Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of Two Different n-Butyl-2-Cyanoacrylates for the Embolization of Varicoceles: A Prospective, Randomized, Blinded Study

Purpose: This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles. Methods: A total of 112 insufficient spermatic veins (left-sided, n = 84; right-sided, n = 28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n = 54; Histoacryl, Braun, Germany) or NBCA-MS (n = 58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test. Results: Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n = 54/54, 100% vs. NBCA-MS, n = 54/57, 94.7%; P = 0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n = 45/54, 83.3% vs. NBCA-MS, n = 41/58, 70.7%; P = 0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n = 25/54, 46.3% vs. NBCA-MS, n = 29/58, 50%; P = 0.71). No glue-related complications were noted. Conclusions: NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

US-Guided Femoral and Sciatic Nerve Blocks for Analgesia During Endovenous Laser Ablation

Endovenous laser ablation may be associated with significant pain when performed under standard local tumescent anesthesia. The purpose of this study was to investigate the efficacy of femoral and sciatic nerve blocks for analgesia during endovenous ablation in patients with lower extremity venous insufficiency. During a 28-month period, ultrasound-guided femoral or sciatic nerve blocks were performed to provide analgesia during endovenous laser ablation in 506 legs and 307 patients. The femoral block (n = 402) was performed at the level of the inguinal ligament, and the sciatic block at the posterior midthigh (n = 124), by injecting a diluted lidocaine solution under ultrasound guidance. After the blocks, endovenous laser ablations and other treatments (phlebectomy or foam sclerotherapy) were performed in the standard fashion. After the procedures, a visual analogue pain scale (1-10) was used for pain assessment. After the blocks, pain scores were 0 or 1 (no pain) in 240 legs, 2 or 3 (uncomfortable) in 225 legs, and 4 or 5 (annoying) in 41 legs. Patients never experienced any pain higher than score 5. The statistical analysis revealed no significant difference between the pain scores of the right leg versus the left leg (p = 0.321) and between the pain scores after the femoral versus sciatic block (p = 0.7). Ultrasound-guided femoral and sciatic nerve blocks may provide considerable reduction of pain during endovenous laser and other treatments, such as ambulatory phlebectomy and foam sclerotherapy. They may make these procedures more comfortable for the patient and easier for the operator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 {+-} 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 {+-} -0.15 (right) and 0.61 {+-} -0.16 (left). After the procedure they were 0.86 {+-} -0.07 (right) and 0.90 {+-} -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Yttrium-90 Radioembolization for Unresectable Standard-chemorefractory Intrahepatic Cholangiocarcinoma: Survival, Efficacy, and Safety Study

To assess the overall survival, efficacy, and safety of radioembolization with yttrium-90 (Y90) for unresectable standard-chemorefractory intrahepatic cholangiocarcinoma (ICC). Patients with unresectable standard-chemorefractory ICC treated with Y90 were studied. Survival was calculated from the date of first Y90 procedure. Tumor response was assessed with the Response Evaluation Criteria in Solid Tumors criteria on follow-up computed tomography or magnetic resonance imaging scans. National Cancer Institute Common Terminology Criteria (NCI CTCAE), version 3, were used for complications. Statistical analysis was performed by the Kaplan-Meier estimator by the log rank test. Nineteen patients underwent a total of 24 resin-based Y90 treatments. Median survival from the time of diagnosis and first Y90 procedure was 752 {+-} 193 [95 % confidence interval (CI) 374-1130] and 345 {+-} 128 (95 % CI 95-595) days, respectively. Median survival with Eastern Cooperative Oncology Group (ECOG) performance status 1 (n = 15) and ECOG performance status 2 (n = 4) was 450 {+-} 190 (95 % CI 78-822) and 345 {+-} 227 (95 % CI 0-790) days, respectively (p = .214). Patients with extrahepatic metastasis (n = 11) had a median survival of 404 {+-} 309 (95 % CI 0-1010) days versus 345 {+-} 117 (95 % CI 115-575) days for patients without metastasis (n = 8) (p = .491). No mortality was reported within 30 days from first Y90 radioembolization. One patient developed grade 3 thrombocytopenia as assessed by NCI CTCAE. Fatigue and transient abdominal pain were observed in 4 (21 %) and 6 (32 %) patients, respectively. Y90 radioembolization is effective for unresectable standard-chemorefractory ICC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure in Biliary Procedures Performed to Manage Anastomotic Strictures in Pediatric Liver Transplant Recipients: Comparison Between Radiation Exposure Levels Using an Image Intensifier and a Flat-Panel Detector-Based System

