Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

ULTRAVIOLET OBSERVATIONS OF THE GLOBULAR CLUSTER M10 FROM HST AND GALEX: THE BSS POPULATION

We present a combination of high-resolution Hubble Space Telescope and wide-field ground-based and Galaxy Evolution Explorer data of the Galactic globular cluster M10 (NGC 6254). By using this large data set, we determined the center of gravity of the cluster and we built its density profile from star counts over its entire radial extension. We find that the density profile is well reproduced by a single-mass King model with structural parameters c = 1.41 and r{sub c} = 41''. We also studied the blue straggler star (BSS) population and its radial distribution. We count a total number of 120 BSS within the tidal radius. Their radial distribution is bimodal: highly peaked in the cluster center, decreasing at intermediate distances, and rising again outward. We discuss these results in the context of the dynamical clock scheme presented by Ferraro et al. and of recent results about the radial distribution of binary systems in this cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Small animal simultaneous PET/MRI: initial experiences in a 9.4T microMRI

We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-pion-exchange and other higher-order contributions to the pp{yields}pp{pi}{sup 0} reaction

Much effort has been invested on effective-field-theoretical studies of the near-threshold NN{yields}NN{pi} reactions and, in order to deal with the somewhat large three-momentum transfers involved, the momentum counting scheme (MCS) was proposed as an alternative to the usual Weinberg counting scheme. Given the fact that a quantitative explanation of the existing high-precision NN{yields}NN{pi} data requires a careful examination of higher chiral order contributions to the transition operator, we make a detailed numerical investigation of the convergence property of MCS for a pilot case of the pp{yields}pp{pi}{sup 0} reaction. Our study indicates that MCS is superior to the Weinberg scheme in identifying dominant higher order contributions to the NN{yields}NN{pi} reactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate U 238 ( n , 2 n ) U 237 reaction cross-section measurements from 6.5 to 14.8 MeV

In this study, the cross section for the 238 U(n,2n) 237 U reaction has been measured in the incident neutron energy range from 6.5 to 14.8 MeV in small energy steps using an activation technique. Monoenergetic neutron beams were produced via the 2 H( d,n ) 3 He and 3 H ( d,n ) 4 He reactions. 238 U targets were activated along with Au and Al monitor foils to determine the incident neutron flux. The activity of the reaction products was measured in TUNL's low-background counting facility using high-resolution γ-ray spectroscopy. The results are compared with previous measurements and latest data evaluations. Statistical-model calculations, based on the Hauser-Feshbach formalism, have been carried out using the CoH 3 code and are compared with the experimental results. Finally, the present self-consistent and high-quality data are important for stockpile stewardship and nuclear forensic purposes as well as for the design and operation of fast reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linear diffraction grating interferometer with high alignment tolerance and high accuracy

We present an innovative structure of a linear diffraction grating interferometer as a long stroke and nanometer resolution displacement sensor for any linear stage. The principle of this diffractive interferometer is based on the phase information encoded by the {+-}1st order beams diffracted by a holographic grating. Properly interfering these two beams leads to modulation similar to a Doppler frequency shift that can be translated to displacement measurements via phase decoding. A self-compensation structure is developed to improve the alignment tolerance. LightTool analysis shows that this new structure is completely immune to alignment errors of offset, standoff, yaw, and roll. The tolerance of the pitch is also acceptable for most installation conditions. In order to compact the structure and improve the signal quality, a new optical bonding technology by mechanical fixture is presented so that the miniature optics can be permanently bonded together without an air gap in between. For the output waveform signals, a software module is developed for fast real-time pulse counting and phase subdivision. A laser interferometer HP5529A is employed to test the repeatability of the whole system. Experimental data show that within 15 mm travel length, the repeatability is within 15 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring SNM Isotopic Distributions using FRAM

The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240 Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biomarkers of Radiosensitivity in A-Bomb Survivors Pregnant at the Time of Bombings in Hiroshima and Nagasaki

Purpose . There is evidence in the literature of increased maternal radiosensitivity during pregnancy. Materials and Methods . We tested this hypothesis using information from the atomic-bomb survivor cohort, that is, the Adult Health Study database at the Radiation Effects Research Foundation, which contains data from a cohort of women who were pregnant at the time of the bombings of Hiroshima and Nagasaki. Previous evaluation has demonstrated long-term radiation dose-response effects. Results/Conclusions . Data on approximately 250 women were available to assess dose-response rates for serum cholesterol, white blood cell count, erythrocyte sedimentation rate, and serum hemoglobin, and on approximately 85 women for stable chromosome aberrations, glycophorin A locus mutations, and naïve CD4 T-cell counts. Although there is no statistically significant evidence of increased radiosensitivity in pregnant women, the increased slope of the linear trend line in the third trimester with respect to stable chromosome aberrations is suggestive of an increased radiosensitivity.

