Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Roadmap for Research, Development, and Demonstration of Instrumentation, Controls, and Human-Machine Interface Technologies

Instrumentation, controls, and human-machine interfaces are essential enabling technologies that strongly influence nuclear power plant performance and operational costs. The nuclear power industry is currently engaged in a transition from traditional analog-based instrumentation, controls, and human-machine interface (ICHMI) systems to implementations employing digital technologies. This transition has primarily occurred in an ad hoc fashion through individual system upgrades at existing plants and has been constrained by a number of concerns. Although international implementation of evolutionary nuclear power plants and the progression toward new plants in the United States have spurred design of more fully digital plant-wide ICHMI systems, the experience base in the nuclear power application domain is limited. Additionally, design and development programs by the U.S. Department of Energy (DOE) for advanced reactor concepts, such as the Generation IV Program and Next Generation Nuclear Plant (NGNP), introduce different plant conditions and unique plant configurations that increase the need for enhanced ICHMI capabilities to fully achieve programmatic goals related to economic competitiveness, safety and reliability, sustainability, and proliferation resistance and physical protection. As a result, there are challenges that need to be addressed to enable the nuclear power industry to effectively and efficiently complete the transition to safe and comprehensive use of digital technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The mechanical design and dynamic testing of the IBEX-H1 electrostatic analyzer spacecraft instrument

This paper presents the mechanical design, fabrication and dynamic testing of an electrostatic analyzer spacecraft instrument. The functional and environmental requirements combined with limited spacecraft accommodations, resulted in complex component geometries, unique material selections, and difficult fabrication processes. The challenging aspects of the mechanical design and several of the more difficult production processes are discussed. In addition, the successes, failures, and lessons learned from acoustic and random vibration testing of a full-scale prototype instrument are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing a minimum-functionality neutron and gamma measurement instrument with a focus on authentication

During the design and construction of the Next-Generation Attribute-Measurement System, which included a largely commercial off-the-shelf (COTS), nondestructive assay (NDA) system, we realized that commercial NDA equipment tends to include numerous features that are not required for an attribute-measurement system. Authentication of the hardware, firmware, and software in these instruments is still required, even for those features not used in this application. However, such a process adds to the complexity, cost, and time required for authentication. To avoid these added authenticat ion difficulties, we began to design NDA systems capable of performing neutron multiplicity and gamma-ray spectrometry measurements by using simplified hardware and software that avoids unused features and complexity. This paper discusses one possible approach to this design: A hardware-centric system that attempts to perform signal analysis as much as possible in the hardware. Simpler processors and minimal firmware are used because computational requirements are kept to a bare minimum. By hard-coding the majority of the device's operational parameters, we could cull large sections of flexible, configurable hardware and software found in COTS instruments, thus yielding a functional core that is more straightforward to authenticate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical effects on clumped isotope thermometry: Comparison of a common sample set analyzed using multiple instruments, types of standards, and standardization windows

Carbonate clumped isotope geothermometry is being increasingly used in multiple disciplines in the geosciences. However, potential interlaboratory issues are arising from different standardization procedures that may contribute to the multiple Δ 47 -temperature calibrations reported in the literature. We investigate this issue by comparing a common temperature calibration sample set across three different mass spectrometers, using multiple standardization methods. The same temperature calibration sample set was analyzed on three different mass spectrometers. Several standardization methods were utilized, including the use of carbonate versus gas standards, and different types of background correction were applied to the raw data. All standardization types applied resulted in statistically indistinguishable Δ 47 -temperature slopes, with the exception of standardization calculations that did not correct for background effects. Some instruments and standardizations showed different intercepts relative to each other. The use of carbonate standards improved comparability between different instruments relative to gas standards. Our results show that background effects are the largest factor potentially affecting Δ 47 results, and there may be an improvement in interlaboratory precision using carbonate standards. Critically, all techniques used for standardizing Δ 47 results converge on a common slope as long as background effects are properly corrected. The use of carbonate standards is recommended as a component of standardization procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrument for stable high temperature Seebeck coefficient and resistivity measurements under controlled oxygen partial pressure

