An ion source module for the Beijing Radioactive Ion-beam Facility

An ion source module is developed for Beijing Radioactive Ion-beam Facility. The ion source module is designed to meet the requirements of remote handling. The connection and disconnection of the electricity, cooling and vacuum between the module and peripheral units can be executed without on-site manual work. The primary test of the target ion source has been carried out and a Li{sup +} beam has been extracted. Details of the ion source module and its primary test results are described.

43 PARTICLE ACCELERATORS↗

The Effects of Gamma Ray Integrated Dose on a Commercial 65-nm SRAM Device

Here this work shows that the static random access memory (SRAM) error rate for a commercial 65-nm device in a dose rate environment can be highly dependent upon the integrated dose (dose rate × pulse duration). While the typical metric for such testing is dose rate upset (DRU) level in rad(Si)/s, a series of dose rate experiments at Little Mountain Test Facility (LMTF) shows dependence on the integrated dose. The error rate is also found to be dependent on the core voltage, and the preradiation value of the bits. We believe that these effects are explained by a well charge depletion caused by gamma ray photocurrent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase II Outer Tracker Upgrade at Fermilab

The Large Hadron Collider (LHC) will be upgraded to increase the instantaneous luminosity up to 5−7.5×10 34 cm −2 s −1 . To face these challenging conditions the CMS tracking system must be updated, using modules that on the one hand are able to cope with high radiations and on the other hand can provide information to the L-1 trigger selection. This report describes the results of some tests on the new tracking modules at the FNAL test beam facility. In particular half of one module was irradiated by 400 MeV protons (total fluence comparable to the one expected through the lifetime of the experiment) and then some analysis were performed on both the irradiated and not irradiated side of the detector with a 120 GeV proton beam. In this report, the efficiency and noise occupancy analysis are presented, with focus on the main critical issues encountered.

43 PARTICLE ACCELERATORS↗

Compact X-band split electron linac for cabinet-size small-sample irradiators

Many small-scale industrial radiation facilities rely on hazardous radioisotope-based gamma ray irradiators, which are being gradually replaced by alternative technologies, such as particle accelerators. RadiaBeam has developed a compact, cabinet-size, 3 MeV electron-linac-based irradiator to match the penetration of Co-60 and provide high irradiation throughput. Here the linac utilizes X-band RF power to reduce size, employs an innovative split-linac approach to lower costs, and features a novel X-ray conversion target geometry that spreads the beam out across the target, providing a low dose uniformity ratio. In this paper, we discuss the accelerator design, fabrication, and test results.

43 PARTICLE ACCELERATORS↗

AI-Enhanced Computational Tools for Entry Systems Modeling

To advance the understanding of complex atmospheric entry phenomena, NASA’s Entry Systems Modeling (ESM) team [1] has developed high-fidelity computational tools addressing multiscale challenges, from material microstructures to full-scale heatshield response. This abstract highlights a subset of ESM tools, focusing on AI integration to enhance workflows and predictive modeling. - PuMA [2] computes effective material properties from high-resolution micro-CT scans, supporting TPS analysis for NASA missions. - TomoSAM [3] automates 3D tomography dataset segmentation for PuMA using the Segment Anything Model, reducing manual effort and improving accuracy. - PATO [4] models porous reactive materials under extreme conditions, with advancements such as unified solvers, mechanical erosion, and TPS coatings for NASA missions. - arcjetCV [5] employs deep learning to analyze arc jet test footage, measuring recession rates, shape changes, and shock standoff distances, bridging simulations, and experiments to reveal TPS ablation behavior. - ARCHeS [6] simulates arc heater plasma flows, modeling turbulence, radiation, and electromagnetic interactions to optimize arc heater performance, validate TPS under extreme conditions, and serve as a foundation for developing digital twins of arc heater facilities. - SPARTA [7] simulates rarefied hypersonic flows and gas-surface interactions for planetary entry missions, leveraging GPU architectures for scalable and efficient aerothermal and ablation analyses. AI-driven solutions, such as deep learning segmentation, have streamlined workflows in ESM tools and still hold significant potential to further accelerate processes and enhance automation in entry systems modeling. [1] Haskins, J.B. (2023), [2] Ferguson, J.C. (2018), [3] Meurisse, J.B.E. (2018), [4] Semeraro, F. (2023), [5] Quintart, A. (2024) [6] Meurisse, J.B.E. (2022), [7] Plimpton, S.J. (2019)

