Application of convolve-multiply-convolve SAW processor for satellite communications

There is a need for a satellite communications receiver than can perform simultaneous multi-channel processing of single channel per carrier (SCPC) signals originating from various small (mobile or fixed) earth stations. The number of ground users can be as many as 1000. Conventional techniques of simultaneously processing these signals is by employing as many RF-bandpass filters as the number of channels. Consequently, such an approach would result in a bulky receiver, which becomes impractical for satellite applications. A unique approach utilizing a realtime surface acoustic wave (SAW) chirp transform processor is presented. The application of a Convolve-Multiply-Convolve (CMC) chirp transform processor is described. The CMC processor transforms each input channel into a unique timeslot, while preserving its modulation content (in this case QPSK). Subsequently, each channel is individually demodulated without the need of input channel filters. Circuit complexity is significantly reduced, because the output frequency of the CMC processor is common for all input channel frequencies. The results of theoretical analysis and experimental results are in good agreement.

Lie, Y. S.↗

Pulsed laser spectral measurement using a Fabry-Perot interferometer: Limits to resolution

We are developing a Doppler lidar system using the edge technique to measure atmospheric wind profiles. The edge technique requires a laser with a narrow spectral bandwidth and a high resolution optical filter. The lidar system will use a Nd:YAG laser operating at 1.064 microns and a high resolution Fabry-Perot interferometer for the edge filter. The Doppler shift measurement is made by locating the laser on the edge of the filter's spectral response function. Due to the steep slope on the edge, large changes in the filter transmission will be observed for small changes in frequency. The Doppler shift can be determined from a measurement of this change in filter transmission if the filter spectral response function in the region of the measurement is well known. Recently developed injection seeded solid state lasers have made near transform limited laser output readily available for lidar work. Injection-seeded Nd:YAG laser exhibit single mode output with smooth Gaussian temporal pulse shapes. Results of an experiment we conducted to evaluate the effects of a short Gaussian temporal input pulse on the spectral response of a high resolution Fabry-Perot interferometer are presented.

Notari, Anthony↗

A comparison of extinction curves for dust in galaxies of different Hubble types

A sample of 25 galaxies of various Hubble types has been observed in a variety of filters. Extinction curves have been generated for absorption regions in these galaxies using a technique which previously had been used on just a few galaxies; for example, NGC 205, NGC 185, NGC 3077, and M31. The results from these studies suggested that there may be systematic trends in dust properties with Hubble type. This would not be surprising; dust properties should vary with metallicity, for example. It is well known that some galaxies and their interstellar materials should reflect this difference.

Townsley, Leisa K.↗

Noise, Edge Extraction and Visibility of Features

Noise, whether due to the image-gathering device or some other reason, reduces the visibility of fine features in an image. Several techniques attempt to mitigate the impact of noise by performing a low-pass filtering operation on the acquired data. This is based on the assumption that the uncorrelated noise has high-frequency content and thus will be suppressed by low-pass filtering. A result of this operation is that edges in a noisy image also tend to get blurred, and, in some cases, may get completely lost due to the low-pass filtering. In this paper, we quantitatively assess the impact of noise on fine feature visibility by using computer-generated targets of known spatial detail. Additionally, we develop a new scheme for noise-reduction based on the connectivity of edge-features. The overall impact of this scheme is to reduce overall noise, yet retain the high frequency content that make edge-features sharp.

Rahman, Zia-ur↗

High-Temperature Properties of Piezoelectric Langatate Single Crystals

Langasite type crystals belong to non-polar point group of 32 and do not show any phase transformations up to the melting temperature. Langatate (La3Ga(5.5)Ta(0.5)O14) demonstrates piezoelectric activity better than quartz and possesses attractive properties for high temperature sensors, resonators and filter applications. High-quality and colorless langatate crystals were grown by the Czochralski technique. The electromechanical and electrical properties of langatate crystals in different crystallographic directions were characterized at elevated temperature. The piezoelectric coefficient along x-axis was 7 pC/N as measured by a Berlincourt meter for a plate geometry with an aspect ratio of 10:1. The dielectric constant did not exhibit any significant temperature dependence (K33 approx. 21 at 30 C and K33 approx. 23 at 600 C). Loss tangent at 100 kHz remained <0.003 up to 300 C and <0.65 at 600 C. The dielectric properties along the y-axis were similar and its temperature dependence was analogous to the x-axis. Electromechanically, the inactive z-axis exhibited no resonance with K33 approx. 84 at room temperature, decreasing down to approx. 49 at 600 C. Resistivity of these crystals along x-axis decreased from approx. 6x10(exp 11) omega-cm at room temperature, to approx. 1.6x10(exp 6) omega-cm at 600 C.

