Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOS ALAMOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Physics design of the next-generation spallation neutron target-moderator-reflector-shield assembly at LANSCE

Here, we discuss the physics design of the next-generation spallation neutron target-moderator-reflector-shield (TMRS) assembly for the Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) at the Los Alamos Neutron Science Center (LANSCE). We developed this TMRS to improve the neutronic performance of the Lujan Center in the intermediate energy range (keV–MeV) enabling a variety of new nuclear physics experiments, as well as increasing the quality of the ongoing experiments. The results of our Monte Carlo optimization study indicate that the new TMRS will generate keV–MeV neutrons with higher intensity and improved time resolution. At the same time, the new design largely maintains its current performance in the cold and thermal ranges supporting materials research. In this article we show that the new TMRS has the potential to enhance the Lujan Center’s experimental capability in a wider interval of energies – cold to intermediate – after its scheduled installation in 2020.

43 PARTICLE ACCELERATORS↗

Experimental improvement of 750-keV H - beam transport at LANSCE Accelerator Facility

The 750-keV low-energy beam transport of the Los Alamos Neutron Science Center (LANSCE) linac consists of two independent beam lines that facilitate simultaneous injection of H + and H - beams into the linear accelerator. The efficiency of beam transport within this structure is largely controlled by the effects of space-charge neutralization. In this study, we report a series of experiments that were performed to determine the level, as well as the required timescale for the onset of beam space charge neutralization. Measurements performed along the structure indicate significant variation of neutralized space charge beam dynamics in the beamline, and the corresponding results have been used to substantially improve beam transport with diminished beam losses. Finally, the analysis of experimental and theoretical data employed in optimization of beam performance in the transport line is discussed.

43 PARTICLE ACCELERATORS↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of the DANCE thermal neutron beam using sodium activation

The calculation of the neutron capture cross section as a function of energy in the thermal range requires a precise knowledge of the absolute neutron flux. In this paper a method of calibrating a thermal neutron beam using the controlled activation of sodium is described. Here, the method is applied to the FP-14 Time Of Flight neutron beam line at the Los Alamos Neutron Science Center to calibrate the beam to an uncertainty level of ±5 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of proton-induced radiation damage on CLYC and CLLBC performance

Cerium-doped Cs 2 LiYCl 6 (CLYC) and Cs 2 LiLaBr x Cl 6-x (CLLBC) are scintillators in the elpasolite family that are attractive options for resource-constrained applications due to their ability to detect both gamma rays and neutrons within a single volume. Space-based detectors are one such application, however, the radiation environment in space can over time damage the crystal structure of the elpasolites, leading to degraded performance. We have exposed 4 samples each of CLYC and CLLBC to 800 MeV protons at the Los Alamos Neutron Science Center. The samples were irradiated with a total number of protons of 1.3 x 10 9 , 1.3 x 10 10 , 5.2 x 10 10 , and 1.3 x 10 11 , corresponding to estimated doses of 0.14, 1.46, 5.82, and 14.6 kRad, respectively on the CLYC samples and 0.14, 1.38, 5.52, and 13.8 kRad, respectively on the CLLBC samples. Here, we report the impact these radiation doses have on the light output, activation, gamma-ray energy resolution, pulse shapes, and pulse-shape discrimination figure of merit for CLYC and CLLBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancement of LANSCE accelerator facility as a 1-MW Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is considered to be a testbed for scientific understanding of material degradation in future nuclear fusion reactors (Zinkle and Moeslang, 2013; Summary Report on the FPNS Workshop, 2018; Pitcher et al., 2019). The primary mission of FPNS is to provide a damage rate in iron samples of 8-11 dpa/calendar year with He/dpa ratio of 10 appm in irradiation volume of 50 cm 3 or larger with irradiation temperature 300–1000 °C and flux gradient less than 20%/cm in the plane of the sample. The Los Alamos Neutron Science Center (LANSCE) is an attractive candidate for the FPNS project. The Accelerator Facility was designed and operated for an extended period as a 0.8-MW Meson Factory. The existing setup of the LANSCE accelerator complex can nearly fulfill requirements of the fusion neutron source station. The primary function of the upgraded accelerator systems is the safe and reliable delivery of a 1.25-mA continuous proton beam current at 800-MeV beam energy from the switchyard to the target assembly to create 1 MW power of proton beam interacting with a solid tungsten target. The present study describes existing accelerator setup and further development required to meet the needs of FPNS project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New evaluation on angular distributions and energy spectra for neutron-induced charged-particle measurements

Recent development on neutron-induced charged particle reaction measurements can provide high-quality double differential cross sections at Los Alamos Neutron Science Center. With newly measured cross section data, we found lacking nuclear outputs for neutron-induced charged particle reactions in the latest ENDF/B-VIII.0 library, when compared with Monte Carlo simulations. Here, this paper presents how we improved the missing angular distributions and energy spectra for these reactions and the validation of our new evaluations with the measurements performed with the LENZ instrument at LANSCE. The impact of this additional evaluation is demonstrated by comparing the MCNP simulations with the LENZ experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton irradiation damage and annealing effects in ON Semiconductor J-series silicon photomultipliers

Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However, the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. As such, to study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of 1.68 × 10 9 , 1.73 × 10 10 , 6.91 × 10 10 , and 1.73 × 10 11 protons cm –2 , and their corresponding estimated doses of 0.15, 1.55, 6.19, and 15.5 kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture of UO 2 targets prepared by spin-coating assisted combustion synthesis

Two uranium dioxide (UO 2 ) targets of (414 ± 23) nm and (1092 ± 93) nm thicknesses were prepared on 6061 aluminum alloy and puratronic grade aluminum backing materials. The targets were deposited with a novel method combining spin coating and solution combustion synthesis (SCS). The target layers consisted of small (3–7 nm) UO 2 grains and uniformly distributed ultra-small (1–3 nm) pores. The prepared targets were tested at the Los Alamos National Laboratory’s LANSCE facility for neutron irradiation damage and suitability for neutron capture experiments. The samples showed no signs of target material loss after the irradiation. However, irradiation caused a significant increase in the grain size (4–10 nm), as well as upward mass diffusion and coalescence of the pores due to the thermal spikes. The magnesium in the aluminum 6061 alloy backing also diffused into the UO 2 layer during neutron irradiation. The structural changes in the target after the irradiation do not affect the data from neutron capture. As a result, the new method can be used more broadly to prepare other actinide targets for nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the new Ultracold Neutron beamline at the LANL UCN facility

The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey’s method of separated oscillatory fields to search for a nEDM. Here, in this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate a sufficient number of stored polarized UCN to achieve a statistical uncertainty of δd n = 2 x 10 -27 e cm in 5 calendar years of running. We also present an analytical model describing data that provides a simple parameterization of the input UCN energy spectrum on the new beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