Search NASA⌕ Search

SEARCH · Search NASA

Results for “Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Tunable Solid‐State Properties and Anisotropic Charge Mobility in Hydrogen‐Bonded Diketopyrrolopyrrole Polymers via Automated Device Fabrication and Characterization

The optoelectronic properties of semiconducting polymers and device performance rely on a delicate interplay of design and processing conditions. However, screening and optimizing the relationships between these parameters for reliably fabricating organic electronics can be an arduous task requiring significant time and resources. To overcome this challenge, Polybot is developed—a robotic platform within a self‐driving lab that can efficiently produce organic field‐effect transistors (OFETs) from various semiconducting polymers via high‐throughput blade coating deposition. Polybot not only handles the fabrication process but also can conduct characterization tests on the devices and autonomously analyze the data gathered, thus facilitating the rapid acquisition of data on a large scale. This work leverages the capabilities of this platform to investigate the fabrication of OFETs using hydrogen bonding‐containing semiconducting polymers. Through high‐throughput fabrication and characterization, various data trends are analyzed, and large extents of anisotropic charge mobility are observed in devices. The materials are thoroughly characterized to understand the role of processing conditions in solid state and electronic properties of these organic semiconductors. The findings demonstrate the effectiveness of automated fabrication and characterization platforms in uncovering novel structure–property relationships, facilitating refinement of rational chemical design, and processing conditions, ultimately leading to new semiconducting materials.

automated fabrication and characterization↗

A Simple Route for Open Fluidic Devices with Particle Walls

Open fluidics, allowing liquid in a flow channel to interact with the external environment, is a revolutionary concept. However, fabricating a highly stable open fluidic device of arbitrary complexity, while maintaining reconfigurability, is still a challenge. This is achieved by the use of a patterned substrate and liquids that are covered with functional, readily available hydrophobic particles, providing great flexibility in the construction and use of open fluidic structures. Decorated with a coating of modified carbon nanotubes (CNTs) to encapsulate the fluids, the study capitalizes on the photothermal characteristics of CNTs to fabricate a device to probe the effects of temperature on tumor chemotherapy. The strategy substantially increases the availability and potential use of open fluidic devices.

Liu, Heng↗

Correlating Electronic Structure and Device Physics with Mixing Region Morphology in High-Efficiency Organic Solar Cells

The donor/acceptor interaction in non-fullerene organic photovoltaics leads to the mixing domain that dictates the morphology and electronic structure of the blended thin film. Initiative effort is paid to understand how these domain properties affect the device performances on high-efficiency PM6:Y6 blends. Different fullerenes acceptors are used to manipulate the feature of mixing domain. It is seen that a tight packing in the mixing region is critical, which could effectively enhance the hole transfer and lead to the enlarged and narrow electron density of state (DOS). As a result, short-circuit current (J SC ) and fill factor (FF) are improved. The distribution of DOS and energy levels strongly influences open-circuit voltage (V OC ). The raised filling state of electron Fermi level is seen to be key in determining device V OC . Energy disorder is found to be a key factor to energy loss, which is highly correlated with the intermolecular distance in the mixing region. A 17.53% efficiency is obtained for optimized ternary devices, which is the highest value for similar systems. The current results indicate that a delicate optimization of the mixing domain property is an effective route to improve the V OC , J SC , and FF simultaneously, which provides new guidelines for morphology control toward high-performance organic solar cells.

36 MATERIALS SCIENCE↗

Volumetric Additive Manufacturing of Dormant Catalytic Chemistries to Generate Silicone Micro‐ and Millifluidic Devices and Instant Molds

