Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Three-dimensional simulation of efficiency enhancement in free-electron laser with prebunched electron beam

The effect of prebunching of the electron beam and tapering of the wiggler amplitude on the harmonic upconversion in free-electron laser amplifier is studied in three dimensions. A set of coupled nonlinear first-order differential equations that describe the three-dimensional simulation of the system is solved numerically. This set of equation describes self-consistently the longitudinal spatial dependence of radiation waists, curvatures, and amplitudes together with the evaluation of the electron beam. The analysis is related to extreme ultraviolet and x-ray emission. In addition to uniform beam, prebunched electron beam has also been studied. The effect of sinusoidal distribution of entry times for the electron beam on the evolution of radiation is compared with uniform distribution. It is shown that prebunching reduces the saturation length substantially. For efficiency enhancement, the wiggler is set to decrease linearly when the radiation of the third harmonic saturates. The optimum starting point and the slope of tapering of the amplitude of the wiggler are found by a successive run of the code. It was found that tapering can increase the saturated power of the third harmonic considerably.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytic model of electron beam thermalization during the resistive Weibel instability

A novel theoretical model for underdense electron beam propagation during the nonlinear stage of the resistive Weibel instability (WI) is presented and is used to calculate the stopping time of the beam. The model and supporting simulation results lead to the conclusion that the WI initially enhances beam deceleration but then reduces it when compared to a filamentation-suppressed beam (without WI), so that the overall stopping time of the beam is essentially unaffected by the instability. Using the theoretical model, a criterion is derived that determines when deceleration is no longer enhanced by the instability. We also demonstrate that exotic plasma return current distributions can be obtained within and outside of beam filaments that sharply contrast those observed in collisionless systems. For example, the plasma return current is reversed in selected areas.

43 PARTICLE ACCELERATORS↗

Performance of a scanning pencil-beam spaceborne scatterometer for ocean wind measurements

Simulation results show that a scatterometer design using two pencil beams scanning at different incidence angles measures the near-surface oceanic winds from a satellite better under most conditions than previous designs. The return signals from the ocean surface are much stronger than those from the fan beams used previously. Performance on a polar-orbiting satellite is compared with that of a fan beam spaceborne scatterometer. A wider and continuous swath is covered. The improvement in performance is higher at low wind speeds, so it is particularly suitable for measuring the low-mean-speed tropical wind fields. Performance on a low altitude tropic-orbiting platform such as the Space Station is also shown.

Moore, R. K.↗

A three wavelength scheme to optimize hohlraum coupling on the National Ignition Facility

By using three tunable wavelengths on different cones of laser beams on the National Ignition Facility, numerical simulations show that the energy transfer between beams can be tuned to redistribute the energy within the cones of beams most prone to backscatter instabilities. These radiative hydrodynamics and laser-plasma interaction simulations have been tested against large scale hohlraum experiments with two tunable wavelengths, and reproduce the hohlraum energetics and symmetry. Using a third wavelength provides a greater level of control of the laser energy distribution and coupling in the hohlraum, and could significantly reduce stimulated Raman scattering losses and increase the hohlraum radiation drive while maintaining a good implosion symmetry.

42 ENGINEERING↗

An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle

Purpose: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. Methods: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. Results: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. Conclusions: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.

60 APPLIED LIFE SCIENCES↗

Ion-beam-driven electrostatic ion cyclotron instabilities

Results are presented of a particle simulation study of the electrostatic ion-cyclotron (EIC) instability driven by a parallel ion beam. The results of this simulation study demonstrate the nonlinear consequences of nonresonant EIC waves destabilized by an ion beam parallel to the magnetic field for the case of a large beam velocity. As a consequence of the instability, it is shown that the beam ions are heated strongly in the perpendicular direction and suffer a strong anomalous friction via EIC waves which leads to the beam slowing down. Simulation results indicate that the anomalous slowing down of beam ions by EIC waves is much larger than that from the classical electron-drag, and the perpendicular collision frequency measured from perpendicular beam heating is as large as that from Bohm diffusion. It is concluded that the ion beam driven EIC wave is a viable mechanism for the transfer of ion parallel beam energy to the ion perpendicular energy.

