Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real Time Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Intelligent Monitoring Systems and Advanced Well Integrity and Mitigation

Long-term seismic monitoring of carbon capture and storage projects is needed to verify that the injected gas is safely stored in the subsurface until permanence can be assured. Conventional surface seismic monitoring techniques are usually expensive, require highly invasive surface operations, and need significant time investments on the part of personnel for both the field effort and processing the acquired data. For these reasons, permanent reservoir monitoring technologies are preferred, as they can offer a cost-effective solution for long-term monitoring. As part of the monitoring program of the Archer Daniels Midland’s large-scale injection of CO 2 in Decatur, Illinois, USA, a continuous seismic monitoring array was installed using a combination of surface orbital vibrator (SOV) sources and fiber-optic cables for distributed acoustic sensing (DAS) acquisition with the objective to build a continuous monitoring array. The aim of the presented project was to build a monitoring array and platform that integrates real-time seismic data with conventional data streams and provides continuous data analysis using dynamic computational models to deliver a comprehensive real-time assessment of subsurface conditions. It is in this context that the Intelligent Monitoring Systems and Advanced Well Integrity and Mitigation project was proposed with the objective to develop an integrated architecture that utilizes a permanent seismic monitoring network, combines the real-time geophysical and process data with reservoir flow and geomechanical models to create a comprehensive monitoring, visualization, and control system that delivers critical information for process surveillance and optimization.

54 ENVIRONMENTAL SCIENCES↗

Variable-rate optical communication through the turbulent atmosphere

It was demonstrated that the data transmitter can extract real time, channel state information by processing the field received when a pilot tone is sent from the data receiver to the data transmitter. Based on these channel measurements, optimal variable rate techniques were derived and significant improvements in system perforamnce were obtained, particularly at low bit error rates.

Levitt, B. K.↗

Optimized variational analysis scheme of single Doppler radar wind data

A computer scheme for extracting singularities has been developed and applied to single Doppler radar wind data. The scheme is planned for use in real-time wind and singularity analysis and forecasting. The method, known as Doppler Operational Variational Extraction of Singularities is outlined, focusing on the principle of local symmetry. Results are presented from the application of the scheme to a storm-generated gust front in Oklahoma on May 28, 1987.

Sasaki, Yoshi K.↗

(abstract) A Comparison Between Measurements of the F-layer Critical Frequency and Values Derived from the PRISM Adjustment Algorithm Applied to Total Electron Content Data in the Equatorial Region

The Parametrized Real-Time Ionosphere Specification Model (PRISM) is a global ionospheric specification model that can incorporate real-time data to compute accurate electron density profiles. Time series of computed and measured data are compared in this paper. This comparison can be used to suggest methods of optimizing the PRISM adjustment algorithm for TEC data obtained at low altitudes.

total electron content TEC PRISM electron content ↗

NASA Tech Briefs, March 2013

Topics covered include: Remote Data Access with IDL Data Compression Algorithm Architecture for Large Depth-of-Field Particle Image Velocimeters Vectorized Rebinning Algorithm for Fast Data Down-Sampling Display Provides Pilots with Real-Time Sonic-Boom Information Onboard Algorithms for Data Prioritization and Summarization of Aerial Imagery Monitoring and Acquisition Real-time System (MARS) Analog Signal Correlating Using an Analog-Based Signal Conditioning Front End Micro-Textured Black Silicon Wick for Silicon Heat Pipe Array Robust Multivariable Optimization and Performance Simulation for ASIC Design; Castable Amorphous Metal Mirrors and Mirror Assemblies; Sandwich Core Heat-Pipe Radiator for Power and Propulsion Systems; Apparatus for Pumping a Fluid; Cobra Fiber-Optic Positioner Upgrade; Improved Wide Operating Temperature Range of Li-Ion Cells; Non-Toxic, Non-Flammable, -80 C Phase Change Materials; Soft-Bake Purification of SWCNTs Produced by Pulsed Laser Vaporization; Improved Cell Culture Method for Growing Contracting Skeletal Muscle Models; Hand-Based Biometric Analysis; The Next Generation of Cold Immersion Dry Suit Design Evolution for Hypothermia Prevention; Integrated Lunar Information Architecture for Decision Support Version 3.0 (ILIADS 3.0); Relay Forward-Link File Management Services (MaROS Phase 2); Two Mechanisms to Avoid Control Conflicts Resulting from Uncoordinated Intent; XTCE GOVSAT Tool Suite 1.0; Determining Temperature Differential to Prevent Hardware Cross-Contamination in a Vacuum Chamber; SequenceL: Automated Parallel Algorithms Derived from CSP-NT Computational Laws; Remote Data Exploration with the Interactive Data Language (IDL); Mixture-Tuned, Clutter Matched Filter for Remote Detection of Subpixel Spectral Signals; Partitioned-Interval Quantum Optical Communications Receiver; and Practical UAV Optical Sensor Bench with Minimal Adjustability.