Tomographic volumetric additive manufacturing (T‐VAM) rapidly prints solid objects within minutes, accessing photochemistries that are traditionally challenging for layer‐based additive manufacturing methods. This includes high‐viscosity materials, air‐free chemistries, and solid‐state systems. Catalytic chemistries are appealing as a pathway to engineering advanced materials, including tough thermosets, silicone elastomers, and complex block copolymers. However, photoactivated dormant catalytic chemistries, where the catalyst irreversibly activates upon exposure to light, are incompatible with typical tomographic VAM approaches. To address this limitation, a zero‐dose optimization strategy is devised to preserve dormant catalysts in desired regions by keeping them unexposed to light. VAM printed micro‐ and millifluidic devices and instant molds are successfully produced within minutes in silicones polymerized using photoactivated dormant platinum photohydrosilylation catalysts. The printed channels are programmed to be 500 and 2500 µm for the micro‐ and millifluidic devices, and print fidelity is assessed by X‐ray computed tomography. This work demonstrates the potential of zero‐dose optimization to expand the range of chemistries accessible for VAM, enabling the rapid fabrication of complex devices.

Additive Manufacturing↗

Top Stack Optimization for Cu 2 BaSn(S, Se) 4 Photovoltaic Cell Leads to Improved Device Power Conversion Efficiency beyond 6%

Earth-abundant and air-stable Cu 2 BaSnS 4-x Se x (CBTSSe) and related thin-film absorbers are regarded as prospective options to meet the increasing demand for low-cost solar cell deployment. Devices based on vacuum-deposited CBTSSe absorbers have achieved record power conversion efficiency (PCE) of 5.2 % based on a conventional device structure using CdS buffer and i-ZnO/ITO window layers, with open-circuit voltage (V OC ) posing the major bottleneck for improving solar cell performance. The current study demonstrates a >20 % improvement in V OC (from 0.62 V to 0.75 V) and corresponding enhancement in PCE (from 5.1 % to 6.2 % without anti-reflection coating; to 6.5 % with MgF 2 anti-reflection coating) for solution-deposited CBTSSe solar cells. This performance improvement is realized by introducing an alternative successive ionic layer adsorption and reaction (SILAR)-deposited Zn 1-x Cd x S buffer combined with sputtered Zn 1-x Mg x O/Al-doped ZnO window/top contact layer, which offer lower electron affinities relative to the conventional CdS/i-ZnO/ITO stack and better matching with the low electron affinity of CBTSSe. A combined experimental (temperature- and light intensity-dependent V OC measurements) and device simulation (SCAPS-1D) evaluation points to the importance of addressing relative band offsets for both the buffer and window layers relative to the absorber in mitigating interfacial recombination and optimizing CBTSSe solar cell performance.

25 ENERGY STORAGE↗

Toward More Efficient Organic Solar Cells: A Detailed Study of Loss Pathway and Its Impact on Overall Device Performance in Low‐Offset Organic Solar Cells

Abstract Low‐offset organic solar cell systems have attracted great interest since nonfullerene acceptors came into the picture. While numerous studies have focused on the charge generation process in these low‐offset systems, only a few studies have focused on the details of each loss channel in the charge generation process and their impact on the overall device performance. Here, several nonfullerene acceptors are blended with the same polymer donor to form a series of low‐offset organic solar cell systems where significant variation in device performance is observed. Through detailed analyses of loss pathways, it is found that: i) the donor:acceptor interfaces of PM6:Y6 and PM6:TPT10 are close to the optimum energetic condition, ii) energetics at the donor:acceptor interface are the most important factor to the overall device performance, iii) exciton dissociation yield can be field‐dependent owing to the sufficiently small energetic offset at the donor:acceptor interface, and iv) the change in substituents in the terminal group of Y‐series acceptors in this work mainly affects energetics at the donor:acceptor interface instead of the interface density in the active layer. In general, this work presents a path toward more efficient organic solar cells.

14 SOLAR ENERGY↗

Narrowing lab–to–market gaps: Device innovations in fuel generation, solar–cell, and photodetection

Academic translational research efforts to industry are often an underlying sought–after goal among various researchers. Through the interchanges of research endeavors between academia–industry, great innovations can/has been achieved that cater to the real–world application by bridging “industrially relevant” problem solving with pursuing fundamental studies. It is pertinent that most of the studies from university–level research works may not translate into demonstrable market products due to various reasons. Funding support, individual researcher goals, socioeconomic factors, and most importantly the technical know–how of generating revenue strategies for startups, are a few of the factors that have slowed the pace of collaborative efforts. However, we believe that the most crucial component is the identification of the critical parameters that solve long–standing problems that hinder the scale–up of the lab scale research into marketable products considering the techno–economic analysis. Here, to illustrate this, we take the three most relevant examples of devices for fuel generation, devices to utilize solar radiation, and devices for detection and other related applications. In this perspective, we provide an in–depth case study of each of these critical parameters to comment on the direction of research avenues that can serve as step–stones for the commercialization of university–level lab research studies.

