Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Forward Intensity-Modulated Radiotherapy Planning in Breast Cancer to Improve Dose Homogeneity: Feasibility of Class Solutions

Purpose: To explore forward planning methods for breast cancer treatment to obtain homogeneous dose distributions (using International Commission on Radiation Units and Measurements criteria) within normal tissue constraints and to determine the feasibility of class solutions. Methods and Materials: Treatment plans were optimized in a stepwise procedure for 60 patients referred for postlumpectomy irradiation using strict dose constraints: planning target volume (PTV){sub 95%} of >99%; V{sub 107%} of <1.8 cc; heart V{sub 5Gy} of <10% and V{sub 10Gy} of <5%; and mean lung dose of <7 Gy. Treatment planning started with classic tangential beams. Optimization was done by adding a maximum of four segments before adding beams, in a second step. A breath-hold technique was used for heart sparing if necessary. Results: Dose constraints were met for all 60 patients. The classic tangential beam setup was not sufficient for any of the patients; in one-third of patients, additional segments were required (<3), and in two-thirds of patients, additional beams (<2) were required. Logistic regression analyses revealed central breast diameter (CD) and central lung distance as independent predictors for transition from additional segments to additional beams, with a CD cut-off point at 23.6 cm. Conclusions: Treatment plans fulfilling strict dose homogeneity criteria and normal tissue constraints could be obtained for all patients by stepwise dose intensity modification using limited numbers of segments and additional beams. In patients with a CD of >23.6 cm, additional beams were always required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are larger and more common in volumes with high microsphere concentrations and indicate that the spatial distribution of the artery tree must be considered in estimates of microsphere distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-16A-07: Sculpting Isodose Lines: Design of An Internally Shielded Tandem for Cervical Cancer Brachytherapy

Purpose: With the prescription method moving from point A to 3D volume based in cervical cancer HDR brachytherapy, the traditional pear-shaped isodose lines are desired to be sculptured to conform to the irregular shaped target. The standard single channel tandem cannot generate asymmetric isodose lines. Most of the directionally shielded sources proposed in literature are challenging to manufacture and operate. In this study, we proposed a novel internally shielded tandem applicator design which gave users more freedom to manipulate isodose lines while planning. Methods: The proposed tandem design has one centrally located lead cylindrical rod of 8 mm in diameter serving as the internal shield. Multiple source channels with the diameter of 2 mm are evenly spaced and engraved on the central cylindrical rod. The overall diameter of the tandem with polymer encapsulation was kept to be 10 mm. Various number of channels and engraving depths have been tested in the design process. Geant4 Monte Carlo toolkit was used for dose calculation assuming a Varian VS2000 source was placed inside the applicator. A Monte Carlo based planning system has been developed in-house to generate brachytherapy plans. Test plans by using this internally shielded tandem were generated for 3 clinical cases. Results: Water phantom results shown the dose distribution from a VS2000 source in the tandem was strongly distorted towards one direction due to the presence of shielding material. Conformal plans with asymmetric isodose distributions around the tandem can be generated by optimizing dwell times in different channels. Conclusion: An effective and easy-to-use internally shielded tandem was developed. It gave user the freedom to sculpt isodose lines to generate conformal plans for cervical cancer brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Robust Design Under Uncertainty in Quantum Error Mitigation

Error mitigation techniques are crucial to achieving near-term quantum advantage. Classical postprocessing of quantum computation outcomes is a popular approach for error mitigation, which includes methods, such as zero noise extrapolation, virtual distillation, and learning-based error mitigation. However, these techniques have limitations due to the propagation of uncertainty resulting from the finite shot number of a quantum measurement. In this work, we introduce general and unbiased methods for quantifying the uncertainty and error of error-mitigated observables based on the strategic sampling of error mitigation outcomes. We then extend our approach to demonstrate the optimization of performance and robustness of error mitigation under uncertainty. To illustrate our methods, we apply them to zero noise extrapolation and Clifford date regression in the ground state of the XY model simulated using depolarizing and International Business Machines Corporation (IBM) Toronto noise models, respectively. In particular, we optimize the choice of noise levels and the allocation of shots for zero noise extrapolation and the distribution of the training circuits for Clifford data regression. While our methods are readily applicable to any postprocessing-based error mitigation approach, in practice they must not be prohibitively expensive—even though they perform optimizations of the error mitigation hyperparameters requiring sampling of a statistical distribution of error mitigation outcomes. By leveraging surrogate-based optimization, we show that our methods can efficiently perform optimal design for a zero noise extrapolation implementation. We then further demonstrate the transferability of learned zero noise extrapolation hyperparameters to other similar circuits.

