Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Uncertainty identification in mass estimation applications with imaging detectors

Mass quantification using standoff gamma imaging techniques is a boon to the special nuclear material holdup monitoring community, but before the method is deemed acceptable as a replacement for historical gamma detection-based methods, there are several considerable sources of uncertainty that must be addressed. These uncertainty sources have received sparse coverage in the literature, but provide the bulk of the uncertainty estimated in practice outside of standard counting statistics. For imaging, there is a fundamental difference between detection/localization and mass estimation operating modalities, where detection/localization can tolerate significantly larger uncertainty because the goal is detection of a distant source, rather than the quantification of that source. Historically, quantification requires a known geometry between source and detector, as well as a calibrated efficiency correction curve, which is well suited to laboratory practice for a stationary detector; however, this requires some corrections and assumptions (e.g., generalized geometry) for field applications, since additional degrees of freedom are present in the source-to-detector position, intervening materials, and non-uniform source distributions, when compared against the laboratory case. Use of an imaging detector during holdup measurements would address these issues by calculating the spatial geometry of the distant source as seen by the detector, with efficiency corrected according to the source-to-detector angle. While this aim promises a better estimation accuracy than generalized geometry assumptions, additional uncertainties are added from the imaging mechanism itself. Of these uncertainties, some are readily mitigated and methods to do so are included in the discussion, while some uncertainties are specific to the imaging class of instruments and are investigated and discussed in detail. Uncertainties are categorized into two general areas: instrument design and algorithmic. Instrument design-based uncertainties include basic detector characteristics for timing and energy resolution, handling of list mode data for coincidence detection, and geometric layout of and propagation of spatial uncertainty into imaging uncertainty. Algorithmic-based uncertainties discussed herein pertain to image reconstruction, the weight assignment problem from cone interactions, and the effects of spatial discretization on mass estimation. With these major sources of uncertainty identified, the path towards acceptance of imaging as a holdup monitoring method becomes clearer.

61 RADIATION PROTECTION AND DOSIMETRY↗

A concept for non-invasive temperature measurement during injection moulding processes

Current models of the injection moulding process insufficiently consider the thermal interactions between melt, solidified material and the mould. A detailed description requires a deep understanding of the underlying processes and a precise observation of the temperature. Because todays measurement concepts do not allow a non-invasive analysis it is necessary to find new measurement techniques for temperature measurements during the manufacturing process. In this work we present the idea of a set up for a tomographic ultrasound measurement of the temperature field inside a plastics melt. The goal is to identify a concept that can be installed on a specialized mould for the injection moulding process. The challenges are discussed and the design of a prototype is shown. Special attention is given to the spatial arrangement of the sensors. Besides the design of a measurement set up a reconstruction strategy for the ultrasound signals is required. We present an approach in which an image processing algorithm can be used to calculate a temperature distribution from the ultrasound scans. We discuss a reconstruction strategy in which the ultrasound signals are converted into a spartial temperature distribution by using pvT curves that are obtained by dilatometer measurements.

42 ENGINEERING↗

Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal recon struction in the ATLAS experiment. Topological cell clus tering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ~50% for jet p T ~ 20 GeV and by ~80% for jet p T ≳ 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < p T < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ-leptons), reducing the overall event size on disk by about 6% in early Run 3 pile up conditions. Offline reconstruction for Run 3 includes the timing requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Less is More: Bigger Data from Compressive Measurements

