Search NASA⌕ Search

SEARCH · Search NASA

Results for “Large deviations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

The Observed Inefficiency of Explosions to Produce Large Aftershocks: Båth’s Law for Explosions is 2.5

Underground explosions are observed to produce fewer and smaller aftershocks than similar size earthquakes. The seismic magnitude difference $Δm_x$ between an explosion and its largest aftershock is an expression of Båth’s law for explosions. Based on an analysis of a compilation of aftershock studies from Soviet testing at the Semipalatinsk test site in Kazakhstan and observations from American testing at the Nevada National Security Site (NNSS), here we find that the average magnitude difference for explosions $\overline{Δm_x}$ is about 2.5. Based on the NNSS data, two standard deviations of $Δm_x$ is about 1.5. In all the cases studied, from ton to megaton yield, from shallow to overburied depth, and chemical or nuclear source, no explosion aftershock has been larger than the explosion that preceded it. In fact, the two events at the NNSS with the largest aftershock magnitudes relative to the explosion are associated with the collapse of the cavity created by the explosion. This is similar to observations from North Korean testing at the Punggye-ri Test Site, where the largest seismic event following the test is attributed to the collapse after the 2017 explosion and is from 0.8 to 2 magnitude units less than the mainshock.

58 GEOSCIENCES↗

Search for Higgs boson production in association with a high-energy photon via vector-boson fusion with decay into bottom quark pairs at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search is presented for the production of the Standard Model Higgs boson in association with a high-energy photon. With a focus on the vector-boson fusion process and the dominant Higgs boson decay into b-quark pairs, the search benefits from a large reduction of multijet background compared to more inclusive searches. Results are reported from the analysis of 132 fb –1 of pp collision data at $\sqrt{s}$ = 13 TeV collected with the ATLAS detector at the LHC. The measured Higgs boson signal yield in this final-state signature is 1.3 ± 1.0 times the Standard Model prediction. The observed significance of the Higgs boson signal above the background is 1.3 standard deviations, compared to an expected significance of 1.0 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of $t\bar{t}γγ$ production at $\sqrt{s} = 13$ TeV with the ATLAS detector

This paper presents the first observation of top-quark pair production in association with two photons ($t\bar{t}γγ$). The measurement is performed in the single-lepton decay channel using proton-proton collision data collected by the ATLAS detector at the Large Hadron Collider. The data correspond to an integrated luminosity of 140 fb −1 recorded during Run 2 at a centre-of-mass energy of 13 TeV. The $t\bar{t}γγ$ production cross section, measured in a fiducial phase space based on particle-level kinematic criteria for the lepton, photons, and jets, is found to be 2.42$_{− 0.53}^{+ 0.58}$ fb , corresponding to an observed significance of 5.2 standard deviations. Additionally, the ratio of the production cross section of $t\bar{t}γγ$ to top-quark pair production in association with one photon is determined, yielding (3.30$_{− 0.65}^{+ 0.70}$) × 10 −3 .

Aad, G. (ORCID:0000000266654934)↗

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

This study presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon recombination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2 and 16 keV with 3 H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence for Electroweak Production of W ± W ± j j in p p Collisions at s = 8 TeV with the ATLAS Detector

CERN-LHC. We present the first study of W+- W+- JET JET, same-electric-charge diboson production in association with two jets, using 20.3 fb^{-1} of proton-proton collision data at sqrt(s) = 8 TeV recorded by the ATLAS detector at the Large Hadron Collider. Events with two reconstructed same-charge leptons (E+- E+-, E+- MU+-, and MU+- MU+-) and two or more jets are analyzed. Production cross sections are measured in two fiducial regions, with different sensitivities to the electroweak and strong production mechanisms. First evidence for W+- W+- JET JET production and electroweak-only W+- W+- JET JET production is observed with a significance of 4.5 and 3.6 standard deviations respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructural characterization of in situ MXCT images of high density foams under large strains

