At least 1,549 records · Page 86

The vertical distribution of Mars water vapor

Analysis of observations made from the Viking 1 Orbiter indicates that the water vapor over the Viking 1 landing site is uniformly mixed with the atmosphere and not concentrated near the surface. The analysis incorporates the effects of atmospheric scattering and explains why previous earth-based observations showed a strong diurnal variation in water content. It also explains the lack of an early morning fog and removes the necessity of daily exchange of large amounts of water between the surface and the atmosphere. A water vapor volume mixing ratio of 1.5 x 10 to the -4th is inferred for the Viking 1 site in late summer.

Davies, D. W.↗

Characteristics of a CW water vapor laser at 118 and 28 microns

The characteristics of a CW water vapor laser operating at 118 and 28 microns are reported. By monitoring the discharge current, helium gas pressure, and water vapor pressure, a criterion for optimum power output has been obtained. Peak powers of 6 and 114 mW are obtained, respectively, for the 118- and 28-micron lines for a 4.5-m discharge tube.

Yasuoka, Y.↗

Detonation-flame arrester devices for gasoline cargo vapor recovery systems

Empirical data on the deflagration-to-detonation run-up distance for flowing mixtures of gasoline and air in 15.2-cm- (6.0-in.-) diameter piping simulating a vapor recovery system are presented. The quenching capability of eight selected flame control devices subjected to repeated stable detonations was evaluated. The successful detonation-flame arresters were: (1) spiral-wound, crimped aluminum ribbon, (2) foamed nickel-chrome metal, (3) vertically packed bed of aluminum Ballast rings, and (4) water-trap or hydraulic back-pressure valve. Installation configurations for two of the more applicable arresters, the spiral-wound, crimped stainless-steel ribbon and the vertically packed bed of aluminum Ballast rings, were further optimized by a series of parametric tests. The final configuration of these two arresters was demonstrated with repeated detonation tests at conditions that simulated vapor recovery system operation. On these tests, the combustible mixture of gasoline and air continued to flow through the piping for periods up to 120 seconds after the initial detonation had been arrested. There was no indication of continuous burning or reignition occurring on either side of the test arresters.

Bjorklund, R. A.↗

A model for chemical and isotopic fractionation in the lunar regolith by impact vaporization

Up until now there has been no complete model of chemical and isotopic fractionation effects which could occur in the lunar regolith as a result of hypervelocity impact vaporization. Previous work on the outlines for such a model are extended and show that impact vaporization could be an efficient mechanism for producing heavy isotope enrichments. Rough qualitative predictions based on the model show a general similarity to the observations on lunar samples.

Housley, R. M.↗

Computer simulated rate processes in copper vapor lasers

A computer model for metal vapor lasers has been developed which places emphasis on the change of excited state populations of the lasant through inelastic collisions and radiative interaction. Also included are an energy equation for the pumping electrons and rate equations for laser photon densities. Presented are results of calculations for copper vapor with a neon buffer over a range of conditions. General agreement with experiments was obtained.

Harstad, K. C.↗

Remote sensing of atmospheric water vapor, liquid water, and wind speed at the ocean surface by passive microwave techniques from the Nimbus 5 satellite

The microwave brightness temperature measurements for Nimbus 5 electrically scanned microwave radiometer (ESMR) and Nimbus-E microwave spectrometer (NEMS) are used to retrieve the atmospheric water vapor, liquid water, and wind speed by a quasi-statistical retrieval technique. It is shown that the brightness temperature can be utilized to yield these parameters under various weather conditions. Observations at 19.35, 22.235, and 31.4 GHz were input to the regression equations. The retrieved values of these parameters for portions of two Nimbus 5 orbits are presented. Then comparison between the retrieved parameters and the available observations on the total water vapor content and the surface wind speed are made.

Chang, A. T. C.↗

Vapor chambers for an atmospheric cloud physics laboratory

The methanol/stainless steel vapor chambers (flat-plate heat pipes) discussed in this paper were developed for use in spaceborne atmospheric cloud chambers. This application imposed stringent thermal and mechanical requirements on the design. Flatness, low thermal mass, vibration, and structural integrity requirements were achieved in addition to precision temperature uniformity and thermal transport. Heat transfer coefficients on the order of 0.34 to 0.40 W/sq cm -C were measured. The vapor chambers are capable of transporting 170 W-cm per cm of width in either the axial or side-to-side direction.

Fleischman, G. L.↗

Heat-Exchange Fluids for Sulfuric Acid Vaporizers

Some fluorine-substituted organic materials meet criteria for heat-exchange fluids in contact with sulfuric acid. Most promising of these are perfluoropropylene oxide polymers with degree of polymerization (DP) between 10 and 50. It is desirable to have DP in high range because vapor pressure of material decreases as DP increases, and high-DP liquids have lower loss due to vaporization.

Lawson, D. D.↗

Analysis of effect of flameholder characteristics on lean, premixed, partially vaporized fuel-air mixtures quality and nitrogen oxides emissions

An analysis was conducted of the effect of flameholding devices on the precombustion fuel-air characteristics and on oxides of nitrogen (NOx) emissions for combustion of premixed partially vaporized mixtures. The analysis includes the interrelationships of flameholder droplet collection efficiency, reatomization efficiency and blockage, and the initial droplet size distribution and accounts for the contribution of droplet combustion in partially vaporized mixtures to NOx emissions. Application of the analytical procedures is illustrated and parametric predictions of NOx emissions are presented.

