Search NASA⌕ Search

SEARCH · Search NASA

Results for “Paper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Radiogenic Risk in Normal Tissues of Cancer Patients Receiving Radiotherapy - Paper 64

Because of its effectiveness in causing lethal damage to cancer cells and yielding local tumor control, radiotherapy is an important component of most curative cancer treatments. In radiotherapy, very high doses of radiation are delivered deliberately to patients, with the goal of conforming a prescribed radiation dose to the clinical target and nearby tissues. In this process, radiation absorbed dose damages organs and tissues both from therapeutic radiation within the treatment fields and stray radiation outside the treatment fields. Stray radiation originates either in the treatment unit or in the patient and has no known therapeutic benefit. Over the past decade, our understanding of these exposures and secondary effects has grown immensely. In this presentation, we will discuss the radiogenic risks in normal tissues of cancer patients receiving radiotherapy, with a particular focus on late effects and what is being done to reduce the risks. Long-term epidemiological studies of patients or others who have been exposed to radiation are essential for understanding the relationship between effective dose and the risk of late effects. However, in the case of epidemiological studies for patients exposed to radiation, many of the techniques used to deliver the radiation (and often the chemotherapy used) are obsolete. The results of these studies are further complicated by the direct or synergistic effects of chemotherapy and variations in genetic susceptibility, which are very difficult to take into account or control statistically. This underscores the value of predictive dosimetric studies that rely on risk models and can be done immediately without the need for long-term follow up, for example in silico clinical trials. In this presentation, we will discuss more comprehensively the risks of radiogenic late effects, specifically with regard to cancer patients receiving radiotherapy, including recent epidemiological and predictive dosimetric studies. Methods of reducing these risks will also be presented. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of the Geant4 Simulation Toolkit to Medical Physics - Paper 65

We show how the Geant4 Simulation Toolkit, originally developed for High Energy Physics, has been applied to a wide variety of challenging applications in medical physics. As the authors are mainly responsible for providing assistance to Geant4 users in North America, they draw on examples from the North American experience, but the conclusions can be generalized to the Geant4 medical user community worldwide. Geant4 is already heavily used in all areas of medical physics, from external beam therapy to brachytherapy to interventional nuclear medicine and medical imaging. As the complexity of medical physics studies continues to increase, requiring greater accuracy of modeling, and an increase in 4D capabilities (component motion and time-varying electric and magnetic fields), Geant4 use will only expand. The openness of the HEP community (keeping Geant4 well supported, open and free) is greatly appreciated by the medical and aerospace communities. The democratic nature of Geant4's governance (that decision-making rests with a technical steering board elected by the collaborators) has given outside communities the confidence to invest their energies in Geant4 (shown them that it is worth the time investment to become expert users). Geant4's latest key area of focus, moving to multithreaded operation, is seen as a huge boon to the medical users (where precision simulations often require billions of primary particles). Another recent key area of Geant4, increasing automated systems for unit and end-to-end testing, is also seen as extremely valuable to these non-HEP communities. Innovations from HEP and aerospace will benefit medical applications, and vice versa. Geant4 can expect increasing resources to be provided by the medical physics community, pooling resources to the benefit of all users. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron and Photon Background Measurements at the Spallation Neutron Source Facility - Paper 67

The Spallation Neutron Source facility is a short-pulsed spallation source for condensed matter research using slow neutron scattering. Neutron beams with useful energies ranging from 0.1 meV to 10 eV are brought from a target-moderator-reflector assembly down neutron beamlines to scatter from a variety of materials under study. As of early 2014, SNS routinely provides 1.4 MW (time-averaged) proton power at around 940 MeV to a mercury spallation target at 60 Hz in sub-microsecond pulses. In nearly all cases, the pulsed nature of the neutron source is used, via time-of-flight techniques, to precisely identify the energy of each neutron detected. These neutrons are frequently of such low energy, and consequent slow velocity, that they are not detected until several additional accelerator pulses have taken place. A time-dependent background feature, commonly called the 'prompt pulse,' can contaminate the recorded data. This prompt pulse arises in part from fast and high-energy neutrons and photons produced during the various source reactions, and appears at the same apparent time as the proton pulse striking the target (that is, with negligible time-of-flight delay), often obscuring the data of interest in the individual experiment. We describe here measurements of the fast and high-energy neutron and photon background around the SNS neutron scattering instruments appearing in time with the SNS accelerator pulse structure. Our measurements to date indicate that the liquid scintillator array we have deployed can satisfactorily function in the SNS environment and provide neutron-photon discriminated time/energy spectra of background sources contribution to observed, problematic SNS scattering instrument backgrounds. We will continue measurements and analysis to provide unfolded neutron energy spectra, and through longitudinal studies correlate observed changes in those spectra to external changes at SNS. (authors)

