Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular independent silicon detector for dosimetry in external beam radiotherapy

Purpose: In this work, the “edgeless” silicon detector technology is investigated, in combination with an innovative packaging solution, to manufacture silicon detectors with negligible angular response. The new diode is also characterized as a dosimeter for radiotherapy with the aim to verify its suitability as a single detector for in vivo dosimetry as well as large area 2D array that does not require angular correction to their response. Methods: For the characterisation of the “edgeless-drop-in” detector technology, a set of samples have been manufactured with different sensitive areas (1 × 1 and 0.5 × 0.5 mm{sup 2}) and different thicknesses (0.1 and 0.5 mm) in four different combinations of top and peripheral p–n junction fabricated on p-type and n-type silicon substrates. The diode probes were tested in terms of percentage depth dose (PDD), dose rate, and linearity and compared to ion chambers. Measurements of the output factor have been compared to film. The angular response of the diodes probes has been tested in a cylindrical PMMA phantom, rotated with bidirectional accuracy of 0.25° under 10 × 10 cm{sup 2} 6 MV Linac photon beam. The radiation hardness has been investigated as well as the effect of radiation damage on the angular and dose rate response of the diode probes when irradiated with photons from a Co-60 gamma source up to dose of 40 kGy. Results: The PDDs measured by the edgeless detectors show an agreement with the data obtained using ion chambers within ±2%. The output factor measured with the smallest area edgeless diodes (0.5 × 0.5 mm{sup 2}—0.1 and 0.5 mm thick) matches EBT3 film to within 2% for square field size from 10 to 0.5 cm side equivalent distance. The dose rate dependence in a dose per pulse range of 0.9 × 10{sup −5}–2.7 × 10{sup −4} Gy/pulse was less than −7% and +300% for diodes fabricated on p-type and n-type substrates, respectively. The edgeless diodes fabricated on the p-type substrate demonstrated degradation of the response as a function of the irradiation dose within 5%–15%, while diodes on the n-type substrate show a variation of approximately 30% after 40 kGy. The angular response of all probes is minimal (within 2%) but the N on N and P on P configurations show the best performances with an angular dependence of ±1.0% between 0° and 180° in the transversal direction. In this configuration, the space charge region of the passive diode extends from the behind and sidewall toward the anode on the top providing beneficial electric field distribution in the peripheral area of the diode. Such performance has also been tested after irradiation by Co-60 up to 40 kGy with no measurable change in angular response. Conclusions: A new edgeless-drop-in silicon diode fabrication and packaging technology has been used to develop detectors that show no significant angular dependence in their response for dosimetry in radiation therapy. From the characterisation of the diodes, proposed in a wide range of different geometries and configurations, the authors recommend the P-on-P detectors in conjunction with “drop in” packaging technology as the candidate for further development as single diode probe or 2D diode array for dosimetry in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Pixel-to-pixel variation on a calibrated PILATUS3-based multi-energy soft x-ray detector

A multi-energy soft x-ray pin-hole camera based on the PILATUS3 100 K x-ray detector has recently been installed on the Madison Symmetric Torus. This photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the photon lower-threshold cutoff energy Ec can be independently set for each pixel. This capability allows the measurement of plasma x-ray emissivity in multiple energy ranges with a unique combination of spatial and spectral resolution and the inference of a variety of important plasma properties (e.g., Te, nZ, Zeff). The energy dependence of each pixel is calibrated for the 1.6–6 keV range by scanning individual trimbit settings, while the detector is exposed to fluorescence emission from Ag, In, Mo, Ti, V, and Zr targets. The resulting data for each line are then fit to a characteristic “S-curve” which determines the mapping between the 64 possible trimbit settings for each pixel. The statistical variation of this calibration from pixel-to-pixel was explored, and it was found that the discreteness of trimbit settings results in an effective threshold resolution of ΔE < 100 eV. A separate calibration was performed for the 4–14 keV range, with a resolution of ΔE < 200 eV.

