Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

QCD corrections to top quark pair production in association with a photon at hadron colliders

We compute QCD corrections to the production of a tt pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross section. We study next-to-leading-order QCD corrections to the pp{yields}tt{gamma} process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp{yields}tt{gamma} process on the measurement of the top quark electric charge at the 14 TeV LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Probabilistic Radar Forward Model for Branched Planar Ice Crystals

Polarimetric radar measurements provide information about ice particle growth and offer the potential to evaluate and better constrain ice microphysical models. To achieve these goals, one must map the ice particle physical properties (e.g., those predicted by a microphysical model) to electromagnetic scattering properties using a radar forward model. Simplified methods of calculating these scattering properties using homogeneous, reduced-density spheroids produce large errors in the polarimetric radar measurements, particularly for low-aspect-ratio branched planar crystals. To overcome these errors, an empirical method is introduced to more faithfully represent branched planar crystal scattering using scattering calculations for a large number of detailed shapes. Additionally, estimates of the uncertainty in the scattering properties, owing to ambiguity in the crystal shape given a set of bulk physical properties, are also incorporated in the forward model. To demonstrate the utility of the forward model developed herein, the radar variables are simulated from microphysical model output for an Arctic cloud case. The simulated radar variables from the empirical forward model are more consistent with the observations compared to those from the homogeneous, reduced-density-spheroid model, and have relatively low uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamical Control of Broadband Coherent Absorption in ENZ Films

Interferometric effects between two counter-propagating beams incident on an optical system can lead to a coherent modulation of the absorption of the total electromagnetic radiation with 100% efficiency even in deeply subwavelength structures. Coherent perfect absorption (CPA) rises from a resonant solution of the scattering matrix and often requires engineered optical properties. For instance, thin film CPA benefits from complex nanostructures with suitable resonance, albeit at a loss of operational bandwidth. In this work, we theoretically and experimentally demonstrate a broadband CPA based on light-with-light modulation in epsilon-near-zero (ENZ) subwavelength films. We show that unpatterned ENZ films with different thicknesses exhibit broadband CPA with a near-unity maximum value located at the ENZ wavelength. By using Kerr optical nonlinearities, we dynamically tune the visibility and peak wavelength of the total energy modulation. Our results based on homogeneous thick ENZ media open a route towards on-chip devices that require efficient light absorption and dynamical tunability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision Measurement of the Neutron Magnetic Form Factor via the Ratio Method at Jefferson Lab Hall A

Protons and neutrons, collectively known as nucleons, are composed of quarks and gluons. The Sachs electromagnetic form factors encode information about the spatial distributions of charge and magnetization in the nucleon, particularly at low momentum transfer. In particular, the neutron magnetic form factor (GMn) provides crucial information about the distribution of magnetization inside the neutron and helps constrain theoretical models of nucleon structure. Quasi-elastic electron scattering from deuterium was measured up to Q^2=13.5 GeV^2 using the Super BigBite Spectrometer in Hall A at Jefferson Lab. In this work, the neutron magnetic form factor GMn was extracted at Q^2 = 3.0 GeV^2 and Q^2=4.5 GeV^2 using the Ratio Method. These results represent a subset of the full dataset collected in this experiment, which extended to significantly higher Q^2. The extracted GMn values agree with the existing global fit within approximately two standard deviations at Q^2=3.0 and show excellent agreement at Q^2=4.5. The measurements achieved systematic uncertainties of about 2% and statistical uncertainties below 0.5%, among the most precise determinations of GMn at these kinematics. These results demonstrate the robustness of the experimental technique and provide an important validation point for future extractions at higher Q^2, where data remain scarce. In addition, the GRINCH heavy gas Cherenkov detector—a key component of the experimental apparatus—was commissioned and achieved an electron detection efficiency of approximately 97%, supporting reliable particle identification. Together, the analysis presented here advances both our understanding of nucleon structure and the validation of the experimental methods and instrumentation used to access it.