Foams are used in numerous applications, such as vibration damping and energy mitigation (e.g., packaging and helmets), wherein their mechanical properties are of critical importance. A typical compressive response of a high density elastomeric foam, shown in Fig 1, generally contains three regions of interest: (I) a linear-elastic region, governed by strut bending; (II) a relatively flat, or slowly increasing stress-strain response, accompanied by strut buckling and the localized collapse of pores; and (III) an exponentially increasing stress-strain curve wherein the collapse of the pore matrix leads to densification. Two material properties of interest, upon which considerable research has focused are the foam's Young's modulus, E{sub f}, defined as the slope of the stress-strain response in region I, and the collapse stress, {sigma}{sub f}, defined as the stress at which the response begins to deviate from linearity. It has been observed [1, 2, 3] that Young's modulus and the collapse stress are dependent on the material properties of the strut material and the non-dimensional relative-density of the foam, {rho}* = {rho}{sub f}/{rho}{sub m}, where {rho}{sub r} is the gross density of the foam and {rho}{sub m} is the density of the strut, or matrix, material. For foam of low relative-density, i.e, {rho}* < 0.1, the collapse stress and Young's modulus obey the relations {sigma}{sub c}/E{sub m} {proportional_to} ({rho}*){sup m} and E{sub f}/E{sub m} {proportional_to} ({rho}*){sup n} where E{sub m} is Young's modulus of the strut material and the bounds on the parameters m and n are 0.05 {le} m {le} 0.2 and 1 {le} n {le} 4 [4]. For open-celled foams, n = 2, whereas for closed-celled foams, n = 3. Theoretically, n = 1 for foams with an ''ideal strut'' configuration [6]. Foams of high relative-density ({rho}* > 0.1) require correcting terms to account for the axial contributions of the ''thick'' struts [5]. The above equations relate important foam properties to the relative-density of the foam; however, there exists a gap in the understanding of how the foam microstructure affects the mechanical response of the foam. This is due in large part to the difficulty of characterizing foam structures in 3D, especially foams of high relative-density. Most elastomeric foams are manufactured by the introduction of a gas into a cross-linking polymer. The developing foam microstructure has a complex dependence on the polymer viscosity and rate of polymerization, resulting in a randomly arranged pore structure with a large distribution of pore sizes. One approach is to characterize foam microstructures solely in terms of the cross-sectional shape and vector arrangement of the strut matrix, since it is this matrix that supports the stresses upon loading of the foam; yet as the density of a foam is increased, the very definition of what constitutes a strut brakes down. Another, perhaps easier to visualize, characterization of foam microstructure can come from a description of the pore shape and arrangement. Given the random nature of the microstructures of blown foam, both approaches are useful and valid. This paper describes our work aimed at linking the mechanical response and microstructural evolution of high relative-density foam as it undergoes large deformation. This work consists of several inter-related parts, including (i) measuring the compressive stress-strain response, as illustrated in Fig. 1, (ii) obtaining in situ micro X-ray computed tomography (MXCT) images of high relative-density foams undergoing large strains, and (iii) developing mathematical, computer aided, methodologies to perform image analysis and calculations of parameters that characterize the pores and struts. By using MXCT, a non-invasive technique for imaging the internal structure of materials, we are able to observe, internally, individual struts and pores as they undergo large deformation. Here we describe our computer aided image analysis methodologies and present examples of their application to the MXCT images of foams. Operations of the computer program include noise removal (smoothing), thresholding [7], edge detection [8], distance transformation [9, 10], pore detection via a Hough transformation [11], and skeletonization [12]. Strut parameters, such as the strut cross-sectional area and strut arrangement, are calculated from a skeleton-based model of the MXCT images. The Hough transform is a feature detection method used primarily in image analysis applications. We use this transform to detect and calculate pore parameters, such as pore arrangement and pore size distribution. The experiments and calculations are performed in order to develop data for the formulation of theory that links foam mechanical behavior specifically to the microstructure of high relative-density foams, not just simply to the relative-density of the foam.

