Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Microscintigraphy with high resolution collimators and radiographic detectors

The potential use of high resolution collimators with standard radiographic detectors in place of conventional gamma cameras for high resolution microscintigraphy is presented. Polycapillary multiple hole collimators are shown to provide 10-100 micron scale spatial resolution. A series of images from arrays of {sup 125}I brachytherapy seeds in Lucite phantoms display resolution better than 0.1 mm with good sensitivity and a 30 mm field of view. In addition to application to brachytherapy seed localization, such ''cellular'' level resolution is necessary for high-resolution in vivo imaging in mouse models. The system could also enable the use of a wider variety of isotopes, including much lower photon energy isotopes in nuclear medicine, as the high resolution collimator allows more flexibility in detector constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HIGH-RESOLUTION HELIOSEISMIC IMAGING OF SUBSURFACE STRUCTURES AND FLOWS OF A SOLAR ACTIVE REGION OBSERVED BY HINODE

We analyze a solar active region observed by the Hinode Ca II H line using the time-distance helioseismology technique, and infer wave-speed perturbation structures and flow fields beneath the active region with a high spatial resolution. The general subsurface wave-speed structure is similar to the previous results obtained from Solar and Heliospheric Observatory/Michelson Doppler Imager observations. The general subsurface flow structure is also similar, and the downward flows beneath the sunspot and the mass circulations around the sunspot are clearly resolved. Below the sunspot, some organized divergent flow cells are observed, and these structures may indicate the existence of mesoscale convective motions. Near the light bridge inside the sunspot, hotter plasma is found beneath, and flows divergent from this area are observed. The Hinode data also allow us to investigate potential uncertainties caused by the use of phase-speed filter for short travel distances. Comparing the measurements with and without the phase-speed filtering, we find out that inside the sunspot, mean acoustic travel times are in basic agreement, but the values are underestimated by a factor of 20%-40% inside the sunspot umbra for measurements with the filtering. The initial acoustic tomography results from Hinode show a great potential of using high-resolution observations for probing the internal structure and dynamics of sunspots.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of signal diffusion on x-ray phase contrast images

We discuss the problem of signal diffusion among neighbouring pixels in x-ray phase contrast imaging (XPCi) specifically for coded-aperture (CA) XPCi, but many of the discussed observations are directly transferable to other XPCi modalities. CA XPCi exploits the principle of pixel edge illumination by means of two CA masks. The first mask, placed in contact with the detector, creates insensitive regions between adjacent pixels; the second one, placed immediately before the sample, creates individual beams impinging on the boundaries between sensitive and insensitive regions on the detector, as created by the detector mask. In this way, edge illumination is achieved for all pixels of an area detector illuminated by a divergent and polychromatic beam generated by a conventional source. As the detector mask redefines the resolution properties of the detector, sample dithering can be used to effectively increase the system spatial resolution, without having to apply any post-processing procedure (e.g., deconvolution). This however creates artifacts in the form of secondary fringes (which have nothing to do with phase-related secondary fringes) if there is signal diffusion between adjacent pixels. In non-dithered images, signal diffusion between adjacent pixels causes a reduction in image contrast. This effect is investigated both theoretically and experimentally, and its direct implications on image quality are discussed. The interplay with the sample positioning with respect to the detector pixel matrix, which also has an effect on the obtained image contrast, is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IONIZED GAS KINEMATICS AT HIGH RESOLUTION. V. [Ne ii], MULTIPLE CLUSTERS, HIGH EFFICIENCY STAR FORMATION, AND BLUE FLOWS IN HE 2–10

We measured the 12.8 μm [Ne ii] line in the dwarf starburst galaxy He 2–10 with the high-resolution spectrometer TEXES on the NASA IRTF. The data cube has a diffraction-limited spatial resolution of ∼1″ and a total velocity resolution, including thermal broadening, of ∼5 km s{sup −1}. This makes it possible to compare the kinematics of individual star-forming clumps and molecular clouds in the three dimensions of space and velocity, and allows us to determine star formation efficiencies. The kinematics of the ionized gas confirm that the starburst contains multiple dense clusters. From the M/R of the clusters and the ≃30%–40% star formation efficiencies, the clusters are likely to be bound and long lived, like globulars. Non-gravitational features in the line profiles show how the ionized gas flows through the ambient molecular material, as well as a narrow velocity feature, which we identify with the interface of the H ii region and a cold dense clump. These data offer an unprecedented view of the interaction of embedded H ii regions with their environment.