Satnik, Maria [College of William and Mary, Willia↗

Electron flow stability in magnetically insulated vacuum transmission lines

We evaluate the stability of electron current flow in high-power magnetically insulated transmission lines (MITLs). A detailed model of electron flow in cross-field gaps yields a dispersion relation for electromagnetic (EM) transverse magnetic waves [R. C. Davidson et al., Phys. Fluids 27, 2332 (1984)] which is solved numerically to obtain growth rates for unstable modes in various sheath profiles. These results are compared with two-dimensional (2D) EM particle-in-cell (PIC) simulations of electron flow in high-power MITLs. We find that the macroscopic properties (charge and current densities and self-fields) of the equilibrium profiles observed in the simulations are well represented by the laminar-flow model of Davidson et al. Idealized simulations of sheared flow in electron sheaths yield growth rates for both long (diocotron) and short (magnetron) wavelength instabilities that are in good agreement with the dispersion analysis. We conclude that electron sheaths that evolve self-consistently from space-charged-limited emission of electrons from the cathode in well-resolved 2D EM PIC simulations form stable profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic signature of supermassive black hole binaries that enter their gravitational-wave induced inspiral

Mergers of gas-rich galaxies lead to black hole binaries that coalesce as a result of dynamical friction on the ambient gas. Once the binary tightens to < or approx. 10{sup 3} Schwarzschild radii, its merger is driven by the emission of gravitational waves (GWs). We show that this transition occurs generically at orbital periods of {approx}1-10 years and an orbital velocity v of a few thousand km s{sup -1}, with a very weak dependence on the supply rate of gas (v{proportional_to}M{sup 1/8}). Therefore, as binaries enter their GW-dominated inspiral, they inevitably induce large periodic shifts in the broad emission lines of any associated quasar(s). The probability of finding a binary in tighter configurations scales as v{sup -8} owing to their much shorter lifetimes. Narrow-band monitoring of the broad emission lines of quasars on time scales of months to decades can set a lower limit on the expected rate of GW sources for the Laser Interferometer Space Antenna.

79 ASTRONOMY AND ASTROPHYSICS↗

An X-band waveguide measurement technique for the accurate characterization of materials with low dielectric loss permittivity

In this work, we present a new X-band waveguide (WR90) measurement method that permits the broadband characterization of the complex permittivity for low dielectric loss tangent material specimens with improved accuracy. An electrically long polypropylene specimen that partially fills the cross-section is inserted into the waveguide and the transmitted scattering parameter (S{sub 21}) is measured. The extraction method relies on computational electromagnetic simulations, coupled with a genetic algorithm, to match the experimental S{sub 21} measurement. The sensitivity of the technique to sample length was explored by simulating specimen lengths from 2.54 to 15.24 cm, in 2.54 cm increments. Analysis of our simulated data predicts the technique will have the sensitivity to measure loss tangent values on the order of 10{sup −3} for materials such as polymers with relatively low real permittivity values. The ability to accurately characterize low-loss dielectric material specimens of polypropylene is demonstrated experimentally. The method was validated by excellent agreement with a free-space focused-beam system measurement of a polypropylene sheet. This technique provides the material measurement community with the ability to accurately extract material properties of low-loss material specimen over the entire X-band range. This technique could easily be extended to other frequency bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Components Qualification for a Possible use in the Mu2e Calorimeter Waveform Digitizer

The Mu2e experiment at Fermilab searches for the charged flavor violating conversion of a muon into an electron in the Coulomb field of a nucleus. The detector consists of a straw tube tracker and a CSI crystal electromagnetic calorimeter, both housed in a superconducting solenoid. Both the front-end and the digital electronics, located inside the cryostat, will be operated in vacuum under a 1 T magnetic field, having to sustain the high flux of neutrons and ionizing particles coming from the muons stopping target. These harsh experimental conditions make the design of the calorimeter waveform digitizer quite challenging. All the selected commercial devices must be tested individually and qualified for radiation hardness and operation in high magnetic field. At the moment the expected particles flux and spectra at the digitizers location are not completely simulated and we are using initial rough estimates to select the components for the first prototype. We are gaining experience in the qualification procedures using the selected components but the choice will be frozen only when dose and neutron flux simulations will be completed. The experimental results of the first qualification campaign are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton deflectometry with in situ x-ray reference for absolute measurement of electromagnetic fields in high-energy-density plasmas

In this work, we report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D 3 He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.

47 OTHER INSTRUMENTATION↗

Time-Lapse Electromagnetic Methods for Monitoring Plume Development in a Carbon Storage Reservoir

Conference presentation at International Meeting for Applied Geoscience & Energy (IMAGE), Houston, Texas, August 25–28, 2025. The Energy & Environmental Research Center (EERC) is leading applied research on electromagnetic (EM) monitoring methods at an active carbon storage site in North Dakota. Injection operations at the site began in February 2024, with a permitted injection rate of up to 2.7 million tonnes of CO 2 annually using six injection wells. CO 2 is captured on-site and injected into the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer located at a depth of approximately 1800 meters. The EERC led acquisition of multiple active- and passive-source EM techniques between August and October of 2024 to provide a thorough understanding of the resistivity profile at the site.