36 MATERIALS SCIENCE↗

Heat capacity of Mg 3 Sb 2 , Mg 3 Bi 2 , and their alloys at high temperature

The thermoelectric figure of merit reported for n-type Mg 3 (Sb,Bi) 2 compounds has made these materials of great engineering significance, increasing the need for accurate evaluations of their thermal conductivity. Thermal conductivity is typically derived from measurements of thermal diffusivity and determination of the specific heat capacity. The uncertainty in this method (often 10% or more) is frequently attributed to measurement of heat capacity such that estimated values are often more accurate. Inconsistencies between reported thermal conductivity of Mg 3 (Sb,Bi) 2 compounds may be attributed to the different values of heat capacity measured or used to calculate thermal conductivity. The high anharmonicity of these materials can lead to significant deviations at high temperatures from the Dulong-Petit heat capacity, which is often a reasonable substitute for measurements at high temperatures. Herein, a physics-based model is used to assess the magnitude of the heat capacity over the entire temperature range up to 800 K. The model agrees in magnitude with experimental low-temperature values and reproduces the linear slope observed in high-temperature data. Owing to the large scatter in experimental values of high-temperature heat capacity, the model is likely more accurate (within ±3%) than a measurement of a new sample even for doped or alloyed materials. It is found that heat capacity for the solid solution series can be simply described (for temperatures: 200K≤T≤800K ) by the polynomial equation: c p [Jg –1 K –1 ]=3NR/M W (1 + 1.3 × 10 –4 T – 4 × 10 3 T –2 ), where 3 NR = 124.71 J mol –1 K –1 , M W is the molecular weight [gmol –1 ] of the formula unit being considered, and T is temperature in K . This heat capacity is recommended to be a standard value for reporting and comparing the thermal conductivity of Mg 3 (Sb,Bi) 2 including doped or alloyed derivatives. Furthermore, a general form of the equation is given which can be used for other material systems

36 MATERIALS SCIENCE↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Markov state models from short non-equilibrium simulations—Analysis and correction of estimation bias

To begin, many state-of-the-art methods for the thermodynamic and kinetic characterization of large and complex biomolecular systems by simulation rely on ensemble approaches, where data from large numbers of relatively short trajectories are integrated. In this context, Markov state models (MSMs) are extremely popular because they can be used to compute stationary quantities and long-time kinetics from ensembles of short simulations, provided that these short simulations are in “local equilibrium” within the MSM states. However, over the last 15 years since the inception of MSMs, it has been controversially discussed and not yet been answered how deviations from local equilibrium can be detected, whether these deviations induce a practical bias in MSM estimation, and how to correct for them. In this paper, we address these issues: We systematically analyze the estimation of MSMs from short non-equilibrium simulations, and we provide an expression for the error between unbiased transition probabilities and the expected estimate from many short simulations. We show that the unbiased MSM estimate can be obtained even from relatively short non-equilibrium simulations in the limit of long lag times and good discretization. Further, we exploit observable operator model (OOM) theory to derive an unbiased estimator for the MSM transition matrix that corrects for the effect of starting out of equilibrium, even when short lag times are used. Finally, we show how the OOM framework can be used to estimate the exact eigenvalues or relaxation time scales of the system without estimating an MSM transition matrix, which allows us to practically assess the discretization quality of the MSM. Applications to model systems and molecular dynamics simulation data of alanine dipeptide are included for illustration. The improved MSM estimator is implemented in PyEMMA of version 2.3.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling dark- and light-induced crystal structures and single-crystal optical absorption spectra of ruthenium-based complexes that undergo SO 2 -linkage photoisomerization

