Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Thermomechanical Methodology for Stabilizing Shape Memory Alloy (SMA) Response

Methods and apparatuses for stabilizing the strain-temperature response for a shape memory alloy are provided. To perform stabilization of a second sample of the shape memory alloy, a first sample of the shape memory alloy is selected for isobaric treatment and the second sample is selected for isothermal treatment. When applying the isobaric treatment to the first sample, a constant stress is applied to the first sample. Temperature is also cycled from a minimum temperature to a maximum temperature until a strain on the first sample stabilizes. Once the strain on the first sample stabilizes, the isothermal treatment is performed on the second sample. During isothermal treatment, different levels of stress on the second sample are applied until a strain on the second sample matches the stabilized strain on the first sample.

Padula, Santo A., II↗

Thermomechanical Methodology for Stabilizing Shape Memory Alloy (SMA) Response

Methods and apparatuses for stabilizing the strain-temperature response for a shape memory alloy are provided. To perform stabilization of a second sample of the shape memory alloy, a first sample of the shape memory alloy is selected for isobaric treatment and the second sample is selected for isothermal treatment. When applying the isobaric treatment to the first sample, a constant stress is applied to the first sample. Temperature is also cycled from a minimum temperature to a maximum temperature until a strain on the first sample stabilizes. Once the strain on the first sample stabilizes, the isothermal treatment is performed on the second sample. During isothermal treatment, different levels of stress on the second sample are applied until a strain on the second sample matches the stabilized strain on the first sample.

Padula, Santo A., II↗

Surface roughness effects on bidirectional reflectance

An experimental study of surface roughness effects on bidirectional reflectance of metallic surfaces is presented. A facility capable of irradiating a sample from normal to grazing incidence and recording plane of incidence bidirectional reflectance measurements was developed. Samples consisting of glass, aluminum alloy, and stainless steel materials were selected for examination. Samples were roughened using standard grinding techniques and coated with a radiatively opaque layer of pure aluminum. Mechanical surface roughness parameters, rms heights and rms slopes, evaluated from digitized surface profile measurements are less than 1.0 micrometers and 0.28, respectively. Rough surface specular, bidirectional, and directional reflectance measurements for selected values of polar angle of incidence and wavelength of incident energy within the spectral range of 1 to 14 micrometers are reported. The Beckmann bidirectional reflectance model is compared with reflectance measurements to establish its usefulness in describing the magnitude and spatial distribution of energy reflected from rough surfaces.

Smith, T. F.↗

Development of taste sensor system for differentiation of Indonesian herbal medicines

In Indonesia, herbal medicines are usually produced by small and medium enterprises which are relatively low in quality control. The purpose of this paper is to report that we have developed a taste sensor system with global selectivity, i.e., electronic tongue (e-tongue) for differentiation of Indonesian herbal medicines. The e-tongue was composed of five kinds of ion selective electrodes as working electrodes, data acquisition system, and pattern recognition system. Each ion selective electrode (ISE) was built by attaching lipid/polymer membrane. For this purpose, the five kinds of membranes were built by mixing lipid, plasticizer (nitrophenyl octyl ether/NPOE), polyvinyl chloride (PVC), and tetrahydrofuran (THF). In this study, we employed five kinds of lipid, namely oleic acid (OA), dioctyl phosphate (DOP), decyl alcohol (DA), dodecylamine (DDC), and trioctyl methyl ammonium chloride (TOMA). In this case, the membranes transform information of taste substances into electric signal. The five kinds of Indonesian herbal medicine were purchased from local supermarket in Yogyakarta, i.e., kunyit asam (made from turmeric and tamarind), beras kencur (made from rice and kencur), jahe wangi (made from ginger and fragrance), sirih wangi (made from betel leaf), and temulawak (made from Javanese ginger). Prior to detecting the taste from the Indonesian herbal medicine samples, each ion selective electrode was tested with five basic taste samples, i.e., for saltiness, sweetness, umami, bitterness, and sourness. All ISEs showed global selectivity to all samples. Furthermore, the array of ISEs showed specific response pattern to each Indonesian herbal medicine. For pattern recognition system, we employed principle component analysis (PCA). As a result, the e-tongue was able to differentiate five kinds of Indonesian herbal medicines, proven by the total variance of first and second principle components is about 93%. For the future, the e-tongue may be developed for quality control application in herbal medicine industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport properties of damaged materials. Cementitious barriers partnership