43 PARTICLE ACCELERATORS↗

Analysis of Archived Prompt Pulse Data from the SNS HYSPEC Instrument - Paper 68

This is an investigation by the Neutronics team at the Spallation Neutron Source (SNS) to understand the Hybrid-Spectrometer (HYSPEC) pulsed background problem and ultimately lend qualitative insight toward future shielding considerations. The archived user data from HYSPEC was accessed and manipulated via Mantidplot. Algorithms have been written to identify the background feature, or 'prompt pulse', in these data files and how it fluctuates as a function of time. Correlations between these fluctuations and external/internal physical changes are being analyzed in an attempt to model the behavior of the pulsed background in the SNS target building. Understanding the contributing factors of the background may help mitigate current effects as well as potential effects in future target facilities. This information is initially being used to indicate how the local shielding arrangements and general geometry of the target building and/or greater facility affect the prompt pulse as received by HYSPEC. Additionally, this better understanding of the pulsed background will continue to help our team lend increasingly accurate advice concerning future shielding improvements, minimization of prompt pulse features in the HYSPEC data, other inelastic instruments in the current target facility and suggestions for second target station planning. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Hybrid Diffusion-Transport Spatial Homogenization Method to a Pressurized Water Reactor Benchmark Problem - Paper 70

The recently developed Hybrid Diffusion-Transport Spatial Homogenization (DTH) method was previously tested on a benchmark problem typical of a boiling water reactor. In this summary, the DTH method is tested in a 1-D benchmark problem typical of a pressurized water reactor. The method recreates the heterogeneous flux to within 1% average flux error and 34 pcm eigenvalue error in half the time as a heterogeneous transport calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument - Paper 75

High-power laser interaction with targets in vacuum at high laser irradiance levels can generate plasma and, consequently, create ionizing radiation hazards. The theory for ionizing radiation generation from laser-plasma interaction is complicated. The basics of theory and phenomenology are available qualitatively. However, the ionizing radiation yields associated with laser-plasma interaction have not been well quantified. Based on the theoretical analysis and review of the published reports and measurement data, SLAC National Accelerator Laboratory (SLAC) developed an analytic model to estimate conservatively the electron temperature and photon radiation yield (Sv/J) of a laser pulse hitting a solid target at 1 m as a function of laser irradiance between 10{sup 15} and 10{sup 21} W/cm{sup 2}. Ionizing radiation measurements from high-intensity laser-induced plasma interactions on solid targets inside the Al-walled vacuum chamber of the LCLS MEC instrument at SLAC were conducted using passive and active detectors at irradiance between 3x10{sup 16} and 6x10{sup 17} W/cm{sup 2}. Each run of the more than 20 runs had a unique set of laser, optic and target conditions with laser pulses rastering over the target surface mainly perpendicularly at a fixed irradiance. Significant effort was made in characterizing the laser irradiance values for each configuration of laser, focusing mirror, and target; four irradiances with targets of Au foils and copper plate were found to produce good measurement results. Electron doses inside the target chamber were highly anisotropic and peaked at backward direction by several orders of magnitude. Photon doses outside the target chamber were nearly isotropic (a factor of ∼2 higher in backward direction). When considering the large uncertainties of the irradiance (a factor of 2-3) and the potential shielding effects from detectors and target chamber, the measured photon dose rates at 1 m (150 mJ and 10 Hz) outside the target chamber (when averaged over different types of detectors) were in good agreement (a factor of ∼3) with the calculated values of the SLAC model, except at 3.0x10{sup 16} W/cm{sup 2}, which has an electron temperature of only 14 keV. At 6x10{sup 17} W/cm{sup 2}, a low level of ∼0.1 mrem/h from fast neutrons was measured (at 1 m, 150 mJ and 10 Hz) with a neutron-to-photon dose ratio of 0.2%. This is equivalent to a neutron dose yield of 2.8x10{sup -8} mSv/J (to be compared to the LULI measurements of 1x10{sup -4} mSv/J at 3x10{sup 19} W/cm{sup 2}). Both active and passive types of detectors performed well and the dose results were consistent, which is the same as the dose measurements in the Titan laser facility. Active detectors were not affected by the electromagnetic pulses associated with the MEC laser system; this was different from the Titan radiation measurements, in which all active detectors failed to respond, likely due to the high EMP in the Titan's high laser intensity fields. (authors)

