Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Technical Note: Suppression of artifacts arising from simultaneous cone-beam imaging and RF transponder tracking in prostate radiotherapy

Purpose: Artifacts in treatment-room cone-beam reconstructions have been observed at the authors' center when cone-beam acquisition is simultaneous with radio frequency (RF) transponder tracking using the Calypso 4D system (Calypso Medical, Seattle, WA). These artifacts manifest as CT-number modulations and increased CT-noise. The authors present a method for the suppression of the artifacts. Methods: The authors propose a three-stage postprocessing technique that can be applied to image volumes previously reconstructed by a cone-beam system. The stages are (1) segmentation of voxels into air, soft-tissue, and bone; (2) application of a 2D spatial-filter in the axial plane to the soft-tissue voxels; and (3) normalization to remove streaking along the axial-direction. The algorithm was tested on patient data acquired with Synergy XVI cone-beam CT systems (Elekta, Crawley, United Kingdom). Results: The computational demands of the suggested correction are small, taking less than 15 s per cone-beam reconstruction on a desktop PC. For a moderate loss of spatial-resolution, the artifacts are strongly suppressed and low-contrast visibility is improved. Conclusions: The correction technique proposed is fast and effective in removing the artifacts caused by simultaneous cone-beam imaging and RF-transponder tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-207A-11: Respiratory Motion Guided 4DCBCT - A Step Towards Controlling 4DCBCT Image Quality

Purpose: We have developed a method, called respiratory motion guided 4DCBCT (RMG-4DCBCT), in which the gantry speed and projection frequency are varied in response to the patient’s real-time respiratory signal to eliminate streaking artifacts and to suppress duplicate projections in 4DCBCT images. In 2015, we realized RMG-4DCBCT on an Elekta Synergy linear accelerator with a mechanical relay to suppress projections and a potentiometer to adjust the gantry speed in response to the patient’s real-time respiratory signal. The aim of this study was to analyse the image quality to determine what can and cannot be controlled. Methods: Using RMG-4DCBCT, we acquired 40 (RMG-4DCBCT-40) and 60 (RMG-4DCBCT-60) equally spaced projections per respiratory phase of the CIRS dynamic thorax phantom with breathing periods from 2s to 8s and two breathing traces from lung cancer patients. The contrast to noise ratio (CNR) and edge response width (ERW) were used to compare image quality between RMG-4DCBCT and conventional 4DCBCT. Results: Regardless of the breathing period, for RMG-4DCBCT, the CNR is approximately 7 and 9 with RMG-4DCBCT-40 and RMG-4DCBCT-60 respectively. Conventional 4DCBCT has a CNR dropping from 20 down to 6 as the breathing period drops from 2s to 8s. With RMG-4DCBCT, the ERW, in the direction of phantom motion, ranges from 2.1mm to 2.5mm as the breathing period drops from 2s to 8s which compares to a higher range of 2.0mm to 2.5mm with conventional 4DCBCT. Images with similar quality to conventional 4DCBCT can be acquired with RMG-4DCBCT-40 which has a 70% reduction in imaging dose. Conclusion: The image contrast can be controlled with RMG-4DCBCT regardless of the patients breathing rate. However, although the image sharpness is better with RMG-4DCBCT, image sharpness has a small dependence on the breathing period; the accuracy of registration and segmentation will therefore vary with the patient’s breathing period. This project was supported by a National Health and Medical Research Council (NHMRC) project grant 1034060 and Cancer Australia grant number 1084566.

