Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Ellipsometric study of Si(0.5)Ge(0.5)/Si strained-layer superlattices

An ellipsometric study of two Si(0.5)Ge(0.5)/Si strained-layer super lattices grown by MBE at low temperature (500 C) is presented, and results are compared with x ray diffraction (XRD) estimates. Excellent agreement is obtained between target values, XRD, and ellipsometry when one of two available Si(x)Ge(1-x) databases is used. It is shown that ellipsometry can be used to nondestructively determine the number of superlattice periods, layer thicknesses, Si(x)Ge(1-x) composition, and oxide thickness without resorting to additional sources of information. It was also noted that we do not observe any strain effect on the E(sub 1) critical point.

Sieg, R. M.↗

Elemental Abundances of nearby M Dwarfs Based on High-resolution Near-infrared Spectra Obtained by the Subaru/IRD Survey: Proof of Concept

Detailed chemical analyses of M dwarfs are scarce but necessary to constrain the formation environment and internal structure of planets being found around them. We present elemental abundances of 13 M dwarfs (2900 < T eff < 3500 K) observed in the Subaru/IRD planet search project. They are mid- to late-M dwarfs whose abundance of individual elements has not been well studied. We use the high-resolution (∼70,000) near-infrared (970–1750 nm) spectra to measure the abundances of Na, Mg, Si, K, Ca, Ti, V, Cr, Mn, Fe, and Sr by the line-by-line analysis based on model atmospheres, with typical errors ranging from 0.2 dex for [Fe/H] to 0.3–0.4 dex for other [X/H]. We measure radial velocities from the spectra and combine them with Gaia astrometry to calculate the Galactocentric space velocities UVW . The resulting [Fe/H] values agree with previous estimates based on medium-resolution K-band spectroscopy, showing a wide distribution of metallicity (−0.6 < [Fe/H] < +0.4). The abundance ratios of individual elements [X/Fe] are generally aligned with the solar values in all targets. While the [X/Fe] distributions are comparable to those of nearby FGK stars, most of which belong to the thin-disk population, the most metal-poor object, GJ 699, could be a thick-disk star. The UVW velocities also support this. The results raise the prospect that near-infrared spectra of M dwarfs obtained in the planet search projects can be used to grasp the trend of elemental abundances and the Galactic stellar population of nearby M dwarfs.

Hiroyuki Tako Ishikawa↗

Atomic scale investigations of ferroelectricity in perovskite thin

Superlattices of suitable perovskite oxides can be used to create novel materials for device applications. Calculations have shown that superlattices with atomically flat, compositionally abrupt interfaces will result in enhanced ferroelectric properties due to strain, changes in bonding and charge compensation at the interfaces. But can these abrupt interfaces be actually grown and monitored at an atomic level? We have shown that it is possible to produce structures hundreds of layers thick using two and three perovskite building blocks.[1-2] Our CaTiO3/SrTiO3/BaTiO3 superlattices exhibited a 50% enhancement in ferroelectric polarization compared with BaTiO3. These films were grown using pulsed laser deposition (PLD) using stoichiometric perovskite targets. The deposition of each unit cell of the films was monitored using the intensity oscillations of the reflection high-energy electron diffraction specular spot.

36 MATERIALS SCIENCE↗

Injectable and implantable cellular-scale electronic devices

Provided are implantable or surface mounted biomedical devices and related methods for interfacing with a target tissue. The devices have a substrate and device component supported by the substrate. The components of the device are specially configured and packaged to be ultra-thin and mechanically compliant. In particular, device thicknesses are less than 1 mm and have lateral dimensions between about 1 m and 10 mm, depending on the application. Delivery substrates may be incorporated to assist with device implantation and handling. The devices can be shaped to provide injection in a minimally invasive manner, thereby avoiding unnecessary tissue damage and providing a platform for long-term implantation for interfacing with biological tissue.