43 PARTICLE ACCELERATORS↗

Validation of a Monte Carlo model for the MLC-Elekta Precise with MCNP6 - Paper 76

Cancer treatment using radiotherapy techniques needs an accurate prediction of the dose delivered to the patient at each position. Treatment planning systems (TPS) allow the optimization of the dose delivered to the tumor volume while minimizing the dose absorbed by the surrounding healthy tissue. Commercial treatment planning systems use empirical deterministic algorithms that do not correctly estimate the dose in the surroundings of heterogeneities. This lack of accuracy is taken into account as bigger security margins in the treatment, reducing the potential effect of the treatment. However, Monte Carlo (MC) simulation techniques have proved to predict the dose distribution more accurately and also representing experimental data better. Nevertheless, the clinical application of these techniques has been limited by the long calculation times they require. As high performance computers decrease in cost MC simulations become more feasible to be used in TPS. The present work improves a simplified model of the MLC-Elekta Precise linear accelerator (linac or unit from now on) previously developed and correctly validated by the group. A multileaf collimator (MLC) has been modelled according to the manufacturer specifications and added to the previous model to allow higher conformity in the studies. The full geometry has been entered to the MCNP6 Monte Carlo code to simulate the transport of particles through the linac. The geometry also includes a cubic water phantom for dosimetry studies and validation with experimental data. The experimental data employed for the dose distribution comparison has been measured at the linac from the linac Hospital Universitari Clinic de Valencia (Spain). Additionally, particles are stored in a phase space surface before their entrance in the water to be analyzed and for performance optimization. Given the results presented, we conclude that this first approach to validate a model of the Elekta Precise linac from the Hospital Cl nic Universitari de Valancia represents well the depth-dose distribution, but fails at representing the dose profiles. It has been shown that they predict too much penumbra, probably caused by the filtration between the leaves. In order to solve this problems, further work is needed to improve the simulated model. This work will mainly focus on the multileaf collimator. Also, the codes developed by the group to analyze phase space files produced by MCNP6 have proven highly useful. As work progress and the codes are debugged, they will be published so that the community can take advantage of them.

61 RADIATION PROTECTION AND DOSIMETRY↗

SNS Sample Activation Calculator Experimental Validation - Paper 79

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of all samples after they have been exposed to the neutron beam in any of the neutron scattering instruments at the SNS beamlines. The SAC web page takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and then calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and beamline scientists and users have noticed discrepancies in the predicted activation of their samples. As a part of the Neutronics Analysis Group at SNS, we were tasked with validating the SAC tool and diagnosing the origin of the discrepancies seen by the beamline scientists and the users. In the process of performing these measurements, we additionally found that several aspects of realistic neutron scattering operations, and thus sample exposure, cannot be captured with current configuration of the SAC tool. Typical neutron scattering samples are irradiated for multiple periods with different neutron energy ranges; the realities of accelerator operation indicate that not all of those periods will be at the same accelerator power, and scattering samples are frequently not fully illuminated by the well-collimated neutron beam. Finally, we will explore whether neutron beams, as modified by neutron guide systems with energy-dependent intensity modifications and by precise energy-band defining mechanical choppers, are suitably analyzed with multigroup cross section libraries in which there are typically very few energy groups below one eV. (authors)

43 PARTICLE ACCELERATORS↗

Deterministic Simulation of First-Order Scattering in a Clinical X-ray Computed Tomography Scanner - Paper 81