Sehirlioglu, Alp↗

Visualizing Flutter Mechanism as Traveling Wave Through Animation of Simulation Results for the Semi-Span Super-Sonic Transport Wind-Tunnel Model

It has long been recognized that frequency and phasing of structural modes in the presence of airflow play a fundamental role in the occurrence of flutter. Animation of simulation results for the long, slender Semi-Span Super-Sonic Transport (S4T) wind-tunnel model demonstrates that, for the case of mass-ballasted nacelles, the flutter mode can be described as a traveling wave propagating downstream. Such a characterization provides certain insights, such as (1) describing the means by which energy is transferred from the airflow to the structure, (2) identifying airspeed as an upper limit for speed of wave propagation, (3) providing an interpretation for a companion mode that coalesces in frequency with the flutter mode but becomes very well damped, (4) providing an explanation for bursts of response to uniform turbulence, and (5) providing an explanation for loss of low frequency (lead) phase margin with increases in dynamic pressure (at constant Mach number) for feedback systems that use sensors located upstream from active control surfaces. Results from simulation animation, simplified modeling, and wind-tunnel testing are presented for comparison. The simulation animation was generated using double time-integration in Simulink of vertical accelerometer signals distributed over wing and fuselage, along with time histories for actuated control surfaces. Crossing points for a zero-elevation reference plane were tracked along a network of lines connecting the accelerometer locations. Accelerometer signals were used in preference to modal displacement state variables in anticipation that the technique could be used to animate motion of the actual wind-tunnel model using data acquired during testing. Double integration of wind-tunnel accelerometer signals introduced severe drift even with removal of both position and rate biases such that the technique does not currently work. Using wind-tunnel data to drive a Kalman filter based upon fitting coefficients to analytical mode shapes might provide a better means to animate the wind tunnel data.

Christhilf, David M.↗

Signal Processing for Determining Water Height in Steam Pipes with Dynamic Surface Conditions

An enhanced signal processing method based on the filtered Hilbert envelope of the auto-correlation function of the wave signal has been developed to monitor the height of condensed water through the steel wall of steam pipes with dynamic surface conditions. The developed signal processing algorithm can also be used to estimate the thickness of the pipe to determine the cut-off frequency for the low pass filter frequency of the Hilbert Envelope. Testing and analysis results by using the developed technique for dynamic surface conditions are presented. A multiple array of transducers setup and methodology are proposed for both the pulse-echo and pitch-catch signals to monitor the fluctuation of the water height due to disturbance, water flow, and other anomaly conditions.

health monitoring↗

Recent developments at JPL in the application of image processing to astronomy

Four applications of image processing to astronomy, automated location and analysis of star and galaxy images, geometric and radiometric decalibration of vidicon spectra, display of multiband radio images, and generation of high resolution polarization direction and magnitude maps from images are presented with illustrative examples. The technique by which a digital image can be analyzed automatically to locate and segregate between stars and galaxies and the steps performed by the classifier to determine the nature of each object are outlined. The classification program executed on a 48 inch Schmidt plate of the cluster of galaxies 655 is described. The calibration and decalibration steps to remove geometric and radiometric distortions from a silicon vidicon camera digital spectra are discussed. Three methods of displaying multispectral radio data, generating a mosaic of each image, producing a color coded image to depict radio velocity, and producing a stereo pair with radial velocity as depth are described. The generation of polarization information from images obtained through linear polarizing filters is illustrated, and it is concluded that in each case information was displayed using digital techniques which could not readily have been provided visually.