Predictive Modeling↗

Surrogate Assembly 30 cm Drop Test

The 30 cm drop is the remaining NRC normal conditions of transport (NCT) regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. While obtaining data on the actual fuel is not a direct requirement, it provides definitive information which aids in quantifying the risk of fuel breakage resulting from a cask drop from a height of 30 cm or less. The 30 cm drop test with the full-scale surrogate assembly conducted in May 2020 was the last step needed for quantifying the strains on the surrogate assembly rods under NCT. The full-scale surrogate assembly used in the 2020 30 cm drop test was built using a new 17x17 Pressurized Water Reactor (PWR) Westinghouse skeleton filled with the copper rods and 3 zircaloy rods from the full-scale surrogate assembly used in the Multi-Modal Transportation Test (MMTT). Felt pads were attached to the surrogate assembly bottom prior to the 30 cm drop to adequately represent the effects of the impact limiters and the cask. Note that felt "programming material" has been used extensively in past drop tests and is known to be a good material for programming a desired shock pulse. The felt pad configuration was determined during a previous series of tests reported in. The acceleration pulses observed on the surrogate assembly during the test were in good agreement with the expected pulses. This confirmed that during the 30 cm drop the surrogate assembly experienced the same conditions as it would if it was dropped in the cask with the impact limiters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerating computing for the future electric grid (CRADA Final Report)

As a participant in the Cyclotron Road Lab-Embedded Entrepreneurship Program (LEEP), Vellex Computing, Inc. has successfully validated the "Vellex Computing Stack," a breakthrough Analog Neural Computer (ANC) specifically designed for high-performance edge optimization. This project achieved critical milestones in mixed-signal circuit stability and software-hardware co-design, directly addressing national priorities in semiconductor resiliency. The success of this work is deeply rooted in the support from the Cyclotron Road LEEP, which provided the essential "hard tech" runway—funding, mentorship, and access to Lawrence Berkeley National Laboratory’s world-class characterization facilities—allowing Vellex to overcome the "Valley of Death" often faced by deep-tech hardware startups. By leveraging LBNL’s advanced testing infrastructure, Vellex was able to rigorously benchmark the ANC architecture against state-of-the-art digital solutions, a feat that would have been resource-prohibitive independently. This collaboration has not only advanced American leadership in analog computing but has also matured Vellex’s technology to a stage ripe for private sector commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closeout of CRADA JSA 2012S004: Chapter 5, Integrated Control System, of the document of the ESS Conceptual Design Report, publicly available at https://europeanspallationsource.se/accelerator-documents

The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED database management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

PEP Integrated Test D Run Report Caustic and Oxidative Leaching in UFP-VSL-T02A

Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes" of the External Flowsheet Review Team (EFRT) issue response plan. The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario (Test B and D) has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario (Test A) has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP VSL-00001A and B in the WTP PTF). In Test D, 19M sodium hydroxide (NaOH, caustic) was added to the waste slurry in the UFP VSL T02 vessel after the solids were concentrated to ~20% undissolved solids. The NaOH was added to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by heating to 85°C using direct injection of steam to accelerate the leach process. The main difference of Test D compared to Test B is that the leach temperature is 85°C for 24 hrs as compared to 100°C for 12 hours. The other difference is the Test D simulant had Cr in the simulant from the start of processing and Test B had Cr added to adjust the simulant composition after aluminum leaching. Following the caustic leach, the UFP-VSL-T02A vessel contents are cooled using the vessel cooling jacket. The slurry was then concentrated to 17 wt% undissolved solids and washed with inhibited water to remove NaOH and other soluble salts. Next, the slurry was oxidatively leached using sodium permanganate to solubilize chrome. The slurry was then washed to remove the dissolved chrome and concentrated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Memorandum of Understanding for the 2007 Meson Test Beam Program: Tests of LHCb Silicon Detectors