36 MATERIALS SCIENCE↗

MC{sup 2}-3/DIF3D Analysis of the ZPPR-15B Foil Measurements

The Zero Power Physics Reactor (ZPPR) fast critical facility at the Argonne National Laboratory-West site in Idaho was built in 1969 to obtain neutron physics information necessary for the design of fast breeder reactors. The ZPPR-15 phases A through D were intended to model a 330 MWt Integral Fast Reactor (IFR) concept. This work focuses on foil measurements in the shielding regions of ZPPR-15B. The ZPPR-15B core simulated an equilibrium cycle U-Pu-Zr fuel core where plutonium created in the blankets was sufficient to negate the need for enriched {sup 235}U feedstock. ZPPR-15B consisted of an inner core zone, an outer core zone of higher fissile content, a thin radial blanket and a thick steel reflector. The inner and outer core zones were of approximately equal volumes and were designed to simulate a sodium-cooled, metal-fueled fast reactor with approximately 10 wt.% zirconium in the target fuel composition. Consistent with the IFR program, ZPPR-15B had Zr plates in the inner core region to simulate a Zr alloyed fuel composition. The outer core had no Zr plates due to the limited inventory of Zr plates and thus consisted of drawers which had stainless steel plates rather than Zr. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced Optical Head Tracking for Cranial Radiation Therapy: Supporting Surface Registration by Cutaneous Structures

Purpose: To support surface registration in cranial radiation therapy by structural information. The risk for spatial ambiguities is minimized by using tissue thickness variations predicted from backscattered near-infrared (NIR) light from the forehead. Methods and Materials: In a pilot study we recorded NIR surface scans by laser triangulation from 30 volunteers of different skin type. A ground truth for the soft-tissue thickness was segmented from MR scans. After initially matching the NIR scans to the MR reference, Gaussian processes were trained to predict tissue thicknesses from NIR backscatter. Moreover, motion starting from this initial registration was simulated by 5000 random transformations of the NIR scan away from the MR reference. Re-registration to the MR scan was compared with and without tissue thickness support. Results: By adding prior knowledge to the backscatter features, such as incident angle and neighborhood information in the scanning grid, we showed that tissue thickness can be predicted with mean errors of <0.2 mm, irrespective of the skin type. With this additional information, the average registration error improved from 3.4 mm to 0.48 mm by a factor of 7. Misalignments of more than 1 mm were almost thoroughly (98.9%) pushed below 1 mm. Conclusions: For almost all cases tissue-enhanced matching achieved better results than purely spatial registration. Ambiguities can be minimized if the cutaneous structures do not agree. This valuable support for surface registration increases tracking robustness and avoids misalignment of tumor targets far from the registration site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parallaxes of southern extremely cool objects (parsec). II. Spectroscopic follow-up and parallaxes of 52 targets

We present near-infrared spectroscopy for 52 ultracool dwarfs, including two newly discovered late-M dwarfs, one new late-M subdwarf candidate, three new L, and four new T dwarfs. We also present parallaxes and proper motions for 21 of them. Four of the targets presented here have previous parallax measurements, while all the others are new values. This allow us to populate further the spectral sequence at early types (L0-L4). Combining the astrometric parameters with the new near-infrared spectroscopy presented here, we are able to investigate further the nature of some of the objects. In particular, we find that the peculiar blue L1 dwarf SDSS J133148.92–011651.4 is a metal-poor object, likely a member of the galactic thick disk. We discover a new M subdwarf candidate, 2MASS J20115649–6201127. We confirm the low-gravity nature of EROS-MP J0032–4405, DENIS-P J035726.9–441730, and 2MASS J22134491–2136079. We present two new metal-poor dwarfs: the L4pec 2MASS J19285196–4356256 and the M7pec SIPS2346–5928. We also determine the effective temperature and bolometric luminosity of the 21 targets with astrometric measurements, and we obtain a new polynomial relation between effective temperature and near-infrared spectral type. The new fit suggests a flattening of the sequence at the transition between M and L spectral types. This could be an effect of dust formation, which causes a more rapid evolution of the spectral features as a function of the effective temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Sputter deposition of high electrical resistivity Au-Ta alloy coatings on rotating substrates

Sputter deposition of gold-tantalum alloy coatings is a key process for manufacturing hohlraums for magnetically-assisted inertial confinement fusion implosions. In this report we describe direct current magnetron sputter deposition of ~ 10 - μ~ 10 - μm-thick films of Au-80 at.% Ta onto rotating sphero-cylindrical hohlraum and planar Si witness substrates. Emphasis is given to how film microstructure and properties are affected by main deposition parameters, including argon working gas pressure, substrate bias, and the source composition (a single alloyed target compared to co-sputtering from two elemental targets). Experimental findings are correlated with distributions of landing energies and incident angles of depositing species calculated by Monte Carlo simulations of ballistic collisions and gas phase atomic transport. Deposition conditions characterized by low energetics of depositing species favor the formation of a β-Ta-like phase. Implications of these results to hohlraum fabrication are discussed.