Lorre, J. J.↗

Nanoporous separators for supercapacitor using activated carbon monolith electrode from oil palm empty fruit bunches

Activated porous carbon electrode prepared from fibres of oil palm empty fruit bunches was used for preparing the carbon based supercapacitor cells. The symmetrical supercapacitor cells were fabricated using carbon electrodes, stainless steel current collector, H{sub 2}SO{sub 4} electrolyte, and three types of nanoporous separators. Cells A, B and C were fabricated using polypropylene, eggshell membrane, and filter paper, respectively. Electrochemical characterizations data from Electrochemical Impedance Spectroscopy, Cyclic Voltammetry, and Galvanic Charge Discharge techniques showed that specific capacitance, specific power and specific energy for cell A were 122 F g{sup −1}, 177 W kg{sup −1}, 3.42 Wh kg{sup −1}, cell B; 125 F g{sup −1}, 179 W kg{sup −1}, and 3.64 Wh kg{sup −1}, and cell C; 180 F g{sup −1}, 178 W kg{sup −1}, 4.27 Wh kg{sup −1}. All the micrographs from Field Emission Scanning Electron Microscope showed that the different in nanoporous structure of the separators lead to a significant different in influencing the values of specific capacitance, power and energy of supercapacitors, which is associated with the mobility of ion into the pore network. These results indicated that the filter paper was superior than the eggshell membrane and polypropylene nanoporous separators. However, we found that in terms of acidic resistance, polypropylene was the best nanoporous separator for acidic medium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recovery of hygiene water by multifiltration

A multifiltration hygiene water reclamation process that utilizes adsorption and particulate filtration techniques is described and evaluated. The applicability of the process is tested using a simulation of a 4-man subsystem operation for 240 days. It is proposed the process has a 10 year life, weighs 236 kg, and uses 88 kg of expendable filters and adsorption beds to process 8424 kg of water. The data reveal that the multifiltration is an efficient nonphase change technique for hygiene water recovery and that the chemical and microbiological purity of the product water is within the standards specified for the Space Station hygiene water.

Putnam, David F.↗

Can 3-D models explain the observed fractions of fossil and non-fossil carbon in and near Mexico City?

Abstract. A 3-D chemistry-transport model has been applied to the Mexico City metropolitan area to investigate the origin of elevated levels of non-fossil (NF) carbonaceous aerosols observed in this highly urbanized region. High time resolution measurements of the fine aerosol concentration and composition, and 12 or 24 h integrated 14C measurements of aerosol modern carbon have been performed in and near Mexico City during the March 2006 MILAGRO field experiment. The non-fossil carbon fraction (fNF), which is lower than the measured modern fraction (fM) due to the elevated 14C in the atmosphere caused by nuclear bomb testing, is estimated from the measured fM and the source-dependent information on modern carbon enrichment. The fNF contained in PM1 total carbon analyzed by a US team (f TC NF ) ranged from 0.37 to 0.67 at the downtown location, and from 0.50 to 0.86 at the suburban site. Substantially lower values (i.e. 0.24–0.49) were found for PM10 filters downtown by an independent set of measurements (Swiss team), which are inconsistent with the modeled and known differences between the size ranges, suggesting higher than expected uncertainties in the measurement techniques of 14C. An increase in the non-fossil organic carbon (OC) fraction (f OC NF ) by 0.10–0.15 was observed for both sets of filters during periods with enhanced wildfire activity in comparison to periods when fires were suppressed by rain, which is consistent with the wildfire impacts estimated with other methods. Model results show that the relatively high fraction of nonfossil carbon found in Mexico City seems to arise from the combination in about equal proportions of regional biogenic SOA, biomass burning POA and SOA, as well as non-fossil urban POA and SOA. Predicted spatial and temporal variations for f OC NF are similar to those in the measurements between the urban vs. suburban sites, and high-fire vs. low-fire periods. The absolute modeled values of f OC NF are consistent with the Swiss dataset but lower than the US dataset. Resolving the 14C measurement discrepancies is necessary for further progress in model evaluation. The model simulations that included secondary organic aerosol (SOA) formation from semi-volatile and intermediate volatility (S/IVOC) vapors showed improved closure for the total OA mass compared to simulations which only included SOA from VOCs, providing a more realistic basis to evaluate the fNF predictions. f OC NF urban sources of modern carbon are important in reducing or removing the difference in fNF between model and measurements, even though they are often neglected on the interpretation of 14C datasets. An underprediction of biomass burning POA by the model during some mornings also explains a part of the model-measurement differences. The fNF of urban POA and SOA precursors is an important parameter that needs to be better constrained by measurements. Performing faster ( 3 h) 14C measurements in future campaigns is critical to further progress in this area. To our knowledge this is the first time that radiocarbon measurements are used together with aerosol mass spectrometer (AMS) organic components to assess the performance of a regional model for organic aerosols.