VanMeter, P. (ORCID:0000000244537948)↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Search for Pauli exclusion principle violating atomic transitions and electron decay with a p-type point contact germanium detector

Here, a search for Pauli-exclusion-principle-violating K α electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8 × 10 30 s at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the X-ray and Auger electrons present following the transition. A similar analysis was done to look for the decay of atomic K-shell electrons into neutrinos, resulting in a lower limit of 6.8 × 10 30 s at 90% C.L. It is estimated that the Majorana Demonstrator, a 44 kg array of p-type point contact detectors that will search for the neutrinoless double-beta decay of 76 Ge, could improve upon these exclusion limits by an order of magnitude after three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution Performance of HERA-B Lead-Glass Calorimeters

In preparation of upcoming 12GeV experiments at Thomas Jefferson National Accelerator Facility it is necessary to upgrade existing systems or install new detectors. As part of this effort, an array of lead-glass sampling calorimeters is need for use in the GEP-5 experiment. A sampling calorimeter can be used to determine the energy and spatial position of a high energy particle that enters it while simultaneously stopping the particle. To determine the appropriate construction to meet the needs of upcoming experiments, it was necessary to take an existing model and confirm its energy and position resolution. This model could then be confirmed as an option for the final construction, or used as a starting point to design a better detector. For our test we obtained ten lead-glass calorimeters used in HERA-B and tested them in End Station A at SLAC. I will report on our findings for the HERA-B lead-glass sampling calorimeters. I will cover the results of both the energy and position resolutions as well as the methods used to determine these quantities.

Losada, Anthony↗

Performance Testing using Silicon Devices - Analysis of Accuracy: Preprint

Accurately determining PV module performance in the field requires accurate measurements of solar irradiance reaching the PV panel (i.e., Plane-of-Array - POA Irradiance) with known measurement uncertainty. Pyranometers are commonly based on thermopile or silicon photodiode detectors. Silicon detectors, including PV reference cells, are an attractive choice for reasons that include faster timeresponse (10 us) than thermopile detectors (1 s to 5 s), lower cost and maintenance. The main drawback of silicon detectors is their limited spectral response. Therefore, to determine broadband POA solar irradiance, a pyranometer calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under clear-skyconditions with respect to a broadband reference radiometer. The pyranometer is then used for various scenarios including varying airmass, panel orientation and atmospheric conditions. This would not be an issue if all irradiance wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately, the scattering and absorption signature varies widely withwavelength and the calibration factor for the silicon photodiode pyranometer is not appropriate for other conditions. This paper reviews the issues that will arise from the use of silicon detectors for PV performance measurement in the field based on measurements from a group of pyranometers mounted on a 1-axis solar tracker. Also we will present a comparison of simultaneous spectral andbroadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment.

14 SOLAR ENERGY↗

On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions

Purpose: As traditional film is phased out in most radiotherapy centers, computed radiography (CR) systems are increasingly being purchased as a replacement. CR plates can be used for patient imaging, but may also be used for a variety of quality assurance (QA) purposes and can be calibrated in terms of dose. This study looks at their suitability for verification of intensity modulated radiation therapy (IMRT) dose distributions. Methods: A CR plate was calibrated in terms of the relative dose and the stability of response over 1 year was studied. The effect of exposing the CR plate to ambient light and of using different time delays before scanning was quantified. The CR plate was used to verify the relative dose distributions for ten IMRT patients and the results were compared to those obtained using a two dimensional (2D) diode array. Results: Exposing the CR plate to 10 s of ambient light between irradiation (174 cGy) and scanning erased approximately 80% of the signal. Changes in delay time between irradiation and scanning also affected the measurement results. The signal on the plate was found to decay at a rate of approximately 3.6 cGy/min in the first 10 min after irradiation. The use of a CR plate for IMRT patient-specific QA resulted in a significantly lower distance to agreement (DTA) and gamma pass rate than when using a 2D diode array for the measurement. This was primarily due to the over-response of the CR phosphor to low energy scattered radiation. For the IMRT QA using the CR plate, the average gamma pass rate was 97.3%. For the same IMRT QA using a diode array, the average gamma pass rate was 99.7%. The gamma criteria used were 4% dose difference and 4 mm DTA for head and neck treatments and 3% dose difference and 3 mm DTA for prostate treatments. The gamma index tolerance was 1. The lowest 10% of the dose distribution was excluded from all gamma and DTA analyses. Conclusions: Although the authors showed that CR plates can be used for patient specific IMRT QA, the practical problems such as the over-response to low energy scatter and signal fading with light exposure and time mean that alternative detectors such as radiochromic film or diode arrays will be a more sensible choice for most radiotherapy departments.