02 PETROLEUM↗

NEAR-INFRARED LINEAR POLARIZATION OF ULTRACOOL DWARFS

We report on near-infrared J- and H-band linear polarimetric photometry of eight ultracool dwarfs (two late-M, five L0-L7.5, and one T2.5) with known evidence for photometric variability due to dust clouds, anomalous red infrared colors, or low-gravity atmospheres. The polarimetric data were acquired with the LIRIS instrument on the William Herschel Telescope. We also provide mid-infrared photometry in the interval 3.4-24 {mu}m for some targets obtained with Spitzer and WISE, which has allowed us to confirm the peculiar red colors of five sources in the sample. We can impose modest upper limits of 0.9% and 1.8% on the linear polarization degree for seven targets with a confidence of 99%. Only one source, 2MASS J02411151-0326587 (L0), appears to be strongly polarized (P {approx} 3%) in the J band with a significance level of P/{sigma}{sub P} {approx} 10. The likely origin of its linearly polarized light and rather red infrared colors may reside in a surrounding disk with an asymmetric distribution of grains. Given its proximity (66 {+-} 8 pc), this object becomes an excellent target for the direct detection of the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and performance of SiPM-based readout of PbF 2 crystals for high-rate, precision timing applications

Here, we have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. As a result, the performance is documented in a series of bench and beam tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid level sensing for harsh environment applications using distributed fiber optic temperature measurements

This work demonstrates the measurement of liquid level from spatially distributed temperature measurements using optical frequency domain reflectometry. The goal of this work is to provide initial evidence for a liquid level sensor concept that could be applied in harsh environments such as those with: conductive, flammable, or other chemically aggressive media; electromagnetic interference; high temperatures (up to ~1000 °C); and neutron/gamma radiation. The sensor concept includes fiber optic sensors, along with an insulated heater wire assembled inside a protective Inconel 600 sheath. When the heater is not powered, the sensor provides spatially distributed temperature measurements along the length of the fiber. When the heater is powered, the difference in heat transfer in the liquid vs. vapor sections leads to a higher fiber temperature at locations above the liquid/vapor interface. The initial demonstration described in this work tested the sensor in a tank of water that was drained in increments of 2.5 cm. A model for determining liquid level from the distributed temperature measurements was developed that resulted in an accuracy of ±0.5 cm. Finally, the paper addresses potential effects of axial conduction through the sensor sheath, as well as ways to limit these effects to avoid “smearing” of what would otherwise be a step change in temperature at the liquid/vapor interface.

42 ENGINEERING↗

Effect of long duration UV irradiation on diamondlike carbon surfaces in the presence of a hydrocarbon gaseous atmosphere

Measurements of the effect of long duration UV irradiation (up to 2905 min) of flight quality diamondlike carbon charge state conversion surfaces for application in space research in the presence of a hydrocarbon atmosphere were done. An isopropanol atmosphere was used for simulating the hydrocarbon gaseous environment for an instrument on a satellite in space. Charge state conversion surfaces are used in neutral particle sensing instruments where neutral atoms have to be ionized prior to the analysis. A narrow-band (126{+-}5 nm) discharge lamp and a broad-band deuterium lamp (112-370 nm) were used as sources of UV radiation. The UV irradiation of a surface results in the desorption of some volatiles present on the surface and the decomposition of others. Desorption of volatiles, mostly water, is observed for both UV sources. The decomposition of the hydrocarbons and the subsequent build-up of a hydrocarbonaceous layer is only observed for the broad-band UV lamp, which is more representative for the space environment. Unfortunately, the hydrocarbonaceous layer cannot be removed thermally, i.e., it is permanent, and causes a degradation of the performance of the charge state conversion surfaces. With the present measurements we can quantify the UV influence at which the degradation of the conversion surfaces becomes noticeable.

