Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for {sup 60}Co, {sup 137}Cs, {sup 198}Au, {sup 192}Ir, {sup 169}Yb, {sup 170}Tm, {sup 131}Cs, {sup 125}I, and {sup 103}Pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calculations using HVL or TVL values could overestimate or underestimate the barrier thickness required to achieve a certain reduction in radiation transmission. This questions the use of HVL or TVL indices instead of the actual transmission data. Therefore, a three-parameter model is fitted to results of this work to facilitate accurate and simple radiation shielding calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-268: Change of CT Number During the Course of Chemoradiation Therapy for Pancreatic Cancer

Purpose: It has been observed radiation can induce changes in CT number (CTN) inside tumor during the course of radiation therapy (RT) for several tumor sites including lung and head and neck, suggesting that the CTN change may be potentially used to assess RT response. In this study, we investigate the CTN changes inside tumor during the course of chemoradiation therapy (CRT) for pancreatic cancer. Methods: Daily diagnostic-quality CT data acquired during IGRT for 17 pancreatic head cancer patients using an in-room CT (CTVision, Siemens) were analyzed. All patients were treated with a radiation dose of 50.4 in 1.8 Gy per fraction. On each daily CT set, The contour of the pancreatic head, included in the treatment target, was generated by populating the pancreatic head contour from the planning CT or MRI using an auto-segmentation tool based on deformable registration (ABAS, Elekta) with manual editing if necessary. The CTN at each voxel in the pancreatic head contour was extracted and the 3D distribution of the CTNs was processed using MATLAB. The mean value of CTN distribution was used to quantify the daily CTN change in the pancreatic head. Results: Reduction of CTN in pancreatic head was observed during the CRT delivery in 14 out the 17 (82%) patients studied. Although the average reduction is only 3.5 Houncefield Unit (HU), this change is significant (p<0.01). Among them, there are 7 patients who had a CTN drop larger than 5 HU, ranging from 6.0 to 11.8 HU. In contrast to this trend, CTN was increased in 3 patients. Conclusion: Measurable changes in the CT number in tumor target were observed during the course of chemoradiation therapy for the pancreas cancer patients, indicating this radiation-induced CTN change may be used to assess treatment response.

60 APPLIED LIFE SCIENCES↗

Comparison of Patient Dose in Two-Dimensional Carotid Arteriography and Three-Dimensional Rotational Angiography

Background and Purpose. It is known that interventional neuroradiology (IN) involves high radiation dose to both patients and staff even if performed by trained operators using modern fluoroscopic X-ray equipment and dose-reducing technology. Therefore, every new technology or imaging tool introduced, such as three-dimensional rotational angiography (3D RA), should be evaluated in terms of radiation dose. 3D RA requires a series with a large number of images in comparison with 2D angiography and it is sometimes considered a high-dose IN procedure. The literature is scarce on the 3D RA radiation dose and in particular there are no data on carotid arteriography (CA). The aim of this study was to investigate patient dose differences between 2D and 3D CA. Methods. The study included 35 patients undergoing 2D CA in hospital 1 and 25 patients undergoing 3D CA in hospital 2. Patient technical data collection included information on the kerma area product (KAP), fluoroscopy time (T), total number of series (S), and total number of acquired images (F). Results. Median KAP was 112 Gy cm{sup 2} and 41 Gy cm{sup 2} for hospitals 1 and 2, respectively, median T was 8.2 min and 5.1 min, median S was 13 and 4, and median F was 247 and 242. Entrance surface air-kerma rate, as measured in 'medium' fluoroscopy mode measured in 2D acquisition using a 20 cm phantom of polymethylmethacrylate, was 17.3 mGy/min for hospital 1 and 9.2 mGy/min for hospital 2. Conclusion. 3D CA allows a substantial reduction in patient radiation dose compared with 2D CA, while providing the necessary diagnostic information.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of neural network architectures for data-driven reduced-order modeling