Cooper, L. P.↗

Catalytic combustion with incompletely vaporized residual fuel

Catalytic combustion of fuel lean mixtures of incompletely vaporized residual fuel and air was investigated. The 7.6 cm diameter, graded cell reactor was constructed from zirconia spinel substrate and catalyzed with a noble metal catalyst. Streams of luminous particles exited the rector as a result of fuel deposition and carbonization on the substrate. Similar results were obtained with blends of No. 6 and No. 2 oil. Blends of shale residual oil and No. 2 oil resulted in stable operation. In shale oil blends the combustor performance degraded with a reduced degree of fuel vaporization. In tests performed with No. 2 oil a similar effect was observed.

Rosfjord, T. J.↗

Airborne differential absorption lidar system for water vapor investigations

Range-resolved water vapor measurements using the differential-absorption lidar (DIAL) technique is described in detail. The system uses two independently tunable optically pumped lasers operating in the near infrared with laser pulses of less than 100 microseconds separation, to minimize concentration errors caused by atmospheric scattering. Water vapor concentration profiles are calculated for each measurement by a minicomputer, in real time. The work is needed in the study of atmospheric motion and thermodynamics as well as in forestry and agriculture problems.

Browell, E. V.↗

Computations of transmittance and radiance in infrared water vapor sounding channels

The wing-scaling approximation/k-distribution method, previously developed for computing solar heating rates (Chou and Arking, 1981) was applied to the computation of the transmittance and outgoing radiance in infrared water vapor sounding channels. Functions necessary for the transmittance and radiance computations were computed from molecular line parameters using line-by-line methods. The method was applied to the three HIRS/2 water vapor sounding channels on the TIROS-N satellite, and its accuracy was tested using 11 widely separated atmospheres which ranged from hot-wet tropical atmospheres to cold-dry subarctic atmospheres. Compared to line-by-line calculations, maximum errors were shown to be less than 0.017 in transmittance and 0.4 K in brightness temperature for all cases. The rms errors are less than 0.009 in transmittance and 0.2 K in brightness temperature, the brightness temperature rms error being much smaller than the instrument noise.

Chou, M.-D.↗

Measurements of water vapor in Mars' antarctic

A complete Mars year of measurements of atmospheric water vapor in the south arctic have been obtained from the Viking Orbiters. Analysis of the observations indicates that, except for the south remnant cap, the southern hemisphere of Mars is devoid of any substantial reservoirs of water in contact with the atmosphere, and that, in the summer time, the top layer of soil is desiccated. Small amounts of water ice are incorporated into the annual CO2 cap; this water is released at the cap margin when it retreats in the spring. The first global dust storm resulted in heating of the south arctic atmosphere and a transport of water in from the equatorial region. The second global dust storm had a negligible effect on atmospheric water vapor; the dust contained little water.

Davies, D. W.↗

An efficient method for computing the absorption of solar radiation by water vapor

Chou and Arking (1980) have developed a fast but accurate method for computing the IR cooling rate due to water vapor. Using a similar approach, the considered investigation develops a method for computing the heating rates due to the absorption of solar radiation by water vapor in the wavelength range from 4 to 8.3 micrometers. The validity of the method is verified by comparison with line-by-line calculations. An outline is provided of an efficient method for transmittance and flux computations based upon actual line parameters. High speed is achieved by employing a one-parameter scaling approximation to convert an inhomogeneous path into an equivalent homogeneous path at suitably chosen reference conditions.

Chou, M.-D.↗

Numerical modeling of diffusive physical vapor transport in cylindrical ampoules

Diffusion limited physical vapor transport in closed cylindrical ampoules of aspect ratio (length/radius) between 0.5 and 10 was studied numerically. The transport of a crystal forming component A through an inert component B, which undergoes zero net transport, was considered. A case in which the partial pressure of B is comparable to that of A, as well as systems with very low partial pressures of B (impurity cases) were treated. Concentrations and velocity distributions were obtained from the coupled transport equations for momentum, mass and components. It was found that the interdiffusion of components in viscous interaction with the container walls leads to (1) recirculation of component B, even in the absence of gravity; (2) concentration gradients normal to the main transport direction in the vapor space; and (3) non-uniform interfacial concentration gradients and, hence, non-uniform crystal growth rates.

Greenwell, D. W.↗

Numerical modeling of diffusive-convective physical vapor transport in cylindrical vertical ampoules

Diffusive-convective physical vapor transport (PVT) in cylindrical, vertical ampoules of aspect ratio (length/radius) between 0.5 and 10 was modeled numerically. The transport of a crystal forming component through an inert component that undergoes zero net transport was considered. Systems were treated in which: (1) with unequal molecular weight of the components and with temperature gradients typically employed in PVT, convective flow arises dominantly from solutal density gradients; and (2) with equal molecular weight of the components, convective flow can arise only from thermal expansion. It was found that, due to the diffusion-induced horizontal density gradients, buoyancy-driven convective flows are superimposed on the diffusive-advective fluxes without threshold. Net recirculation sets in adjacent to the growing interface, in contrast to the corresponding monocomponent situation where marginally stable convective modes fill the whole fluid space. Depending on the orientation of the main transport direction with respect to gravity, convection can either reduce or enhance the diffusion-induced radial concentration gradients. Significant enhancement of the net transport rate was found to occur only when the whole vapor space between source and growing crystal is filled by a convective recirculation roll. Solutal and thermal convection results are similar; yet for quantitative discussions, thermal and solutal Rayleigh numbers are not interchangeable in contrast to convective situations that lack net mass transport across the fluid space.

Markham, B. L.↗

Water-Vapor Sample Holder for Mass Spectrometers

Water-vapor sample holder for mass spectrometer contains water vapor for calibration. It is sealed by aluminum disk. Calibration sample and integrated circuit modules are tested sequentially in same manner.

Haack, R. F.↗