTRUMENTATION↗

A Comparative Study of Two Widely Used Grid-Forming Droop Controls on Microgrid Small Signal Stability

Throughout history, two similar grid-forming droop controls are widely reported in literature—the single-and multi-loop droop controls. Although being very similar, the authors find that the dynamic performance and stability characteristics of each control method are very different in a microgrid. Compared with single-loop droop control, the multi-loop droop control is prone to be less damped and loses stability more easily under some circumstances. This paper provides a novel insight into the different dynamic responses of the two basic controls. It points out that the two similar controls adjust the angular frequency and voltage magnitude at different locations within the inverter, resulting in different coupling reactances that impact the dynamic response and stability of microgrids differently. The use of single-loop droop control results in a larger coupling reactance, which helps to improve dynamic response and stability. This novel insight is verified through full-order small signal analysis, offline electromagnetic transient simulation, and real-time hardware-in-the-loop simulation experiments. Results show that the microgrid has a larger small signal stability boundary when using single-loop droop control, and this difference increases as the value of an inverter’s inner filter inductance increases.

42 ENGINEERING↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Decentralized Secondary Frequency Control in Power Systems: Merits and Trade-Offs

Frequency restoration in power systems is conven- tionally performed by broadcasting a centralized signal to local controllers. As a result of the energy transition, technological advances, and the scientific interest in distributed control and optimization methods, a plethora of distributed frequency control strategies have been proposed recently that rely on communication amongst local controllers. In this paper we propose a fully decentralized leaky integral controller for frequency restoration that is derived from a classic lag element. We study steady-state, asymptotic optimality, nominal stability, input-to-state stability, noise rejection, transient performance, and robustness properties of this controller in closed loop with a nonlinear and multivariable power system model. Here, we demonstrate that the leaky integral controller can strike an acceptable trade-off between performance and robustness as well as between asymptotic disturbance rejection and transient convergence rate by tuning its DC gain and time constant. We compare our findings to conventional decentralized integral control and distributed- averaging-based integral control in theory and simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