Compressive sensing approaches are beginning to take hold in (scanning) transmission electron microscopy (S/TEM) [1,2,3]. Compressive sensing is a mathematical theory about acquiring signals in a compressed form (measurements) and the probability of recovering the original signal by solving an inverse problem [4]. The inverse problem is underdetermined (more unknowns than measurements), so it is not obvious that recovery is possible. Compression is achieved by taking inner products of the signal with measurement weight vectors. Both Gaussian random weights and Bernoulli (0,1) random weights form a large class of measurement vectors for which recovery is possible. The measurements can also be designed through an optimization process. The key insight for electron microscopists is that compressive sensing can be used to increase acquisition speed and reduce dose. Building on work initially developed for optical cameras, this new paradigm will allow electron microscopists to solve more problems in the engineering and life sciences. We will be collecting orders of magnitude more data than previously possible. The reason that we will have more data is because we will have increased temporal/spatial/spectral sampling rates, and we will be able ability to interrogate larger classes of samples that were previously too beam sensitive to survive the experiment. For example consider an in-situ experiment that takes 1 minute. With traditional sensing, we might collect 5 images per second for a total of 300 images. With compressive sensing, each of those 300 images can be expanded into 10 more images, making the collection rate 50 images per second, and the decompressed data a total of 3000 images [3]. But, what are the implications, in terms of data, for this new methodology? Acquisition of compressed data will require downstream reconstruction to be useful. The reconstructed data will be much larger than traditional data, we will need space to store the reconstructions during analysis, and the computational demands for analysis will be higher. Moreover, there will be time costs associated with reconstruction. Deep learning [5] is an approach to address these problems. Deep learning is a hierarchical approach to find useful (for a particular task) representations of data. Each layer of the hierarchy is intended to represent higher levels of abstraction. For example, a deep model of faces might have sinusoids, edges and gradients in the first layer; eyes, noses, and mouths in the second layer, and faces in the third layer. There has been significant effort recently in deep learning algorithms for tasks beyond image classification such as compressive reconstruction [6] and image segmentation [7]. A drawback of deep learning, however, is that training the model requires large datasets and dedicated computational resources (to reduce training time to a few days). A second issue is that deep learning is not user-friendly and the meaning behind the results is usually not interpretable. We have shown it is possible to reduce the data set size while maintaining model quality [8] and developed interpretable models for image classification [9], but the demands are still significant. The key to addressing these problems is to NOT reconstruct the data. Instead, we should design computational sensors that give answers to specific problems. A simple version of this idea is compressive classification [10], where the goal is to classify signal type from a small number of compressed measurements. Classification is a much simpler problem than reconstruction, so 1) much fewer measurements will be necessary, and 2) these measurements will probably not be useful for reconstruction. Other simple examples of computational sensing include determining object volume or the number of objects present in the field of view [11].

Stevens, Andrew↗

Machine Learning Toolkit for Extreme Scale

Support Vector Machines (SVM) is a popular machine learning technique, which has been applied to a wide range of domains such as science, finance, and social networks for supervised learning. MaTEx undertakes the challenge of designing a scalable parallel SVM training algorithm for large scale systems, which includes commodity multi-core machines, tightly connected supercomputers and cloud computing systems. Several techniques are proposed for improved speed and memory space usage including adaptive and aggressive elimination of samples for faster convergence , and sparse format representation of data samples. Several heuristics for earliest possible to lazy elimination of non-contributing samples are considered in MaTEx. In many cases, where an early sample elimination might result in a false positive, low overhead mechanisms for reconstruction of key data structures are proposed. The proposed algorithm and heuristics are implemented and evaluated on various publicly available datasets

Source record↗

Machine Learning Toolkit for Extreme Scale

Support Vector Machines (SVM) is a popular machine learning technique, which has been applied to a wide range of domains such as science, finance, and social networks for supervised learning. MaTEx undertakes the challenge of designing a scalable parallel SVM training algorithm for large scale systems, which includes commodity multi-core machines, tightly connected supercomputers and cloud computing systems. Several techniques are proposed for improved speed and memory space usage including adaptive and aggressive elimination of samples for faster convergence , and sparse format representation of data samples. Several heuristics for earliest possible to lazy elimination of non-contributing samples are considered in MaTEx. In many cases, where an early sample elimination might result in a false positive, low overhead mechanisms for reconstruction of key data structures are proposed. The proposed algorithm and heuristics are implemented and evaluated on various publicly available datasets

Source record↗

Identification of tau leptons using a convolutional neural network with domain adaptation

A tau lepton identification algorithm,DeepTau, based on convolutional neural network techniques, has been developed in the CMS experiment to discriminate reconstructed hadronic decays of tau leptons (τ h ) from quark or gluon jets and electrons and muons that are misreconstructed as τ h candidates. The latest version of this algorithm, v2.5, includes domain adaptation by backpropagation, a technique that reduces discrepancies between collision data and simulation in the region with the highest purity of genuine τh candidates. Additionally, a refined training workflow improves classification performance with respect to the previous version of the algorithm, with a reduction of 30–50% in the probability for quark and gluon jets to be misidentified as τ h candidates for given reconstruction and identification efficiencies. This paper presents the novel improvements introduced in theDeepTau algorithm and evaluates its performance in LHC proton-proton collision data at √(s) = 13 and 13.6 TeV collected in 2018 and 2022 with integrated luminosities of 60 and 35 fb -1 , respectively. Techniques to calibrate the performance of the τ h identification algorithm in simulation with respect to its measured performance in real data are presented, together with a subset of results among those measured for use in CMS physics analyses.