In nondestructive testing (NDT) and medical diagnostic x-ray imaging (photon energy<140 keV), scattered x-ray caused by Compton and Rayleigh scattering should be eliminated. Scattered x-ray photons reduce image contrast, increase image noise, and introduce artifact into the reconstructed computed tomography (CT) images. In cone-beam CT, where the coverage of the x-ray beam and the area of the detector are significantly larger than those in fan-beam CT, x-ray photon scatter is one of the major sources of image degradation. The artifacts caused by scattered x-ray photon can be divided into two categories: 1) low spatial frequency scatter profile adds a positive bias to the detected radiation signal, thus reducing the effective attenuation of the imaged object, resulting in a negative bias in the measured linear attenuation coefficient in the image; 2) a high spatial frequency scatter profile causes a differential artifact, such as shading in uniform regions. A real x-ray scan is composed of both low and high frequency scatter profiles. Thus, the key to a successful scatter correction is the ability to accurately capture the scatter profile of a real x-ray imaging scan. The most accurate method for estimating a scatter profile is the Monte Carlo simulation. However, the computation cost of the Monte Carlo method makes it unfeasible for simulating real and complex scan geometries in clinical settings. A practical yet accurate scatter profile estimation method is through ray tracing techniques, where the scatter profiles are computed by tracking rays through the object's volume. The x-ray from the source is tracked when it interacts with the material in the volume. The interaction creates scattered x-rays, in all possible directions. These rays are again either attenuated or scattered, creating cascaded scatter events. In x-ray CT, the first-order scattering (where only one scatter interaction is encountered) accounts for the most severe image artifacts since this first-order scatter contains a high frequency component of the scatter profile. Previous studies have shown that ray tracing techniques are quite effective in simulating the contribution of first-order scattering in radiological images. In this study, a similar ray tracing technique is applied to simulate the scatter profile of a real x-ray computed tomography (CT) scan in clinical settings. A good agreement has been found between the simulated scatter profile and the experimental measurement result. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Low Power ARM Processors for Monte Carlo Particle Transport: MCNP6 on the ARM Cortex-A8 - Paper 83

In the push towards exascale computing, the limiting factors are power requirements and heat dissipation. Using current technology, the power required to drive an exascale supercomputer would near 400-MW. Clearly, future computing hardware will have to be more energy efficient in order to achieve exascale performance. Most of the current research in advanced computing architectures is in the use of standard CPUs with accelerators. However, these accelerators are not generally supported by the traditional scientific programming languages (C, C++, and Fortran) and the scientific software must be tailored specifically to take advantage of the accelerators. Large scale scientific software (hundreds-of-thousand to millions of lines of code) can not be easily ported to the computing platform du jour. The widespread use of low power ARM based processors in the mobile computing market offer a low power alternative to accelerators that are also supported by the traditional scientific programming languages and programming paradigms such as MPI and OpenMP. Computing architectures for scientific computing are often assessed using standard benchmarks such as LINPACK benchmark or using suites of mini-applications that are greatly simplified stand-ins for scientific software. Often the real applications that will deployed on the scientific supercomputers are not ported or tested until delivery of the machines. In order to evaluate the use of ARM processors for scientific computing the Monte Carlo particle transport code, MCNP version 6 was compiled on the ARM Cortex-A8 and a set of benchmark problems were used to assess performance in comparison to an Intel Xeon E5-2670 and the low power Intel Atom N270. MCNP is a continuous energy Monte Carlo particle transport code in development at Los Alamos National Laboratory since 1977. MCNP is used to transport neutrons, photon, electrons, and charged particles using continuous energy interaction data. It is commonly used in fields of nuclear power, nuclear medicine, radiation protection, and high-energy physics through-out the world. MCNP version 6 is approximately 450 thousand lines of code, written primary in Fortran90, with some C and C++. MCNP supports distributed multiprocessing using MPI and threading with OpenMP. The ARM Cortex-A8 executes MCNP6 using about twice as much power as the Intel Xeon E5-2670 and about the same amount of power as the Intel Atom N270. However, these results are encouraging for the use of low-power ARM chips in future supercomputers. The ARM Cortex-A8 is a 32-bit CPU and it's NEON general-purpose SIMD (single-instruction multiple data) engine does not support double-precision floating-point arithmetic. More recent ARM processors (ARM Cortex-A53 and Cortex-A57) support 64-bit addressing and have NEON co-processors that support double-precision floating-point arithmetic. ARM claims that the A50 series delivers a performance increase of 15 times the Cortex-A8 performance for similar power usage. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Overview of the forthcoming AAPM TG-158 Report, 'Measurements and calculations of doses outside the treatment volume from External Beam Radiation Therapy' - Paper 85