42 ENGINEERING↗

Laser machined plastic laminates. Towards portable diagnostic devices for use in low resource environments

Despite significant progress in development of bioanalytical devices cost, complexity, access to reagents and lack of infrastructure have prevented use of these technologies in resource-limited regions. To provide a sustainable tool in the global effort to combat infectious diseases the diagnostic device must be low cost, simple to operate and read, robust, and have sensitivity and specificity comparable to laboratory analysis. Thus, in this mini-review we describe recent work using laser machined plastic laminates to produce diagnostic devices that are capable of a wide variety of bioanalytical measurements and show great promise towards future use in low-resource environments.

47 OTHER INSTRUMENTATION↗

Temperature dependence of nickel ion release from nitinol medical devices

Abstract Nitinol exhibits unique (thermo)mechanical properties that make it central to the design of many medical devices. However, nitinol nominally contains 50 atomic percent nickel, which if released in sufficient quantities, can lead to adverse health effects. While nickel release from nitinol devices is typically characterized using in vitro immersion tests, these evaluations require lengthy time periods. We have explored elevated temperature as a potential method to expedite this testing. Nickel release was characterized in nitinol materials with surface oxide thickness ranging from 12 to 1564 nm at four different temperatures from 310 to 360 K. We found that for three of the materials with relatively thin oxide layers, ≤ 87 nm nickel release exhibited Arrhenius behavior over the entire temperature range with activation energies of 80 to 85 kJ/mol. Conversely, the fourth ''black–oxide'' material, with a much thicker, complex oxide layer, was not well characterized by an Arrhenius relationship. Power law release profiles were observed in all four materials; however, the exponent from the thin oxide materials was approximately 1/4 compared with 3/4 for the black–oxide material. To illustrate the potential benefit of using elevated temperature to abbreviate nickel release testing, we demonstrated that a > 50 day 310 K release profile could be accurately recovered by testing for less than 1 week at 340 K. However, because the materials explored in this study were limited, additional testing and mechanistic insight are needed to establish a protective temperature scaling that can be applied to all nitinol medical device components.

Saylor, David M.↗

Characterization and modeling of reverse-bias breakdown in Cu(In,Ga)Se 2 photovoltaic devices

Partial shading of series-connected thin-film photovoltaic modules can force shaded cells into reverse bias, which can cause rapid and irreversible power loss and reduce the practical module lifespan. Unfortunately, this is a common occurrence in field-deployed modules due to the myriad of environmental factors that can result in partial shading. In this work, we identify as-grown nonuniformities in the Cu(In,Ga)Se 2 (CIGS) absorber layers as the points of origin for the damage induced under reverse-bias conditions. The structure and chemistry associated with inclusions and voids in the CIGS films cause these features to act as resistive heating elements in reverse-bias conditions. This localized resistive heating provides the energy required to induce thermal runaway breakdown in the CIGS devices, resulting in damage to charge collection and reduced active area of a device. This mechanism is also described with a robust device model to connect the experimental observations with their physical origins.