Okuda, H.↗

RHIC Injection Kicker Measurement and Emittance Growth Simulation

RHIC operations with gold beams at energies below the design injection energy of 10.5 GeV/N requires the injection of long bunches to mitigate the effects of IBS and space charge [1]. Bunch lengths can be up to 60 ns in length at 3.85 GeV/N (to be compared to normal 35 ns proton bunch e s at 25 GeV). Injection of such long bunches requires revisiting the details of the injection magnet pulse to insure sufficient transfer efficiency from the AGS to RHIC. This note details beam-based measurements of the deflection provided by the injection kicker magnet as a function of bunch arrival time using two different terminating resistors: a 25 Ω resistor, which has been standard for several years, and a 40 Ω resistor, which more nearly represents a matched termination. The measured deflection curves are then used as inputs into a simple simulation to estimate the effects of the kicker rise time and shape (flatness) on the transverse emittance of the injected and circulating bunches. The simulat ions indicate that there is a 12 % intrinsic vertical emittance growth associated with the standard 25 Ω kicker configuration not only for the long low energy bunches, but also for nominal 35 ns long polarized proton bunches at the nominal 25 GeV injection energy.

43 PARTICLE ACCELERATORS↗

Plasma channel localisation during multiple filamentation in air

It is shown by numerical simulations that multiple filamentation of a femtosecond laser pulse with a negative initial phase modulation in air leads to an increase in the density of self-induced laser plasma compared to the case when a transform-limited laser pulse of the same duration is used. Simultaneous control of the duration of the chirped pulse and the beam diameter results in an increase in the distance over which the first filament is formed, the length of the plasma channel, and its linear density. (nonlinear optical phenomena)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving Vibration Stability of the NSLS-II Hard X-ray Nanoprobe Beamline

The hard x-ray nanoprobe (HXN) beamline of the National Synchrotron Light Source II (NSLS-II) requires high levels of stability in order to achieve the desired instrument resolution. To ensure that the design of the endstation helps meet the stringent criteria and that natural and cultural vibration is mitigated both passively and actively, a comprehensive study complimentary to the design process has been undertaken. Vibration sources that have the potential to disrupt sensitive experiments such as wind, traffic, and NSLS II operating systems have been studied using state-of-the-art simulations and an array of field data. Further, final stage vibration isolation principles have been explored.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-17A-03: Improvement of Accuracy of Spot-Scanning Proton Beam Delivery for Liver Tumor by Real-Time Tumor-Monitoring and Gating System: A Simulation Study

Purpose: To improve the accuracy of spot-scanning proton beam delivery for target in motion, a real-time tumor-monitoring and gating system using fluoroscopy images was developed. This study investigates the efficacy of this method for treatment of liver tumors using simulation. Methods: Three-dimensional position of a fiducial marker inserted close to the tumor is calculated in real time and proton beam is gated according to the marker's distance from the planned position (Shirato, 2012). The efficient beam delivery is realized even for the irregular and sporadic motion signals, by employing the multiple-gated irradiations per operation cycle (Umezawa, 2012). For each of two breath-hold CTs (CTV=14.6cc, 63.1cc), dose distributions were calculated with internal margins corresponding to freebreathing (FB) and real-time gating (RG) with a 2-mm gating window. We applied 8 trajectories of liver tumor recorded during the treatment of RTRT in X-ray therapy and 6 initial timings. Dmax/Dmin in CTV, mean liver dose (MLD), and irradiation time to administer 3 Gy (RBE) dose were estimated assuming rigid motion of targets by using in-house simulation tools and VQA treatment planning system (Hitachi, Ltd., Tokyo). Results: Dmax/Dmin was degraded by less than 5% compared to the prescribed dose with all motion parameters for smaller CTV and less than 7% for larger CTV with one exception. Irradiation time showed only a modest increase if RG was used instead of FB; the average value over motion parameters was 113 (FB) and 138 s (RG) for smaller CTV and 120 (FB) and 207 s (RG) for larger CTV. In RG, it was within 5 min for all but one trajectory. MLD was markedly decreased by 14% and 5–6% for smaller and larger CTVs respectively, if RG was applied. Conclusions: Spot-scanning proton beam was shown to be delivered successfully to liver tumor without much lengthening of treatment time. This research was supported by the Cabinet Office, Government of Japan and the Japan Society for the Promotion of Science (JSPS) through the Funding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program), initiated by the Council for Science and Technology Policy (CSTP)

60 APPLIED LIFE SCIENCES↗

The noise power spectrum in CT with direct fan beam reconstruction

The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam CT was examined by analyzing local regions and the entire field-of-view (FOV). This was performed for cases with uniform as well as nonuniform noise across the detector cells and across views. The simulated NPS from the entire FOV and local regions showed good agreement with the analytically derived NPS. The analysis shows that whereas the NPS of a large FOV in parallel beam CT (using a ramp filter) is proportional to frequency, the NPS with direct fan beam FBP reconstruction shows a high frequency roll off. Even in small regions, the fan beam NPS can show a sharp transition (discontinuity) at high frequencies. These effects are due to the variable magnification and therefore are more pronounced as the fan angle increases. For cases with nonuniform noise, the NPS can show the directional dependence and additional effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultimate Precision on Sin^2 Theta_23 With the Numi Experiments