79 ASTRONOMY AND ASTROPHYSICS↗

Superresolution Full-polarimetric Imaging for Radio Interferometry with Sparse Modeling

We propose a new technique for radio interferometry to obtain superresolution full-polarization images in all four Stokes parameters using sparse modeling. The proposed technique reconstructs the image in each Stokes parameter from the corresponding full-complex Stokes visibilities by utilizing two regularization functions: the ℓ {sub 1} norm and the total variation (TV) of the brightness distribution. As an application of this technique, we present simulated linear polarization observations of two physically motivated models of M87 with the Event Horizon Telescope. We confirm that ℓ {sub 1}+TV regularization can achieve an optimal resolution of ~25%–30% of the diffraction limit λ/D{sub max}, which is the nominal spatial resolution of a radio interferometer for both the total intensity (i.e., Stokes I) and linear polarizations (i.e., Stokes Q and U). This optimal resolution is better than that obtained from the widely used Cotton–Schwab CLEAN algorithm or from using ℓ {sub 1} or TV regularizations alone. Furthermore, we find that ℓ {sub 1}+TV regularization can achieve much better image fidelity in linear polarization than other techniques over a wide range of spatial scales, not only in the superresolution regime, but also on scales larger than the diffraction limit. Our results clearly demonstrate that sparse reconstruction is a useful choice for high-fidelity full-polarimetric interferometric imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Validity of the line-pair bar-pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imaging

The measurement of the modulation transfer function (MTF) of an imaging device is a common requirement in evaluating radiographic detector performance. Such measurements are considered mandatory in detector development research, and may also be carried out as part of routine quality assurance (QA) checks of image quality. Traditionally, MTF measurement has been performed by imaging either a narrow slit or a sharp edge in order to generate a line spread function, whose Fourier transform provides the MTF on a near-continuous frequency domain. Much less commonly employed is the method of square-wave line-pair modulations, in which the modulation response to bar resolution targets contained in a bar pattern is used to estimate the MTF at discrete spatial frequencies. While the slit and edge methods offer advantages of accuracy and a well-known standardized protocol for measurement based on several decades of development, their major limitation is the difficult and time-consuming experimental setup that is necessary to ensure accurate measurements. On the other hand, the bar pattern offers the advantage of a quick, simple, and easy measurement without the need for a complex experimental setup, with the main disadvantages of the technique being a pseudo-normalization that may lead to an overestimated MTF, and corrections for removing higher-order frequency harmonics that require interpolating between discrete spatial frequencies. Therefore, bar patterns are traditionally used for qualitative imaging applications like detector QA in terms of relative and arbitrarily defined spatial resolution metrics, while slit and edge methods are preferred for quantitative MTF measurements. Compared to diagnostic x rays, MTF measurements using megavoltage x rays are further complicated by low x-ray attenuation and excessive Compton scattering. In this work, a method to measure the MTF of megavoltage x-ray detectors based on imaging square-wave line pairs with improved near-zero-frequency normalization was developed as an adaptation to previously reported methods. Monte Carlo simulations were used to identify an improved normalization condition with which the accuracy of the MTF determined from line-pair modulations could be enhanced considerably compared to previously used techniques. Slit, edge, and bar-pattern measurements were performed to obtain the MTF of commercial megavoltage imaging devices including portal film and electronic portal imaging devices. A comparison of the MTF measurements from the three techniques was used to ascertain the validity of the proposed bar-pattern method for accurate and reliable measurement of MTF for megavoltage imagers. Statistical analyses revealed no significant differences between the bar-pattern method and the standard slit and edge techniques, indicating very good agreement (mean difference within {+-}3%). These results indicated the potential for line-pair bar patterns to be used more effectively than in the past for traditional QA imaging as well as for quantitative MTF measurement in detector development research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Liquid helium inertial jet for comparative study of classical and quantum turbulence

We present a new cryogenic wind tunnel facility developed to study the high Reynolds number developed classical or quantum turbulence in liquid {sup 4}He. A stable inertial round jet flow with a Reynolds number of 4 x 10{sup 6} can be sustained in both He I and He II down to a minimum temperature of 1.7 K. The circuit can be pressurized up to 3.5 x 10{sup 5} Pa. The system has been designed to exploit the self-similar properties of the jet far field in order to adapt to the spatial resolution of the existing probes. Multiple and complementary sensors can be simultaneously installed to obtain spatial and time resolved measurements. The technical difficulties and design details are described and the system performance is presented.