The objective of the Cementitious Barriers Partnership (CBP) project is to develop tools to improve understanding and prediction of the long-term structural, hydraulic, and chemical performance of cementitious barriers used in low-level waste storage applications. One key concern for the long-term durability of concrete is the degradation of the cementitious matrix, which occurs as a result of aggressive chemical species entering the material or leaching out in the environment, depending on the exposure conditions. The objective of the experimental study described in this report is to provide experimental data relating damage in cementitious materials to changes in transport properties, which can eventually be used to support predictive model development. In order to get results within a reasonable timeframe and to induce as much as possible uniform damage level in materials, concrete samples were exposed to freezing and thawing (F/T) cycles. The methodology consisted in exposing samples to F/T cycles and monitoring damage level with ultrasonic pulse velocity measurements. Upon reaching pre-selected damage levels, samples were tested to evaluate changes in transport properties. Material selection for the study was motivated by the need to get results rapidly, in order to assess the relevance of the methodology. Consequently, samples already available at SIMCO from past studies were used. They consisted in three different concrete mixtures cured for five years in wet conditions. The mixtures had water-to-cement ratios of 0.5, 0.65 and 0.75 and were prepared with ASTM Type I cement only. The results showed that porosity is not a good indicator for damage caused by the formation of microcracks. Some materials exhibited little variations in porosity even for high damage levels. On the other hand, significant variations in tortuosity were measured in all materials. This implies that damage caused by internal pressure does not necessarily create additional pore space in the microstructure, but likely creates new thin pathways between existing pore space for species to travel. These results have a significant impact on modeling efforts. Models relating porosity to tortuosity and permeability are unlikely to provide the correct basis for predicting long-term durability of concrete sustaining internal pressures and microcrack formation. Other avenues like the modeling of internal crystallization pressure need to be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the W boson helicity in top quark decays using 5.4 fb⁻¹ of pp̄ collision data

We present a measurement of the helicity of the W boson produced in top quark decays using tt¯ decays in the l+jets and dilepton final states selected from a sample of 5.4 fb⁻¹ of collisions recorded using the D0 detector at the Fermilab Tevatron pp̄ collider. We measure the fractions of longitudinal and right-handed W bosons to be f₀=0.669±0.102[±0.078(stat.)±0.065(syst.)] and f₊=0.023±0.053[±0.041(stat.)±0.034(syst.)], respectively. This result is consistent at the 98% level with the standard model. A measurement with f₀ fixed to the value from the standard model yields f₊=0.010±0.037[±0.022(stat.)±0.030(syst.)].

Abazov, V. M.↗

The Fraction of Cool-core Clusters in X-Ray versus SZ Samples Using Chandra Observations

We derive and compare the fractions of cool-core clusters in the Planck Early Sunyaev–Zel’dovich sample of 164 clusters with z⩽0.35 and in a flux-limited X-ray sample of 100 clusters with z⩽0.30, using Chandra observations. We use four metrics to identify cool-core clusters: (1) the concentration parameter, which is the ratio of the integrated emissivity profile within 0.15 r {sub 500} to that within r {sub 500}; (2) the ratio of the integrated emissivity profile within 40 kpc to that within 400 kpc; (3) the cuspiness of the gas density profile, which is the negative of the logarithmic derivative of the gas density with respect to the radius, measured at 0.04 r {sub 500}; and (4) the central gas density, measured at 0.01 r {sub 500}. We find that the sample of X-ray-selected clusters, as characterized by each of these metrics, contains a significantly larger fraction of cool-core clusters compared to the sample of SZ-selected clusters (44% ± 7% versus 28% ± 4% using the concentration parameter in the 0.15–1.0 r {sub 500} range, 61% ± 8% versus 36% ± 5% using the concentration parameter in the 40–400 kpc range, 64% ± 8% versus 38% ± 5% using the cuspiness, and 53% ± 7% versus 39 ± 5% using the central gas density). Qualitatively, cool-core clusters are more X-ray luminous at fixed mass. Hence, our X-ray, flux-limited sample, compared to the approximately mass-limited SZ sample, is overrepresented with cool-core clusters. We describe a simple quantitative model that uses the excess luminosity of cool-core clusters compared to non-cool-core clusters at fixed mass to successfully predict the observed fraction of cool-core clusters in X-ray-selected samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser dissection sampling modes for direct mass spectral analysis [using a hybrid optical microscopy/laser ablation liquid vortex capture/electrospray ionization system