The popularity of deep convolutional autoencoders (CAEs) has engendered new and effective reduced-order models (ROMs) for the simulation of large-scale dynamical systems. Despite this, it is still unknown whether deep CAEs provide superior performance over established linear techniques or other network-based methods in all modeling scenarios. To elucidate this, the effect of autoencoder architecture on its associated ROM is studied through the comparison of deep CAEs against two alternatives: a simple fully connected autoencoder, and a novel graph convolutional autoencoder. Through benchmark experiments, it is shown that the superior autoencoder architecture for a given ROM application is highly dependent on the size of the latent space and the structure of the snapshot data, with the proposed architecture demonstrating benefits on data with irregular connectivity when the latent space is sufficiently large.

42 ENGINEERING↗

Modeling of the oxygen reduction reaction for dense LSM thin films

In this study, the oxygen reduction reaction mechanism is investigated using numerical methods on a dense thin (La 1-x Sr x ) y MnO 3±δ film deposited on a YSZ substrate. This 1-D continuum model consists of defect chemistry and elementary oxygen reduction reaction steps coupled via reaction rates. The defect chemistry model contains eight species including cation vacancies on the A- and B-sites. The oxygen vacancy is calculated by solving species transportation equations in multiphysics simulations. Due to the simple geometry of a dense thin film, the oxygen reduction reaction was reduced to three elementary steps: surface adsorption and dissociation, incorporation on the surface, and charge transfer across the LSM/YSZ interface. The numerical simulations allow for calculation of the temperature- and oxygen partial pressure-dependent properties of LSM. The parameters of the model are calibrated with experimental impedance data for various oxygen partial pressures at different temperatures. The results indicate that surface adsorption and dissociation is the rate-determining step in the ORR of LSM thin films. With the fine-tuned parameters, further quantitative analysis is performed. The activation energy of the oxygen exchange reaction and the dependence of oxygen non-stoichiometry on oxygen partial pressure are also calculated and verified using the literature results.

36 MATERIALS SCIENCE↗

Reduced phase error through optimized control of a superconducting qubit

Minimizing phase and other errors in experimental quantum gates allows higher fidelity quantum processing. To quantify and correct for phase errors, in particular, we have developed an experimental metrology - amplified phase error (APE) pulses - that amplifies and helps identify phase errors in general multilevel qubit architectures. In order to correct for both phase and amplitude errors specific to virtual transitions and leakage outside of the qubit manifold, we implement 'half derivative', an experimental simplification of derivative reduction by adiabatic gate (DRAG) control theory. The phase errors are lowered by about a factor of five using this method to {approx}1.6 deg. per gate, and can be tuned to zero. Leakage outside the qubit manifold, to the qubit |2> state, is also reduced to {approx}10{sup -4} for 20% faster gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Comparison of Lumpectomy Cavity Delineations Between Use of Magnetic Resonance Imaging and Computed Tomography Acquired With Patient in Prone Position for Radiation Therapy Planning of Breast Cancer