Large detector-systems performance↗

SU-E-T-398: Evaluation of Radiobiological Parameters Using Serial Tumor Imaging During Radiotherapy as An Inverse Ill-Posed Problem

Purpose: Combination of serial tumor imaging with radiobiological modeling can provide more accurate information on the nature of treatment response and what underlies resistance. The purpose of this article is to improve the algorithms related to imaging-based radiobilogical modeling of tumor response. Methods: Serial imaging of tumor response to radiation therapy represents a sum of tumor cell sensitivity, tumor growth rates, and the rate of cell loss which are not separated explicitly. Accurate treatment response assessment would require separation of these radiobiological determinants of treatment response because they define tumor control probability. We show that the problem of reconstruction of radiobiological parameters from serial imaging data can be considered as inverse ill-posed problem described by the Fredholm integral equation of the first kind because it is governed by a sum of several exponential processes. Therefore, the parameter reconstruction can be solved using regularization methods. Results: To study the reconstruction problem, we used a set of serial CT imaging data for the head and neck cancer and a two-level cell population model of tumor response which separates the entire tumor cell population in two subpopulations of viable and lethally damage cells. The reconstruction was done using a least squared objective function and a simulated annealing algorithm. Using in vitro data for radiobiological parameters as reference data, we shown that the reconstructed values of cell surviving fractions and potential doubling time exhibit non-physical fluctuations if no stabilization algorithms are applied. The variational regularization allowed us to obtain statistical distribution for cell surviving fractions and cell number doubling times comparable to in vitro data. Conclusion: Our results indicate that using variational regularization can increase the number of free parameters in the model and open the way to development of more advanced algorithms which take into account tumor heterogeneity, for example, related to hypoxia.

60 APPLIED LIFE SCIENCES↗

Prostate brachytherapy postimplant dosimetry: Automatic plan reconstruction of stranded implants

Purpose: Plan reconstruction for permanent implant prostate brachytherapy is the process of determining the correspondence between planned and implanted seeds in postimplant analysis. Plan reconstruction informs many areas of brachytherapy quality assurance, including the verification of seed segmentation, misplacement and migration assessment, implant simulations, and the dosimetry of mixed-activity or mixed-species implants. Methods: An algorithm has been developed for stranded implants which uses the interseed spacing constraints imposed by the suture to improve the accuracy of reconstruction. Seventy randomly selected clinical cases with a mean of 23.6 (range 18-30) needles and mean density of 2.0 (range 1.6-2.6) 2.0 (range 1.6-2.6) seeds/cm{sup 3} were automatically reconstructed and the accuracy compared to manual reconstructions performed using a custom 3D graphical interface. Results: Using the automatic algorithm, the mean accuracy of the assignment relative to manual reconstruction was found to be 97.7{+-}0.5%. Fifty-two of the 70 cases (74%) were error-free; of seeds in the remaining cases, 96.7{+-}0.3% were found to be attributed to the correct strand and 97.0{+-}0.3% were correctly connected to their neighbors. Any necessary manual correction using the interface is usually straightforward. For the clinical data set tested, neither the number of seeds or needles, average density, nor the presence of clusters was found to have an effect on reconstruction accuracy using this method. Conclusions: Routine plan reconstruction of stranded implants can be performed with a high degree of accuracy to support postimplant dosimetry and quality analyses.