A family of coordination complexes of the type [Ru(SO 2 )(NH 3 ) 4 X] m+ Y n – (m, n = 1 or 2) exhibit optical switching capabilities in their single-crystal states. This striking effect is caused by the light-induced formation of SO 2 -linkage photoisomers, which are metastable if kept at suitably cool temperatures. We modeled the dark- and light-induced states of these large crystalline complexes via plane-wave (PW)- and molecular-orbital (MO)-based density functional theory (DFT) and time-dependent DFT in order to calculate their structural and optical properties; the calculated results are compared with experimental data. We show that the PW-DFT-based periodic models replicate the structural properties of these complexes more effectively than the MO-DFT-based molecular-fragment models, observing only small deviations in key bond lengths relative to the experimentally derived crystal structures. The periodic models were also found to more effectively simulate trends seen in experimental optical absorption spectra, with optical absorbance and coverage of the visible region increasing with the formation of the photoinduced geometries. The contribution of the metastable photoisomeric species more heavily focuses on the lower-energy end of the spectra. Spectra generated from the molecular-fragment models are limited by the geometry of the fragment used and the number of excited-state roots considered in those calculations. In general, periodic models outperform the molecular-fragment models owing to their ability to better appreciate the periodic phenomena that are present in these crystalline materials as opposed to MO approaches, which are finite methods. We thus demonstrate that PW-DFT-based periodic models should be considered as a more than viable method for simulating the optical and electronic properties of these single-crystal optical switches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bose-Einstein condensation phenomenology in systems with repulsive interactions

The role of repulsive interactions in statistical systems of Bose particles is investigated. Three different phenomenological frameworks are considered: A mean-field model, an excluded volume model, and a model with a medium-dependent effective mass. All three models are tuned to yield similar equations of state, with only minor deviations from the ideal Bose gas at small chemical potentials. Our analysis indicates, however, that these models lead to qualitatively different results for the Bose-Einstein condensation phenomenon. We discuss the different aspects of this phenomenon, namely, an onset of the Bose-Einstein condensation, particle number fluctuations, and a behavior of the Bose condensate. The obtained results can be helpful for interpreting the lattice QCD data at small temperature and large isospin chemical potential and the data on multiple pion production in high-energy nuclear collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anisotropic Kantowski-Sachs universe from gravitational tunneling and its observational signatures

In a landscape of compactifications with different numbers of macroscopic dimensions, it is possible that our Universe has nucleated from a vacuum where some of our four large dimensions were compact while other, now compact, directions were macroscopic. From our perspective, this shapeshifting can be perceived as an anisotropic background spacetime. As an example, we present a model where our Universe emerged from a tunneling event which involves the decompactification of two dimensions compactified on the two-sphere. In this case, our Universe is of the Kantowski-Sachs type and therefore homogeneous and anisotropic. We study the deviations from statistical isotropy of the cosmic microwave background induced by the anisotropic curvature, with particular attention to the anomalies. The model predicts a quadrupolar power asymmetry with the same sign and acoustic oscillations as found by the Wilkinson Microwave Anisotropy Probe. The amplitude of the effect is however too small given the current estimated bound on anisotropic curvature derived from the quadrupole.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Introducing a multiscale feature integration network for inpainting with applications to enhanced CMB map reconstruction

We introduce a novel neural network, SkyReconNet, which combines the expanded receptive fields of dilated convolutional layers along with standard convolutions, to capture both the global and local features for reconstructing the missing information in an image. We implement our network to inpaint the masked regions in a full-sky cosmic microwave background (CMB) map. Inpainting CMB maps is a particularly formidable challenge when dealing with extensive and irregular masks, such as galactic masks which can obscure substantial fractions of the sky. The hybrid design of SkyReconNet leverages the strengths of standard and dilated convolutions to accurately predict CMB fluctuations in the masked regions by effectively utilizing the information from surrounding unmasked areas. During training, the network optimizes its weights by minimizing a composite loss function that combines the structural similarity index measure (SSIM) and mean squared error (MSE). SSIM preserves the essential structural features of the CMB, ensuring an accurate and coherent reconstruction of the missing CMB fluctuations, while MSE minimizes the pixelwise deviations, thus enhancing the overall accuracy of the predictions. The predicted CMB maps and their corresponding angular power spectra align closely with the targets, achieving the performance limited only by the fundamental uncertainty of cosmic variance. The network’s generic architecture enables application to other physics-based challenges involving data with missing or defective pixels, systematic artifacts, etc. In conclusion, our results demonstrate its effectiveness in addressing the challenges posed by large irregular masks, offering a significant inpainting tool not only for CMB analyses but also for image-based experiments across disciplines where such data imperfections are prevalent.