36 MATERIALS SCIENCE↗

WE-EF-BRA-06: Feasibility of Spatially Modulated Proton Beams for Small Animal Research

Purpose: To investigate the feasibility of proton minibeam radiotherapy (pMBRT) for small animal research. The motivation is to explore with protons the extraordinary normal tissue sparing effects to spatially modulated beams as observed on high flux synchrotron beam lines. We hypothesized that we can design a multi-slit collimator for our proton beam line to produce planar-parallel dose profiles with high modulation in the entrance region and homogenous dose coverage in the overlap of the Bragg peaks. Methods: The high dose rate 50 MeV research proton beamline at the University of Washington was modeled using the TOol for PArticle Simulation (TOPAS) Monte Carlo package. A brass collimator was implemented to generate proton minibeams. The collimator consists of an array of 2 cm long slits to cover an area of 2×2 cm{sup 2}. The slit widths (0.1–1 mm), center-to-center (ctc) distances (1–3 mm) and collimator thickness (1–7 cm) were varied to evaluate the effect on dose rate, the peak-to-valley dose ratios (PVDR) and the change of penumbra and peak width (FWHM) with depth. Results: The Bragg peak was at a depth of ∼21 mm. The penumbra and FWHM remained relatively constant to a depth of about 10–15 mm. The PVDR ranged from 1.6 to 26 and the dose rate dropped exponentially with collimator thickness. A uniform dose can be achieved at depth with slightly compromised PVDRs and dose rate. Conclusion: The technical realization of pMBRT is feasible. The simulations have shown that it is possible to obtain uniform dose at depth while modulation is maintained on the entrance side. While the simulated beam widths are larger than on synchrotron generated microbeams the dosimetric advantage could avoid having to interlace two microbeams to achieve uniform dose in the target. The next steps are to build a collimator and verify the simulations experimentally.

60 APPLIED LIFE SCIENCES↗

High Specific Activity Sm-153 By Post Irradiation Isotope Separation (Final Scientific Technical Report)

The isotope, samarium-153 ( 153 Sm) has ideal nuclear properties well suited for a variety of therapeutic applications; however, it is only available with low specific activity (radioactivity per unit mass) due to the method of production. Commercially useful quantities can be made by the 152 Sm (n,γ) 153 Sm reaction in a nuclear reactor, but typical irradiation parameters result in less than 2% of the 152 Sm target material being converted, leading to a very diluted end product. Since chemical processing methods cannot be used to perform isotopic separation, this means that >98% of the resultant pharmaceutical molecules are labeled with “cold” target atoms and are incapable of providing any radiation-induced therapeutic effect. The goals of this project were to introduce a new approach to the production of high specific activity (HSA) 153 Sm utilizing electromagnetic isotope separation (EMIS), and to perform biodistribution and chemistry studies with such HSA 153 Sm to test labeling capability with targeting molecules. Included in these studies was the successful development of a collection substrate that would allow the efficient deposit and removal of 153 Sm; to this end, DLC (diamond like carbon) foils were successfully employed. In the first year of this project a surface ion source was developed, leading to the successful production of a mass separated beam of stable Sm ions. Studies were then performed using similar apparatus at the Oak Ridge National Laboratory, leading to a well-separated beam of isotopically pure samarium ions. This was followed by the successful production of four 15 mCi samples (over a 7 month period) of HSA 153 Sm which were delivered to the IsoTherapeutics Group for biodistribution and chemical labeling studies. Such samples were produced by neutron irradiation of 5 mg metal samples of 152 Sm at the HFIR (ORNL High Flux Isotope Reactor), followed by manual transfer of the samples from the irradiation capsule to the chamber of a surface ion source. Isotopic beams were then extracted using the IRIS2 EMIS facility, and collected onto 10 μm thick DLC foils. The samples were irradiated for 10 h periods, with typical collection periods lasting 12 - 16 h. Employing appropriate chemical approaches, these HSA 153 Sm samples were evaluated for labeling with small, medium and large molecules. The ability to label a variety of targeting molecules is important to demonstrate the potential therapeutic capabilities. Biodistribution studies, using HSA 153 Sm with the bone agent DOTMP, in rodents demonstrated that the biodistribution is similar to what is observed with LSA 153 Sm. Labeling was successfully achieved with peptides, and large protein molecules.