Source record↗

Simulation and Flight Test Environments for the TASAR Traffic Aware Planner

The Traffic Aware Planner (TAP) software is a flight deck decision support tool that enhances the flight crew’s ability to make flight-optimizing route change requests while airborne. The software provides conflict-free, optimized trajectory suggestions during en route flight to produce time- and fuel-savings compared to the current trajectory. The TAP software requires evaluation in an operational environment with real pilot users to validate projected benefits. To this end, a set of developmental test environments have been developed to mature the software and mitigate technical risk prior to entering operational evaluation. The unique attributes of each test environment were leveraged to provide a range of purpose- and case-dependent TAP software tests. This paper describes the elements of a testing environment, discusses several environments of varying fidelity used to test the TAP software, and provides a review of two case studies highlighting the vital role testing played in the TAP software development process.

Barney, Terique L.↗

Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous quantification of uranium( VI ), samarium, nitric acid, and temperature with combined ensemble learning, laser fluorescence, and Raman scattering for real-time monitoring

In this work, laser-induced fluorescence spectroscopy (LIFS), Raman spectroscopy, and a stacked regression ensemble was developed for near real-time quantification of uranium(VI) (1–100 μg mL –1 ), samarium (0–200 μg mL –1 ) and nitric acid (0.1–4 M) with varying temperature (20 °C–45 °C). LIFS applications range from fundamental lab-scale studies to real-time process monitoring at industrial levels, such as nuclear reprocessing applications, provided the phenomena affecting the fluorescence spectrum are accounted for (e.g., absorption, quenching, complexation). Multiple chemometric models were examined and compared to a more traditional multivariate regression approach called partial least squares (PLS). Results obtained on synthetic samples selected using D-optimal experimental design indicated that a stacked regression method, which included ridge regression, random forest, PLS, and an eXtreme gradient boost algorithm, successfully measured uranium(VI) concentrations directly in nitric acid without measuring luminescence lifetimes or standard addition. The top model resulted in percent root-mean-square error of prediction values of 5.2, 1.9, 3.0, and 2.3% for U(VI), Sm 3+ , HNO 3 , and temperature, respectively. The approach may be useful for quantifying fluorescent fission products (e.g., Sm 3+ ) to provide information on burnup of irradiated nuclear fuel. This novel framework reinforces the applicability of LIFS for real-time applications in nuclear fuel cycle applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Estimating PV power from aggregate power measurements within the distribution grid

The increased integration of photovoltaic (PV) systems in distribution grids reduces visibility and situational awareness for utilities because the PV systems' power production is usually not monitored by them. To address this problem, a method called Contextually Supervised Source Separation (CSSS) has been recently adapted for real-time estimation of aggregate PV active power generation from aggregate net active and reactive power measurements at a point in a radially configured distribution grid (e.g., substation). In its original version, PV disaggregation is formulated as an optimization problem that fits linear regression models for the aggregate PV active power generation and true substation active power load. This paper extends the previous work by adding regularization terms in the objective function to capture additional contextual information such as smoothness, by adding new constraints, by introducing new regressors such as ambient temperature, and by investigating the use of time-varying regressors. Furthermore, we perform extensive parametric analysis to study tuning of the objective function weighting factors in a way that maximizes performance and robustness. The proposed PV disaggregation method can be applied to networks with either a single PV system (e.g., megawatt scale) or many distributed ones (e.g., residential scale) connected downstream of the substation. Simulation studies with real field recorded data show that the enhancements of the proposed method reduce disaggregation error by 58% in winter and 35% in summer compared to previous CSSS-based work. When compared against a commonly used transposition model based approach, the reduction in disaggregation error is more pronounced (78% reduction in winter and 45% in summer). Additional simulations indicate that the proposed algorithm is also applicable for PV systems with time-varying power factors. In conclusion, overall, our results show that—with appropriate modeling and tuning—it is possible to accurately estimate the aggregated PV active power generation of a distribution feeder with minimal or no additional sensor deployment.