The transport properties of ceramic materials strongly depend on oxygen activity, which is tuned by changing the partial oxygen pressure (pO 2 ) prior to and during measurement. Within, we describe an instrument for highly stable measurements of Seebeck coefficient and electrical resistivity at temperatures up to 1300 K with controlled oxygen partial pressure. An all platinum construction is used to avoid potential materials instabilities that can cause measurement drift. Two independent heaters are employed to establish a small temperature gradient for Seebeck measurements, while keeping the average temperature constant and avoiding errors associated with pO 2 -induced drifts in thermocouple readings. Oxygen equilibrium is monitored using both an O 2 sensor and the transient behavior of the resistance as a proxy. A pO 2 range of 10 -25 –10 0 atm can be established with appropriate gas mixtures. Seebeck measurements were calibrated against a high purity platinum wire, Pt/Pt–Rh thermocouple wire, and a Bi 2 Te3 Seebeck coefficient Standard Reference Material. To demonstrate the utility of this instrument for oxide materials we present measurements as a function of pO 2 on a 1 % Nb-doped SrTiO 3 single crystal, and show systematic changes in properties consistent with oxygen vacancy defect chemistry. Thus, an approximately 11% increase in power factor over a pO 2 range of 10 -19 –10 -8 atm at 973 K for the donor-doped single crystals is observed.

36 MATERIALS SCIENCE↗

The LiteBIRD Satellite Mission: Sub-Kelvin Instrument

Inflation is the leading theory of the first instant of the universe. Inflation, which postulates that the universe underwent a period of rapid expansion an instant after its birth, provides convincing explanation for cosmological observations. Recent advancements in detector technology have opened opportunities to explore primordial gravitational waves generated by the inflation through “B-mode” (divergent-free) polarization pattern embedded in the cosmic microwave background anisotropies. If detected, these signals would provide strong evidence for inflation, point to the correct model for inflation, and open a window to physics at ultra-high energies. LiteBIRD is a satellite mission with a goal of detecting degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at the second Lagrange point with a 400 mm diameter telescope and 2622 detectors. It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to measure and subtract foregrounds. The US LiteBIRD team is proposing to deliver sub-Kelvin instruments that include detectors and readout electronics. A lenslet-coupled sinuous antenna array will cover low-frequency bands (40–235 GHz) with four frequency arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated horn array will cover high-frequency bands (280–402 GHz) with three types of single frequency detectors. The detectors will be made with transition edge sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by an adiabatic demagnetization refrigerator. The TES bolometers will be read out using digital frequency multiplexing with Superconducting QUantum Interference Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a single SQUID amplifier. Lastly, we report on the sub-Kelvin instrument design and ongoing developments for the LiteBIRD mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Die Stress Profiles during Powder Compaction using Instrumented Die

The radial stress profile in a cylindrical die during compaction of titanium (Ti) powder was investigated by experiments. The concept of an instrumented die was extended to design an enhanced instrumented die. Custom-made strain gage pins were used to measure the radial stress during powder compaction. The test fixture was designed to simulate double-action pressing. The measured die stress profile for Ti powder was compared with that for a commercially available iron (Fe) powder. The stress history shows that an appreciable residual stress remains in the die in the radial direction after the axial compaction stress is removed from the powder. Furthermore, the radial stress profile in the die, while under maximum axial compaction stress, is more uniform across the height of the Fe compact than that of the Ti compact. In addition, the residual stress profile in the die in the radial direction reduces symmetrically in both directions beyond the height of the compact for both powders. Finally, the Ti powder shows a significantly higher frictional coefficient at the maximum axial compaction stress, and consequently a higher maximum axial ejection stress than the Fe powder.