60 APPLIED LIFE SCIENCES↗

Scientific requirements for a Moderate-Resolution Imaging Spectrometer (MODIS) for EOS

The MODIS is an instrument planned for the sun-synchronous polar orbiting segment of the Space Station system. The radiometer is required to have 1 km resolution in terrestrial remote sensing applications. The monitoring program is targeted to last 10 yr in order to provide a sufficient database for discerning trends as opposed to natural variations. The study areas of interest include tropical deforestation, regrowth and areal distributions, acid rain effects on northern forests, desertification rates and locations, snow cover/albedo relationships and total biomass. MODIS will have 192 channels with 30 m spatial resolution and cover seven bands in the 3.5-12 microns interval for land viewing. Ocean studies will be carried out in 17 bands from 0.4-1.0 micron, and atmospheric scans will be performed over the land and ocean intervals at narrowband wavelengths (1.2 nm). Si detector arrays will be used and will be accompanied by an expected 600:1 SNR and produce data at a rate of 1.4-9.1 Mb/sec.

Barnes, W. L.↗

Earth Observing System instrument performance - Moderate Resolution Imaging Spectrometer case study

The requirements for characterization and calibration of instruments for the Earth Observing System space segment are defined in terms of tracking the Level 1 data for a sensor. The data must be traceable over the 15 year program, and must provide corrections for radiometric, spectral and geometric coefficients which capture the combined design and performance characteristics of the sensor. These requirements are then developed for MODIS-N to identify a set of techniques which can be used in the laboratory, spacecraft integrator's facility and in-orbit. The in-orbit of the so-called reflectance and radiance methods are reviewed, and the cross-calibrations available between HIRIS and MODIS through these techniques are listed. A scheme for the use of all available tools for instrument performance is provided as a Figure showing an estimated time interval over which each tool is expected to be useful. The final calibration strategy and plan must be developed through the understanding of a useful strategy for each of these candidate mechanisms.

Guenther, Bruce W.↗

Semiautomated segmentation of head and neck cancers in 18F-FDG PET scans: A just-enough-interaction approach

Purpose: The purpose of this work was to develop, validate, and compare a highly computer-aided method for the segmentation of hot lesions in head and neck 18F-FDG PET scans. Methods: A semiautomated segmentation method was developed, which transforms the segmentation problem into a graph-based optimization problem. For this purpose, a graph structure around a user-provided approximate lesion centerpoint is constructed and a suitable cost function is derived based on local image statistics. To handle frequently occurring situations that are ambiguous (e.g., lesions adjacent to each other versus lesion with inhomogeneous uptake), several segmentation modes are introduced that adapt the behavior of the base algorithm accordingly. In addition, the authors present approaches for the efficient interactive local and global refinement of initial segmentations that are based on the “just-enough-interaction” principle. For method validation, 60 PET/CT scans from 59 different subjects with 230 head and neck lesions were utilized. All patients had squamous cell carcinoma of the head and neck. A detailed comparison with the current clinically relevant standard manual segmentation approach was performed based on 2760 segmentations produced by three experts. Results: Segmentation accuracy measured by the Dice coefficient of the proposed semiautomated and standard manual segmentation approach was 0.766 and 0.764, respectively. This difference was not statistically significant (p = 0.2145). However, the intra- and interoperator standard deviations were significantly lower for the semiautomated method. In addition, the proposed method was found to be significantly faster and resulted in significantly higher intra- and interoperator segmentation agreement when compared to the manual segmentation approach. Conclusions: Lack of consistency in tumor definition is a critical barrier for radiation treatment targeting as well as for response assessment in clinical trials and in clinical oncology decision-making. The properties of the authors approach make it well suited for applications in image-guided radiation oncology, response assessment, or treatment outcome prediction.

60 APPLIED LIFE SCIENCES↗

Outer Wall Segmentation of Abdominal Aortic Aneurysm by Variable Neighborhood Search Through Intensity and Gradient Spaces

Aortic aneurysm segmentation remains a challenge. Manual segmentation is a time-consuming process which is not practical for routine use. To address this limitation, several automated segmentation techniques for aortic aneurysm have been developed, such as edge detection-based methods, partial differential equation methods, and graph partitioning methods. However, automatic segmentation of aortic aneurysm is difficult due to high pixel similarity to adjacent tissue and a lack of color information in the medical image, preventing previous work from being applicable to difficult cases. This paper uses uses a variable neighborhood search that alternates between intensity-based and gradient-based segmentation techniques. By alternating between intensity and gradient spaces, the search can escape from local optima of each space. The experimental results demonstrate that the proposed method outperforms the other existing segmentation methods in the literature, based on measurements of dice similarity coefficient and jaccard similarity coefficient at the pixel level. In addition, it is shown to perform well for cases that are difficult to segment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stellar Population Properties in the Stellar Streams around SPRC047