42 ENGINEERING↗

An in situ runaway electron diagnostic for DIII-D

We are designing a new diagnostic based on laser inverse Compton scattering to study the dynamics of runaway electron formation during killer-pellet triggered disruptions in DIII-D, and their subsequent loss. We can improve the expected S/N ratio by using a high-intensity short-pulse laser combined with gated x-ray imagers. With 80 ps sampling, time-of-flight spatial resolution within the laser chord can be obtained. We will measure the time-resolved spatial profile and energy distribution of the runaway electrons while they are in the core of the tokamak plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and characterization of a 320-slice volumetric CT scanner for simulation in radiation oncology

Purpose: Effective target definition and broad employment of treatment response assessment with dynamic contrast-enhanced CT in radiation oncology requires increased speed and coverage for use within a single bolus injection. To this end, a novel volumetric CT scanner (Aquilion One, Toshiba, Tochigi Pref., Japan) has been installed at the Princess Margaret Hospital for implementation into routine CT simulation. This technology offers great advantages for anatomical and functional imaging in both scan speed and coverage. The aim of this work is to investigate the system's imaging performance and quality as well as CT quantification accuracy which is important for radiotherapy dose calculations. Methods: The 320-slice CT scanner uses a 160 mm wide-area (2D) solid-state detector design which provides the possibility to acquire a volumetric axial length of 160 mm without moving the CT couch. This is referred to as ''volume'' and can be scanned with a rotation speed of 0.35-3 s. The scanner can also be used as a 64-slice CT scanner and perform conventional (axial) and helical acquisitions with collimation ranges of 1-32 and 16-32 mm, respectively. Commissioning was performed according to AAPM Reports TG 66 and 39 for both helical and volumetric imaging. Defrise and other cone-beam image analysis tests were performed. Results: Overall, the imaging spatial resolution and geometric efficiency (GE) were found to be very good (>10 lp/mm, <1 mm spatial integrity and GE{sub 160mm}=85%) and within the AAPM guidelines as well as IEC recommendations. Although there is evidence of some cone-beam artifacts when scanning the Defrise phantom, image quality was found to be good and sufficient for treatment planning (soft tissue noise <10 HU). Measurements of CT number stability and contrast-to-noise values across the volume indicate clinically acceptable scan accuracy even at the field edge. Conclusions: Initial experience with this exciting new technology confirms its accuracy for routine CT simulation within radiation oncology and allows for future investigations into specialized dynamic volumetric imaging applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

60 APPLIED LIFE SCIENCES↗

FY08 LDRD Final Report Regional Climate

An integrated, multi-model capability for regional climate change simulation is needed to perform original analyses to understand and prepare for the impacts of climate change on the time and space scales that are critical to California's future environmental quality and economic prosperity. Our intent was to develop a very high resolution regional simulation capability to address consequences of climate change in California to complement the global modeling capability that is supported by DOE at LLNL and other institutions to inform national and international energy policies. The California state government, through the California Energy Commission (CEC), institutionalized the State's climate change assessment process through its biennial climate change reports. The bases for these reports, however, are global climate change simulations for future scenarios designed to inform international policy negotiations, and are primarily focused on the global to continental scale impacts of increasing emissions of greenhouse gases. These simulations do not meet the needs of California public and private officials who will make major decisions in the next decade that require an understanding of climate change in California for the next thirty to fifty years and its effects on energy use, water utilization, air quality, agriculture and natural ecosystems. With the additional development of regional dynamical climate modeling capability, LLNL will be able to design and execute global simulations specifically for scenarios important to the state, then use those results to drive regional simulations of the impacts of the simulated climate change for regions as small as individual cities or watersheds. Through this project, we systematically studied the strengths and weaknesses of downscaling global model results with a regional mesoscale model to guide others, particularly university researchers, who are using the technique based on models with less complete parameterizations or coarser spatial resolution. Further, LLNL has now built a capability in state-of-the-science mesoscale climate modeling that complements that which it has in global climate simulation, providing potential sponsors with an end-to-end simulation and analysis program.

