Search NASA⌕ Search

SEARCH · Search NASA

Results for “error rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Achieving unequal error protection with convolutional codes

This paper examines the unequal error protection capabilities of convolutional codes. Both time-invariant and periodically time-varying convolutional encoders are examined. The effective free distance vector is defined and is shown to be useful in determining the unequal error protection (UEP) capabilities of convolutional codes. A modified transfer function is used to determine an upper bound on the bit error probabilities for individual input bit positions in a convolutional encoder. The bound is heavily dependent on the individual effective free distance of the input bit position. A bound relating two individual effective free distances is presented. The bound is a useful tool in determining the maximum possible disparity in individual effective free distances of encoders of specified rate and memory distribution. The unequal error protection capabilities of convolutional encoders of several rates and memory distributions are determined and discussed.

Mills, D. G.↗

Numerical Validation of an Algorithm for Combined Soiling and Degradation Analysis of Photovoltaic Systems

We describe and demonstrate an open-source algorithm for simultaneously quantifying degradation and soiling of photovoltaic (PV) systems from energy-production time series data. The new analysis is based on year-on-year degradation rate analysis combined with stochastic rate and recovery soiling analysis. The algorithm is designed to fit into the workflow provided by RdTools, a Python module maintained by NREL and collaboratively developed with the community, which provides a framework and functions for degradation and loss-factor analysis of PV field data. We demonstrate the method on numerically simulated PV data sets and show that it reduces the root-mean-square error of the P50 degradation rate estimate when soiling is present.

14 SOLAR ENERGY↗

Development and evaluation of virtual refrigerant mass flow sensors for fault detection and diagnostics

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressor that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor is not delivering the expected flow due to a leaky suction or discharge valve or other internal fault, the energy-balance or EEV model can provide accurate flow estimates. In this paper, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics.

Kim, Woohyun↗

Local position control: A new concept for control of manipulators

Resolved motion rate control is currently one of the most frequently used methods of manipulator control. It is currently used in the Space Shuttle remote manipulator system (RMS) and in prosthetic devices. Position control is predominately used in locating the end-effector of an industrial manipulator along a path with prescribed timing. In industrial applications, resolved motion rate control is inappropriate since position error accumulates. This is due to velocity being the control variable. In some applications this property is an advantage rather than a disadvantage. It may be more important for motion to end as soon as the input command is removed rather than reduce the position error to zero. Local position control is a new concept for manipulator control which retains the important properties of resolved motion rate control, but reduces the drift. Local position control can be considered to be a generalization of resolved position and resolved rate control. It places both control schemes on a common mathematical basis.

Kelly, Frederick A.↗

Resilience Design Patterns - A Structured Approach to Resilience at Extreme Scale (version 1.0)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest that very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Practical limits on power consumption in HPC systems will require future systems to embrace innovative architectures, increasing the levels of hardware and software complexities. The resilience challenge for extreme-scale HPC systems requires management of various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. These techniques must seek to improve resilience at reasonable overheads to power consumption and performance. While the HPC community has developed various solutions, application-level as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods and metrics to investigate and evaluate resilience holistically in HPC systems that consider impact scope, handling coverage, and performance & power eciency across the system stack. Additionally, few of the current approaches are portable to newer architectures and software ecosystems, which are expected to be deployed on future systems. In this document, we develop a structured approach to the management of HPC resilience based on the concept of resilience-based design patterns. A design pattern is a general repeatable solution to a commonly occurring problem. We identify the commonly occurring problems and solutions used to deal with faults, errors and failures in HPC systems. The catalog of resilience design patterns provides designers with reusable design elements. We define a design framework that enhances our understanding of the important constraints and opportunities for solutions deployed at various layers of the system stack. The framework may be used to establish mechanisms and interfaces to coordinate flexible fault management across hardware and software components. The framework also enables optimization of the cost-benefit trade-os among performance, resilience, and power consumption. The overall goal of this work is to enable a systematic methodology for the design and evaluation of resilience technologies in extreme-scale HPC systems that keep scientific applications running to a correct solution in a timely and cost-ecient manner in spite of frequent faults, errors, and failures of various types.