Abstract We have investigated the properties (e.g., age, metallicity) of the stellar populations of a ringlike tidal stellar stream (or streams) around the edge-on galaxy SPRC047 (z= 0.031) using spectral energy distribution (SED) fits to integrated broadband aperture flux densities. We used visual images in six different bands and Spitzer/IRAC 3.6μm data. We have attempted to derive best-fit stellar population parameters (metallicity, age) in three noncontiguous segments of the stream. Due to the very low surface brightness of the stream, we have performed a deconvolution with a Richardson–Lucy–type algorithm of the low spatial resolution 3.6μm IRAC image, thereby reducing the effect of the point-spread function aliasedemissionfrom the bright edge-on central galaxy at the locations of our three stream segments. Our SED fits that used several different star formation (SF) history priors, from an exponentially decaying SF burst to continuous SF, indicate that the age–metallicity–dust degeneracy is not resolved, most likely because of inadequate wavelength coverage and low signal-to-noise ratios of the low surface brightness features. We also discuss how future deep visual–near-infrared observations, combined with absolute flux calibration uncertainties at or below the 1% level, complemented by equally well absolute flux-calibrated observations in ultraviolet and mid-infrared bands, would improve the accuracy of broadband SED fitting results for low surface brightness targets, such as stellar streams around nearby galaxies that are not resolved into stars.

Astronomy & Astrophysics↗

Segmentation Of Multifrequency Complex-Amplitude SAR Data

Several mathematical models and associated algorithms implement method of segmenting multifrequency, highly speckled, high-resolution, complex-amplitude (amplitude and phase) synthetic-aperture-radar (SAR) digitized image into regions, within each of which radar backscattering characteristics are similar or homogeneous from place to place. Typically, each region represents different type of terrain or other surface; e.g., forest, agricultural land, sea ice, or water. Method of segmentation of SAR scene into regions is product of generalization, to multifrequency case, of single-frequency method described in "Algorithms for Segmentation of Complex-Amplitude SAR Data" (NPO-18524).

Rignot, Eric J.↗

Origins of Feeding Arteries of Hepatocellular Carcinoma Located Near the Umbilical Fissure of the Left Hepatic Lobe: Angiographic Evaluation

Purpose: To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Methods: Twenty-eight HCCs with a mean {+-} SD tumor diameter of 3.4 {+-} 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE.ResultsTwenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. Conclusion: This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of intermittent filaments in the scrape-off layer of NSTX

Filamentary structures naturally arise from background turbulence in the scrape-off layer (SOL) of plasmas, leading to significant particle and heat transport that can degrade overall plasma confinement. This enhanced transport can contribute to unacceptably high heat loads on plasma-facing components. As such, understanding the physics of SOL plasma filaments is critical for predicting and mitigating their effects in future fusion devices. On the National Spherical Torus Experiment (NSTX), plasma filaments—commonly referred to as “blobs”—were investigated using the gas-puff imaging (GPI) diagnostic in the edge and SOL regions. The analysis involved identifying, segmenting, and tracking the characteristic contours of the blobs in each frame of the GPI video sequences. Their evolution was characterized through shape descriptors, velocity, and angular velocity derived from their contour coordinates. The results indicate that as the blob area increases, their shapes become more concave and less circular, suggesting reduced structural stability in larger blobs. This result aligns with previous theoretical results where it was shown that larger blobs are more susceptible to instabilities [Krasheninnikov et al., J. Plasma Phys. 74, 679–717 (2008) and D'Ippolito et al., Phys. Plasmas 18, 060501 (2011)]. A positive correlation was observed between radial velocity and radial position, suggesting radially outward acceleration of the filaments, potentially driven by decreasing viscous drag toward the far SOL. Interestingly, blobs in background SOL turbulence exhibited minimal spinning in contrast to filaments originating from edge localized modes, which show substantial rotation during their paths [Lampert et al., Phys. Plasmas 29, 102502 (2022)]. Statistical analysis of the solidity and total curvature shape descriptors, along with their temporal evolution, revealed relatively broad, near-Gaussian distributions. This suggests that blob morphology is strongly influenced by stochastic turbulent processes in the surrounding plasma environment. Blob parameters were also compared with bulk plasma and radial profile measurements. Notable trends were found between blob rotation and poloidal velocity with collisionality and line-integrated density. These findings contribute to a deeper understanding of blob dynamics and provide valuable insights for refining SOL turbulence models.

