Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

An X-ray flare from 47 Cas

Using XMM-Newton observations, we investigate properties of a flare from the very active but poorly known stellar system 47 Cas. The luminosity at the peak of the flare is found to be 3.54 × 10{sup 30} erg s{sup −1}, which is ∼2 times higher than that at a quiescent state. The quiescent state corona of 47 Cas can be represented by two temperature plasma: 3.7 and 11.0 MK. The time-resolved X-ray spectroscopy of the flare show the variable nature of the temperature, the emission measure, and the abundance. The maximum temperature during the flare is derived as 72.8 MK. We infer the length of a flaring loop to be 3.3 × 10{sup 10} cm using a hydrodynamic loop model. Using the RGS spectra, the density during the flare is estimated as 4.0 × 10{sup 10} cm{sup −3}. The loop scaling laws are also applied when deriving physical parameters of the flaring plasma.

79 ASTRONOMY AND ASTROPHYSICS↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Internal Variability Increased Arctic Amplification During 1980–2022

Abstract Since 1980, the Arctic surface has warmed four times faster than the global mean. Enhanced Arctic warming relative to the global average warming is referred to as Arctic Amplification (AA). While AA is a robust feature in climate change simulations, models rarely reproduce the observed magnitude of AA, leading to concerns that models may not accurately capture the response of the Arctic to greenhouse gas emissions. Here, we use CMIP6 data to train a machine learning algorithm to quantify the influence of internal variability in surface air temperature trends over both the Arctic and global domains. Application of this machine learning algorithm to observations reveals that internal variability increases the Arctic warming but slows global warming in recent decades, inflating AA since 1980 by 38% relative to the externally forced AA. Accounting for the role of internal variability reconciles the discrepancy between simulated and observed AA.

58 GEOSCIENCES↗

Scale Resistant Heat Exchanger for Low Temperature Geothermal Binary Cycle Power Plant

Phase 1 of the investigation of improvements to low temperature geothermal power systems was completed. The improvements considered were reduction of scaling in heat exchangers and a hermetic turbine generator (eliminating seals, seal system, gearbox, and lube oil system). A scaling test system with several experiments was designed and operated at Coso geothermal resource with brine having a high scaling potential. Several methods were investigated at the brine temperature of 235 ºF. One method, circulation of abradable balls through the brine passages, was found to substantially reduce scale deposits. The test heat exchanger was operated with brine outlet temperatures as low as 125 ºF, which enables increased heat input available to power conversion systems. For advanced low temperature cycles, such as the Variable Phase Cycle (VPC) or Kalina Cycle, the lower brine temperature will result in a 20-30% increase in power production from low temperature resources. A preliminary design of an abradable ball system (ABS) was done for the heat exchanger of the 1 megawatt VPC system at Coso resource. The ABS will be installed and demonstrated in Phase 2 of this project, increasing the power production above that possible with the present 175 ºF brine outlet limit. A hermetic turbine generator (TGH) was designed and manufacturing drawings produced. This unit will use the working fluid (R134a) to lubricate the bearings and cool the generator. The 200 kW turbine directly drives the generator, eliminating a gearbox and lube oil system. Elimination of external seals eliminates the potential of leakage of the refrigerant or hydrocarbon working fluids, resulting in environmental improvement. A similar design has been demonstrated by Energent in an ORC waste heat recovery system. The existing VPC power plant at Coso was modified to enable the “piggyback” demonstration of the TGH. The existing heat exchanger, pumps, and condenser will be operated to provide the required process conditions for the TGH demonstration. Operation of the TGH with and without the ABS system will demonstrate an increase in geothermal resource productivity for the VPC from 1 MW/(million lb) of brine to 1.75 MW/(million lb) of brine, a 75% increase.

15 GEOTHERMAL ENERGY↗

Time-division multiplexer uses digital gates

Device eliminates errors caused by analog gates in multiplexing a large number of channels at high frequency. System was designed for use in aerospace work to multiplex signals for monitoring such variables as fuel consumption, pressure, temperature, strain, and stress. Circuit may be useful in monitoring variables in process control and medicine as well.

