Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Adoption of a SAML-XACML profile for authorization interoperability across grid middleware in OSG and EGEE

The Authorization Interoperability activity was initiated in 2006 to foster interoperability between middleware and authorization infrastructures deployed in the Open Science Grid (OSG) and the Enabling Grids for E-sciencE (EGEE) projects. This activity delivered a common authorization protocol and a set of libraries that implement that protocol. In addition, a set of the most common Grid gateways, or Policy Enforcement Points (Globus Toolkit v4 Gatekeeper, GridFTP, dCache, etc.) and site authorization services, or Policy Decision Points (LCAS/LCMAPS, SCAS, GUMS, etc.) have been integrated with these libraries. At this time, various software providers, including the Globus Toolkit v5, BeStMan, and the Site AuthoriZation service (SAZ), are integrating the authorization interoperability protocol with their products. In addition, as more and more software supports the same protocol, the community is converging on LCMAPS as a common module for identity attribute parsing and authorization call-out. This paper presents this effort, discusses the status of adoption of the common protocol and projects the community work on authorization in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise-canceling quantum feedback: Non-Hermitian dynamics with applications to state preparation and magic state distillation

Time-continuous quantum measurement allows for the tracking of a quantum system in real time via sequences of short, and individually weak, measurement intervals. Such measurements are necessarily invasive, imparting backaction to the system, and allowing the observer to update their state estimate based on stochastic measurement outcomes. Feedback control then involves real-time interventions by an observer, conditioned on the time-continuous measurement signal that they receive. Here, we consider here diffusive quantum trajectories and focus on the “noise-canceling” subset of feedback protocols that aim to minimize the degree of stochasticity in the dynamics. We derive such a class of feedback operations, showing that under the idealized assumptions of pure states, unit measurement efficiency, and zero time delay in implementing feedback operations, perfectly noise-canceling feedback always exists. We consider the resulting noise-canceled dynamics generated by an effective non-Hermitian Hamiltonian; while non-Hermitian Hamiltonians from continuous monitoring generally describe rare dynamics (accessible by costly postselection), the use of noise-canceling feedback here leads to non-Hermitian dynamics that occur deterministically. We demonstrate this via examples of entangled state preparation and stabilization. We then illustrate the potential for the application of noise cancellation to boost success rates in magic state distillation protocols. We show that adding feedback based on noise cancellation into a time-continuous five-to-one distillation protocol leads to higher probabilities of successful distillation across a range of input errors and increases the threshold on input errors for which the protocol is effective. Our results highlight the efficacy of noise-canceling feedback-aided protocols for quantum state preparation and stabilization tasks.

Karmakar, Tathagata [University of California, Ber↗

Quantum secret sharing using weak coherent states

Secret sharing allows a trusted party (the dealer) to distribute a secret to a group of players, who can only access the secret cooperatively. Quantum secret sharing (QSS) protocols could provide unconditional security based on fundamental laws in physics. While the general security proof has been established recently in an entanglement-based QSS protocol, the tolerable channel loss is unfortunately rather small. Here we propose a continuous variable QSS protocol using conventional laser sources and homodyne detectors. In this protocol, a Gaussian-modulated coherent state (GMCS) prepared by one player passes through the secure stations of the other players sequentially, and each of the other players injects a locally prepared, independent GMCS into the circulating optical mode. Finally, the dealer measures both the amplitude and the phase quadratures of the receiving optical mode using double homodyne detectors. Collectively, the players can use their encoded random numbers to estimate the measurement results of the dealer and further generate a shared key. We prove the unconditional security of the proposed protocol against both eavesdroppers and dishonest players in the presence of high channel loss, and discuss various practical issues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum advantages for Pauli channel estimation

We show that entangled measurements provide an exponential advantage in sample complexity for Pauli channel estimation, which is both a fundamental problem and a practically important subroutine for benchmarking near-term quantum devices. The specific task we consider is to simultaneously learn all the eigenvalues of an n-qubit Pauli channel to ±ε precision. We give an estimation protocol with an n-qubit ancilla that succeeds with high probability using only O(n/ε 2 ) copies of the Pauli channel, while proving that any ancilla-free protocol (possibly with adaptive control and channel concatenation) would need at least Ω(2 n/3 ) rounds of measurement. We further study the advantages provided by a small number of ancillas. For the case that a k-qubit ancilla (k≤n) is available, we obtain a sample complexity lower bound of Ω(2 (n-k)/3 ) for any nonconcatenating protocol, and a stronger lower bound of Ω(n 2n-k ) for any nonadaptive, nonconcatenating protocol, which is shown to be tight. We also show how to apply the ancilla-assisted estimation protocol to a practical quantum benchmarking task in a noise-resilient and sample-efficient manner, given reasonable noise assumptions. Our results provide a practically interesting example for quantum advantages in learning and also bring insights for quantum benchmarking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward improved quantum simulations and sensing with trapped two-dimensional ion crystals via parametric amplification