This Memorandum of Understanding applies to the use of the FNAL Meson Test Beam Facility to study the performance of several LHCb silicon vertex detectors. The tests will be carried out as a collaborative effort of CERN, Glasgow, Liverpool, and Syracuse Universities. The Vertex Locator (VELO) of the LHCb detector uses short silicon strips in a unique geometry that features strips at constant radial distance from the beam line and strips at almost constant azimuthal angle. The Silicon detectors in use at LHCb are implemented with n strips on n substrates. Prototype replacement sensors, however, have been produced using n strips on p substrates. The new processing scheme offers the prospect of producing significantly lower cost detectors for future projects and possibly better performance especially of irradiated sensors. The experimenters wish to compare the performance of the n-on-n and n-on-p detectors for irradiated and non-irradiated sensors. To do so, the experimenters plan to use the pixel telescope being constructed in the MTest facility. In particular, the experimenters are planning to study the efficiency of the irradiated and unirradiated devices and the spatial resolution as a function of the track incident angle. They vary over the sensor area due to the unusual geometry. The experimenters will also change the incident angle of the beam by moving the sensors, to investigate how the resolution varies with angle. Besides VELO sensors, some n-on-p sensors are available from the RD50 collaboration at CERN. Many physicists participating in this test beam are members ofRD50. This memorandum is intended solely for the purpose of providing a work allocation for Fermi National Accelerator Laboratory and the participating universities and institutions. It reflects an arrangement that is currently satisfactory to the parties involved. It is recognized, however, that changing circumstances of the evolving research program may necessitate revisions. The parties agree to negotiate amendments to this memorandum to reflect such revisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and Acoustic Numerical Modeling of a Curved Composite Honeycomb Panel

The finite and boundary element modeling of the curved section of a composite honeycomb aircraft fuselage sidewall was validated for both structural response and acoustic radiation. The curved panel was modeled in the pre-processor MSC/PATRAN. Geometry models of the curved panel were constructed based on the physical dimensions of the test article. Material properties were obtained from the panel manufacturer. Finite element models were developed to predict the modal parameters for free and supported panel boundary conditions up to a frequency of 600 Hz. Free boundary conditions were simulated by providing soft foam support under the four comers of the panel or by suspending the panel from elastic bands. Supported boundary conditions were obtained by clamping the panel between plastic tubing seated in grooves along the perimeter of a stiff and heavy frame. The frame was installed in the transmission loss window of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center. The structural response of the curved panel due to point force excitation was predicted using MSC/NASTRAN and the radiated sound was computed with COMET/Acoustics. The predictions were compared with the results from experimental modal surveys and forced response tests on the fuselage panel. The finite element models were refined and updated to provide optimum comparison with the measured modal data. Excellent agreement was obtained between the numerical and experimental modal data for the free as well as for the supported boundary conditions. Frequency response functions (FRF) were computed relating the input force excitation at one panel location to the surface acceleration response at five panel locations. Frequency response functions were measured at the same locations on the test specimen and were compared with the calculated FRF values. Good agreement was obtained for the real and imaginary parts of the transfer functions when modal participation was allowed up to 3000 Hz. The validated finite element model was used to predict the surface velocities due to the point force excitation. Good agreement was obtained between the spatial characteristics of the predicted and measured surface velocities. The measured velocity data were input into the acoustic boundary element code to compute the sound radiated by the panel. The predicted sound pressure levels in the far-field of the panel agreed well with the sound pressure levels measured at the same location.

Grosveld, Ferdinand W.↗

BPM System for the PIP-II Injector Test Facility

A new BPM system was used for commissioning and operation of the PIP2 Injector Test Facility. The system of 13 warm and 12 cold BPMs was based upon custom 250 MS/s digitizers controlled and readout over gigabit ethernet by a single multi-core rackmount server running linux. The system provided positions, intensity, and phase for each bpm as a pulse average or pulse waveform from 10 us to 4 ms at a 20 Hz pulse repetition rate.

43 PARTICLE ACCELERATORS↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oak Ridge Response to Versatile Test Reactor Environmental Impact Statement Data Request