There were two major goals to this proposal: the study of the discrepancy between data and MC in the NuMI Medium Energy neutrino beam and the incorporation of the MINOS and NOVA neutrino oscillation datasets. The first topic was approached via development of a simulation of the NuMI beam monitoring instrumentation suite. Initially, the Horn-Off current data sets were used to measure a set of hadron production parameters which improved the data/MC agreement in a way which was independent of the focusing parameters. The peak position discrepancy was only explained by a large (10kA) reduction in the horn current. A full simulation of the muon monitors was developed to attempt to make an independent measurement of the horn current by means of differential data taken by those monitors. While only at the 5kA level, the result corroborated the former findings. The second goal has not yet been completed but progress has focused on understanding how to modify the MINOS MC to take into account the MEC contribution which is missing from the underlying NEUGEN MC. A number of improvements to the MINOS reconstruction have been necessary. The framework to run the fits on the combined data has been completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Charge, Multi-MeV Electron Bunches Accelerated in Moderate Laser-Plasma Interaction Regime

Experiments, and simulations have shown that quasi-monoenergetic electron bunches can be accelerated from the background electron plasma population up to relativistic energies. Theoretical work indicated that with a proper choice of laser, plasma, and injection parameters the acceleration of electron bunches with small energy spread and short bunch length can occur in moderate intensity regime. Here we present the results of an experiment on electron acceleration carried out at the IPCF-CNR's Intense Laser Irradiation Laboratory in Pisa, within a wide national collaboration leaded by INFN named PLASMONX. High-charge, multi-MeV electron bunches were accelerated in moderated intensity regime by focusing the laser beam on a laminar gaseous target produced by a supersonic gas-jet. The laser-gas interaction was studied via interferometry, and Thomson scattering while the electron bunches were detected and characterised using a phosphor screen coupled with a magnetic spectrometer or a dosimetric detector. In some cases highly collimated electron bunches with moderate energy spread were observed, while the generation of high-charge, MeV energies electron bunches were obtained with high reproducibility for each gases tested.

43 PARTICLE ACCELERATORS↗

Direct simulation Monte Carlo study of effects of thermal nonuniformities in electron-beam physical vapor deposition

In a typical electron-beam physical vapor deposition system, there is limited control over how the high-power electron beam heats the metal surface. This leads to thermal nonuniformities at the melt. Three-dimensional direct simulation Monte Carlo simulations were performed with the aim of quantifying the effect of such spatial variations of source temperature in thin film depositions using an electron-beam physical vapor deposition system. The source temperature distribution from a typical deposition process was used in the direct simulation Monte Carlo simulations performed for various mass flow rates. The use of an area-averaged temperature is insufficient for all mass flow rates due to the highly nonlinear relationship between temperature and saturation number density, and hence, the mass flux. The mass flow rate equivalent temperature was determined, and the simulations performed with this temperature were compared with those corresponding to the actual nonuniform temperature distribution. For low mass flow rates, the growth rates depend very weakly on the spatial variation of temperature as long as an equivalent temperature corresponding to the same mass flow rate was used. However, as the mass flow rate increases, the error associated with this approximation increases. For deposition processes with source Knudsen numbers less than 0.05, it is not possible to account for the spatial nonuniformities in temperature using the total mass flow rate without significant errors. For a given mass flow rate, the errors associated with using an equivalent temperature decrease with increasing collector plane distance since the flow is allowed to expand further, thereby decreasing the effects of slit temperature nonuniformities.