Improving coherence is a fundamental challenge in quantum simulation and sensing experiments with trapped ions. Here we discuss, experimentally demonstrate, and estimate the potential impacts of two different protocols that enhance, through motional parametric excitation, the coherent spin-motion coupling of ions obtained with a spin-dependent force. The experiments are performed on two-dimensional crystal arrays of approximately 100 9 ⁢Be + ions confined in a Penning trap. By modulating the trapping potential at close to twice the center-of-mass mode frequency, we squeeze the motional mode and enhance the spin-motion coupling while maintaining spin coherence. With a stroboscopic protocol, we measure 5.4 ± 0.9 dB of motional squeezing below the ground-state motion, from which theory predicts a 10-dB enhancement in the sensitivity for measuring small displacements using a recently demonstrated protocol [K. A. Gilmore et al., Science 373, 673 (2021)]. With a continuous squeezing protocol, we measure and accurately calibrate the parametric coupling strength. Theory suggests this protocol can be used to improve quantum spin squeezing, limited in our system by off-resonant light scatter. Finally, we illustrate numerically the trade-offs between strong parametric amplification and motional dephasing in the form of center-of-mass frequency fluctuations for improving quantum spin squeezing in our setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fair loss-tolerant quantum coin flipping

Coin flipping is a cryptographic primitive in which two spatially separated players, who do not trust each other, wish to establish a common random bit. If we limit ourselves to classical communication, this task requires either assumptions on the computational power of the players or it requires them to send messages to each other with sufficient simultaneity to force their complete independence. Without such assumptions, all classical protocols are so that one dishonest player has complete control over the outcome. If we use quantum communication, on the other hand, protocols have been introduced that limit the maximal bias that dishonest players can produce. However, those protocols would be very difficult to implement in practice because they are susceptible to realistic losses on the quantum channel between the players or in their quantum memory and measurement apparatus. In this paper, we introduce a quantum protocol and we prove that it is completely impervious to loss. The protocol is fair in the sense that either player has the same probability of success in cheating attempts at biasing the outcome of the coin flip. We also give explicit and optimal cheating strategies for both players.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast quantum phase gate in a small-detuning circuit QED model

We propose a theoretical protocol for a quantum phase gate between two transmon qubits capacitively coupled to a superconducting transmission line resonator driven by a strong microwave field. Compared with previous protocols involving a dispersive regime, our protocol works at a small detuning, {Delta}{approx}g, and the nontrivial two-qubit gates can be realized in a short time, {approx}1/g, where g is the qubit-resonator coupling strength. Our analysis shows that the protocol is robust against the main decoherence sources and unavoidable parameter variations. Moreover, our protocol can be implemented using the current experimental design of circuit QED.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One-step deterministic polarization-entanglement purification using spatial entanglement

We present a one-step deterministic entanglement purification protocol with linear optics and postselection. Compared with the Simon-Pan protocol [C. Simon and J. W. Pan, Phys. Rev. Lett. 89, 257901 (2002)], this one-step protocol has some advantages. First, it can obtain a maximally entangled pair from each photon pair with only one step, instead of improving the fidelity of less-entangled photon pairs by performing the entanglement purification process repeatedly in other protocols. Second, it works in a deterministic way, not a probabilistic one, which greatly reduces the number of entanglement resources needed. Third, it does not require the polarization state be entangled; only spatial entanglement is needed. Moreover, it is feasible with current techniques [J. W. Pan, S. Gasparonl, R. Ursin, G. Weihs, and A. Zellinger, Nature (London) 423, 417 (2003)]. All these advantages make this one-step protocol more convenient than others in quantum-communication applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semi-device-independent random-number expansion without entanglement

By testing the classical correlation violation between two systems, true random numbers can be generated and certified without applying classical statistical method. In this work, we propose a true random-number expansion protocol without entanglement, where the randomness can be guaranteed only by the two-dimensional quantum witness violation. Furthermore, we only assume that the dimensionality of the system used in the protocol has a tight bound, and the whole protocol can be regarded as a semi-device-independent black-box scenario. Compared with the device-independent random-number expansion protocol based on entanglement, our protocol is much easier to implement and test.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Loss-tolerant quantum secure positioning with weak laser sources

Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. It has recently been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here in this paper, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit. Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. Lastly, in this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.