97 MATHEMATICS AND COMPUTING↗

Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations

Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientations were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of a laminar electron flow for 300 GHz high-power pulsed gyrotron

This paper describes the design of a triode magnetron injection gun for use in a 200 kW, 300 GHz gyrotron. As power and frequency increase, the performance of the gyrotron becomes quite sensitive to the quality of the electron beam. Formation of a laminar electron flow is essential for the realization of a high quality beam with a small velocity spread. In this study, a new method is developed for a quantitative evaluation of the laminarity and is applied to optimize the electrode design. The laminarity depends not only on conventional design parameters such as the cathode slant angle but also on the spatial distribution of the electric field along the beam trajectory. In the optimized design, the velocity pitch factors, {alpha}, larger than 1.2 are obtained at 65 kV, 10 A with spreads, {Delta}{alpha}, less than 5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robustness of spin-coupling distributions for perfect quantum state transfer

The transmission of quantum information between different parts of a quantum computer is of fundamental importance. Spin chains have been proposed as quantum channels for transferring information. Different configurations for the spin couplings were proposed in order to optimize the transfer. As imperfections in the creation of these specific spin-coupling distributions can never be completely avoided, it is important to find out which systems are optimally suited for information transfer by assessing their robustness against imperfections or disturbances. We analyze different spin coupling distributions of spin chain channels designed for perfect quantum state transfer. In particular, we study the transfer of an initial state from one end of the chain to the other end. We quantify the robustness of different coupling distributions against perturbations and we relate it to the properties of the energy eigenstates and eigenvalues. We find that the localization properties of the systems play an important role for robust quantum state transfer.

36 MATERIALS SCIENCE↗

Total skin electron therapy (TSET): A reimplementation using radiochromic films and IAEA TRS-398 code of practice

Purpose: The aim of this work is to present an updated implementation of total skin electron therapy (TSET) using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films. The optimization of quality control tests is also included. Methods: A Varian 2100 C/D linear accelerator equipped with the special procedure HDTSe{sup -} (high dose rate total skin electron mode, E=6 MeV) was employed to perform TSET irradiations using the modified Stanford technique. The commissioning was performed following the AAPM report 23 recommendations. In particular, for dual-field beams irradiation, the optimal tilt angle was investigated and the dose distribution in the treatment plane was measured. For a complete six dual-field beams irradiation, the treatment skin dose on the surface of a cylindrical phantom was evaluated by radiochromic films and the B factor which relates the single dual-field skin dose to the six dual-field skin dose was assessed. Since the TRS-398 reference conditions do not meet the requirements of TSET absolute dosimetry, GafChromic EBT films were also employed to check and validate the application of the protocol. Simplified procedures were studied to verify beam constancy in PMMA phantoms without the more difficult setup of total skin irradiation. Results: The optimized geometrical setup for dual-field beams was: Tilt angle={+-}19 deg., SSD=353 cm, and the beam degrader (200x100x1 cm{sup 3}) placed at 320 cm from the source. As regards to dose homogeneity in the treatment plane, for dual-field beams irradiation, the mean relative dose value was 97%{+-}5% (normalizing to 100% at the calibration point level). For six dual-field beams irradiation, the multiplication factor B was 2.63. In addition, beam quality, dose rate, and bremsstrahlung contribution were also suitable for TSET treatments. The TRS-398 code of practice was used for TSET dosimetry, as dose measurements performed by ionization chamber and radiochromic film agreed within 2.5%. Simplified quality control tests and baseline values were presented in order to check flatness, symmetry, and field size with radiochromic films and output and beam quality constancy with ionization chamber. Short-term reproducibility and MU linearity tests were also included. Conclusions: Commissioning parameters met the requirements of TSET treatments and the matching of AAPM guidelines with the IAEA code of practice was successful. Frequent beam performance controls can be easily performed through the presented quality assurance tests. Radiochromic dosimetry facilitated the TSET commissioning and played a major role to validate the application of TRS-398.