The evolution of techniques and technology in radiotherapy has greatly improved our ability to deliver higher tumor doses while minimizing the dose to the adjacent organs at risk. However, this improved conformality has not removed the problem of doses to normal tissues outside the target volume. Whether these out-of-field doses arise from photons, electrons, protons or neutrons, there are unique challenges that many medical physicists may have limited knowledge about or experience with. With modern treatment planning systems, high dose regions and areas within the primary beam path are typically well described. However, their accuracy beyond a few centimeters outside the treatment field edge are usually poor. In these cases, alternate methods are required to assess the out-of-field dose. Such assessments require additional care to avoid potentially large errors associated with a variety of unique complications in performing dosimetry outside the treatment field. Furthermore, physicists will not always have an a priori estimate of the expected dose, and, as a result, large dosimetric errors are more easily missed. Low radiation doses outside the treatment volume are a concern because they can cause deleterious effects to the patient. The risk of late effects from the secondary radiation may be more evident today because of the success of cancer screening and modern therapies that have increased the number of cancer patients who survive and live long enough for the adverse radiation effects on healthy tissues to manifest. Simultaneously, radiotherapy procedures have become more complex, making the estimation of low out-of-field doses even more challenging. Over the past 30 years, numerous studies have been published detailing non-target doses from various radiotherapy treatments (for a detailed review see Xu et al. However, dosimetry data were obtained using a variety of measurement or computational techniques. An overview of dosimetry techniques for measuring low-level non-target doses is not available. Improved, or at least valid, dosimetry is important for several reasons. In clinical care (e.g. fetal dose estimates), large dose errors can lead to inappropriate or unnecessary treatment decisions, with potentially serious consequences to the patient. In a broader sense of somatic effects, more accurate dosimetry will improve patient risk assessment, understanding of dose responses, treatment planning, and design of the radiation delivery machines. Once reliable dosimetry data are available, it is then the clinician's responsibility to assess the risk vs. benefit of the radiotherapy treatment to make a sound and informed assessment of all possible treatment outcomes. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement and Analysis of Dose Rate Distribution in the Seismic Base-Isolation pit of the Electron Linac Oncology Facility - Paper 87

Recently electric linac oncology facilities incorporating seismic base-isolation structure have become very popular in Japan to prevent strong impact to the equipment by the earthquakes. When the boundary of the controlled area is set below the base-isolated foundations, additional shielding of iron plate is needed and the cost for shielding sometimes increases up to $1 M Since no one usually accesses underneath the treatment room, except short maintenance period for base-isolation structure, it is reasonable to set the boundary around the downstairs room (pit) by fence. However, it is very difficult to estimate the dose rate of new boundary by using the simple shielding calculation method, because of rotating gantry head and effect of scattering radiation in the base-isolation floor. In this study detail calculations by using Monte-Carlo calculation code MCNP5 have been performed to find out the practical shielding design. To be more specific, investigation for the complicated behavior of photons in the 'pit' have been performed by the analysis, i.e. (1) How much can we reduce the thickness of additional iron plate?, (2) Which angle of the beam direction will influence the most to the dose rate at the new boundary?, (3) Which component of the radiation is dominant at the new boundary? We also verified the calculated results by the measurement. We have performed the analysis of the behavior of photons in the pit and found out no additional iron shielding was necessary, which carried out an extreme reduction of costs. The main contribution to the dose rate at the boundary was scattered photons in the case of 0- degree beam direction. Good agreement between calculated and measured results were obtained, and passed the examination by the authority. It is concluded that the Monte-Carlo calculation code MCNP5 is very effective for the optimistic design of the electron linac oncology facilities incorporating seismic base-isolation structure. (authors)

43 PARTICLE ACCELERATORS↗

A new solution for the 1D neutral particle transport equation in heterogeneous media - Paper 89

The equation of photon transport in directionally discretized 2N streams has been the subject of various numerical algorithms over the past 65 years since Chandrasekhar first explored the concept. The importance of this equation cannot be overemphasized, as it characterizes neutral particles (in this case photons) undergoing collisions as characterized by the scattering phase function in a 1D slab medium. More precisely, particles enter a homogeneous slab medium with the particle intensity distribution to be numerically determined. We find applications in light scattering for graphical rendering as well as deep penetration photon transport in a scattering medium as considered here. Noting the algebraic nature of the solution, numerous numerical attempts at an efficient algorithm have appeared in the literature-- many involving numerical linear algebra. Most notable are the Discrete Ordinates Method [DOM] of Stamnes and the Analytical Discrete Ordinates (ADO) method of Siewert as well as the Laplace Transform (LTSN) method of Vilhena. The methods are all centered on the determination of eigenvalues (or zeros of a polynomial in the case of the LTSN method) of a linear system enabling the solution to be represented as a sum of exponential eigenvectors. Because of the unstable nature of the solution, unless one takes care, such a representation leads to numerical catastrophe. Here, we derive an alternative form of solution to overcome this difficulty for application to deep penetration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Eikonal Corrections for Nucleus-Nucleus Reaction Cross Sections - Paper 90