Purpose: To compare lumpectomy cavity (LC) and planning target volume (PTV) delineated with the use of magnetic resonance imaging (MRI) and computed tomography (CT) and to examine the possibility of replacing CT with MRI for radiation therapy (RT) planning for breast cancer. Methods and Materials: MRI and CT data were acquired for 15 patients with early-stage breast cancer undergoing lumpectomy during RT simulation in prone positions, the same as their RT treatment positions. The LCs were delineated manually on both CT (LC-CT) and MRI acquired with 4 sequences: T1, T2, STIR, and DCE. Various PTVs were created by expanding a 15-mm margin from the corresponding LCs and from the union of the LCs for the 4 MRI sequences (PTV-MRI). Differences were measured in terms of cavity visualization score (CVS) and dice coefficient (DC). Results: The mean CVSs for T1, T2, STIR, DCE, and CT defined LCs were 3.47, 3.47, 3.87, 3.50. and 2.60, respectively, implying that the LC is mostly visible with a STIR sequence. The mean reductions of LCs from those for CT were 22%, 43%, 36%, and 17% for T1, T2, STIR, and DCE, respectively. In 14 of 15 cases, MRI (union of T1, T2, STIR, and DCE) defined LC included extra regions that would not be visible from CT. The DCs between CT and MRI (union of T1, T2, STIR, and DCE) defined volumes were 0.65 ± 0.20 for LCs and 0.85 ± 0.06 for PTVs. There was no obvious difference between the volumes of PTV-MRI and PTV-CT, and the average PTV-STIR/PTV-CT volume ratio was 0.83 ± 0.23. Conclusions: The use of MRI improves the visibility of LC in comparison with CT. The volumes of LC and PTV generated based on a MRI sequence are substantially smaller than those based on CT, and the PTV-MRI volumes, defined by the union of T1, T2, STIR, and DCE, were comparable with those of PTV-CT for most of the cases studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Life cycle assessment and residue leaching: The importance of parameter, scenario and leaching data selection

Highlights: • Relevance of metal leaching in waste management system LCAs was assessed. • Toxic impacts from leaching could not be disregarded. • Uncertainty of toxicity, due to background activities, determines LCA outcomes. • Parameters such as pH and L/S affect LCA results. • Data modelling consistency and coverage within an LCA are crucial. - Abstract: Residues from industrial processes and waste management systems (WMSs) have been increasingly reutilised, leading to landfilling rate reductions and the optimisation of mineral resource utilisation in society. Life cycle assessment (LCA) is a holistic methodology allowing for the analysis of systems and products and can be applied to waste management systems to identify environmental benefits and critical aspects thereof. From an LCA perspective, residue utilisation provides benefits such as avoiding the production and depletion of primary materials, but it can lead to environmental burdens, due to the potential leaching of toxic substances. In waste LCA studies where residue utilisation is included, leaching has generally been neglected. In this study, municipal solid waste incineration bottom ash (MSWI BA) was used as a case study into three LCA scenarios having different system boundaries. The importance of data quality and parameter selection in the overall LCA results was evaluated, and an innovative method to assess metal transport into the environment was applied, in order to determine emissions to the soil and water compartments for use in an LCA. It was found that toxic impacts as a result of leaching were dominant in systems including only MSWI BA utilisation, while leaching appeared negligible in larger scenarios including the entire waste system. However, leaching could not be disregarded a priori, due to large uncertainties characterising other activities in the scenario (e.g. electricity production). Based on the analysis of relevant parameters relative to leaching, and on general results of the study, recommendations are provided regarding the use of leaching data in LCA studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biological effect of different IMRT delivery techniques: SMLC, DMLC, and helical tomotherapy

Purpose: Intensity-modulated radiotherapy (IMRT) is delivered using a variety of techniques with differing temporal dose characteristics. Spatial dose metrics are generally used to evaluate treatment plan quality. However, the use of this information alone neglects the effects of the significant differences in dose delivery duration and dose accumulation patterns, both of which can impact cell survival. This study uses the linear-quadratic model with dose protraction corrections to evaluate the biological effectiveness of different IMRT delivery techniques, including fixed gantry IMRT in SMLC (step-and-shoot) and DMLC (sliding window) modes and a rotational IMRT technique (helical tomotherapy) for the treatment of prostate and head/neck sites. Methods: The temporal dose pattern was measured using a small volume ion chamber (A1SL--0.057 cm{sup 3}) to calculate the protraction factor, and biological equivalent dose (BED) was calculated for a range of repair half-times and {alpha}/{beta} ratios. The treatment BED is compared to an ideal delivery of the target prescription dose, in which dose is delivered instantaneously (G(t{sub 0})=1), to evaluate loss in biological effectiveness due to protraction in delivery. In the case of a conventional prescription, the loss in biological effectiveness was further evaluated using published tumor control probability (TCP) data. Results: With SMLC and DMLC IMRT delivery, for both prostate and head/neck, the expected additional loss in BED is about 1% compared to 3D CRT, which corresponds to a predicted 2%-3% reduction in TCP. For tomotherapy, the prostate BED loss is smaller in comparison to 3D CRT; hence, the authors expect a TCP increase of the order of 2%-3%. The aforementioned differences are due to the dose accumulation time. Conclusions: While it is theoretically possible to compensate for changes in biologically effective dose, this would be hindered by large uncertainties in parameters used for such calculations; therefore, it is advantageous to irradiate target volume elements as rapidly as possible. The results of this study indicate that temporal dose delivery pattern is an important component in determining the biological effects of IMRT treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficient CP Rounding Using Alternating Least Squares with QR Decomposition