54 ENVIRONMENTAL SCIENCES↗

High-resolution imaging of NGC 2346 with GSAOI/GeMS: Disentangling the planetary nebula molecular structure to understand its origin and evolution

We present high spatial resolution (≈60–90 mas) images of the molecular hydrogen emission in the planetary nebula (PN) NGC 2346. The data were acquired during the system verification of the Gemini Multi-conjugate Adaptive Optics System + Gemini South Adaptive Optics Imager. At the distance of NGC 2346, 700 pc, the physical resolution corresponds to ≈56 AU, which is slightly higher than an [N ii] image of NGC 2346 that was obtained with the Hubble Space Telescope/WFPC2. With this unprecedented resolution, for the first time we were able to study the structure of the H{sub 2} gas within the nebula in detail. We found it to be composed of knots and filaments, which at a lower resolution had appeared to be a uniform torus of material. We explain how the formation of the clumps and filaments in this PN are consistent with a mechanism in which a central hot bubble of nebular gas surrounding the central star has been depressurized, and the thermal pressure of the photoionized region drives the fragmentation of the swept-up shell.

79 ASTRONOMY AND ASTROPHYSICS↗

APERTURE SYNTHESIS OBSERVATIONS OF CO, HCN, AND 89 GHz CONTINUUM EMISSION TOWARD NGC 604 IN M33: SEQUENTIAL STAR FORMATION INDUCED BY A SUPERGIANT H II REGION

We present the results from new Nobeyama Millimeter Array observations of CO(1-0), HCN(1-0), and 89 GHz continuum emission toward NGC 604, known as the supergiant H II region in the nearby galaxy M33. Our high spatial resolution images (4.''2 x 2.''6, corresponding to 17 pc x 11 pc physical size) of CO emission allowed us to uncover 10 individual molecular clouds that have masses of (0.8-7.4) x10{sup 5} M{sub sun} and sizes of 5-29 pc, comparable to those of typical Galactic giant molecular clouds. Moreover, we detected for the first time HCN emission in the two most massive clouds and 89 GHz continuum emission at the rims of the 'H{alpha} shells'. The HCN and 89 GHz continuum emission are offset from the CO peak and are distributed in the direction of the central cluster. Three out of ten CO clouds are well correlated with the H{alpha} shells both in spatial and velocity domains, implying an interaction between molecular gas and the expanding H II region. The CO clouds show varieties in star formation efficiencies (SFEs), which are estimated from the 89 GHz emission and combination of H{alpha} and Spitzer 24 {mu}m data. Furthermore, we found that the SFEs decrease with increasing projected distance measured from the heart of the central OB star cluster in NGC 604, suggesting radial changes in the evolutionary stages of the molecular clouds in the course of stellar cluster formation. Our results provide further support to the picture of sequential star formation in NGC 604 initially proposed by Tosaki et al. with the higher spatially resolved molecular clouds, in which an isotropic expansion of the H II region pushes gases outward, which accumulates to form dense molecular clouds, and then induces massive star formations.

79 ASTRONOMY AND ASTROPHYSICS↗

First results from the J-TEXT high-resolution three-wave polarimeter-interferometer

A laser-based far-infrared polarimeter-interferometer system utilizing the three-wave technique has been implemented on the J-TEXT tokamak. The polarimeter determines the Faraday effect by measuring the phase difference between two collinear, counter-rotating, circularly polarized laser beams. The first results of the polarimeter-interferometer designed for J-TEXT have been obtained in the most recent J-TEXT experimental campaign. Simultaneous polarimetric and interferometric measurement is achieved, with phase resolution up to 0.1 Degree-Sign , at bandwidth of 50 kHz. The temporal resolution, which is dependent on the laser's frequency offset, is {approx}1 {mu}s. Continual spatial measurement covering 45 cm (80% of the plasma cross-section) is realized by utilizing 1D parabolic beam expansion optics. Three initial test chords are installed and future plans call for expansion up to 30 chords with 1.5 cm chord spacing, providing high spatial resolution for measurement of electron density and current density profiles. Reliability of both polarimetric and interferometric measurement is confirmed by comparison with computation and data from a hydrocyanic acid (HCN) interferometer. With the high temporal and phase resolution, perturbations associated with the sawtooth cycle and MHD activity have been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Currents and Winds at the Delaware Bay Mouth