The goal of this research is to modify a Fortran computer code, which uses an optical potential approximation to quantum mechanical multiple-scattering theory to compute total and reaction cross sections for nucleon-nucleus and nucleus-nucleus collisions for use in space radiation protection and shielding applications. These nuclear collision cross sections are utilized in space radiation transport codes that describe the passage of solar and galactic cosmic radiation fields through matter. In the code being modified by this work, an Eikonal approximation, in analogy with the complex index of refraction used to describe absorption in optics, is used to formulate the nuclear scattering amplitudes that describe the total and reaction cross sections in the formalism. Previous work found that the cross sections calculated with this model sometimes underestimated the experimental data. It has been noted that the Eikonal phase functions, which are used to calculate these cross sections and which contain all of the scattering information in the model, can be improved by incorporating higher order corrections In this work, a previously-developed first-order correction to the Eikonal phase function is coded in Fortran and incorporated into the optical model computer code that calculates reaction cross sections for nucleon-nucleus and nucleus-nucleus collisions at energies relevant to space radiation protection and shielding. The main thrust of this work is to test the use of this higher order correction by calculating reaction cross sections for a variety of nuclear collisions and comparing the results to experimental data. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Using Tally Values to Add a Third Dimension when Viewing Planar Mesh Tallies - Paper 95

Mesh tallies show a calculated quantity, such as radiation flux or dose rate, in cells of a rectangular, cylindrical, or spherical mesh. Mesh tallies are useful when the spatial distribution of the quantity is of interest. They are usually displayed in two dimensional (2D) plots with the tally values represented by color coding. Geometry outlines and/or contour lines may be included. Three dimensional (3D) views of rectangular tallies often show a set of tally planes within the geometry. We describe here a new 3D mesh tally plot where the third dimension of a rectangular mesh tally plane is determined by the tally value in each mesh cell. We refer to such plots as elevated mesh tally plots. These plots may aid in analysis and presentation of the results of a transport calculation. The results shown here were calculated with the Monte Carlo transport code MCNPX2.7. The plots were made with the White Rock Science visualization and geometry editing program Moritz. The elevated mesh tally plots have been implemented within Moritz. The elevation method is, at present, only applicable to rectangular mesh tallies. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Novel Gamma Spectroscopy Method Based on Coincident Measurement of Two Detectors - Paper 98

Spectrum measurement for megavoltage Bremsstrahlung x-rays has been a long-standing challenge. This is because high-energy photons mostly undergo Compton scattering interactions in a detector, and consequently rarely fully deposit their energies in the detector. Most published results of the megavoltage Bremsstrahlung photon spectra were obtained based on reconstruction (or unfolding) from the measured data. These results are unsatisfactory because the process of spectrum unfolding involves the use of the detector's response function which itself often contain large errors. In this experimental study, we developed and tested a new gamma spectrum measurement method that is based on coincident measurement of two detectors. The goal was to eliminate the spectrum unfolding process and thus to be able to obtain the photon spectrum more accurately. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4 and beyond: recent progress in precision physics modeling - Paper 100

This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

CINDER08 and Scripting Environment for Accelerator Activation Problems - Paper 101

CINDER is a transmutation code, developed originally at the Bettis Atomic Power Laboratory, which predicts induced radioactivity due to either reactor or accelerator-driven radiation sources. The code and associated data libraries have been expanded and improved over the years at Los Alamos National Laboratory. CINDER08 is the latest update in the series and represents a complete rewrite of CINDER, improving it in many areas. Beginning with CINDER90, several Perl scripts were developed to treat multi-cell problems in combination with the radiation transport code MCNPX. These scripts simplified the preparation of CINDER input and made the code much more user-friendly. In concert with the development of CINDER08, these scripting tools have also been updated. The script developers are intensive users of CINDER and had significant input into the development of CINDER08. CINDER08, through use of these scripts, also works with output from MCNP5, which is useful for problems that do not require the extended particle capabilities of MCNPX and do not require particle energies outside of the tabular physics regime, and with MCNP6. A new version of CINDER, CINDER08, incorporates many improvements to the coding and the data libraries. Updated versions of scripting tools improve the code's usability and simplify the use of CINDER output as the basis of gamma source terms for subsequent calculations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