The CANDECOMP/PARAFAC (CP) decomposition is widely used for analyzing multidimensional data, and the alternating least squares (CP-ALS) algorithm is a common method for its computation. CP rounding is the problem of computing a lower-rank CP decomposition of an input already in a higher-rank CP format. While the normal equations (NE) approach in CP-ALS is efficient for the CP rounding problem and frequently used, it becomes unstable in the presence of ill-conditioned subproblems. This paper presents a new QR-based CP-ALS method for CP rounding that preserves both numerical stability and computational efficiency. Here, our experiments show that the proposed method offers significant speedup over a previous QR-based approach and the Tensor Toolbox's NE-based implementation, particularly for higher-order tensors. Furthermore, our approach demonstrates a marked reduction in error for ill-conditioned problems, with error reductions several orders of magnitude smaller compared to the NE-based method, while achieving faster convergence and more accurate solutions. By using a more numerically stable approach, we can solve more problems in reduced working precision, which enables further reduction in time to solution.

CANDECOMP/PARAFAC↗

A Systematic Review and Meta-Analysis of Tai Chi Training in Cardiorespiratory Fitness of Elderly People

Objectives. The purpose of this study was to investigate the influence of Tai Chi on cardiorespiratory fitness (CRF) in elderly people using meta-analysis. Methods. This study used seven electronic databases and data retrieved from randomized controlled trials (RCTs) investigating the role of Tai Chi on CRF in the elderly. All these 24 RCTs were screened and selected from 7 literature databases. The Stata 11.2 software (StataCorp, USA) was used for the meta-analysis, subgroup analysis, and bias test, while the Cochrane Collaboration’s tool was used for the assessment of the risk of bias (RoB). 4 researchers independently participated in sample selection, data extraction, and RoB assessment. Results. Following the inclusion criteria, 24 eligible studies were included in our analysis. The meta-analysis indicated that Tai Chi practice significantly increased the maximum rate of oxygen consumption (VO2 max) (weighted mean difference (WMD) = 3.76, 95% CI: 1.25 to 6.26, P < 0.1 ), leading to an overall reduction in the heart rate (HR) (WMD = −1.84, 95% CI: −2.04 to −1.63, P ≤ 0.001 ) and an increase in the O2 pulse (WMD = 0.94, 95% CI: 0.60 to 1.28, P ≤ 0.001 ) in individuals who practiced Tai Chi regularly compared with those who did not. The subgroup analysis suggested that overall in those who practiced Tai Chi, males (WMD = 1.48, 95% CI: 0.85 to 2.12, P ≤ 0.001 ) had higher O2 pulse than females (WMD = 0.73, 95% CI: 0.33 to 1.12, P ≤ 0.001 ). The subgroup analysis also showed an increase in the vital capacity (VC) (WMD = 316.05, 95% CI: 239.74 to 392.35, P ≤ 0.001 ) in individuals practicing Tai Chi. When the samples were further stratified by Tai Chi practicing time, the subgroup analysis suggested that individuals practicing Tai Chi over a period of 24 weeks showed no significant difference in VC (WMD = 82.95, 95% CI: -98.34 to 264.23, P = 0.370 ), while those practicing Tai Chi over a period of 48 weeks showed a significant increase (WMD = 416.62, 95% CI: 280.68 to 552.56, P ≤ 0.001 ). Furthermore, the subgroup analysis demonstrated that the increase in VC is significantly correlated with the Tai Chi practicing time (WMD = 344.97, 95% CI: 227.88 to 442.06, P ≤ 0.001 ). Conclusion. Regular Tai Chi practice could improve the CRF in the elderly, as indicated by significant improvement in indicators including VO2max, O2pulse, VC, and HR. However, gender and practice time might influence the overall beneficial outcomes.