36 MATERIALS SCIENCE↗

A Review on Micro- and Nanoscratching/Tribology at High Temperatures: Instrumentation and Experimentation

High-temperature micro-/nanomechanics has attracted much interest over the last decade, primarily because of the urgent need to understand the mechanical and tribological properties of advanced engineering materials at micro-/nanoscale and the underlying physics controlling such properties at operationally relevant conditions. Recent years have subsequently witnessed the swift growth and development of new high-temperature micro- and nanoscratching/tribology instruments. Here, we present an overview of fundamental principles and developments in these instruments, discuss pertinent findings on the topic in detail, and outline current challenges and promising future directions in the field.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interleaved Distance-of-Flight Mass Spectrometry: A Simple Method to Improve the Instrument Duty Factor

Distance-of-Flight Mass Spectrometry (DOFMS) is a velocity-based, spatially dispersive MS technique in which ions are detected simultaneously along the plane of a spatially selective detector. In DOFMS, ions fly though the instrument and mass separate over a set period of time. The single flight time at which all ions are measured defines the specific m/z values that are detectable; the range of m/z values is dictated by the length of the spatially selective detector. However, because each packet of ions is detected at a single flight time, multiple groups of ions can fly through the instrument concurrently and be detected at a single detector. In this way, DOFMS experiments can be interleaved to perform several mass-separation experiments within a single DOF repetition period. Interleaved operation allows the orthogonal-acceleration region to be operated at a repetition rate higher than the reciprocal of the flight time, which improves the duty factor of the technique. In this paper, we consider the fundamental parameters of interleaved DOFMS and report first results.

Gundlach-Graham, Alexander↗

Measuring the Noble Metal and Iodine Composition of Extracted Noble Metal Phase from Spent Nuclear Fuel Using Instrumental Neutron Activation Analysis

Mass quantities of noble metal and iodine nuclides in the metallic noble metal phase extracted from spent fuel are measured using instrumental neutron activation analysis (NAA). Nuclide presence is predicted using fission yield analysis, and mass quantification is derived from standard gamma spectroscopy and radionuclide decay analysis. The nuclide compositions of noble metal phase derived from two dissolution methods, UO2 fuel dissolved in nitric acid and UO2 fuel dissolved in ammonium-carbonate and hydrogen-peroxide solution, are compared. Lastly, the implications of the rapid analytic speed of instrumental NAA are discussed in relation to potential nuclear forensics applications.

Palomares, R. I.↗

Parallel sorting algorithm classification: is manual instrumentation necessary?

Understanding parallel algorithms is crucial for accelerating scientific simulations on complex, distributed memory, high-performance computers. Modern algorithm classification approaches learn semantics directly from source code to differentiate between algorithms, however, accessing source code is not always possible. We can learn about parallel algorithms from observing their performance, as programs running the same algorithms and using the same hardware should exhibit similar performance characteristics. We present an approach to learn algorithm classes from parallel performance data directly in order to classify algorithms without access to the source code. We extend previous work to enable classifying parallel sorting algorithms using automatic instrumentation instead of requiring manual region annotations in the source code. In this work, we design and demonstrate a study for classification of parallel sorting algorithms using parallel performance data collected from automatic instrumentation, and evaluate the performance of our new methodology on classification. We leverage Caliper to collect the performance data, Thicket for our exploratory data analysis (EDA), and PyTorch and Scikit-learn to evaluate the effectiveness of random forests, support vector machines (SVMs), decision trees, neural networks, and logistic regressions on parallel performance data. Additionally, we study noise in parallel performance data, whether the removal of noise and pre-processing of the data is necessary to accurately classify parallel sorting algorithms, and determine the effectiveness of features created from performance data. In conclusion, we demonstrate classification accuracy for these five different models of up to 97.7% across four different parallel algorithm classes.

Algorithm Classification↗

Comparison of Ion Trajectories in Vacuum and Viscous Environments using SIMION: Insights for Instrument Design