60 APPLIED LIFE SCIENCES↗

Fast transit portal dosimetry using density-scaled layer modeling of aSi-based electronic portal imaging device and Monte Carlo method

Purpose: Fast and accurate transit portal dosimetry was investigated by developing a density-scaled layer model of electronic portal imaging device (EPID) and applying it to a clinical environment. Methods: The model was developed for fast Monte Carlo dose calculation. The model was validated through comparison with measurements of dose on EPID using first open beams of varying field sizes under a 20-cm-thick flat phantom. After this basic validation, the model was further tested by applying it to transit dosimetry and dose reconstruction that employed our predetermined dose-response-based algorithm developed earlier. The application employed clinical intensity-modulated beams irradiated on a Rando phantom. The clinical beams were obtained through planning on pelvic regions of the Rando phantom simulating prostate and large pelvis intensity modulated radiation therapy. To enhance agreement between calculations and measurements of dose near penumbral regions, convolution conversion of acquired EPID images was alternatively used. In addition, thickness-dependent image-to-dose calibration factors were generated through measurements of image and calculations of dose in EPID through flat phantoms of various thicknesses. The factors were used to convert acquired images in EPID into dose. Results: For open beam measurements, the model showed agreement with measurements in dose difference better than 2% across open fields. For tests with a Rando phantom, the transit dosimetry measurements were compared with forwardly calculated doses in EPID showing gamma pass rates between 90.8% and 98.8% given 4.5 mm distance-to-agreement (DTA) and 3% dose difference (DD) for all individual beams tried in this study. The reconstructed dose in the phantom was compared with forwardly calculated doses showing pass rates between 93.3% and 100% in isocentric perpendicular planes to the beam direction given 3 mm DTA and 3% DD for all beams. On isocentric axial planes, the pass rates varied between 95.8% and 99.9% for all individual beams and they were 98.2% and 99.9% for the composite beams of the small and large pelvis cases, respectively. Three-dimensional gamma pass rates were 99.0% and 96.4% for the small and large pelvis cases, respectively. Conclusions: The layer model of EPID built for Monte Carlo calculations offered fast (less than 1 min) and accurate calculation for transit dosimety and dose reconstruction.

60 APPLIED LIFE SCIENCES↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Plug-and-Play Priors Approach for Solving Nonlinear Imaging Inverse Problems

In the past two decades, nonlinear image reconstruction methods have led to substantial improvements in the capabilities of numerous imaging systems. Such methods are traditionally formulated as optimization problems that are solved iteratively by simultaneously enforcing data consistency and incorporating prior models. Recently, the Plug-and-Play Priors (PPP) framework suggested that by using more sophisticated denoisers, not necessarily corresponding to an optimization objective, it is possible to improve the quality of reconstructed images. Here in this letter, we show that the PPP approach is applicable beyond linear inverse problems. In particular, we develop the fast iterative shrinkage/thresholding algorithm variant of PPP for model-based nonlinear inverse scattering. The key advantage of the proposed formulation over the original ADMM-based one is that it does not need to perform an inversion on the forward model. We show that the proposed method produces high quality images using both simulated and experimentally measured data.

97 MATHEMATICS AND COMPUTING↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Efficient ptychographic phase retrieval via a matrix-free Levenberg-Marquardt algorithm

The phase retrieval problem, where one aims to recover a complex-valued image from far-field intensity measurements, is a classic problem encountered in a range of imaging applications. Modern phase retrieval approaches usually rely on gradient descent methods in a nonlinear minimization framework. Calculating closed-form gradients for use in these methods is tedious work, and formulating second order derivatives is even more laborious. Additionally, second order techniques often require the storage and inversion of large matrices of partial derivatives, with memory requirements that can be prohibitive for data-rich imaging modalities. We use a reverse-mode automatic differentiation (AD) framework to implement an efficient matrix-free version of the Levenberg-Marquardt (LM) algorithm, a longstanding method that finds popular use in nonlinear least-square minimization problems but which has seen little use in phase retrieval. Furthermore, we extend the basic LM algorithm so that it can be applied for more general constrained optimization problems (including phase retrieval problems) beyond just the least-square applications. Since we use AD, we only need to specify the physics-based forward model for a specific imaging application; the first and second-order derivative terms are calculated automatically through matrix-vector products, without explicitly forming the large Jacobian or Gauss-Newton matrices typically required for the LM method. We demonstrate that this algorithm can be used to solve both the unconstrained ptychographic object retrieval problem and the constrained “blind” ptychographic object and probe retrieval problems, under the popular Gaussian noise model as well as the Poisson noise model. We compare this algorithm to state-of-the-art first order ptychographic reconstruction methods to demonstrate empirically that this method outperforms best-in-class first-order methods: it provides excellent convergence guarantees with (in many cases) a superlinear rate of convergence, all with a computational cost comparable to, or lower than, the tested first-order algorithms.