60 APPLIED LIFE SCIENCES↗

High-Efficiency CdZnTe Position-Sensitive VFG Gamma-Ray Detectors for Safeguards Applications

The goal of this project is to incorporate a Cadmium-Zinc-Telluride (CdZnTe or CZT) detector (with 1% or better resolution) into a bench-top prototype for isotope identification and related safeguards applications. The bench-top system is based on a 2x2 array of 6x6x20 mm 3 position-sensitive virtual Frisch-grid (VFG) CZT detectors. The key features of the array are that it allows for the use of average-grade CZT material with a moderate content of defects, and yet it provides high energy resolution, 1% FWHM at 662 keV, large effective area, and low-power consumption. The development of this type of 3D detector and new instruments incorporating them is motivated by the high cost and low availability of large, > 1 cm 3 , CZT crystals suitable for making multi-pixel detectors with acceptable energy resolution and efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

An Autonomous System for Grouping Events in a Developing Aftershock Sequence

We describe a prototype detection framework that automatically clusters events in real time from a rapidly unfolding aftershock sequence. We use the fact that many aftershocks are repetitive, producing similar waveforms. By clustering events based on correlation measures of waveform similarity, the number of independent event instances that must be examined in detail by analysts may be reduced. Our system processes array data and acquires waveform templates with a short-term average (STA)/long-term average (LTA) detector operating on a beam directed at the P phases of the aftershock sequence. The templates are used to create correlation-type (subspace) detectors that sweep the subsequent data stream for occurrences of the same waveform pattern. Events are clustered by association with a particular detector. Hundreds of subspace detectors can run in this framework a hundred times faster than in real time. Nonetheless, to check the growth in the number of detectors, the framework pauses periodically and reclusters detections to reduce the number of event groups. These groups define new subspace detectors that replace the older generation of detectors. Because low-magnitude occurrences of a particular signal template may be missed by the STA/LTA detector, we advocate restarting the framework from the beginning of the sequence periodically to reprocess the entire data stream with the existing detectors. We tested the framework on 10 days of data from the Nevada Seismic Array (NVAR) covering the 2003 San Simeon earthquake. One hundred eighty-four automatically generated detectors produced 676 detections resulting in a potential reduction in analyst workload of up to 73%.

58 GEOSCIENCES↗

The Octavius1500 2D ion chamber array and its associated phantoms: Dosimetric characterization of a new prototype

Purpose: The purpose of the study is to characterize the prototype of the new Octavius1500 (PTW, Freiburg, Germany) 2D ion chamber array, covering its use in different phantom setups, from the most basic solid water sandwich setup to the more complex cylindrical Octavius{sup ®} 4D (Oct4D) (PTW) phantom/detector combination. The new detector houses nearly twice the amount of ion chambers as its predecessors (Seven29 and Octavius729), thereby tackling one of the most important limitations of ion chamber (or diode) arrays, namely the limited detector density. The 0.06 cm{sup 3} cubic ion chambers are now arranged in a checkerboard pattern, leaving no lines (neither longitudinally nor laterally) without detectors. Methods: All measurements were performed on a dual energy (6 MV and 18 MV) iX Clinac (Varian Medical Systems, Palo Alto, CA) and all calculations were done in the Eclipse treatment planning system (Varian) with the Anisotropic Analytical Algorithm. First, the basic characteristics of the 2D array, such as measurement stability, dose rate dependence and dose linearity were investigated in the solid water sandwich setup. Second, the directional dependence was assessed to allow the evaluation of the new Octavius2D phantom (Oct2D{sup 1500}) for planar verification measurements of composite plans. Third, measurements were performed in the Oct4D phantom to evaluate the impact of the increased detector density on the accuracy of the volumetric dose reconstruction. Results: While showing equally good dose linearity and dose rate independence, the Octavius1500 outperforms the previous models because of its instantaneous measurement stability and its twofold active area coverage. Orthogonal field-by-field measurements immediately benefit from the increased detector density. The 3.9 cm wide compensation cavity in the new Oct2D{sup 1500} phantom prototype adequately corrects for directional dependence from the rear, resulting in good agreement within the target dose. Discrepancies may arise towards the sides of the array because of uncompensated lateral beam incidence. The beneficial impact of the detector density is most prominent in the Oct4D system, for which the average pass rate (PR) is now nearly 100% (99.31 ± 0.37) when using gamma criteria of 2%G,2 mm (10% dose threshold). In search of gamma analysis criteria that are not too lenient to detect possibly relevant deviations, the authors conclude that for our radiotherapy environment, the authors choose to adopt 3%L,3 mm PR97% (threshold 10%) criteria for the Oct2D{sup 1500}/Octavius1500 system and 2%L,3 mm PR97% (threshold 10%) for the Oct4D/Octavius1500 system. These are first line pass/check criteria and plans that fail are not necessarily rejected, but submitted to a more detailed investigation. Conclusions: When irradiated from the front, the Octavius1500 array has two main advantages over its 729 predecessors: its instantaneous measurement stability and-–most importantly—its twofold detector density. In the Oct2D1500 phantom, these advantages are counterbalanced by the more pronounced directional dependence. The measurement-based 3D dose reconstruction in the Oct4D system, however, benefits considerably from the higher detector density in the checkerboard panel design.