Knowledge of the circulation of estuaries and adjacent shelf waters has relied on hydrographic measurements, moorings, and local wind observations usually removed from the region of interest. Although these observations are certainly sufficient to identify major characteristics, they lack both spatial resolution and temporal coverage. High resolution synoptic observations are required to identify important coastal processes at smaller scales. Long observation periods are needed to properly sample low-frequency processes that may also be important. The introduction of high-frequency (HF) radar measurements and regional wind models for coastal studies is changing this situation. Here we analyze synoptic, high-resolution surface winds and currents in the Delaware Bay mouth over an eight-month period (October 2007 through May 2008). The surface currents were measured by two high-frequency radars while the surface winds were extracted from a data-assimilating regional wind model. To illustrate the utility of these monitoring tools we focus on two 45-day periods which previously were shown to present contrasting pictures of the circulation. One, the low-outflow period is from 1 October through 14 November 2007; the other is the high-outflow period from 3 March through 16 April 2008. The large-scale characteristics noted by previous workers are clearly corroborated. Specifically the M2 tide dominates the surface currents, and the Delaware Bay outflow plume is clearly evident in the low frequency currents. Several new aspects of the surface circulation were also identified. These include a map of the spatial variability of the M2 tide (validating an earlier model study), persistent low-frequency cross-mouth flow, and a rapid response of the surface currents to a changing wind field. However, strong wind episodes did not persist long enough to set up a sustained Ekman response.

54 ENVIRONMENTAL SCIENCES↗

AN INTRODUCTION TO THE CHANDRA CARINA COMPLEX PROJECT

The Great Nebula in Carina provides an exceptional view into the violent massive star formation and feedback that typifies giant H II regions and starburst galaxies. We have mapped the Carina star-forming complex in X-rays, using archival Chandra data and a mosaic of 20 new 60 ks pointings using the Chandra X-ray Observatory's Advanced CCD Imaging Spectrometer, as a testbed for understanding recent and ongoing star formation and to probe Carina's regions of bright diffuse X-ray emission. This study has yielded a catalog of properties of >14,000 X-ray point sources; >9800 of them have multiwavelength counterparts. Using Chandra's unsurpassed X-ray spatial resolution, we have separated these point sources from the extensive, spatially-complex diffuse emission that pervades the region; X-ray properties of this diffuse emission suggest that it traces feedback from Carina's massive stars. In this introductory paper, we motivate the survey design, describe the Chandra observations, and present some simple results, providing a foundation for the 15 papers that follow in this special issue and that present detailed catalogs, methods, and science results.

79 ASTRONOMY AND ASTROPHYSICS↗

Model of diffusion-assisted direct laser writing by means of nanopolymerization in the presence of radical quencher

Diffusion-assisted direct laser writing (DA-DLW) by multiphoton polymerization has been recently shown to be one of the most promising methods for the high-resolution 3D nanofabrication [I. Sakellari, et al., ACS Nano 6, 2302 (2012)]. The improvement of the writing spatial resolution has been observed under certain conditions when the mobile radical quencher (polymerization inhibitor) is added to the photosensitive composition. In this work, we present a theoretical study of this method, focusing on the resolution capabilities and optimal writing parameters. The laser beam absorption in the polymerizable composition causes the localized depletion of the quencher molecules. If the quencher depletion is balanced by its diffusion from the outside of the focal volume, the quasi-stationary non-equillibrium concentration spatial profile with zero minimum can be obtained. The polymer is then effectively formed only in the domain where the quencher is depleted. The spatially-distributed quencher, in this case, has the effect similar to that of the vortex beam in STimulated Emission Microscopy (STED)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploration of synchrotron Mossbauer micrscopy with micrometer resolution: forward and a new backscattering modality on natural samples

New aspects of synchrotron Moessbauer microscopy are presented. A 5 {micro}m spatial resolution is achieved, and sub-micrometer resolution is envisioned. Two distinct and unique methods, synchrotron Moessbauer imaging and nuclear resonant incoherent X-ray imaging, are used to resolve spatial distribution of species that are chemically and magnetically distinct from one another. Proof-of-principle experiments were performed on enriched {sup 57}Fe phantoms, and on samples with natural isotopic abundance, such as meteorites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