36 MATERIALS SCIENCE↗

Sensitivity of modelled passive margin stratigraphy to variations in sea level, sediment supply and subsidence

Abstract We produced a 10 Myr synthetic stratigraphic section using a forward stratigraphic model that generates marine deltaic stratigraphy over geological timescales. We recursively fit the model using a Bayesian inversion algorithm to test: (1) if it could be accurately reconstructed; (2) if the parameters used to create it could be recovered; and (3) the sensitivity of the model output to given model parameters and the attendant physical processes. The original synthetic stratigraphic section was produced with cyclical sea‐level variations of 40 and 30 m with 2.4 and 10 Myr periods respectively. Sediment was also supplied cyclically, in 2.4 and 10 Myr cycles with amplitudes of 30 and 80 tons/100 kyr, respectively, varying from a mean of 232 tons/100 kyr. Parameter values were sampled to fit the model using a Markov chain Monte Carlo algorithm, resulting in a ±5 m (1σ) variation between the experimental output and the original. Sea level varied by ±7 m (1σ) within the posterior distribution of parameters. As a result, both the 10 Myr and 2.4 Myr sea‐level cycles could be extracted from the original output. The variation in sediment supply was approximately ±38 tons/100 kyr (1σ) and, as a result, only the larger long‐term supply variations could be accurately recovered in refitting the model. The variation in thermal, flexural and total subsidence across those parameter sets is less than ±10 m (1σ). The original section experienced 150 m of total subsidence at the depocentre. Our results demonstrate the distinct and interpretable imprint of sea level and subsidence on continental margin stratigraphy can be quantified. Moreover, we conclude that sea‐level change produces a defined effect on the geometries of stratigraphic architecture, and that techniques applied for the purpose of delineating sea‐level variation from continental margin strata have a well‐founded conceptual basis.

Schmelz, William J.↗

Investigation of statistical iterative reconstruction for dedicated breast CT

Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-209: Verification of 3D Surface Registration Between Stereograms and CT Images

Purpose: Stereography can provide a visualization of the skin surface for radiation therapy patients. The aim of this study was to verify the registration algorithm in a commercial image analysis software, 3dMDVultus, for the fusion of stereograms and CT images. Methods: CT and stereographic scans were acquired of a head phantom and a deformable phantom. CT images were imported in 3dMDVultus and the surface contours were generated by threshold segmentation. Stereograms were reconstructed in 3dMDVultus. The resulting surfaces were registered with Vultus algorithm and then exported to in-house registration software and compared with four algorithms: rigid, affine, non-rigid iterative closest point (ICP) and b-spline algorithm. RMS (root-mean-square residuals of the surface point distances) error between the registered CT and stereogram surfaces was calculated and analyzed. Results: For the head phantom, the maximum RMS error between registered CT surfaces to stereogram was 6.6 mm for Vultus algorithm, whereas the mean RMS error was 0.7 mm. For the deformable phantom, the maximum RMS error was 16.2 mm for Vultus algorithm, whereas the mean RMS error was 4.4 mm. Non-rigid ICP demonstrated the best registration accuracy, as the mean of RMS errors were both within 1 mm. Conclusion: The accuracy of registration algorithm in 3dMDVultus was verified and exceeded RMS of 2 mm for deformable cases. Non-rigid ICP and b-spline algorithms improve the registration accuracy for both phantoms, especially in deformable one. For those patients whose body habitus deforms during radiation therapy, more advanced nonrigid algorithms need to be used.

60 APPLIED LIFE SCIENCES↗

Joint iterative reconstruction and 3D rigid alignment for X-ray tomography

X-ray tomography is widely used for three-dimensional structure determination in many areas of science, from the millimeter to the nanometer scale. The resolution and quality of the 3D reconstruction is limited by the availability of alignment parameters that correct for the mechanical shifts of the sample or sample stage for the images that constitute a scan. In this paper we describe an algorithm for marker-free, fully automated and accurately aligned and reconstructed X-ray tomography data. Our approach solves the tomographic reconstruction jointly with projection data alignment based on a rigid-body deformation model. We demonstrate the robustness of our method on both synthetic phantom and experimental data and show that our method is highly efficient in recovering relatively large alignment errors without prior knowledge of a low resolution approximation of the 3D structure or a reasonable estimate of alignment parameters.

36 MATERIALS SCIENCE↗