14 SOLAR ENERGY↗

Autonomous Aerosol and Plasma Co‐Jet Printing of Metallic Devices at Ambient Temperature

Abstract Additive manufacturing of metallic materials holds the potential to revolutionize the fabrication of functional devices unattainable via traditional methods. Despite recent advancements, printing metallic materials typically requires thermal processing at elevated temperatures to form dense structures with desired properties, which presents a major challenge for direct printing and integration with temperature‐sensitive materials. Herein, a unique co‐jet printing (CJP) method is reported integrating an aerosol jet and a non‐thermal, atmospheric pressure plasma jet to enable concurrent aerosol deposition of metal nanoparticle inks and in situ sintering at ambient temperature. A machine learning algorithm is integrated with the CJP to perform real‐time defect detection and autonomous correction, enhancing the yield of printed films with high electrical conductivity from 44% to 94%. Concurrent printing and sintering eliminate the need for post‐printing processing, reducing the overall manufacturing time by multiple folds depending on product size. CJP enables direct printing of functional devices on a variety of temperature‐sensitive materials including biological materials. Direct printing of hydration sensors on living plant leaves is demonstrated for long‐duration monitoring of hydration level in the plant. The versatile CJP method opens tremendous opportunities to harmoniously integrate abiotic and biotic materials for emerging applications in wearable/implantable devices and biohybrid systems.

Du, Yipu [Department of Aerospace and Mechanical E↗

Femoral Artery Stenosis Following Percutaneous Closure Using a Starclose Closure Device

Starclose (Abbott Vascular Devices, Redwood City, CA) is a new arterial closure device that seals a femoral puncture site with an extravascular star-shaped nitinol clip. The clip projects small tines into the arterial wall which fold inward, causing the arterial wall to pucker, producing a purse-string-like seal closing the puncture site. The case history is that of a 76-year-old female patient who underwent day-case percutaneous diagnostic coronary angiography. A Starclose femoral artery closure device was used to achieve hemostasis with subsequent femoral artery stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Mechanical Thrombectomy Device for Retrieval of Intravascular Thrombus

Purpose: Thrombotic and embolic vascular occlusion represents a leading cause of morbidity and mortality. Currently available thrombectomy devices have limitations, including difficulty removing organized thrombus and clot fragmentation with distal embolization. A novel mechanical thrombectomy device (MTD), designed to remove both hard and soft thrombus without trauma to the blood vessel, was tested in preclinical porcine models evaluating efficacy, safety, and ease of use. Materials and Methods: A total of 26 vessels in 14 pigs underwent mechanical thrombectomy with MTD. Thrombectomy was performed in nine superficial femoral arteries, eight subclavian arteries, five primary branches of the subclavian artery, lateral thoracic artery or the thyrocervical trunk, and four external carotids. Subacute organized fibrin-laden thrombus was injected into the arteries producing vascular occlusion. The MTD was then used for thrombectomy to restore patency and blood flow. Results: Intact thrombus was retrieved from 24 of 26 of the vessels with a single pass of the MTD, resulting in complete restoration of patency in 21 vessels and partial patency in 4 vessels. In 8 cases that used an early design, the embolic material fragmented during withdrawal from the access sheath. In 4 procedures that used an early design, the MTD failed to deploy fully and the embolus was not completely captured. No intraprocedural complications or vascular damage occurred. Conclusions: The present pilot studies demonstrate basic safety and efficacy of a novel MTD with design attributes suitable for retrieval of intact acute and organized chronic thrombus. The device has potential intracranial and peripheral utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Device for True Lumen Re-Entry After Subintimal Recanalization of Superficial Femoral Arteries: First-in-Man Experience and Technical Description

Subintimal angioplasty (SAP) is frequently performed for the treatment of critical limb ischemia (CLI) and has been recognized as an effective technique for these patients. Nevertheless, this approach is limited by the lack of controlled re-entry into the true lumen of the target vessel. We describe a novel device for true lumen re-entry after subintimal recanalization of superficial femoral arteries (SFA). We report our experience with six patients treated between April 2009 and January 2010 with a novel system designed to facilitate true lumen re-entry. The device was advanced by ipsilateral antegrade approach through a 6-French sheath. Successful reaccess into the true lumen was obtained in five of six patients without complications. The patient in whom the reaccess to the true lumen was not possible underwent successful bypass surgery. At 30 days follow-up, the SFA was patent in all patients according to echo-Doppler examination. Our preliminary experience indicates that this novel re-entry device increases the success rate of percutaneous revascularization of chronically occluded SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