14 SOLAR ENERGY↗

Instrumentation for Hanford Direct-Feed Low-Activity Waste Real-Time, In-Line Process Monitoring - 18339

The direct-feed low-activity waste (DFLAW) process will utilize facilities in the Hanford tank farms to stage tank waste feed, a new facility to pretreat the tank waste feed, and facilities in the Hanford Waste Treatment and Immobilization Plant (WTP) to immobilize the low-activity waste (LAW) and disposition effluents from the vitrification process. Process sampling is used extensively throughout the DFLAW process to qualify waste feeds, control the process, and demonstrate compliance with regulatory and contractual commitments. The U.S. Department of Energy's Office of River Protection (ORP) has started a program to evaluate the potential benefits of replacing some sample collection requirements with realtime, in-line monitoring (RTIM). The program will identify, develop, and evaluate technologies that can reduce the number of samples required for WTP operation. Potential benefits of RTIM include elimination of process holds for sample analysis, a reduction in worker exposure to radiation and chemical hazards, decreased secondary waste volume, reducing the cost for sample collection and analysis, an improvement in product quality, and timely indication of process anomalies. In order to incorporate RTIM, the process control strategy for the overall process, as well as each unit operation, was reviewed and revisions to the strategies proposed. The following items were identified for incorporation of RTIM: - Real-time material balance calculations linked to the process control system; - Use of RTIM instruments to validate the material balance for selected analytes; - Anion analysis for determination of selected semi-volatile species (e.g., chlorine, sulfur, and fluorine) in the recycle stream. Based on the proposed process control strategy, a preliminary list of potential analytical equipment was developed. This was followed by a preliminary survey of instrument technologies currently on the market building on surveys performed for ORP, literature reviews, vendor web sites, and subject matter experts from the Savannah River National Laboratory and other U.S. Department of Energy national laboratories. Each technology was evaluated for measurement capability, operations and maintenance requirements, space requirements, and potential for application as process control instrumentation. The instrument technologies were chosen based on the following criteria: - Ability to perform analyses needed; - Potential to be used or adapted for use as process control instruments; - Potential to be adapted to size and operational constraints of standard WTP sample cabinets; - Operational and maintenance requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In Situ Observation of Directed Nanoparticle Aggregation During the Synthesis of Ordered Nanoporous Metal in Soft Templates

The prevalent approach to developing new nanomaterials is a trial and error process of iteratively altering synthesis procedures and then characterizing the resulting nanostructures. This is fundamentally limited in that the growth processes that occur during synthesis can only be inferred from the final synthetic structure. Directly observing real-time nanomaterial growth provides unprecedented insight into the relationship between synthesis conditions and product evolution, and facilitates a mechanistic approach to nanomaterial development. Here we use in situ liquid stage scanning transmission electron microscopy to observe the growth of mesoporous palladium in a solvated block copolymer (BCP) template under various synthesis conditions, and ultimately determine a refined synthesis procedure that yields ordered pores. We find that at low organic solvent (tetrahydrofuran, THF) content, the BCP assembles into a rigid, cylindrical micelle array with a high degree of short-range order, but poor long-range order. Upon slowing the THF evaporation rate using a solvent-vapor anneal step, the long-range order is greatly improved. The electron beam induces nucleation of small particles in the aqueous phase around the micelles. The small particles then flocculate and grow into denser structures that surround the micelles, forming an ordered mesoporous structure. The microscope observations revealed that template disorder can be addressed prior to reaction, and is not invariably induced by the growth process itself, allowing us to more quickly optimize the synthetic method. This work was conducted in the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. The Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy under contract DE-AC05-76RL01830. This research was funded in part by: the Presidential Early Career Award for Scientist and Engineers for I.A., the University of California Academic Senate and the University of California Laboratory fee research grant, the Laboratory-Directed Research and Development program at Sandia National Laboratories, and the Chemical Imaging Initiative at Pacific Northwest National Laboratory. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

cylindrical micelle↗

Multirate digital control system design

Methods for multirate digital control system design are discussed. A simple method for sampling rate selection based on control bandwidths is proposed. Methods for generating a discrete-time state model of a sampled-data plant and a discrete-time equivalent to an analog cost function for a sampled-data plant are described. The succesive loop closures and linear quadratic Gaussian synthesis methods are reviewed, and a constrained optimization synthesis method is introduced. The proposed sampling rate selection, discretization, and synthesis methods are applied to two example design problems. Multirate and single-rate compensators synthesized by the different methods are compared, based on closed-loop responses, with compensators having the same real-time computation load.