Here, laser microdissection coupled directly with mass spectrometry provides the capability of on-line analysis of substrates with high spatial resolution, high collection efficiency, and freedom on shape and size of the sampling area. Establishing the merits and capabilities of the different sampling modes that the system provides is necessary in order to select the best sampling mode for characterizing analytically challenging samples. The capabilities of laser ablation spot sampling, laser ablation raster sampling, and laser 'cut and drop' sampling modes of a hybrid optical microscopy/laser ablation liquid vortex capture electrospray ionization mass spectrometry system were compared for the analysis of single cells and tissue. Single Chlamydomonas reinhardtii cells were monitored for their monogalactosyldiacylglycerol (MGDG) and diacylglyceryltrimethylhomo-Ser (DGTS) lipid content using the laser spot sampling mode, which was capable of ablating individual cells (4-15 m) even when agglomerated together. Turbid Allium Cepa cells (150 m) having unique shapes difficult to precisely measure using the other sampling modes could be ablated in their entirety using laser raster sampling. Intact microdissections of specific regions of a cocaine-dosed mouse brain tissue were compared using laser 'cut and drop' sampling. Since in laser 'cut and drop' sampling whole and otherwise unmodified sections are captured into the probe, 100% collection efficiencies were achieved. Laser ablation spot sampling has the highest spatial resolution of any sampling mode, while laser ablation raster sampling has the highest sampling area adaptability of the sampling modes. In conclusion, laser ablation spot sampling has the highest spatial resolution of any sampling mode, useful in this case for the analysis of single cells. Laser ablation raster sampling was best for sampling regions with unique shapes that are difficult to measure using other sampling modes. Laser 'cut and drop' sampling can be used for cases where the highest sensitivity is needed, for example, monitoring drugs present in trace amounts in tissue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Antibacterial and Structural Properties and Printability of Starch/Clay/Polyethylene Composite Films

A composite of thermoplastic starch (TPS), low-density polyethylene (LDPE) and citric acid-modified montmorillonite (CMMT) was prepared in a twin screw extruder for packaging film application. Starch was first converted to the thermoplastic state by using sorbitol and water. Composite films were produced on a chill roll system and then were modified for printability by grafting of acrylonitrile onto the starch backbone. Antimicrobial property and printability of the films were studied from which the sample with the highest antimicrobial property and the best printability was selected. This optimal sample was then characterized by Fourier transform infrared, thermal gravimetric analysis, differential scanning calorimetry, X-ray diffraction, and scanning electron microscopy. The composite film showed a matrix/dispersed morphology in which LDPE formed a continuous phase and TPS/CMMT nanocomposite particles appeared as dispersed phase. Biodegradability, water absorption, oxygen permeability, tensile strength and transparency of optimal film were also studied. The results indicated very good properties of the produced composite film for packaging application. Graphical Abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesis, phase composition modification, and optical properties of Ce{sup 3+}/Tb{sup 3+} activated KGdF{sub 4} and GdF{sub 3} submicrocrystals

Ce{sup 3+}/Tb{sup 3+} co-doped series of samples have been synthesized based on a citric acid assisted hydrothermal method. By controlling the hydrothermal treating time, the samples evolve from the Ce{sup 3+}/Tb{sup 3+} co-doped cubic phase KGdF{sub 4} with spherical morphology into the Ce{sup 3+}/Tb{sup 3+} co-doped orthorhombic phase GdF{sub 3} with rhombic shape finally. The X-ray diffraction data illustrate the phase composition modification process of the samples. The field emission scanning electron microscopy and the transmission electron microscopy images suggest the transformation in the morphology of final products. The spectra of the energy-dispersive spectroscopy reveal the constituents of the samples. And the selected area electronic diffraction patterns prove the crystalline phases of the samples. Based on previous studies and the experimental data, one possible phase composition modification process has been summarized. The photoluminescence excitation and emission spectra and the luminescent dynamic decay curves demonstrate the variations in optical properties of the Ce{sup 3+}/Tb{sup 3+} co-doped final products. - Graphical abstract: Schematic illustration for the phase composition modification from the Ce{sup 3+}/Tb{sup 3+} doped KGdF{sub 4} to the Ce{sup 3+}/Tb{sup 3+}doped GdF{sub 3} with multiform morphologies and different sizes. (C presents cubic phase, H presents hexagonal phase, and O presents orthorhombic phase.) Highlights: Black-Right-Pointing-Pointer The samples were synthesized by a hydrothermal method. Black-Right-Pointing-Pointer The samples evolved from the cubic phase KGdF{sub 4} into the orthorhombic phase GdF{sub 3}. Black-Right-Pointing-Pointer The morphology evolved from the spherical shape into the rhombic shape finally. Black-Right-Pointing-Pointer A possible phase composition modification process was summarized. Black-Right-Pointing-Pointer The optical properties of final products were compared and studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparisons of classical and Wigner sampling of transition state energy levels for quasiclassical trajectory chemical dynamics simulations