60 APPLIED LIFE SCIENCES↗

Large deviations of the current in a two-dimensional diffusive system

In this notes we study the large deviations of the time-averaged current in the two-dimensional (2D) Kipnis-Marchioro-Presutti model of energy transport when subject to a boundary gradient. We use the tools of hydrodynamic fluctuation theory, supplemented with an appropriate generalization of the additivity principle. As compared to its one-dimensional counterpart, which amounts to assume that the optimal profiles responsible of a given current fluctuation are time-independent, the 2D additivity conjecture requires an extra assumption, i.e. that the optimal, divergence-free current vector field associated to a given fluctuation of the time-averaged current is in fact constant across the system. Within this context we show that the current distribution exhibits in general non-Gaussian tails. The ensuing optimal density profile can be either monotone for small current fluctuations, or non-monotone with a single maximum for large enough current deviations. Furthermore, this optimal profile remains invariant under arbitrary rotations of the current vector, providing a detailed example of the recently introduced Isometric Fluctuation Relation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A scoping study of far-SOL main-wall protection limiters for steady-state operation of compact pilot plant tokamaks

We present a novel method for handling steady-state heat fluxes incident on the main wall of pilot plant-scale magnetic fusion devices, based on the utilization of protection limiters in the far scrape-off layer (SOL). This method helps avoid large plasma-wall gaps, without excessively compromising blanket performance. We present an optimization algorithm for determining the appropriate size and scale of these protection limiters given (1) probability distributions of SOL plasma parameters and (2) assumed risk tolerance. As part of this optimization, we have developed an analytic description of parallel heat fluxes across limiter shadows, and an objective cost function (the ‘Far-SOL Marginal Cost’) to quantify the impact that different main-wall thermal management design choices have on reactor capital cost. Applying the model to a midscale fusion pilot plant concept shows that making use of far-SOL protection limiters can reduce capital costs on the order of $500 M, relative to naively increasing the plasma-wall gap. Our analysis demonstrates that the far-SOL power decay length is the highest-leverage plasma assumption for thermal loading of the first wall, and the primary cost driver for main wall thermal management. The relative cost efficiency of protection limiters increases as assumptions on the far-SOL heat flux become more pessimistic. The concepts described in this paper motivate the further development of far-SOL protection limiters as part of larger efforts to design economical core-edge-wall compatible solutions for a fusion pilot plant.

Design under uncertainty↗

Low-cost wireless voltage & current grid monitoring

This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

14 SOLAR ENERGY↗

Statistical Multiobjective Optimization of Thiospinel CoNi 2 S 4 Nanocrystal Synthesis via Design of Experiments