Myers, C. E.↗

A comprehensive model to determine the effects of temperature and species fluctuations on reaction rates in turbulent reacting flows

The use of probability theory to determine the effects of turbulent fluctuations on reaction rates in turbulent combustion systems is briefly reviewed. Results are presented for the effect of species fluctuations in particular. It is found that turbulent fluctuations of species act to reduce the reaction rates, in contrast with the temperature fluctuations previously determined to increase Arrhenius reaction rate constants. For the temperature fluctuations, a criterion is set forth for determining if, in a given region of a turbulent flow field, the temperature can be expected to exhibit ramp like fluctuations. Using the above results, along with results previously obtained, a model is described for testing the effects of turbulent fluctuations of temperature and species on reaction rates in computer programs dealing with turbulent reacting flows. An alternative model which employs three variable probability density functions (temperature and two species) and is currently being formulated is discussed as well.

Chinitz, W.↗

Decadal Covariability of the Northern Wintertime Land Surface Temperature and Atmospheric Circulation

The decadal covariability of northern wintertime land surface temperature and 500-hPa geopotential anomalies is examined using the National Centers for Environmental Prediction–National Center for Atmospheric Research and the Twentieth-Century Reanalyses over the twentieth century and a 996-yr preindustrial climate simulation from the Canadian Earth System Model. Based on the reanalysis data, the covariability is dominated by two leading maximum covariance analysis (MCA) modes. MCA1 is characterized by temperature anomalies over most of Canada, the eastern United States, Mexico, and Eurasian mid- to high latitudes, accompanied by anomalies of opposite sign elsewhere over northern landmasses. MCA2 features temperature anomalies over most of North America, Eurasia, and Greenland with opposite anomalies elsewhere. In the upper troposphere the synoptic vorticity fluxes reinforce the anomalous circulation, while in the lower troposphere advection by the anomalous mean flow offsets the eddy forcing and maintains the decadal temperature perturbation. The MCA1-associated variability has a broad spectrum over decadal–interdecadal time scales, while the MCA2-related variability has a significant power peak around 20 yr. The change of temperature and geopotential trends around 1990 tends to be a decadal-scale shift in winter and has significant features of the leading mode of the decadal covariability. The climate model has broadly similar decadal covariability, including the leading MCA patterns as well as the temporal evolution of the patterns. The decadal temperature and geopotential anomalies primarily covary with the North Atlantic Oscillation but also with the variability of the North Pacific index, while the Southern Oscillation index variability tends to be the least important predictor for the northern decadal temperature and geopotential anomalies.

54 ENVIRONMENTAL SCIENCES↗

Individual variation in circadian rhythms of sleep, EEG, temperature, and activity among monkeys - Implications for regulatory mechanisms.

Investigation of circadian rhythms in a number of variables related to sleep, EEG, temperature, and motor activity in rhesus monkeys on an LD 12:12 schedule. Circadian rhythms were found to appear in each of 15 variables investigated. Statistical procedures assessed the variables for evidence of common regulation in these aspects of their circadian rhythms: acrophase (timing), amplitude (extent of change), and level (24-hr mean value). Patterns appearing in the data suggested that the circadian rhythms of certain variables are regulated in common. The circadian modulation of activity in the beta and sigma frequency bands of the EEG was correlated with statistical significance in acrophase, level, and amplitude. The delta frequency band appeared to be under circadian rhythm regulation distinct from that of the other bands. The circadian rhythm of REM stage sleep was like that of beta activity in level and amplitude. The data indicate that REM stage may share some common regulation of circadian timing with both stage 3-4 sleep and with temperature. Generally, however, the circadian rhythm of temperature appeared to bear little relation to the circadian rhythms of motor activity, EEG, or sleep.