Miles, Edward F.↗

Energetic electrons in the Jovian magnetosphere

Results are reported for a detailed analysis of Pioneer 10 data on energetic particle species in the magnetodisk region of Jupiter's magnetosphere. It is shown that the observed counting rates in the magnetodisk (beyond 20 Jupiter radii) were caused primarily by electrons with energies exceeding 0.06 MeV. Absolute omnidirectional electron intensities in the magnetodisk are presented for five integral energy ranges, and a model electron differential energy spectrum is found to fit the intensities throughout most of the encounter trajectory. It is suggested that the observed spectral shape results from losses of high-energy electrons by pitch-angle scattering. Observed equatorial energy spectra are used to compute distribution functions for several values of the first adiabatic invariant, mu. The radial profiles of the functions are found to have maxima at about 50 Jupiter radii inbound as well as at about 90 radii outbound and to diminish strongly for lesser radii. The large decreases in density are shown to require strong losses, and resonant electron whistler-mode pitch-angle scattering is suggested as a loss mechanism.

Baker, D. N.↗

An analysis of new techniqes for radiometric correction of LANDSAT-4 Thematic Mapper images

The utility of methods for generating TM RLUTS which can improve the quality of the resultant images was investigated. The TM-CCT-ADDS tape was changed to account for a different collection window for the calibration data. Several scenes of Terrebonne Bay, Louisiana and the Grand Bahamas were analyzed to evaluate the radiometric corrections operationally applied to the image data and to investigate several techniques for reducing striping in the images. Printer plots for the TM shutter data were produced and detector statistics were compiled and plotted. These statistics included various combinations of the average shutter counts for each scan before and after DC restore for forward and reverse scans. Results show that striping is caused by the detectors becoming saturated when they view a bright cloud and depress the DC restore level.

Kogut, J.↗

Calibration of photon counting imaging microchannel plate detectors for EUV astronomy

The calibration of photon counting imaging detectors for satellite based EUV astronomy is a complex process designed to ensure the validity of the data received 'in orbit'. The methods developed to accomplish calibration of microchannel plate detectors for the Extreme Ultraviolet Explorer are described and illustrated. The characterization of these detectors can be subdivided into three categories: stabilization, performance tests, and environmental tests.

Siegmund, O. H. W.↗

Measuring Airflow With Digital Holographic Interferometry

Digital image-processing system assists in analysis of holographic interferometric images of flow about airfoil. Operating semiautomatically, identifies, counts, and labels interference fringes, then processes distances between fringes into distribution of pressure on surface of airfoil. Yields data on pressure faster than manual image-analyses techniques, and data compares favorably with those obtained by manual analysis and by probe measurements of pressure. Uses computer programs evaluating interferograms along straight or curved lines represented by polygon segments. User prompted for such inputs as reference points and fringe number. Digitizes holographic interferograms of flow and processes them into data of pressure or other properties of flow.

Torres, Francisco J.↗

Geologic Evolution of the Martian Highlands: MTMs -20002, -20007, -25002, and -25007

As part of a continuing study to understand the relationship between valleys and highland resurfacing through geologic mapping, the authors are continuing to map seven 1:500,000-scale MTM quads in portions of the Margaritifer, Arabia, and Noachis Terrae. Results from this mapping will also help constrain the role and extent of past water in the region. The MTMs are grouped in two different areas within the region and compliment previous mapping in adjacent areas. Three western quads focus on Jones crater and the Himera, Samara, and Loire Valles systems. This abstract focuses on the four eastern quads wherein a large, ancient impact structure, Noachis basin, is flanked on its south and east by a series of valley networks. A solitary valley drains this basin and stretches north-northeast for approximately 450 km, transporting materials into Arabia Terra. Pertinent raster and vector data have been imported and registered using ESRI's ArcMap GIS software. To inspect and quantify stratigraphic relations, crater counts are being compiled in ESRI's ArcView GIS software to make use of crater counting tools specifically developed for planetary mappers. New datasets from the Mars Reconnaissance Orbiter including 4 CTX images, 31 CRISM multi-spectral pushbroom images, and 4 HiRISE images were incorporated into the project during the third year. The CRISM dataset uses summary parameters with thresholds to select targets for the high-resolution datasets. The befit for mappers is the extensive coverage and general compositional information. Results of a cursory analysis show strong mafic absorptions on the floors of Peta crater and Noachis basin. LCP absorptions occur more often than olivine, however, olivine tends to be denser than both pyroxenes. Olivine and HCP mat indicate relatively younger rocks, which is supported by the occurrence of wrinkle ridges associated with high olivine and HCP absorptions in the Peta crater and Noachis basin floors.