47 OTHER INSTRUMENTATION↗

Remote Entanglement via Adiabatic Passage Using a Tunably Dissipative Quantum Communication System

Effective quantum communication between remote quantum nodes requires high fidelity quantum state transfer and remote entanglement generation. Recent experiments have demonstrated that microwave photons, as well as phonons, can be used to couple superconducting qubits, with a fidelity limited primarily by loss in the communication channel. Adiabatic protocols can overcome channel loss by transferring quantum states without populating the lossy communication channel. In this work, we present a unique superconducting quantum communication system, comprising two superconducting qubits connected by a 0.73 m-long communication channel. Significantly, we can introduce large tunable loss to the channel, allowing exploration of different entanglement protocols in the presence of dissipation. When set for minimum loss in the channel, we demonstrate an adiabatic quantum state transfer protocol that achieves 99% transfer efficiency as well as the deterministic generation of entangled Bell states with a fidelity of 96%, all without populating the intervening communication channel, and competitive with a qubit-resonant mode-qubit relay method. We also explore the performance of the adiabatic protocol in the presence of significant channel loss, and show that the adiabatic protocol protects against loss in the channel, achieving higher state transfer and entanglement fidelities than the relay method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Criticality Under Imperfect Teleportation

Entanglement, measurement, and classical communication together enable teleportation of quantum states between distant parties, in principle, with perfect fidelity. To what extent do correlations and entanglement of a many-body wave function transfer under teleportation protocols? We address this question for the case of an imperfectly teleported quantum critical wave function, focusing on the ground state of a critical Ising chain. We demonstrate that imperfections, e.g., in the entangling gate adopted for a given protocol, effectively manifest as weak measurements acting on the otherwise pristinely teleported critical state. Armed with this perspective, we leverage and further develop the theory of measurement-altered quantum criticality to quantify the resilience of critical-state teleportation. We identify classes of teleportation protocols for which imperfection (i) preserves both the universal long-range entanglement and correlations of the original quantum critical state, (ii) weakly modifies these quantities away from their universal values, and (iii) obliterates long-range entanglement altogether while preserving power-law correlations, albeit with a new set of exponents. We also show that mixed states describing the average over a series of sequential imperfect teleportation events retain pristine power-law correlations due to a “built-in” decoding algorithm, though their entanglement structure measured by the negativity depends on errors similarly to individual protocol runs. These results may allow one to design teleportation protocols that optimize against errors—highlighting a potential practical application of measurement-altered criticality. Published by the American Physical Society 2024

Physics↗

Open-Source Framework for Data Storage and Visualization of Real-Time Experiments

Digital real time simulators (DRTS) are increasingly being used for the evaluation of power hardware and controller hardware in the laboratory prior to field deployment. Although DRTS are capable of simulating large models in real-time, it is challenging to visualize the results of large models without overdrawing or confounding the viewer. This paper provides an open-source framework for users to visualize their DRTS-based hardware-in-the-loop (HIL) experimental results in real-time. This proposed framework can be used by experimental test beds that can push data through an internet protocol based network. The proposed framework includes three main components. First, it includes the DRTS that generates and pushes the data to a relay. Second, it includes an application that serves multiple purposes, from data storage, testing, and translation of the data to a publisher/subscriber protocol. Finally, it includes libraries and applications that can be used to visualize the data by subscribing to the relay. This framework is available in open source, and it is tested using the HIL platform developed for testing advanced distribution management systems.

advanced distribution management systems↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗

Air kerma based dosimetry calibration for the Leksell Gamma Knife

No accepted official protocol exists for the dosimetry of the Leksell Gamma Knife registered (GK) stereotactic radiosurgery device. Establishment of a dosimetry protocol has been complicated by the unique partial-hemisphere arrangement of 201 individual {sup 60}Co beams simultaneously focused on the treatment volume and by the rigid geometry of the GK unit itself. This article proposes an air kerma based dosimetry protocol using either an in-air or in-acrylic phantom measurement to determine the absorbed dose rate of fields of the 18 mm helmet of a GK unit. A small-volume air ionization chamber was used to make measurements at the physical isocenter of three GK units. The absorbed dose rate to water was determined using a modified version of the AAPM Task Group 21 protocol designed for use with {sup 60}Co-based teletherapy machines. This experimentally determined absorbed dose rate was compared to the treatment planning system (TPS) absorbed dose rate. The TPS used with the GK unit is Leksell GammaPlan. The TPS absorbed dose rate at the time of treatment is the absorbed dose rate determined by the physicist at the time of machine commissioning decay corrected to the treatment date. The TPS absorbed dose rate is defined as absorbed dose rate to water at the isocenter of a water phantom with a radius of 8 cm. Measurements were performed on model B and C Gamma Knife units. The absorbed dose rate to water for the 18 mm helmet determined using air-kerma based calculations is consistently between 1.5% and 2.9% higher than the absorbed dose rate provided by the TPS. These air kerma based measurements allow GK dosimetry to be performed with an established dosimetry protocol and without complications arising from the use of and possible variations in solid phantom material. Measurements were also made with the same ionization chamber in a spherical acrylic phantom for comparison. This methodology will allow further development of calibration methods appropriate for the smaller fields of GK units to be compared to a well established standard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A prototype fan-beam optical CT scanner for 3D dosimetry

Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry. Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, {lambda} = 543 nm) with line-generating lens, and a laser diode module (LDM, {lambda} = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator. Optimal collimator depth was determined by observing the signal of a single photodiode with varying collimator depths. A method of extending the dynamic range of the system is presented. Two sample types were used for evaluations: nondosimetric absorbent solutions and irradiated polymer gel dosimeters, each housed in 1 liter cylindrical plastic flasks. Imaging protocol investigations were performed to address ring artefacts and image noise. Two image artefact removal techniques were performed in sinogram space. Collimator efficacy was evaluated by imaging highly opaque samples of scatter-based and absorption-based solutions. A noise-based flask registration technique was developed. Two protocols for gel manufacture were examined. Results: The LDM proved advantageous over the HeNe laser due to its reduced noise. Also, the LDM uses a wavelength more suitable for the PRESAGE{sup TM} dosimeter. Collimator depth of 1.5 cm was found to be an optimal balance between scatter rejection, signal strength, and manufacture ease. The multihole collimator is capable of maintaining accurate scatter-rejection to high levels of opacity with scatter-based solutions (T < 0.015%). Imaging protocol investigations support the need for preirradiation and postirradiation scanning to reduce reflection-based ring artefacts and to accommodate flask imperfections and gel inhomogeneities. Artefact removal techniques in sinogram space eliminate streaking artefacts and reduce ring artefacts of up to {approx}40% in magnitude. The flask registration technique was shown to achieve submillimetre and subdegree placement accuracy. Dosimetry protocol investigations emphasize the need to allow gel dosimeters to cool gradually and to be scanned while at room temperature. Preliminary tests show that considerable noise reduction can be achieved with sinogram filtering and by binning image pixels into more clinically relevant grid sizes. Conclusions: This paper describes a new optical CT scanner for 3D radiation dosimetry. Tests demonstrate that it is capable of imaging both absorption-based and scatter-based samples of high opacities. Imaging protocol and gel dosimeter manufacture techniques have been adapted to produce optimal reconstruction results. These optimal results will require suitable filtering and binning techniques for noise reduction purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilizing a simple CT dosimetry phantom for the comprehension of the operational characteristics of CT AEC systems

Purpose: To investigate the utility of the nested polymethylacrylate (PMMA) phantom (which is available in many CT facilities for CTDI measurements), as a tool for the presentation and comparison of the ways that two different CT automatic exposure control (AEC) systems respond to a phantom when various scan parameters and AEC protocols are modified.Methods: By offsetting the two phantom's components (the head phantom and the body ring) half-way along their longitudinal axis, a phantom with three sections of different x-ray attenuation was created. Scan projection radiographs (SPRs) and helical scans of the three-section phantom were performed on a Toshiba Aquilion 64 and a Philips Brilliance 64 CT scanners, with different scan parameter selections [scan direction, pitch factor, slice thickness, and reconstruction interval (ST/RI), AEC protocol, and tube potential used for the SPRs]. The dose length product (DLP) values of each scan were recorded and the tube current (mA) values of the reconstructed CT images were plotted against the respective Z-axis positions on the phantom. Furthermore, measurements of the noise levels at the center of each phantom section were performed to assess the impact of mA modulation on image quality.Results: The mA modulation patterns of the two CT scanners were very dissimilar. The mA variations were more pronounced for Aquilion 64, where changes in any of the aforementioned scan parameters affected both the mA modulations curves and DLP values. However, the noise levels were affected only by changes in pitch, ST/RI, and AEC protocol selections. For Brilliance 64, changes in pitch affected the mA modulation curves but not the DLP values, whereas only AEC protocol and SPR tube potential selection variations affected both the mA modulation curves and DLP values. The noise levels increased for smaller ST/RI, larger weight category AEC protocol, and larger SPR tube potential selection.Conclusions: The nested PMMA dosimetry phantom can be effectively utilized for the comprehension of CT AEC systems performance and the way that different scan conditions affect the mA modulation patterns, DLP values, and image noise. However, in depth analysis of the reasons why these two systems exhibited such different behaviors in response to the same phantom requires further investigation which is beyond the scope of this study.

61 RADIATION PROTECTION AND DOSIMETRY↗