09 BIOMASS FUELS↗

Wiener filtering of the COBE Differential Microwave Radiometer data

We derive an optimal linear filter to suppress the noise from the cosmic background explorer satellite (COBE) Differential Microwave Radiometer (DMR) sky maps for a given power spectrum. We then apply the filter to the first-year DMR data, after removing pixels within 20 deg of the Galactic plane from the data. We are able to identify particular hot and cold spots in the filtered maps at a level 2 to 3 times the noise level. We use the formalism of constrained realizations of Gaussian random fields to assess the uncertainty in the filtered sky maps. In addition to improving the signal-to-noise ratio of the map as a whole, these techniques allow us to recover some information about the cosmic microwave background anisotropy in the missing Galactic plane region. From these maps we are able to determine which hot and cold spots in the data are statistically significant, and which may have been produced by noise. In addition, the filtered maps can be used for comparison with other experiments on similar angular scales.

Bunn, Emory F.↗

THE REAL ISSUE WITH WALL DEPOSITS IN CLOSED FILTER CASSETTES - WHAT'S THE SAMPLE?

The measurement of aerosol dusts has long been utilized to assess the exposure of workers to metals. Tools used to sample and measure aerosol dusts have gone through many transitions over the past century. In particular, there have been several different techniques used to sample for beryllium, not all of which might be expected to produce the same result. Today, beryllium samples are generally collected using filters housed in holders of several different designs, some of which are expected to produce a sample that mimics the human capacity for dust inhalation. The presence of dust on the interior walls of cassettes used to hold filters during metals sampling has been discussed in the literature for a number of metals, including beryllium, with widely varying data. It appears that even in the best designs, particulates can enter the sampling cassette and deposit on the interior walls rather than on the sampling medium. The causes are not well understood but are believed to include particle bounce, electrostatic forces, particle size, particle density, and airflow turbulence. Historically, the filter catch has been considered to be the sample, but the presence of wall deposits, and the potential that the filter catch is not representative of the exposure to the worker, puts that historical position into question. This leads to a fundamental question: What is the sample? This article reviews the background behind the issue, poses the above-mentioned question, and discusses options and a possible path forward for addressing that question.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Spectroscopy for Chemical Analysis (ESCA) study of atmospheric particles

The results of analyses by ESCA (Electron Spectroscopy for Chemical Analysis) on several Nuclepore filters which were exposed during air pollution studies are presented along with correlative measurements by Neutron Activation Analysis and Scanning Electron Microscopy. Samples were exposed during air pollution studies at Norfolk, Virginia and the NASA Kennedy Space Center (KSC). It was demonstrated that with the ESCA technique it was possible to identify the chemical (bonding) state of elements contained in the atmospheric particulate matter collected on Nuclepore filters. Sulfur, nitrogen, mercury, chlorine, alkali, and alkaline earth metal species were identified in the Norfolk samples. ESCA binding energy data for aluminum indicated that three chemically different types of aluminum are present in the launch and background samples from NASA-KSC.

Dillard, J. G.↗

THE 1998 NOVEMBER 14 OCCULTATION OF GSC 0622-00345 BY SATURN. I. TECHNIQUES FOR GROUND-BASED STELLAR OCCULTATIONS

On 1998 November 14, Saturn and its rings occulted the star GSC 0622-00345. We observed atmospheric immersion with NSFCAM at the National Aeronautics and Space Administration's Infrared Telescope Facility on Mauna Kea, Hawaii. Immersion occurred at 55.{sup 0}5 S planetocentric latitude. A 2.3 {mu}m, CH{sub 4}-band filter suppressed reflected sunlight. Atmospheric emersion and ring data were not successfully obtained. We describe our observation, light curve production, and timing techniques, including improvements in aperture positioning, removal of telluric scintillation effects, and timing. Many of these techniques are known within the occultation community, but have not been described in the reviewed literature. We present a light curve whose signal-to-noise ratio per scale height is 267, among the best ground-based signals yet achieved, despite a disadvantage of up to 8 mag in the stellar flux compared to prior work.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic measurements of whole-body dose distributions for various treatment machines and delivery techniques in radiation therapy