Thiospinels, such as CoNi 2 S 4 , are showing promise for numerous applications, including as catalysts for the hydrogen evolution reaction, hydrodesulfurization, and oxygen evolution and reduction reactions; however, CoNi 2 S 4 has not been synthesized as small, colloidal nanocrystals with high surface-area-to-volume ratios. Traditional optimization methods to control nanocrystal attributes such as size typically rely upon one variable at a time (OVAT) methods that are not only time and labor intensive but also lack the ability to identify higher-order interactions between experimental variables that affect target outcomes. Herein, we demonstrate that a statistical design of experiments (DoE) approach can optimize the synthesis of CoNi 2 S 4 nanocrystals, allowing for control over the responses of nanocrystal size, size distribution, and isolated yield. After implementing a 2 5–2 fractional factorial design, the statistical screening of five different experimental variables identified temperature, Co:Ni precursor ratio, Co:thiol ratio, and their higher-order interactions as the most critical factors in influencing the aforementioned responses. Second-order design with a Doehlert matrix yielded polynomial functions used to predict the reaction parameters needed to individually optimize all three responses. A multiobjective optimization, allowing for the simultaneous optimization of size, size distribution, and isolated yield, predicted the synthetic conditions needed to achieve a minimum nanocrystal size of 6.1 nm, a minimum polydispersity (σ/$\bar{d}$) of 10%, and a maximum isolated yield of 99%, with a desirability of 96%. The resulting model was experimentally verified by performing reactions under the specified conditions. Furthermore, our work illustrates the advantage of multivariate experimental design as a powerful tool for accelerating control and optimization in nanocrystal syntheses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-786: Utility of Gold Wires to Optimize Intensity Modulation Capacity of a Novel Directional Modulated Brachytherapy Tandem Applicator for Image Guided Cervical Cancer Brachytherapy

Purpose: To evaluate the impact of using gold wires to differentially fill various channels on plan quality compared with conventional T&R applicator, inside a novel directional modulated brachytherapy (DMBT) tandem applicator for cervical cancer brachytherapy. Materials and Methods: The novel DMBT tandem applicator has a 5.4-mm diameter MR-compatible tungsten alloy enclosed in a 0.3-mm thick plastic tubing that wraps around the tandem. To modulate the radiation intensity, 6 symmetric peripheral holes of 1.3-mm diameter are grooved along the tungsten alloy rod. These grooved holes are differentially filled with gold wires to generate various degrees of directional beams. For example, three different fill patterns of 1) all void, 2) all filled except the hole containing the 192-Ir source, and 3) two adjacent holes to the 192-Ir source filled were Monte Carlo simulated. The resulting 3D dose distributions were imported into an in-house-coded inverse optimization planning system to generate HDR brachytherapy clinical plans for 19 patient cases. All plans generated were normalized to the same D90 as the clinical plans and D2cc doses of OARs were evaluated. Prescription ranged between 15 and 17.5Gy. Results: In general, the plans in case 1) resulted in the highest D2cc doses for the OARs with 11.65±2.30Gy, 7.47±3.05Gy, and 9.84±2.48Gy for bladder, rectum, and sigmoid, respectively, although the differences were small. For the case 2), D2cc doses were 11.61±2.29Gy, 7.41±3.07Gy, and 9.75±2.45Gy, respectively. And, for the case 3), D2cc doses were 11.60±2.28Gy, 7.41±3.05Gy, and 9.74±2.45Gy, respectively. Difference between 1) and 2) cases were small with the average D2cc difference of <0.64%. Difference between 1) and 3) cases were even smaller with the average D2cc difference of <0.1%. Conclusions: There is a minimal clinical benefit by differentially filling grooved holes in the novel DMBT tandem applicator for image guided cervical cancer brachytherapy.

60 APPLIED LIFE SCIENCES↗

Synthesis of MSnO{sub 3} (M = Ba, Sr) nanoparticles by reverse micelle method and particle size distribution analysis by whole powder pattern modeling

Highlights: ► BaSnO{sub 3} and SrSnO{sub 3} nanoparticles synthesized using the reverse micelle method. ► Particle size and size distribution studied by whole powder pattern modeling. ► Nanoparticles are of optimal size for investigation in dye-sensitized solar cells. -- Abstract: Light-to-electricity conversion efficiency in dye-sensitized solar cells critically depends not only on the dye molecule, semiconducting material and redox shuttle selection but also on the particle size and particle size distribution of the semiconducting photoanode. In this study, nanocrystalline BaSnO{sub 3} and SrSnO{sub 3} particles have been synthesized using the microemulsion method. Particle size distribution was studied by whole powder pattern modeling which confirmed narrow particle size distribution with an average size of 18.4 ± 8.3 nm for SrSnO{sub 3} and 15.8 ± 4.2 nm for BaSnO{sub 3}. These values are in close agreement with results of transmission electron microscopy. The prepared materials have optimal microstructure for successive investigation in dye-sensitized solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective robust optimization: A new intensity-modulated proton therapy optimization strategy