36 MATERIALS SCIENCE↗

Photon energy-modulated radiotherapy: Monte Carlo simulation and treatment planning study

Purpose: To demonstrate the feasibility of photon energy-modulated radiotherapy during beam-on time. Methods: A cylindrical device made of aluminum was conceptually proposed as an energy modulator. The frame of the device was connected with 20 tubes through which mercury could be injected or drained to adjust the thickness of mercury along the beam axis. In Monte Carlo (MC) simulations, a flattening filter of 6 or 10 MV linac was replaced with the device. The thickness of mercury inside the device varied from 0 to 40 mm at the field sizes of 5 x 5 cm{sup 2} (FS5), 10 x 10 cm{sup 2} (FS10), and 20 x 20 cm{sup 2} (FS20). At least 5 billion histories were followed for each simulation to create phase space files at 100 cm source to surface distance (SSD). In-water beam data were acquired by additional MC simulations using the above phase space files. A treatment planning system (TPS) was commissioned to generate a virtual machine using the MC-generated beam data. Intensity modulated radiation therapy (IMRT) plans for six clinical cases were generated using conventional 6 MV, 6 MV flattening filter free, and energy-modulated photon beams of the virtual machine. Results: As increasing the thickness of mercury, Percentage depth doses (PDD) of modulated 6 and 10 MV after the depth of dose maximum were continuously increased. The amount of PDD increase at the depth of 10 and 20 cm for modulated 6 MV was 4.8% and 5.2% at FS5, 3.9% and 5.0% at FS10 and 3.2%-4.9% at FS20 as increasing the thickness of mercury from 0 to 20 mm. The same for modulated 10 MV was 4.5% and 5.0% at FS5, 3.8% and 4.7% at FS10 and 4.1% and 4.8% at FS20 as increasing the thickness of mercury from 0 to 25 mm. The outputs of modulated 6 MV with 20 mm mercury and of modulated 10 MV with 25 mm mercury were reduced into 30%, and 56% of conventional linac, respectively. The energy-modulated IMRT plans had less integral doses than 6 MV IMRT or 6 MV flattening filter free plans for tumors located in the periphery while maintaining the similar quality of target coverage, homogeneity, and conformity. Conclusions: The MC study for the designed energy modulator demonstrated the feasibility of energy-modulated photon beams available during beam-on time. The planning study showed an advantage of energy-and intensity modulated radiotherapy in terms of integral dose without sacrificing any quality of IMRT plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-127: Dosimetric Evaluation Microbeam Treatment Method Using Monoenergetic Photon Î1/4-Beams

Purpose: One of the external radiotherapy techniques with potential to greatly enhance the therapeutic ratio is Microbeam Radiotherapy (MRT). A recent approach to MRT delivers discrete finely spaced μ-beams. The technique is based on two principles: a] there is almost no dose between the dose peaks of two neighboring μ-beams and b] it is not needed for the whole target to be irradiated to achieve tumor control. Preliminary results have shown the ability to increase tumor control without increasing normal tissue complication probability with this technique. The purpose of this study was to dosimetrically evaluate the clinical feasibility of the above concept, taking into consideration factors as beam energy, size, and separation, and tumor depth. Methods: A Monte Carlo (MC) model was used to simulate different configurations of μ-beams. A total of 420 different μ-beams were evaluated for beam sizes, energies, depths and distances between the beams. The different MC beam penetration results were compared vs. simulations, which were conducted at the existing Small animal irradiator (SARRP) facility at our department. Results: Separation between the peak doses of the μ-beams was well maintained in all simulations. This shows that the scatter can be ignored even for cases where the distance from the center of the μ-beams was set to 200 μm (E = 100 keV) and for depths as great as 5 cm. Monoenergetic 100 keV μ-beam energies were ∼25% more penetrative than a 220 kVp SARRP beam at the depth of 8 cm. The effect is more profound as the energy increases. Conclusion: Dosimetric evaluation of this MRT method showed it could feasibly be used to treat tumors at clinically relevant depths. MC results showed that the scatter between the beams remains minimal even for depths of 5 cm and separation of the beams of 200 μm.

60 APPLIED LIFE SCIENCES↗

Fast Advection of Magnetic Fields by Hot Electrons

Experiments where a laser-generated proton beam is used to probe the megagauss strength self-generated magnetic fields from a nanosecond laser interaction with an aluminum target are presented. At intensities of 10{sup 15} W cm{sup -2} and under conditions of significant fast electron production and strong heat fluxes, the electron mean-free-path is long compared with the temperature gradient scale length and hence nonlocal transport is important for the dynamics of the magnetic field in the plasma. The hot electron flux transports self-generated magnetic fields away from the focal region through the Nernst effect [A. Nishiguchi et al., Phys. Rev. Lett. 53, 262 (1984)] at significantly higher velocities than the fluid velocity. Two-dimensional implicit Vlasov-Fokker-Planck modeling shows that the Nernst effect allows advection and self-generation transports magnetic fields at significantly faster than the ion fluid velocity, v{sub N}/c{sub s{approx_equal}}10.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5 - 2 times higher than in systems equipped with a 'nondescanned' detector. (application of lasers and laser-optical methods in life sciences)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