Quasiclassical trajectory calculations are compared, with classical and Wigner sampling of transition state (TS) energy levels, for C{sub 2}H{sub 5}F{sup {ne}{yields}H}F+C{sub 2}H{sub 4} product energy partitioning and [Cl{center_dot}{center_dot}{center_dot}CH{sub 3}{center_dot}{center_dot}{center_dot}Cl]{sup -} central barrier dynamics. The calculations with Wigner sampling are reported here for comparison with the previously reported calculations with classical sampling [Y. J. Cho et al., J. Chem. Phys. 96, 8275 (1992); L. Sun and W. L. Hase, J. Chem. Phys. 121, 8831 (2004)]. The C{sub 2}H{sub 5}F{sup {ne}} calculations were performed with direct dynamics at the MP2/6-31G* level of theory. Classical and Wigner sampling give post-transition state dynamics, for these two chemical systems, which are the same within statistical uncertainties. This is a result of important equivalences in these two sampling methods for selecting initial conditions at a TS. In contrast, classical and Wigner sampling often give different photodissociation dynamics [R. Schinke, J. Phys. Chem. 92, 3195 (1988)]. Here the sampling is performed for a vibrational state of the ground electronic state potential energy surface (PES), which is then projected onto the excited electronic state's PES. Differences between the ground and the excited PESs may give rise to substantially different excitations of the vibrational and dissociative coordinates on the excited state PES by classical and Wigner sampling, resulting in different photodissociation dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS): Spectral Maps of the Asteroid Bennu

The OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) is a point spectrometer covering the spectral range of 0.4 to 4.3 microns (25,000-2300 cm−1). Its primary purpose is to map the surface composition of the asteroid Bennu, the target asteroid of the OSIRIS-REx asteroid sample return mission. The information it returns will help guide the selection of the sample site. It will also provide global context for the sample and high spatial resolution spectra that can be related to spatially unresolved terrestrial observations of asteroids. It is a compact, low-mass (17.8 kg), power efficient (8.8 W average), and robust instrument with the sensitivity needed to detect a 5% spectral absorption feature on a very dark surface (3% reflectance) in the inner solar system (0.89-1.35 AU). It, in combination with the other instruments on the OSIRIS-REx Mission, will provide an unprecedented view of an asteroid's surface.

Reuter, D. C.↗

An integrated portable Raman sensor with nanofabricated gold bowtie array substrates for energetics detection

An integrated field-portable surface enhaned Raman scattering (SERS) sensing system has been developed and evaluated for quantitative analysis of energetics such as perchlorate (ClO4-) and trinitrotoluene (TNT) at environmentally-relevant concentrations and conditions. The detection system consists of a portable Raman spectrometer equipped with an optical fiber probe that is coupled with novel elevated gold bowtie nanostructural arrays as a sensitive and reproducible SERS substrate. Using the standard addition technique, we show that ClO4- and TNT can be quantified at concentrations as low as 0.66 mg/L (or ~6.6 M) and 0.20 mg/L (~0.9 M), respectively, in groundwater samples collected from selected military sites. This research represents the first step toward the development of a field SERS sensor which may permit rapid, in-situ screening and analysis for various applications including national security, chemical, biological and environmental detection.

Abu Hatab, Nahla A↗

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

Study of B to pi l nu and B to rho l nu Decays and Determination of |V_ub|

We present an analysis of exclusive charmless semileptonic B-meson decays based on 377 million B{bar B} pairs recorded with the BABAR detector at the {Upsilon} (4S) resonance. We select four event samples corresponding to the decay modes B{sup 0} {yields} {pi}{sup -}{ell}{sup +}{nu}, B{sup +} {yields} {pi}{sup 0}{ell}{sup +}{nu}, B{sup 0} {yields} {rho}{sup -}{ell}{sup +}{nu}, and B{sup +} {yields} {rho}{sup 0}{ell}{sup +}{nu}, and find the measured branching fractions to be consistent with isospin symmetry. Assuming isospin symmetry, we combine the two B {yields} {pi}{ell}{nu} samples, and similarly the two B {yields} {rho}{ell}{nu} samples, and measure the branching fractions {Beta}(B{sup 0} {yields} {pi}{sup -}{ell}{sup +}{nu}) = (1.41 {+-} 0.05 {+-} 0.07) x 10{sup -4} and {Beta}(B{sup 0} {yields} {rho}{sup 0}{ell}{sup +}{nu}) = (1.75 {+-} 0.15 {+-} 0.27) x 10{sup -4}, where the errors are statistical and systematic. We compare the measured distribution in q{sup 2}, the momentum transfer squared, with predictions for the form factors from QCD calculations and determine the CKM matrix element |V{sub ub}|. Based on the measured partial branching fraction for B {yields} {pi}{ell}{nu} in the range q{sup 2} < 12 GeV{sup 2} and the most recent LCSR calculations we obtain |V{sub ub}| = (3.78 {+-} 0.13{sub -0.40}{sup +0.55}) x 10{sup -3}, where the errors refer to the experimental and theoretical uncertainties. From a simultaneous fit to the data over the full q{sup 2} range and the FNAL/MILC lattice QCD results, we obtain |V{sub ub}| = (2.95 {+-} 0.31) x 10{sup -3} from B {yields} {pi}{ell}{nu}, where the error is the combined experimental and theoretical uncertainty.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