Crowley, T. J.↗

Progress Toward Simulating Departure from Nucleate Boiling at High-Pressure Applications with Selected Wall Boiling Closures

Recently, a Eulerian-based two-fluid computational fluid dynamics (CFD) framework with a wall heat flux partitioning approach has been intensively investigated for departure from nucleate boiling (DNB) simulation under the U.S. Department of Energy–funded Consortium for Advanced Simulation of Light Water Reactors (CASL) program. Understanding of the DNB characteristics over a range of pressurized water reactor–like operating conditions and accurate prediction of boiling crisis in the nuclear power system have been grand challenges because of the large impact of DNB on reactor safety and operational economics. The ultimate goal of this task in the CASL program is to introduce a robust multiphase CFD–based DNB modeling framework that is capable of characterizing an entire boiling history in which the wall boiling mode experiences the following through multiple stages of heat transfer mode: (1) single-phase convective heat transfer, (2) nucleate boiling heat transfer, and (3) identification of the departure of nucleate boiling. To validate the CASL boiling model, we have benchmarked simulated DNB over three different flow channel configurations (pipe flow, 5 × 5 fuel bundle with mixing vane tests, and 5 × 5 fuel bundle without mixing vane tests) against experimental measurements, and the validation result with open literature is reported. The DNB detection criteria in the simulation are checked by monitoring the peak wall temperature, wall dryout factor, and net energy balance. In addition to the DNB performance test, some preliminary sensitivity results on closure model selection are reported to address the prediction capability of local void profile against measurements. The boiling simulation tested in this study exhibits a maximum deviation of 24% from the measured DNB value in a high-pressure (i.e., 138 bars) subcooled pipe flow test. The ranges of operating conditions are as follows: 1650 to 2650 kg/m 2 ·s for mass flux and 8.5 to 96 K for subcooled inlet temperature. The deviation is even reduced to 7% when the subcooled temperature is less than 40 K. Besides accuracy, base practice guidelines for DNB detection criteria are tested by monitoring three simulation variables: (1) maximum wall temperature, (2) wall dryout factor (i.e., K-value), and (3) energy balance. Numerical robustness of DNB simulation is largely achieved in most of the validation test except for a few high subcooled test cases.

42 ENGINEERING↗

Saturn's upper atmosphere from the Voyager 2 EUV solar and stellar occultations

The temperature and composition of the upper atmosphere of Saturn have been inferred from Voyager 2 ultraviolet-spectrometer-occultation measurements made by observing the sun and the star Delta Scorpii while they were being occulted by Saturn. The observations analyzed here provide atmospheric parameters from 2900 km down to 960 km above the 1-bar level referred to the equator. The temperature in the model simulation of the data is 420 + or - 30 K down to about 1600 km. Below 1600 km the temperature decreases with a variable lapse rate down to 120 + or - 30 K near the methane homopause located at 1010 + or - 40 km. A constant temperature at 120 K is applied in the model for the region of the methane homopause down to 960 km where the present analysis terminates. Column amounts of H2 and H were measured from 2900 km down to about 1100 km, giving respective densities of about 1.0 x 10 to the 8th/cu cm and about 5.5 x 10 to the 6th/cu cm near the exobase at 2500 km. Near the methane homopause the H2 density is = 1.2 x 10 to the 12th/cu cm with a CH4 number-density mixing ratio of 0.00006. The eddy-diffusion coefficient in the vicinity of the methane homopause is estimated to be 5.0 x 10 to the 6th sq cm/sec. The atomic hydrogen density profile suggests a downward H flux of 1.8 x 10 to the 9th sq cm/sec from near the exobase down to a terminal boundary of about 1200 km.

Smith, G. R.↗

Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitivity, and careful quality control in any study of composite materials.

Clements, L. L.↗

Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitvity, and careful quality control in any study of composite materials. Previously announced in STAR as N80-33493

Clements, L. L.↗

Low temperature charge transport and microwave absorption of carbon coated iron nanoparticles–polymer composite films

Highlights: ► Carbon coated Fe nanoparticle–PVC composite films were prepared by solution casting method. ► A low electrical percolation threshold of 2.2 was achieved. ► The low temperature electrical conductivity follows variable range hopping type conduction. ► An EMI shielding of 18 dB was achieved in 200 micron thick film. -- Abstract: In this paper, the low temperature electrical conductivity and microwave absorption properties of carbon coated iron nanoparticles–polyvinyl chloride composite films are investigated for different filler fractions. The filler particles are prepared by the pyrolysis of ferrocene at 980 °C and embedded in polyvinyl chloride matrix. The high resolution transmission electron micrographs of the filler material have shown a 5 nm thin layer graphitic carbon covering over iron particles. The room temperature electrical conductivity of the composite film changes by 10 orders of magnitude with the increase of filler concentration. A percolation threshold of 2.2 and an electromagnetic interference shielding efficiency (EMI SE) of ∼18.6 dB in 26.5–40 GHz range are observed for 50 wt% loading. The charge transport follows three dimensional variable range hopping conduction.