Berg, Martin C.↗

Tore Supra LH transmitter upgrade, a new RF driver for the power spectrum

New real time tools have been developed for testing new 700kW/3.7GHz/CW klystrons and for the operations on very long plasma shots. After the commissioning of the 18 series tubes on the high power test bed facility, the installation of the first 8 klystrons in the Tore Supra transmitter and the adjustment tests on load, this upgrade work has been materialized during the last 2010 campaign by a successful operation on the Full Active Multijunction (FAM) C3 antenna, with new performances: 3.5MW/40s on plasma. The RF output power control in amplitude and phase has been improved for a better control of the wave spectrum launched into the plasma. The new klystrons have no modulating anode and the high cathode voltage must be adjusted with the RF input power in order to optimize the RF output power with a minimization of the thermal power losses in the collector. A new phase correction, depending on the 3 RF output power ranges used, has been introduced. The improvements made in 2009 and 2010 on the generic phase loop and the procedures used during the real time tests of the RF transfer functions in amplitude and phase are detailed below. All RF measurements systems, RF safety systems and the RF calibration procedures have been revised in order to have the best consistency, reproducibility and with a measurement error against the calorimetry measurement lower than 10%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Minimization of Tracking Error for Aircraft Systems

This technology presents a novel, stable, discrete-time adaptive law for flight control in a Direct adaptive control (DAC) framework. Where errors are not present, the original control design has been tuned for optimal performance. Adaptive control works towards achieving nominal performance whenever the design has modeling uncertainties/errors or when the vehicle suffers substantial flight configuration change. The baseline controller uses dynamic inversion with proportional-integral augmentation. On-line adaptation of this control law is achieved by providing a parameterized augmentation signal to a dynamic inversion block. The parameters of this augmentation signal are updated to achieve the nominal desired error dynamics. If the system senses that at least one aircraft component is experiencing an excursion and the return of this component value toward its reference value is not proceeding according to the expected controller characteristics, then the neural network (NN) modeling of aircraft operation may be changed.

Garud, Sumedha↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Optimal space communications techniques

The design, development, and analysis are reported of a digital phase-locked loop (DPLL) for FM demodulation and threshold extension. One of the features of the developed DPLL is its synchronous, real time operation. The sampling frequency is constant and all the required arithmetic and logic operations are performed within one sampling period, generating an output sequence which is converted to analog form and filtered. An equation relating the sampling frequency to the carrier frequency must be satisfied to guarantee proper DPLL operation. The synchronous operation enables a time-shared operation of one DPLL to demodulate several FM signals simultaneously. In order to obtain information about the DPLL performance at low input signal-to-noise ratios, a model of an input noise spike was introduced, and the DPLL equation was solved using a digital computer. The spike model was successful in finding a second order DPLL which yielded a five db threshold extension beyond that of a first order DPLL.

Schilling, D. L.↗

Dispatch optimization of a concentrating solar power system under uncertain solar irradiance and energy prices

The integration of thermal energy storage into a concentrating solar power system allows for mitigating some of the risk associated with uncertain solar irradiance and uncertain energy prices. We solve a 48 h dispatch optimization model with continually updated conditional point forecasts of both direct normal irradiance (DNI) and electricity prices with a rolling-horizon scheme at hourly resolution over the course of a year. Joint, conditional forecasts for DNI and prices are formed using an autoregressive moving-average time series model with exogenous weather predictors. We guide dispatch using a mixed-integer programming model, but in order to evaluate performance we use the System Advisor Model (SAM) of the National Renewable Energy Laboratory. SAM is a techno-economic simulation model that accounts for plant thermodynamics with higher fidelity. Our conditional DNI forecasts improve annual revenue by 4%–12% over using historical forecasts based on data from previous years. Conditional price forecasts improve annual revenue by 6%–19% in the real-time market over analogous historical forecasts. Updating these forecasts every six hours, rather than every 24 h, further improves annual revenue by 5%–6%. Here, we also investigate a method that values terminal inventory in our dispatch optimization model, again when used in a rolling-horizon scheme.

14 SOLAR ENERGY↗