Purpose: The aim of this study was to estimate radiation exposure in pediatric liver transplants recipients who underwent biliary interventional procedures and to compare radiation exposure levels between biliary interventional procedures performed using an image intensifier-based angiographic system (IIDS) and a flat panel detector-based interventional system (FPDS). Materials and Methods: We enrolled 34 consecutive pediatric liver transplant recipients with biliary strictures between January 2008 and March 2013 with a total of 170 image-guided procedures. The dose-area product (DAP) and fluoroscopy time was recorded for each procedure. The mean age was 61 months (range 4-192), and mean weight was 17 kg (range 4-41). The procedures were classified into three categories: percutaneous transhepatic cholangiography and biliary catheter placement (n = 40); cholangiography and balloon dilatation (n = 55); and cholangiography and biliary catheter change or removal (n = 75). Ninety-two procedures were performed using an IIDS. Seventy-eight procedures performed after July 2010 were performed using an FPDS. The difference in DAP between the two angiographic systems was compared using Wilcoxon rank-sum test and a multiple linear regression model. Results: Mean DAP in the three categories was significantly greater in the group of procedures performed using the IIDS compared with those performed using the FPDS. Statistical analysis showed a p value = 0.001 for the PTBD group, p = 0.0002 for the cholangiogram and balloon dilatation group, and p = 0.00001 for the group with cholangiogram and biliary catheter change or removal. Conclusion: In our selected cohort of patients, the use of an FPDS decreases radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tip embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mortality and Rates of Secondary Intervention After EVAR in an Unselected Population: Influence of Simple Clinical Categories and Implications for Surveillance

IntroductionPost-EVAR surveillance has a major impact upon patients, carers and healthcare resources. We hypothesised that elective indication, on-IFU anatomy, use of a modern device or normal first CTA, or a combination of these categories, might predict a rate of secondary intervention low enough to alter current surveillance protocols.MethodsPatients undergoing EVAR in our institution between 01.05.2007 and 28.02.2013 were assessed. Data on indication (elective, emergency), anatomy relative to IFU, device, first month CTA result, secondary intervention and mortality were obtained. Kaplan–Meier charts of mortality and freedom from secondary intervention were produced. Statistical analysis was by log-rank test and Cox proportional hazard modelling.Results234 patients underwent EVAR (188 elective, 208 on-IFU). Most implants were Endurant (106) or Talent (98). 151 patients had a normal first CTA. By median follow-up of 38.6 months, 39 patients underwent secondary intervention. A normal first CTA and elective indication were significantly associated with reduced risk of secondary intervention (p < 0.001 and p = 0.042 respectively), but device type and placement on- or off-IFU were not. Elective placement with a normal first CTA was 93 % predictive of freedom from secondary intervention by 32 months post-EVAR. Of nine patients undergoing secondary intervention in this group, eight presented symptomatically.DiscussionIn optimal procedural circumstances with normal post-procedural imaging, only 7 % of patients undergoing EVAR require secondary intervention, a minority of which is driven by surveillance. These data support a change to surveillance more tailored to the individual patient, and highlight the need for further qualitative and quantitative research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Direct Computed Tomography Venography in Predicting Inflow for Venous Reconstruction in Chronic Post-thrombotic Syndrome

Purpose: The purpose of this paper is to assess the applicability of direct computed tomography venography (DCTV) in assessing dominant inflow vein in the femoral confluence in extensive chronic iliofemoral venous obstruction, using venography as the gold standard. Methods: All DCTVs performed in symptomatic patients with previous iliofemoral deep vein thrombosis subsequently submitted to venography in the period from January 2014 to August 2018 were retrospectively reviewed. Two groups were defined depending on whether the femoral vein (FV) or the deep femoral vein (DFV) was the dominant inflow on venography in order to identify predictors of DFV as dominant inflow in DCTV. Statistical analysis was performed with SPSS V25. Results: A total of 30 DCTVs and subsequent venographies were reviewed. Venography identified the FV as the dominant inflow in 18 (60%) and the DFV in 12 (40%) patients. Predictors for DFV as dominant inflow were identified as follows: larger DFV diameter 50 mm and 250 mm below lesser trochanter (8.73 ± 4.34 mm vs. 11.9 ± 3.52 mm; p = 0.043 and 5.4 ± 3.90 mm vs. 8.90 ± 2.70 mm; p = 0.011); lower FV/DFV ratio 150 mm below lesser trochanter (11.39 ± 20.01 mm vs. 1.05 ± 0.47 mm; p = 0.043); and presence of FV scarring/synechiae, collaterals and abnormal wall thickness (p = 0.003, p = 0.003 and p < 0.0001). Conclusion: In cases of extensive chronic iliofemoral venous obstruction, especially when stent deployment into the DFV is entertained, the key to success is thorough pre-procedure planning focusing on choosing the access site. This study suggests DCTV is valuable in defining the dominant iliac vein inflow, but additional findings are necessary to validate these preliminary data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels

Purpose: To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. Materials and Methods: Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal–Wallis test and the Chi-squared test were used for statistical analysis. Results: For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm{sup 2}) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm{sup 2}, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm{sup 2}, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm{sup 2} vs. 4.00 ± 0.18 cm{sup 2}, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. Conclusion: Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Stochastic Study of Flow Anisotropy and Channelling in Open Rough Fractures

The quantification of fluid flow in rough fractures is of high interest for reservoir engineering, especially for deep geothermal applications. Herein, rough self-affine fractures are stochastically generated with incremental shear displacement and geometrically described by two aperture definitions, the vertical aperture a vert and the effective aperture a eff . In order to compare their effect on fracture flow, such as anisotropy and channelling, Local Cubic Law (LCL) model-based 2D fluid flow is simulated. The particularity of this approach is the combination of a stochastic generation of self-affine fractures with a statistical analysis (560 individual realizations) of the impact of the LCL’s aperture constraint on fracture flow. The results show that aperture definition affects the quantitative interpretation of flow anisotropy and channeling as well as the aperture distribution of the fractures with shearing. Higher values of mean aperture for a given fracture are found using a vert , whereas the aperture standard deviation is larger with a eff . In addition, flow anisotropy is significantly sensitive to aperture definition for small shear displacements and shows a relative higher dispersion with a eff . Thus, LCL prediction models based on a vert are expected to lead to higher dispersion of anisotropy results with a higher uncertainty (factor ~ 2). Realizations based on avert lead to an enhanced clustering of high flow rates for higher shearing displacements. This channeling development results in higher total flow rates for these simulations. Finally, these findings support the direct calibration of pre-existing LCL anisotropy simulations based on avert towards more representative results using a eff .

58 GEOSCIENCES↗

Geometry, spin coupling, and dielectric control of redox potentials in [4Fe–4S] Clusters

Iron–sulfur (Fe–S) clusters are common biological cofactors that facilitate vital redox reactions. Despite extensive research, the molecular basis of redox potential tuning in ferredoxin-like proteins remains an active area of debate. In this study, we combine statistical analysis of over one thousand [4Fe–4S]-containing protein structures from the Protein Data Bank (PDB) with broken-symmetry and extended broken-symmetry density functional theory to examine how cysteine ligand orientations and environmental screening affect redox properties of the clusters. We identified five main ligand configurations, three of which are predominant in natural structures. Among these, the adiabatic electron affinity differs by less than 0.1 V, indicating that, while geometry plays a secondary role, it allows localized fine-tuning of redox properties. In contrast, electrostatic and solvation effects primarily determine the overall potential range.

Computational Chemistry↗

Operational Efficiency Evaluation of a Setup for Removing Stresses in the Steam Header of PGV-1000 Steam Generator

The effectiveness of a setup for removing stresses in the steam header of a PGV-1000 steam generator is evaluated. The evaluation is based on an investigation of the stress state by means of magnetic anisotropy measurements performed in the zone of the No. 111 weld seam of the hot header of steam generators operating in one of the power-generating units with a V-320 series reactor arrangement. Inspections made it possible to obtain cartograms of the distribution of the difference of the principal mechanical stresses along the perimeter of the weld connection of a PGV-1000 header equipped with a cooling mantle and headers without such a mantle. By means of statistical analysis of the data, a diagram of the distribution of the principal mechanical stresses was obtained. In addition, the distribution of the standard deviation of the principal mechanical stresses as a measure of the dispersion of a random quantity relative to its mathematical expectation was determined.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