Tan, Tianyang↗

Energy Saving Melting and Revert Reduction Technology (E-SMARRT): Mechanical Performance of Dies

As a net shape process, die casting is intrinsically efficient and improvements in energy efficiency are strongly dependent on design and process improvements that reduce scrap rates so that more of the total consumed energy goes into acceptable, usable castings. A casting that is distorted and fails to meet specified dimensional requirements is typically remelted but this still results in a decrease in process yield, lost productivity, and increased energy consumption. This work focuses on developing, and expanding the use of, computer modeling methods that can be used to improve the dimensional accuracy of die castings and produce die designs and machine/die setups that reduce rejection rates due to dimensional issues. A major factor contributing to the dimensional inaccuracy of the casting is the elastic deformations of the die cavity caused by the thermo mechanical loads the dies are subjected to during normal operation. Although thermal and die cavity filling simulation are widely used in the industry, structural modeling of the die, particularly for managing part distortion, is not yet widely practiced. This may be due in part to the need to have a thorough understanding of the physical phenomenon involved in die distortion and the mathematical theory employed in the numerical models to efficiently model the die distortion phenomenon. Therefore, two of the goals of this work are to assist in efforts to expand the use of structural modeling and related technologies in the die casting industry by 1) providing a detailed modeling guideline and tutorial for those interested in developing the necessary skills and capability and 2) by developing simple meta-models that capture the results and experience gained from several years of die distortion research and can be used to predict key distortion phenomena of relevance to a die caster with a minimum of background and without the need for simulations. These objectives were met. A detailed modeling tutorial was provided to NADCA for distribution to the industry. Power law based meta-models for predicting machine tie bar loading and for predicting maximum parting surface separation were successfully developed and tested against simulation results for a wide range of machines and experimental data. The models proved to be remarkably accurate, certainly well within the requirements for practical application. In addition to making die structural modeling more accessible, the work advanced the state-of-the-art by developing improved modeling of cavity pressure effects, which is typically modeled as a hydrostatic boundary condition, and performing a systematic analysis of the influence of ejector die design variables on die deflection and parting plane separation. This cavity pressure modeling objective met with less than complete success due to the limits of current finite element based fluid structure interaction analysis methods, but an improved representation of the casting/die interface was accomplished using a combination of solid and shell elements in the finite element model. This approximation enabled good prediction of final part distortion verified with a comprehensive evaluation of the dimensions of test castings produced with a design experiment. An extra deliverable of the experimental work was development of high temperature mechanical properties for the A380 die casting alloy. The ejector side design objective was met and the results were incorporated into the metamodels described above. This new technology was predicted to result in an average energy savings of 2.03 trillion BTU's/year over a 10 year period. Current (2011) annual energy saving estimates over a ten year period, based on commercial introduction in 2009, a market penetration of 70% by 2014 is 4.26 trillion BTU's/year by 2019. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology. The average annual estimate of CO2 reduction per year through 2020 is 0.085 Million Metric Tons of Carbon Equivalent (MM TCE).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Treatment Planning to Improve Delivery Accuracy and Patient Throughput in Helical Tomotherapy