Cosmic microwave background↗

SU-E-I-34: Evaluating Use of AEC to Lower Dose for Lung Cancer Screening CT Protocols

Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD) image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of GEp/GMp to high Q2 and search for 2{gamma} contribution in elastic ep at Jefferson Lab

The ratio, μpGEp/GMp, where μp is the proton magnetic moment, has been measured extensively over the last decade at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of transverse to longitudinal polarizations components of the recoiling proton in elastic electron-proton scattering. The polarization transfer results are of unprecedented high precision and accuracy, due in large part to the small systematic uncertainties associated with the experimental technique. Prior to these measurements, the form factors were empirically observed to exhibit dipole forms, such that μpGEp/GMp ≈ 1 over all regions of momentum transfer studied. With the Hall A results confirming that the ratio μpGEp/GMp shows a steady decrease below unity as a function of Q2, beginning around Q2 ≈ 1 GeV2, discussions revolving around the implication of this deviation from dipole behavior for the structure of the proton have been accompanied by renewed experimental interest in these elastic form factors. Starting in the fall of 2007, two new experiments, GEp-III and GEp-2γ in Hall C at JLab, measured the form factor ratio, GEp/GMp; the GEp-III experiment pushed the highest Q2 limit from 5.6 to 8.49 GeV2, with intermediate points at 5.2 and 6.8 GeV2, and the GEp-2γ experiment measured the ratio in three different kinematics at the constant value Q2=2.5 GeV2, by changing beam energy and detector angles. Preliminary results from both experiments are reported.

43 PARTICLE ACCELERATORS↗

Inexact convex relaxations for AC optimal power flow: Towards AC feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. Here, this paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 test cases. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Localization Accuracy and Immobilization Effectiveness of a Stereotactic Body Frame for a Variety of Treatment Sites

Purpose: The purpose of this study was to analyze the pretreatment setup errors and intrafraction motion using cone beam computed tomography (CBCT) for stereotactic body radiation therapy patients immobilized and localized with a stereotactic body frame for a variety of treatment sites. Methods and Materials: Localization errors were recorded for patients receiving SBRT for 141 lung, 29 liver, 48 prostate, and 45 spine tumors representing 1005 total localization sessions. All patients were treated in a stereotactic body frame with a large custom-molded vacuum pillow. Patients were first localized to the frame using tattoos placed during simulation. Subsequently, the frame was aligned to the room lasers according to the stereotactic coordinates determined from the treatment plan. Every patient received a pretreatment and an intrafraction CBCT. Abdominal compression was used for all liver patients and for approximately 40% of the lung patients to reduce tumor motion due to respiration. Results: The mean ± standard deviation pretreatment setup errors from all localizations were −2.44 ± 3.85, 1.31 ± 5.84, and 0.11 ± 3.76 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean pretreatment localization results among all treatment sites were not significantly different (F test, P<.05). For all treatment sites, the mean ± standard deviation intrafraction shifts were 0.33 ± 1.34, 0.15 ± 1.45, and −0.02 ± 1.17 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean unidimensional intrafraction shifts were statistically different for several of the comparisons (P<.05) as assessed by the Tukey-Kramer test. Conclusions: Despite the varied tumor locations, the pretreatment mean localization errors for all sites were found to be consistent among the treatment sites and not significantly different, indicating that the body frame is a suitable immobilization and localization device for a variety of tumor sites. Our pretreatment localization errors and intrafraction shifts compare favorably with those reported in other studies using different types of immobilization devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