The Versatile Test Reactor (VTR) is a fast-spectrum test reactor being developed in the United States under the direction of the US Department of Energy Office of Nuclear Energy (DOE-NE). The VTR mission is to enable accelerated testing of advanced reactor fuels and materials required for advanced reactor technologies. The conceptual design of the 300 MWth sodium-cooled metallic-fueled pool-type fast reactor has been led by the US National Laboratories in collaboration with General Electric–Hitachi and Bechtel National, Inc. In support of the VTR project, DOE issued a Notice of Intent (NOI) in the Federal Register on August 5, 2019, announcing the intent to prepare an Environmental Impact Statement (EIS) in accordance with the National Environmental Policy Act (NEPA) and its implementing regulations. The EIS will evaluate alternatives for a versatile reactor–based fast-neutron source facility and associated facilities for the preparation, irradiation, and post-irradiation examination (PIE) of test/experimental fuels and materials. Specifically, the NOI identified two siting alternatives for the VTR reactor facility: Idaho National Laboratory (INL) or Oak Ridge National Laboratory (ORNL). In addition, the NOI also specified two siting alternatives for VTR fuel fabrication: INL and the Savannah River Site (SRS). This report provides information in response to data requests made to ORNL to fill in site-specific knowledge gaps to develop a high-quality EIS. The responses provided are not required to provide full details in every aspect; instead, they adequately bound possible environmental impacts or provide sufficient information to adequately assess likely environmental impacts. This work is being performed under a subcontract from INL to ORNL using DOE-NE funds and is directed by DOE-NE and DOE-ID. Leidos has been contracted by DOE-NE to write the VTR EIS, so most data requests have come from Leidos but were often routed through INL or DOE-ID. DOE-ID is overseeing the NEPA and EIS processes for the VTR project. Leidos will use the information provided in this report to inform the VTR EIS and will also cite this document to establish a clear, publicly available source of the information. Section 2 of this report briefly describes the proposed ORNL VTR Alternative and illustrates the location of the proposed site for the ORNL VTR Alternative. Sections 3 through 7 provide direct responses to data requests received by ORNL. These sections use a tabular format in which data requests are divided into separate items to be addressed; the items are numbered, the data requests are restated with more topical information included, and then the responses are provided. Initial data requests and follow-on requests for additional information (RAIs) are combined under the original data request fields. Finally, Section 8 presents summarized conclusions and describes future work.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advances in Non-contact Measurement of Creep Properties

Our team has developed a novel approach to measuring creep at extremely high temperatures using electrostatic levitation (ESL). This method has been demonstrated on niobium up to 2300 C, while ESL has melted tungsten (3400 C). High-precision machined spheres of the sample are levitated in the NASA MSFC ESL, a national user facility, and heated with a laser. The laser is aligned off-center so that the absorbed photons transfer their momentum to the sample, causing it to rotate at up to 250,000+ RPM. The rapid rotation loads the sample through centripetal acceleration, causing it to deform. The deformation of the sample is captured on high-speed video, which is analyzed by machine-vision software from the University of Massachusetts. The deformations are compared to finite element models to determine the constitutive constants in the creep relation. Furthermore, the noncontact method exploits stress gradients within the sample to determine the stress exponent in a single test. This method was validated in collaboration with the University of Tennessee for niobium at 1985 C, with agreement within the uncertainty of the conventional measurements. A similar method is being employed on Ultra-High-Temperature ZrB2- SiC composites, which may see application in rocket nozzles and sharp leading edges for hypersonic vehicles.

Hyers, Robert W.↗

Variable Depth Bragg Peak Method for Single Event Effects Testing

Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured and the corresponding LET calculated from the change in degrader thickness. That information is used to generate a plot of cross-section as a function of ion LET. The advantages of this approach are that the part does not have to be de-lidded and a broad range of LETs is available from a single heavy ion without having to go to non-normal angles of incidence to change the "effective" LET. As we will show, it is possible to obtain an entire curve of cross-section versus LET using just two or three ions. Fig. 1 shows curves of cross-section vs LET for a Freescale 4 Mbit SOI/SRAM measured at the 88" Cyclotron at Berkeley and at NSRL. The open symbols are the data obtained from Berkeley for top-side and back-side irradiation. The solid data points are for the data obtained at NSRL using a device for which the package was intact. The data are for Iron and Gold and cover a range of LETs from 4 MeV.cm2/mg to 84 MeV.cm2/mg. The agreement between the data obtained from Berkeley and from NSRL is excellent, demonstrating that the VDBP method is capable of providing accurate values of cross-section versus LET, at least for the 4 Mbit SRAM. Details of the technique will be included in the final presentation.

Buchner, S.↗

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot↗

High energy particle detection with large area superconducting microwire array

We present the first detailed study of an 8-channel2×2 mm$^{2}$ WSi superconducting microwire single photondetector (SMSPD) array exposed to 120 GeV proton beam and 8 GeVelectron and pion beam at the Fermilab Test Beam Facility. TheSMSPD detection efficiency was measured for the first time forprotons, electrons, and pions, enabled by the use of a silicontracking telescope that provided precise spatial resolution of30 μm for 120 GeV protons and 130 μm for 8 GeVelectrons and pions. The result demonstrated consistent detectionefficiency across pixels and at different bias currents. Timeresolution of 1.15 ns was measured for the first time for SMSPDwith proton, electron, and pions, enabled by the use of an MCP-PMTwhich provided a ps-level reference time stamp. The resultspresented is the first step towards developing SMSPD array systemsoptimized for high energy particle detection and identification forfuture accelerator-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