Purpose: To investigate delivery quality assurance (DQA) discrepancies observed for a subset of helical tomotherapy patients. Methods and Materials: Six tomotherapy patient plans were selected for analysis. Three had passing DQA ion chamber (IC) measurements, whereas 3 had measurements deviating from the expected dose by more than 3.0%. All plans used similar parameters, including: 2.5 cm field-width, 15-s gantry period, and pitch values ranging from 0.143 to 0.215. Preliminary analysis suggested discrepancies were associated with plans having predominantly small leaf open times (LOTs). To test this, patients with failing DQA measurements were replanned using an increased pitch of 0.287. New DQA plans were generated and IC measurements performed. Exit fluence data were also collected during DQA delivery for dose reconstruction purposes. Results: Sinogram analysis showed increases in mean LOTs ranging from 29.8% to 83.1% for the increased pitch replans. IC measurements for these plans showed a reduction in dose discrepancies, bringing all measurements within {+-}3.0%. The replans were also more efficient to deliver, resulting in reduced treatment times. Dose reconstruction results were in excellent agreement with IC measurements, illustrating the impact of leaf-timing inaccuracies on plans having predominantly small LOTs. Conclusions: The impact of leaf-timing inaccuracies on plans with small mean LOTs can be considerable. These inaccuracies result from deviations in multileaf collimator latency from the linear approximation used by the treatment planning system and can be important for plans having a 15-s gantry period. The ability to reduce this effect while improving delivery efficiency by increasing the pitch is demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Reproducibility for Thoracic and Upper Gastrointestinal Radiation Therapy: Influence of Immobilization Method and On-Line Cone-Beam CT Guidance

We report the setup reproducibility of thoracic and upper gastrointestinal (UGI) radiotherapy (RT) patients for 2 immobilization methods evaluated through cone-beam computed tomography (CBCT) image guidance, and present planning target volume (PTV) margin calculations made on the basis of these observations. Daily CBCT images from 65 patients immobilized in a chestboard (CB) or evacuated cushion (EC) were registered to the planning CT using automatic bony anatomy registration. The standardized region-of-interest for matching was focused around vertebral bodies adjacent to tumor location. Discrepancies >3 mm between the CBCT and CT datasets were corrected before initiation of RT and verified with a second CBCT to assess residual error (usually taken after 90 s of the initial CBCT). Positional data were analyzed to evaluate the magnitude and frequencies of setup errors before and after correction. The setup distributions were slightly different for the CB (797 scans) and EC (757 scans) methods, and the probability of adjustment at a 3-mm action threshold was not significantly different (p = 0.47). Setup displacements >10 mm in any direction were observed in 10% of CB fractions and 16% of EC fractions (p = 0.0008). Residual error distributions after CBCT guidance were equivalent regardless of immobilization method. Using a published formula, the PTV margins for the CB were L/R, 3.3 mm; S/I, 3.5 mm; and A/P, 4.6 mm), and for EC they were L/R, 3.7 mm; S/I, 3.3 mm; and A/P, 4.6 mm. In the absence of image guidance, the CB slightly outperformed the EC in precision. CBCT allows reduction to a single immobilization system that can be chosen for efficiency, logistics, and cost. Image guidance allows for increased geometric precision and accuracy and supports a corresponding reduction in PTV margin.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing Historical Variability of South Asian Monsoon Lows and Depressions With an Optimized Tracking Algorithm

Abstract Cyclonic low‐pressure systems (LPS) produce abundant rainfall in South Asia, where they are traditionally categorized as monsoon lows, monsoon depressions, and more intense cyclonic storms. The India Meteorological Department (IMD) has tracked monsoon depressions for over a century, finding a large decline in their number in recent decades, but their methods have changed over time and do not include monsoon lows. This study presents a fast, objective algorithm for identifying monsoon LPS and uses it to assess interannual variability and trends in reanalyses. Variables and thresholds used in the algorithm are selected to best match a subjectively analyzed LPS data set while minimizing disagreement between four reanalyses in a training period. The stream function of 850 hPa horizontal wind is found to be optimal in this sense; it is less noisy than vorticity and represents the complete nondivergent wind, even when flow is not geostrophic. Using this algorithm, LPS statistics are computed for five reanalyses, and none show a detectable trend in monsoon depression counts since 1979. Both the Japanese 55‐year Reanalysis (JRA‐55) and the IMD data set show a step‐like reduction in depression counts when they began using geostationary satellite data, in 1979 and 1982, respectively; the 1958–2018 linear trend in JRA‐55, however, is smaller than in the IMD data set, and its error bar includes 0. There are more LPS in seasons with above‐average monsoon rainfall and in La Niña years, but few other large‐scale modes of interannual variability are found to modulate LPS counts, lifetimes, or track length consistently across reanalyses.