36 MATERIALS SCIENCE↗

The effect of forging history on the strength and microstructure of TDNiCr /Ni-20Cr-2ThO2/

Forging variables were evaluated to determine their influence on the elevated temperature strength and microstructure of TDNiCr. Grain size was the principal microstructural feature related to elevated temperature strength and was controlled primarily by the thermomechanical variables of forging temperature and final annealing condition. Tests at 1366 K revealed a factor of eight increase in tensile strength as grain size increased from 1 to 150 microns, while stress-rupture strength improved by three to five times as grain size increased from 15 to 150 microns. Forged material of grain size greater than or equal to about 150 microns displayed a level of elevated temperature strength comparable to that of optimized TDNiCr sheet. The presence of a preponderance of small twins and a strong preferred orientation may have also been factors contributing to the excellent high temperature strength of large grain forged material.

Filippi, A. M.↗

Influence of Combustion Conditions on Yields of Solvent-Extractable Anhydrosugars and Lignin Phenols in Chars: Implications for Characterizations of Biomass Combustion Residues

Anhydrosugars, such as levoglucosan and its isomers (mannosan, galactosan), as well as the solvent-extractable lignin phenols (methoxylated phenols) are thermal degradation products of cellulose/hemicellulos and lignin, respectively. These two groups of biomarkers are often used as unique tracers of combusted biomass inputs in diverse environmental media. However, detail characterization of the relative proportion and signatures of these compounds in highly heterogeneous plant-derived chars/charcoals are still scarce. Here we conducted a systematic study to investigate the yields of solvent-extractable anhydrosugars and lignin phenols in twenty-five lab-made chars produced from different plant materials under different combustion conditions. Solvent extractable anhydrosugars and lignin phenols were only observed in chars formed below 350 C and yields were variable across different combustion temperatures. The yields mannosan (M) and galactosan (G) decreased more rapidly than those of levoglucosan (L) under increasing combustion severity (temp. and duration), resulting in variable L/M and L/(M+G) ratios, two diagnostic ratios often used for identification of combustion sources (e.g. hardwoods vs. softwoods vs. grasses). On the other hand, the results of this study suggest that the ratios of the major solvent-extractable lignin phenols (vanillyls (V), syringyls (S), cinnamyls (C)) provide additional source reconstruction potential despite observed variations with combustion temperature. We thus propose using a property property plot (L/M vs. S/V) as an improved means for source characterization of biomass combustion residues. The L/M-S/V plot has shown to be effective in environmental samples (soil organic matter, atmospheric aerosols) receiving substantial inputs of biomass combustion residues.

09 BIOMASS FUELS↗

Hysteretic temperature sensitivity of wetland CH 4 fluxes explained by substrate availability and microbial activity

Methane (CH 4 ) emissions from wetlands are likely increasing and important in global climate change assessments. However, contemporary terrestrial biogeochemical model predictions of CH 4 emissions are very uncertain, at least in part due to prescribed temperature sensitivity of CH 4 production and emission. While statistically consistent apparent CH 4 emission temperature dependencies have been inferred from meta-analyses across microbial to ecosystem scales, year-round ecosystem-scale observations have contradicted that finding. Here, we show that apparent CH 4 emission temperature dependencies inferred from year-round chamber measurements exhibit substantial intra-seasonal variability, suggesting that using static temperature relations to predict CH 4 emissions is mechanistically flawed. Our model results indicate that such intra-seasonal variability is driven by substrate-mediated microbial and abiotic interactions: seasonal cycles in substrate availability favors CH 4 production later in the season, leading to hysteretic temperature sensitivity of CH 4 production and emission. Our findings demonstrate the uncertainty of inferring CH 4 emission or production rates from temperature alone and highlight the need to represent microbial and abiotic interactions in wetland biogeochemical models.

54 ENVIRONMENTAL SCIENCES↗