07 ISOTOPE AND RADIATION SOURCES↗

Temporally and spatially resolved plasma spectroscopy in pulsed laser deposition of ultra-thin boron nitride films

Physical vapor deposition (PVD) has recently been investigated as a viable, alternative growth technique for two-dimensional materials with multiple benefits over other vapor deposition synthesis methods. The high kinetic energies and chemical reactivities of the condensing species formed from PVD processes can facilitate growth over large areas and at reduced substrate temperatures. In this study, chemistry, kinetic energies, time of flight data, and spatial distributions within a PVD plasma plume ablated from a boron nitride (BN) target by a KrF laser at different pressures of nitrogen gas were investigated. Time resolved spectroscopy and wavelength specific imaging were used to identify and track atomic neutral and ionized species including B{sup +}, B*, N{sup +}, N*, and molecular species including N{sub 2}*, N{sub 2}{sup +}, and BN. Formation and decay of these species formed both from ablation of the target and from interactions with the background gas were investigated and provided insights into fundamental growth mechanisms of continuous, amorphous boron nitride thin films. The correlation of the plasma diagnostic results with film chemical composition and thickness uniformity studies helped to identify that a predominant mechanism for BN film formation is condensation surface recombination of boron ions and neutral atomic nitrogen species. These species arrive nearly simultaneously to the substrate location, and BN formation occurs microseconds before arrival of majority of N{sup +} ions generated by plume collisions with background molecular nitrogen. The energetic nature and extended dwelling time of incident N{sup +} ions at the substrate location was found to negatively impact resulting BN film stoichiometry and thickness. Growth of stoichiometric films was optimized at enriched concentrations of ionized boron and neutral atomic nitrogen in plasma near the condensation surface, providing few nanometer thick films with 1:1 BN stoichiometry and good thicknesses uniformity over macroscopic areas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Currents and fields reveal the propagation of nuclear polaritons through a resonant target

Nuclear resonant scattering of synchrotron radiation was investigated simultaneously in the spatially incoherent (4{pi}) and in the spatially coherent (forward) scattering channels. A theory is presented which describes the main contributions to the scattering picture. To observe the 4{pi} scattering, a nuclear target (spectator) was employed which was mounted downstream of another target (emitter). Emitter and spectator formed a combined scattering system. The time evolutions of the 4{pi} scattering from the spectator and of the forward scattering from the combined system were measured and compared for different thicknesses of emitter and spectator. These observations and the analysis of the obtained time evolutions reveal how nuclear polaritons propagate through a scattering system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasimonoenergetic Proton Bunch Generation by Dual-Peaked Electrostatic-Field Acceleration in Foils Irradiated by an Intense Linearly Polarized Laser

It is found that stable proton acceleration from a thin foil irradiated by a linearly polarized ultraintense laser can be realized for appropriate foil thickness and laser intensity. A dual-peaked electrostatic field, originating from the oscillating and nonoscillating components of the laser ponderomotive force, is formed around the foil surfaces. This field combines radiation-pressure acceleration and target normal sheath acceleration to produce a single quasimonoenergetic ion bunch. A criterion for this mechanism to be operative is obtained and verified by two-dimensional particle-in-cell simulation. At a laser intensity of {approx}5.5x10{sup 22} W/cm{sup 2}, quasimonoenergetic GeV proton bunches are obtained with {approx}100 MeV energy spread, less than 4 deg. spatial divergence, and {approx}50% energy conversion efficiency from the laser.

43 PARTICLE ACCELERATORS↗

Room temperature deposition of superconducting NbN for superconductor-insulator-superconductor junctions

The deposition of stoichiometric B1-crystal-structure (111) NbN films on glass or sapphire substrates by reactive dc magnetron sputtering is reported. High-purity Ar-N2 mixtures are used in the apparatus described by Thakoor et al. (1985), and typical deposition parameters are given as background pressure about 10 ntorr, voltage -325 V, current 1 A, deposition rate 1.35 nm/s, film thickness 500 nm, P(Ar) 5-17 mtorr, initial P(N2) 2-6 mtorr, and room temperature. The N2 consumption-injection characteristics are studied and found to control NbN formation using well-conditioned Nb targets. Films with transition temperatures 15-16 K are obtained at P(Ar) = 12.9 + or - 0.2 mtorr and P(N2) = 3.7 + or - 0.1 mtorr. SIS junctions of area about 0.001 sq cm fabricated using the NbN films are shown to have I-V characteristics with nonlinearity parameter about 110 and NbN superconducting-gap parameter Delta = about 2.8 meV.