Covariance and correlation↗

Particle trajectory representation learning with masked point modeling

Liquid argon time projection chambers (LArTPCs) offer millimeter-scale 3D images of particle trajectories, enabling precision studies of neutrino oscillation, detection of supernova and solar neutrinos, searches for exotic dark matter, and proton decay. Current approaches utilize supervised machine learning models, requiring extensive simulations of particle physics and detector response that can introduce bias. Self-supervised learning (SSL), a machine learning approach that learns useful representations of unlabeled data from the data itself, has significantly advanced how large datasets are utilized for representation learning; however, its potential for applications to sensory data in high precision particle physics experiments remains largely unexplored. We introduce the Point-based liquid argon masked autoencoder (PoLAr-MAE), a self-supervised framework that learns physically meaningful representations directly from unlabeled LArTPC images. PoLAr-MAE achieves remarkable data efficiency for a point-level segmentation task, outperforming fully supervised methods in low data regimes. Linear classifiers on model outputs demonstrate robust performance across multiple downstream tasks. Our results position sensor-level SSL as a practical foundation model strategy for LArTPCs.

Young, Samuel [Stanford Univ., CA (United States)]↗

ecospec v0.1.0

Bespoke software for segmenting plants in ecoFABs to monitor growth and health. Contains python libraries for image alignment, training neural networks and running inference.

Zwart, PetrusH [Lawrence Berkeley National Laborat↗

SE Great Basin Play Fairway Analysis Heat and Permeability CRS

Within this submission are multiple .tif images with accompanying metadata of magnetotelluric conductor occurrence, fault critical stress composite risk segment (CRS), permeability CRS, Quaternary mafic extrusions, Quaternary fault density, and Quaternary rhyolite maps. Each of these contributed to a final play fairway analysis (PFA) for the SE Great Basin study area.

15 GEOTHERMAL ENERGY↗

Texture classification using autoregressive filtering

A general theory of image texture models is proposed and its applicability to the problem of scene segmentation using texture classification is discussed. An algorithm, based on half-plane autoregressive filtering, which optimally utilizes second order statistics to discriminate between texture classes represented by arbitrary wide sense stationary random fields is described. Empirical results of applying this algorithm to natural and sysnthesized scenes are presented and future research is outlined.

Lawton, W. M.↗

Encoding spatial images: A fuzzy set theory approach

As the use of fuzzy set theory continues to grow, there is an increased need for methodologies and formalisms to manipulate obtained fuzzy subsets. Concepts involving relative position of fuzzy patterns are acknowledged as being of high importance in many areas. In this paper, we present an approach based on the concept of dominance in fuzzy set theory for modelling relative positions among fuzzy subsets of a plane. In particular, we define the following spatial relations: to the left (right), in front of, behind, above, below, near, far from, and touching. This concept has been implemented to define spatial relationships among fuzzy subsets of the image plane. Spatial relationships based on fuzzy set theory, coupled with a fuzzy segmentation, should therefore yield realistic results in scene understanding.

Sztandera, Leszek M.↗