36 MATERIALS SCIENCE↗

Extending accurate spectral induced polarization measurements into the kHz range: modelling and removal of errors from interactions between the parasitic capacitive coupling and the sample holder

SUMMARY Spectral induced polarization (SIP), describing the measurement of the frequency domain electrical impedance magnitude and phase of porous materials, has been widely used to characterize subsurface hydrological/biogeochemical properties and processes. SIP data collected at frequencies higher than 100 Hz are expected to describe the polarization of small particles providing insights into the physicochemical properties of clays, nanoparticles and microorganisms. However, the phase measurements at these high frequencies are often contaminated by errors due to the parasitic capacitive coupling of the SIP instrument, especially for lower conductivity samples. We developed a model showing the measured phase is the sum of the true sample phase and an error term ωCinZx, where ω is the angular frequency; Cin is the instrument input capacitance and Zx is a measurable impedance function related to the sample holder properties and the reference resistor. Based on this model, a new phase correction method is proposed that results in highly accurate SIP data up to 20 kHz as well as the determination of Cin. We tested the correction method using electric circuits, NaCl fluids and three unconsolidated samples (sand, sand-clay and sand-pyrite mixtures). The corrected phase for the circuit and NaCl fluid experiments showed excellent agreement with the theoretical phase response across the studied frequency range (errors <1 mrad). For unconsolidated samples, removal of errors results in phase spectra more consistent with expected polarization mechanisms, as based on phase peaks recorded for small pyrite and clay particles at high frequencies. These phase peaks could not be identified in the uncorrected data. Our approach can substantially enhance the value of the SIP method for the characterization of fine-grained sediments and rocks.

58 GEOSCIENCES↗

Mu2e Calorimeter Readout System

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads , neutron flux of 10 12 n(1MeVeq)/cm 2 , magnetic field of 1T and in vacuum level of 10 -4 Torr . A description of the readout system and qualification tests is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SWIFT OBSERVATIONS OF GAMMA-RAY BURST PULSE SHAPES: GRB PULSE SPECTRAL EVOLUTION CLARIFIED

Isolated Swift gamma-ray burst (GRB) pulses, like their higher-energy BATSE counterparts, emit the bulk of their pulsed emission as a hard-to-soft component that can be fitted by the Norris et al. empirical pulse model. This signal is overlaid by a fainter, three-peaked signal that can be modeled by the residual fit of Hakkila and Preece: the two fits combine to reproduce GRB pulses with distinctive three-peaked shapes. The precursor peak appears on or before the pulse rise and is often the hardest component, the central peak is the brightest, and the decay peak converts exponentially decaying emission into a long, soft, power-law tail. Accounting for systematic instrumental differences, the general characteristics of the fitted pulses are remarkably similar. Isolated GRB pulses are dominated by hard-to-soft evolution; this is more pronounced for asymmetric pulses than for symmetric ones. Isolated GRB pulses can also exhibit intensity tracking behaviors that, when observed, are tied to the timing of the three peaks: pulses with the largest maximum hardnesses are hardest during the precursor, those with smaller maximum hardnesses are hardest during the central peak, and all pulses can re-harden during the central peak and/or during the decay peak. Since these behaviors are essentially seen in all isolated pulses, the distinction between “hard-to-soft and “intensity-tracking” pulses really no longer applies. Additionally, the triple-peaked nature of isolated GRB pulses seems to indicate that energy is injected on three separate occasions during the pulse duration: theoretical pulse models need to account for this.

79 ASTRONOMY AND ASTROPHYSICS↗

Inspection of plate weldments through an interposed layer of viscoelastic material using an elastic-electromagnetic scanning method

In this study, an elastic-microwave based non-destructive evaluation method is presented to inspect for cracks in weldments and thinning of coated steel plates. The approach uses a microwave interferometer operating at 94 GHz to record the total surface displacement of a coated steel plated as it is driven by an incident elastic field. These spatiotemporal data coupled with wavefield processing algorithms provide powerful detection and localization capabilities. From these wavefield data sets, a plate thickness mapping capability has been demonstrated that can detect thickness changes on the order of 0.79 mm (1/32 in.). It is also shown that a topological energy analysis of the wavefield data can detect and locate small flaws on the order of 5–10 mm (0.19–0.40 in.) in the welded joint. Note, all of these results are obtained through a 50.8 mm (2 in.) thick viscoelastic coating without disturbing the coating or the coating bond. At present the algorithm cannot resolve individual flaws within a grid space, just their cumulative effect. Even with the current limitations, this detection approach appears to be a promising alternative to traditional phased array imaging methods where the coating layer must be removed prior to inspection.

42 ENGINEERING↗