Purpose: Contemporary radiotherapy treatment techniques, such as intensity-modulated radiation therapy and volumetric modulated arc therapy, could increase the radiation-induced malignancies because of the increased beam-on time, i.e., number of monitor units needed to deliver the same dose to the target and the larger volume irradiated with low doses. In this study, whole-body dose distributions from typical radiotherapy patient plans using different treatment techniques and therapy machines were measured using the same measurement setup and irradiation intention. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from 6 MV beams were compared in terms of treatment technique (3D-conformal, intensity-modulated radiation therapy, volumetric modulated arc therapy, helical TomoTherapy, stereotactic radiotherapy, hard wedges, and flattening filter-free radiotherapy) and therapy machine (Elekta, Siemens and Varian linear accelerators, Accuray CyberKnife and TomoTherapy). Results: Close to the target, the doses from intensity-modulated treatments (including flattening filter-free) were below the dose from a static treatment plan, whereas the CyberKnife showed a larger dose by a factor of two. Far away from the treatment field, the dose from intensity-modulated treatments showed an increase in dose from stray radiation of about 50% compared to the 3D-conformal treatment. For the flattening filter-free photon beams, the dose from stray radiation far away from the target was slightly lower than the dose from a static treatment. The CyberKnife irradiation and the treatment using hard wedges increased the dose from stray radiation by nearly a factor of three compared to the 3D-conformal treatment. Conclusions: This study showed that the dose outside of the treated volume is influenced by several sources. Therefore, when comparing different treatment techniques, the dose ratios vary with distance to the isocenter. The effective dose outside the treated volume of intensity-modulated treatments with or without flattening filter was 10%-30% larger when compared to 3D-conformal radiotherapy. This dose increase is much lower than the monitor unit scaled effective dose from a static treatment.

60 APPLIED LIFE SCIENCES↗

Quantum interferometry and pathway selectivity in the nonlinear response of photosynthetic excitons

We propose a time–frequency resolved spectroscopic technique which employs nonlinear interferometers to study exciton–exciton scattering in molecular aggregates. A higher degree of control over the contributing Liouville pathways is obtained as compared to classical light. We show how the nonlinear response can be isolated from the orders-of-magnitude stronger linear background by either phase matching or polarization filtering. Both arise due to averaging the signal over a large number of noninteracting, randomly oriented molecules. We apply our technique to the Frenkel exciton model which excludes charge separation for the photosystem II reaction center. We show how the sum of the entangled photon frequencies can be used to select two-exciton resonances, while their delay times reveal the single-exciton levels involved in the optical process.

Science & Technology - Other Topics↗

Techniques to improve the accuracy of noise power spectrum measurements in digital x-ray imaging based on background trends removal

Purpose: Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. Extensive works have been conducted to achieve accurate and precise measurement of NPS. One approach to improve the accuracy of the NPS measurement is to reduce the statistical variance of the NPS results by involving more data samples. However, this method is based on the assumption that the noise in a radiographic image is arising from stochastic processes. In the practical data, the artifactuals always superimpose on the stochastic noise as low-frequency background trends and prevent us from achieving accurate NPS. The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems. Methods: In order to achieve the optimal background detrending technique for NPS estimate, four methods for artifactuals removal were quantitatively studied and compared: (1) Subtraction of a low-pass-filtered version of the image, (2) subtraction of a 2-D first-order fit to the image, (3) subtraction of a 2-D second-order polynomial fit to the image, and (4) subtracting two uniform exposure images. In addition, background trend removal was separately applied within original region of interest or its partitioned sub-blocks for all four methods. The performance of background detrending techniques was compared according to the statistical variance of the NPS results and low-frequency systematic rise suppression. Results: Among four methods, subtraction of a 2-D second-order polynomial fit to the image was most effective in low-frequency systematic rise suppression and variances reduction for NPS estimate according to the authors' digital x-ray system. Subtraction of a low-pass-filtered version of the image led to NPS variance increment above low-frequency components because of the side lobe effects of frequency response of the boxcar filtering function. Subtracting two uniform exposure images obtained the worst result on the smoothness of NPS curve, although it was effective in low-frequency systematic rise suppression. Subtraction of a 2-D first-order fit to the image was also identified effective for background detrending, but it was worse than subtraction of a 2-D second-order polynomial fit to the image according to the authors' digital x-ray system. Conclusions: As a result of this study, the authors verified that it is necessary and feasible to get better NPS estimate by appropriate background trend removal. Subtraction of a 2-D second-order polynomial fit to the image was the most appropriate technique for background detrending without consideration of processing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