Understanding ion trajectories in electrostatic and magnetic fields is necessary for designing many scientific instruments. Modeling of ion motion in vacuum has been possible for over a decade with SIMION software, which has been highly exploited to advance instrumentation, especially mass spectrometers. Simulations of ions within a viscous media, such as in ion mobility spectrometers, has only recently been possible with the advent of the statistical dynamics simulation user program for SIMION 7.0. Key insights into the difference in ion behavior in vacuum and viscous environments are reported for electrostatic refraction, motion through grids, and magnetic fields. The loss of kinetic energy limits options for controlling ion motion in viscous conditions. For refraction, only accelerating methods (converging or diverging) are possible in viscous regimes. Motion of ions around wires in grids also has more severe consequences in viscous conditions than in vacuum. For magnetic fields, a “rule-of-thumb” that an ion must be able to complete ~25 % of its cyclotron radius between collisions for the magnetic field to affect the ion motion. The difference in ion behavior is governed by the fact that kinetic energy of ion motion is retained in vacuum, but lost to collisions with the bath gas in viscous atmospheres. Because of the loss of kinetic energy, ion behavior in electrostatic and magnetic fields under viscous conditions is dramatically different than in vacuum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of hot tearing of A206 aluminum alloy using Instrumented Constrained T-shaped Casting method

The hot tearing susceptibility of A206 aluminum alloy was investigated using Instrumented Constrained T-shaped Casting method and the effect of the casting temperature on hot tearing was studied. The Instrumented Constrained T-shaped Casting apparatus enabled real-time measurements of the contraction load developed in the casting and the temperature variations during solidification as a function of time. Critical temperatures and points during solidification of the castings were extracted from these data. The contraction load developed at the coalescence point of the castings was identified as a comparative criterion for predicting the hot tearing susceptibility of the alloys which could be utilized even when no visual tearing had occurred. The results showed that hot tearing susceptibility increased with the casting temperature. This was associated with reduced cooling rate, increased solute segregation and more localized hot spot formation at the T-junction area. Increase in the casting temperature also increased the grain size which may in turn have affected the initiation of the hot tears. The visual observations were further validated with radiographic tests.

36 MATERIALS SCIENCE↗

Determination of total plutonium content in spent nuclear fuel assemblies with the differential die-away self-interrogation instrument

As a part of the Next Generation Safeguards Initiative Spent Fuel project, we simulate the response of the Differential Die-away Self-Interrogation (DDSI) instrument to determine total elemental plutonium content in an assayed spent nuclear fuel assembly (SFA). We apply recently developed concepts that relate total plutonium mass with SFA multiplication and passive neutron count rate. In this work, the multiplication of the SFA is determined from the die-away time in the early time domain of the Rossi-Alpha distributions measured directly by the DDSI instrument. Here, we utilize MCNP to test the method against 44 pressurized water reactor SFAs from a simulated spent fuel library with a wide dynamic range of characteristic parameters such as initial enrichment, burnup, and cooling time. Under ideal conditions, discounting possible errors of a real world measurement, a root mean square agreement between true and determined total Pu mass of 2.1% is achieved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Concepts, Instruments, and Model Systems that Enabled the Rapid Evolution of Surface Science

Over the past forty years, surface science has evolved to become both an atomic scale and a molecular scale science. Gerhard Ertl's group has made major contributions in the field of molecular scale surface science, focusing on vacuum studies of adsorption chemistry on single crystal surfaces. In this review, we outline three important aspects which have led to recent advances in surface chemistry: the development of new concepts, in situ instruments for molecular scale surface studies at buried interfaces (solid-gas and solid-liquid), and new model nanoparticle surface systems, in addition to single crystals. Combined molecular beam surface scattering and low energy electron diffraction (LEED)- surface structure studies on metal single crystal surfaces revealed concepts, including adsorbate-induced surface restructuring and the unique activity of defects, atomic steps, and kinks on metal surfaces. We have combined high pressure catalytic reaction studies with ultra high vacuum (UHV) surface characterization techniques using a UHV chamber equipped with a high pressure reaction cell. New instruments, such as high pressure sum frequency generation (SFG) vibrational spectroscopy and scanning tunneling microscopy (STM) which permit molecular-level surface studies have been developed. Tools that access broad ranges of pressures can be used for both the in situ characterization of solid-gas and solid-liquid buried interfaces and the study of catalytic reaction intermediates. The model systems for the study of molecular surface chemistry have evolved from single crystals to nanoparticles in the 1-10 nm size range, which are currently the preferred media in catalytic reaction studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