Thakoor, S.↗

Touchdown on Titan

Europe's Huygens probe is on target for a Dec. 25 separation from the Cassini Saturn orbiter that has carried it like a baby for more than seven years. The probe will spend three weeks coasting to a plunge into Titan's thick atmosphere on the morning of Jan. 14. If all goes as planned, the 349-kg. Huygens will spend more than 2 hr. descending by parachute to the mysterious surface of the planet-sized moon, and hopefully devote yet more time to broadcasting data after it lands. Before the day is over, Huygens is programmed to beam about 30 megabytes of data - including some 1,100 images-back to Earth through Cassini, a trip that will take some 75 min. to complete over the 1- billion-km. distance that separates the two planets. Within that data should be answers to questions that date back to 1655, when Dutch astronomer Christiaan Huygens found the moon with a homemade telescope and named it for the family of giants the ancient Greeks believed once ruled the earth. In the Solar System, there is no other world like Titan, with a nitrogen and methane atmospheric and a cold, hidden surface darker than Earth under the full Moon.

Morring, Frank, Jr.↗

Experimentally Shocked and Altered Basalt: VNIR Spectra of Mars Analog Materials

Major occurrences of hydrous alteration minerals on Mars have been found in Noachian impact craters formed in basaltic targets and detected using visible/near infrared (VNIR) spectroscopy. Until recently phyllosilicates were detected only in craters in the southern hemisphere. However, it has been reported that at least nine craters in the northern plains apparently excavated thick layers of lava and sediment to expose phyllosilicates as well and two Hesperian-aged impact craters, Toro and Majuro, bear evidence of phyllosilicates in the southern highlands. Turner et al. 2015 reported that hydrated minerals were identified in three Amazonian aged complex impact craters, located at 52.42degN, 39.86degE in the Ismenius Lacus quadrangle, at 8.93degN, 141.28degE in Elysium, and within Stokes crater. These discoveries indicate that Mars was globally altered by water throughout its past but do not fully constrain formation conditions for phyllosilicate occurrences which have important implications for the evolution of the surface and biological potential of Mars.

Bell, M. S.↗

Astro-biological Exploration of Ocean Worlds, Enabled by an RPS Inside a Pressure Vessel

Exploring Ocean and Ice Worlds could help us to understand the origin and evolution of life in the universe. In our solar system we have identified six Ocean and Ice Worlds, namely Earth, Europa, Ganymede, Callisto, Enceladus, and Titan. Other potential targets include Dione, Triton, and Pluto. As documented in the Planetary Decadal Survey [1] and the NASA Roadmap to Ocean Worlds [2], these worlds are compelling science destinations, with oceans situated below their tens of kilometers thick ice shells. To reach them we need a new exploration paradigm with novel technological solutions. Key technological challenges revolve around the power for the probe and for melting, as well as protecting the payload against the extreme environments, including high pressure, low temperature, corrosion, and radiation. Far away from the Sun, and melted into the ice, we may only rely on long-lived internal power generation. Radioisotope Power Systems (RPS) with either static or dynamic conversion, utilizing the heat of decaying Plutonium-238, could be good candidates. We need suitable payloads that are protected and could survive the extreme environments, as well as enabling power and thermal systems for melting through the ice shield and to swim in the ocean below the ice. RPS could support the probe’s instruments and sub-systems, as well as provide a heat source for melting the ice while keeping the components at operating temperatures. Mitigating the external pressure while immersing inside the ice shell, and in the ocean, would require a new RPS design that operates inside a Pressure Vessel. In our paper, we will discuss general mission architecture trades and the sizing of a next generation RPS housed in a pressure vessel, broadly applicable to any of the Ocean Worlds satellites of interest. Through a technology focused approach, we address interconnected design and mission architecture aspects, including considerations for: the RPS and the Pressure Vessel; extreme environmental constraints; g-load tolerance; power and thermal systems sizing for science measurements; spacecraft operations through all mission phases; subsurface mobility; and planetary protection. The findings will inform the science community on instrument accommodation possibilities; the mission planning community on possible mission concepts; and the RPS development community on the science driven technology considerations.

Donitz, Benjamin P.↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