Purpose: To develop a new robust optimization strategy for intensity-modulated proton therapy as an important step in translating robust proton treatment planning from research to clinical applications. Methods: In selective robust optimization, a worst-case-based robust optimization algorithm is extended, and terms of the objective function are selectively computed from either the worst-case dose or the nominal dose. Two lung cancer cases and one head and neck cancer case were used to demonstrate the practical significance of the proposed robust planning strategy. The lung cancer cases had minimal tumor motion less than 5 mm, and, for the demonstration of the methodology, are assumed to be static. Results: Selective robust optimization achieved robust clinical target volume (CTV) coverage and at the same time increased nominal planning target volume coverage to 95.8%, compared to the 84.6% coverage achieved with CTV-based robust optimization in one of the lung cases. In the other lung case, the maximum dose in selective robust optimization was lowered from a dose of 131.3% in the CTV-based robust optimization to 113.6%. Selective robust optimization provided robust CTV coverage in the head and neck case, and at the same time improved controls over isodose distribution so that clinical requirements may be readily met. Conclusions: Selective robust optimization may provide the flexibility and capability necessary for meeting various clinical requirements in addition to achieving the required plan robustness in practical proton treatment planning settings.

60 APPLIED LIFE SCIENCES↗

Atomic-Scale Imaging of Lithium Vacancies in a Battery Cathode by Multislice Electron Ptychography

Atomic-resolution imaging of battery materials is critical for identification of local defects and structural variations, which are tied to battery performance. However, since battery materials are, by design, optimized to allow ion motion in response to an applied electric field, they are also very sensitive to radiation damage by an electron beam. Image resolution is therefore severely constrained by the dose applied. Here, we show that multislice electron ptychography (MEP) can provide sub-ångström lateral resolution images of both light and heavy elements of a Li-ion battery cathode, along with nanometer-scale depth information and greater dose efficiency than conventional electron microscopy methods. Using the depth-sectioning capability of MEP, we have been able to obtain direct visualizations of Li vacancy clusters, atom column by atom column, in Li x Ni 0.33 Mn 0.33 Co 0.33 O 2 (NMC111) cathodes. This capability to track Li distributions will be valuable in understanding, informing, and optimizing electrode material design for ion storage and transfer.

batteries↗

Developing Renewable Energy Applications for Water Treatment Technologies and Transmission

The need for smaller treatment facilities for more isolated or rural municipal entities and industrial water treatment facilities continues to grow. From environmental justice and energy needs in remote communities that have never been serviced by larger scale utilities to smaller onsite treatment requirements to meet discharge regulations, energy efficient treatment systems that can leverage renewable energy sources can be an important asset to owners. Climate change and population dynamics have changed the needs for distributed water treatment systems and the manner in which they function. New treatment technologies that can operate under dynamic conditions and leverage variable energy sources (e.g., renewable energy, RE) can provide substantial efficiencies and cost savings. The National Renewable Energy Laboratory (NREL) is embarking on research projects that will perform multi-scale studies to investigate treatment technologies on varying source water quality that can operate under unsteady state flow conditions (timing) in response to energy availability, supply, and demand. A pilot-scale system will be built to assess modularity and scaling of treatment system operating conditions and performance. Modeling will also be used to determine feasibility and integration into grid emulation platforms to understand the use and value of operation with RE. Optimization will be completed for the treatment and distribution systems to document strengths and weaknesses of using RE power sources. Results of this effort will advance dynamic water treatment understanding under variable conditions and integration of RE sources to power these systems. This will lead to further decarbonization of municipal and private treatment facilities while supporting a paradigm shift in water treatment process operation and system design to achieve net-zero goals and move toward energy-sensitive resilient water treatment systems.

ENERGY PLANNING, POLICY, AND ECONOMY↗