54 ENVIRONMENTAL SCIENCES↗

Bacterial genome reduction using the progressive clustering of deletions via yeast sexual cycling

The availability of genetically tractable organisms with simple genomes is critical for the rapid, systems-level understanding of basic biological processes. Mycoplasma bacteria, with the smallest known genomes among free-living cellular organisms, are ideal models for this purpose, but the natural versions of these cells have genome complexities still too great to offer a comprehensive view of a fundamental life form. Here in this paper we describe an efficient method for reducing genomes from these organisms by identifying individually deletable regions using transposon mutagenesis and progressively clustering deleted genomic segments using meiotic recombination between the bacterial genomes harbored in yeast. Mycoplasmal genomes subjected to this process and transplanted into recipient cells yielded two mycoplasma strains. The first simultaneously lacked eight singly deletable regions of the genome, representing a total of 91 genes and ~10%of the original genome. The second strain lacked seven of the eight regions, representing 84 genes. Growth assay data revealed an absence of genetic interactions among the 91 genes under tested conditions. Despite predicted effects of the deletions on sugar metabolism and the proteome, growth rates were unaffected by the gene deletions in the seven-deletion strain. These results support the feasibility of using single-gene disruption data to design and construct viable genomes lacking multiple genes, paving the way toward genome minimization. The progressive clustering method is expected to be effective for the reorganization of any mega-sized DNA molecules cloned in yeast, facilitating the construction of designer genomes in microbes as well as genomic fragments for genetic engineering of higher eukaryotes.

59 BASIC BIOLOGICAL SCIENCES↗

Noise suppression in reconstruction of low-Z target megavoltage cone-beam CT images

Purpose: To improve the image contrast-to-noise (CNR) ratio for low-Z target megavoltage cone-beam CT (MV CBCT) using a statistical projection noise suppression algorithm based on the penalized weighted least-squares (PWLS) criterion. Methods: Projection images of a contrast phantom, a CatPhan{sup Registered-Sign} 600 phantom and a head phantom were acquired by a Varian 2100EX LINAC with a low-Z (Al) target and low energy x-ray beam (2.5 MeV) at a low-dose level and at a high-dose level. The projections were then processed by minimizing the PWLS objective function. The weighted least square (WLS) term models the noise of measured projection and the penalty term enforces the smoothing constraints of the projection image. The variance of projection data was chosen as the weight for the PWLS objective function and it determined the contribution of each measurement. An anisotropic quadratic form penalty that incorporates the gradient information of projection image was used to preserve edges during noise reduction. Low-Z target MV CBCT images were reconstructed by the FDK algorithm after each projection was processed by the PWLS smoothing. Results: Noise in low-Z target MV CBCT images were greatly suppressed after the PWLS projection smoothing, without noticeable sacrifice of the spatial resolution. Depending on the choice of smoothing parameter, the CNR of selected regions of interest in the PWLS processed low-dose low-Z target MV CBCT image can be higher than the corresponding high-dose image.Conclusion: The CNR of low-Z target MV CBCT images was substantially improved by using PWLS projection smoothing. The PWLS projection smoothing algorithm allows the reconstruction of high contrast low-Z target MV CBCT image with a total dose of as low as 2.3 cGy.

60 APPLIED LIFE SCIENCES↗