07 ISOTOPE AND RADIATION SOURCES↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Mu2e experiment at Fermilab: Design and status

The Mu2e experiment at Fermilab will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus. The dynamics of such charged lepton flavour violating (CLFV) process is a twobody decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates Rμe of ≤ 6 × 10 -17 (@90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → eγ decay at MEG as well as the direct searches for new physics at the LHC. Indeed, such a CLFV process probes new physics at a scale inaccessible to direct searches at either present or planned high energy colliders. Observation of a signal will be a clear evidence for new physics beyond the Standard Model. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/s) is stopped on an aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and an electromagnetic calorimeter consisting of arrays of CsI crystals. An external veto for cosmic rays is surrounding the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. Data collection is planned for the end of 2021. Lastly, an overview of the physics motivations for Mu2e, the current status of the experiment and design of the muon beam-line and the detector is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PRESAGE: Protecting Structured Address Generation against Soft Errors

Modern computer scaling trends in pursuit of larger component counts and power efficiency have, unfortunately, lead to less reliable hardware and consequently soft errors escaping into application data ("silent data corruptions"). Techniques to enhance system resilience hinge on the availability of efficient error detectors that have high detection rates, low false positive rates, and lower computational overhead. Unfortunately, efficient detectors to detect faults during address generation (to index large arrays) have not been widely researched. We present a novel lightweight compiler-driven technique called PRESAGE for detecting bit-flips affecting structured address computations. A key insight underlying PRESAGE is that any address computation scheme that flows an already incurred error is better than a scheme that corrupts one particular array access but otherwise (falsely) appears to compute perfectly. Enabling the flow of errors allows one to situate detectors at loop exit points, and helps turn silent corruptions into easily detectable error situations. Our experiments using PolyBench benchmark suite indicate that PRESAGE-based error detectors have a high error-detection rate while incurring low overheads.

Sharma, Vishal C.↗

Evaluating factors influencing infrasonic signal detection and automatic processing performance utilizing a regional network

Physical and deployment factors that influence infrasound signal detection and assess automatic detection performance for a regional infrasound network of arrays in the Western U.S. are explored using signatures of ground truth (GT) explosions (yields). Despite these repeated known sources, published infrasound event bulletins contain few GT events. Arrays are primarily distributed toward the south-southeast and south-southwest at distances between 84 and 458 km of the source with one array offering azimuthal resolution toward the northeast. Events occurred throughout the spring, summer, and fall of 2012 with the majority occurring during the summer months. Depending upon the array, automatic detection, which utilizes the adaptive F-detector successfully, identifies between 14% and 80% of the GT events, whereas a subsequent analyst review increases successful detection to 24%–90%. Combined background noise quantification, atmospheric propagation analyses, and comparison of spectral amplitudes determine the mechanisms that contribute to missed detections across the network. This analysis provides an estimate of detector performance across the network, as well as a qualitative assessment of conditions that impact infrasound monitoring capabilities. Finally, the mechanisms that lead to missed detections at individual arrays contribute to network-level estimates of detection capabilities and provide a basis for deployment decisions for regional infrasound arrays in areas of interest.

58 GEOSCIENCES↗

Two-proton Emission from {sup 29}S and {sup 17}Ne Excited States via Coulomb Excitation

The experiments of two-proton emission from {sup 29}S and {sup 17}Ne excited levels were performed at HIRFL-RIBLL facility of Institute of Modern Physics, Lanzhou. Complete kinematics measurements were achieved by the detectors of silicon strip and CsI+PIN array after the {sup 197}Au target. The preliminary results show the strong correlation of two protons according to the spectrum of correlated proton-proton energies in the laboratory reference frame.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