Fortezzo, C. M.↗

A Microbial Analysis of Space-Grown Produce

Before space crops become a permanent staple of the astronaut diet, we must first understand how plants and pathogenic microbes interact in microgravity. Crops such as red romaine lettuce and Chinese cabbage were grown on the International Space Station and sent back to Kennedy Space Center for microbial analysis. Aerobic plate counts and metagenomic sequencing were used to characterize bacterial and fungal communities for plants and their respective ''pillows''. These data will be used to create new guidelines for the microbial safety of space-grown produce, and will help us better protect astronauts from food-borne pathogens like E.coli, Staphylococcus, and Salmonella.

Barash, Eric L.↗

ENSO and MJO Modulation of U.S. Cloud-to-Ground Lightning Activity

Cloud-to-ground (CG) lightning substantially impacts human health and property. However, the relations between U.S. lightning activity and the Madden-Julian Oscillation (MJO) and El Niño-Southern Oscillation (ENSO), two predictable drivers of global climate variability, remain uncertain, in part because most lightning datasets have short records that cannot robustly reveal MJO- and ENSO-related patterns. To overcome this limitation, we developed an empirical model of 6-hourly lightning flash count over the contiguous U.S. (CONUS) using environmental variables (convective available potential energy and precipitation) andNational Lightning Detection Network data for 2003–2016. This model is shown to reproduce the observed daily and seasonal variability of lightning over most of CONUS. Then, the empirical model was applied to construct a proxy lightning dataset for the period 1979–2021, which was used to investigate the summer MJO-lightning relationship at daily resolution and the winter-spring ENSO-lightning relationship at seasonal resolution. Overall, no robust relationship between MJO phase and lightning patterns was found when seasonality was taken into consideration. El Niño is associated with increased lightning activity over the Coastal Southeast U.S. during early winter, the Southwest during winter through spring, and the Northwest during late spring, whereas La Niña is associated with increased lightning activity over the Tennessee River Valley during winter.

Lightning↗

Measurements of Gas Bubble Size Distributions in Flowing Liquid Mercury

ABSTRACT Pressure waves created in liquid mercury pulsed spallation targets have been shown to induce cavitation damage on the target container. One way to mitigate such damage would be to absorb the pressure pulse energy into a dispersed population of small bubbles, however, measuring such a population in mercury is difficult since it is opaque and the mercury is involved in a turbulent flow. Ultrasonic measurements have been attempted on these types of flows, but the flow noise can interfere with the measurement, and the results are unverifiable and often unrealistic. Recently, a flow loop was built and operated at Oak Ridge National Labarotory to assess the capability of various bubbler designs to deliver an adequate population of bubbles to mitigate cavitation damage. The invented diagnostic technique involves flowing the mercury with entrained gas bubbles in a steady state through a horizontal piping section with a glass-window observation port located on the top. The mercury flow is then suddenly stopped and the bubbles are allowed to settle on the glass due to buoyancy. Using a bright-field illumination and a high-speed camera, the arriving bubbles are detected and counted, and then the images can be processed to determine the bubble populations. After using this technique to collect data on each bubbler, bubble size distributions were built for the purpose of quantifying bubbler performance, allowing the selection of the best bubbler options. This paper presents the novel procedure, photographic technique, sample visual results and some example bubble size distributions. The best bubbler options were subsequently used in proton beam irradiation tests performed at the Los Alamos National Laboratory. The cavitation damage results from the irradiated test plates in contact with the mercury are available for correlation with the bubble populations. The most effective mitigating population can now be designed into prototypical geometries for implementation into an actual SNS target.

99 GENERAL AND MISCELLANEOUS↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPECTRAL RELATIVE ABSORPTION DIFFERENCE METHOD

When analyzing field data, the uncertainty in the background continuum emission produces the majority of error in the final gamma-source analysis. The background emission typically dominates an observed spectrum in terms of counts and is highly variable spatially and temporally. The majority of the spectral shape of the background continuum is produced by combinations of cosmic rays, {sup 40}K, {sup 235}U, and {sup 220}Rn, and the continuum is similar in shape to the 15%-20% level for most field observations. However, the goal of spectroscopy analysis is to pick up subtle peaks (<%5) upon this large background. Because the continuum is falling off as energy increases, peak detection algorithms must first define the background surrounding the peak. This definition is difficult when the range of background shapes is considered. The full spectral template matching algorithms are heavily weighted to solving for the background continuum as it produces significant counts over much of the energy range. The most appropriate background mitigation technique is to take a separate background observation without the source of interest. But, it is frequently not possible to record a background observation in the exact location before (or after) a source has been detected. Thus, one uses approximate backgrounds that rely on spatially nearby locations or similar environments. Since the error in many field observations is dominated by the background, a technique that is less sensitive to the background would be quite beneficial. We report the result of an initial investigation into a novel observation scheme for gamma-emission detection in high background environments. Employing low resolution, NaI, detectors, we examine the different between the direct emission and the 'spectral-shadow' that the gamma emission produces when passed through a thin absorber. For this detection scheme to be competitive, it is required to count and analyze individual gamma-events. We describe the unique instrumental setup which we assembled to make these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