97 MATHEMATICS AND COMPUTING↗

Pseudospectral calculation of the wave function of helium and the negative hydrogen ion

We study the numerical solution of the nonrelativistic Schroedinger equation for two-electron atoms in ground and excited S states using pseudospectral (PS) methods of calculation. The calculation achieves convergence rates for the energy, Cauchy error in the wave function, and variance in local energy that are exponentially fast for all practical purposes. The method requires three separate subdomains to handle the wave function's cusplike behavior near the two-particle coalescences. The use of three subdomains is essential to maintaining exponential convergence and is more computationally efficient than a single subdomain. A comparison of several different treatments of the cusps suggests that the simplest prescription is sufficient. We investigate two alternate methods for handling the semi-infinite domain, one which involves a sequence of truncated versions of the domain and the other which employs an algebraic mapping of the semi-infinite domain to a finite one and imposes no explicit cutoffs on the wave function. The latter prescription proves superior. For many purposes it proves unnecessary to handle the three-particle coalescence in a special way. The presence of logarithmic terms in the exact solution is expected to limit the convergence to being nonexponential but the only clear evidence of that is the rate of convergence of derivatives near the three-particle coalescence point. Higher resolution than achieved in this work will ultimately be needed to see its limiting effect on other measures of error. As developed and applied here the PS method has many virtues: no explicit assumptions need be made about the asymptotic behavior of the wave function near cusps or at large distances, the local energy (H{psi}/{psi}) is exactly equal to the calculated global energy at all collocation points, local errors go down everywhere with increasing resolution, the effective basis using Chebyshev polynomials is complete and simple, and the method is easily extensible to other bound states. As the number of collocation points grows, the method achieves exponential convergence up to the resolution tested. This study serves as a proof-of-principle of the method for more general two- and possibly three-electron applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Some Observations about the Nearest-Neighbor Model of the Error Threshold

I explore some aspects of the 'error threshold' - a critical mutation rate above which a population is nonviable. The phase transition that occurs as mutation rate crosses this threshold has been shown to be mathematically equivalent to the loss of ferromagnetism that occurs as temperature exceeds the Curie point. I will describe some refinements and new results based on the simplest of these mutation models, will discuss the commonly unperceived robustness of this simple model, and I will show some preliminary results comparing qualitative predictions with simulations of finite populations adapting at high mutation rates. I will talk about how these qualitative predictions are relevant to biomedical science and will discuss how my colleagues and I are looking for phase-transition signatures in real populations of Escherichia coli that go extinct as a result of excessive mutation.

60 APPLIED LIFE SCIENCES↗

On the use of Lineal Energy Measurements to Estimate Linear Energy Transfer Spectra

This paper examines the error resulting from using a lineal energy spectrum to represent a linear energy transfer spectrum for applications in the space radiation environment. Lineal energy and linear energy transfer spectra are compared in three diverse but typical space radiation environments. Different detector geometries are also studied to determine how they affect the error. LET spectra are typically used to compute dose equivalent for radiation hazard estimation and single event effect rates to estimate radiation effects on electronics. The errors in the estimations of dose equivalent and single event rates that result from substituting lineal energy spectra for linear energy spectra are examined. It is found that this substitution has little effect on dose equivalent estimates in interplanetary quiet-time environment regardless of detector shape. The substitution has more of an effect when the environment is dominated by solar energetic particles or trapped radiation, but even then the errors are minor especially if a spherical detector is used. For single event estimation, the effect of the substitution can be large if the threshold for the single event effect is near where the linear energy spectrum drops suddenly. It is judged that single event rate estimates made from lineal energy spectra are unreliable and the use of lineal energy spectra for single event rate estimation should be avoided.

Adams, David A.↗

The Effects of Rainfall Inhomogeneity on Climate Variability of Rainfall Estimated from Passive Microwave Sensors

Passive microwave rainfall estimates that exploit the emission signal of raindrops in the atmosphere are sensitive to the inhomogeneity of rainfall within the satellite field of view (FOV). In particular, the concave nature of the brightness temperature (T(sub b)) versus rainfall relations at frequencies capable of detecting the blackbody emission of raindrops cause retrieval algorithms to systematically underestimate precipitation unless the rainfall is homogeneous within a radiometer FOV, or the inhomogeneity is accounted for explicitly. This problem has a long history in the passive microwave community and has been termed the beam-filling error. While not a true error, correcting for it requires a priori knowledge about the actual distribution of the rainfall within the satellite FOV, or at least a statistical representation of this inhomogeneity. This study first examines the magnitude of this beam-filling correction when slant-path radiative transfer calculations are used to account for the oblique incidence of current radiometers. Because of the horizontal averaging that occurs away from the nadir direction, the beam-filling error is found to be only a fraction of what has been reported previously in the literature based upon plane-parallel calculations. For a FOV representative of the 19-GHz radiometer channel (18 km X 28 km) aboard the Tropical Rainfall Measuring Mission (TRMM), the mean beam-filling correction computed in this study for tropical atmospheres is 1.26 instead of 1.52 computed from plane-parallel techniques. The slant-path solution is also less sensitive to finescale rainfall inhomogeneity and is, thus, able to make use of 4-km radar data from the TRMM Precipitation Radar (PR) in order to map regional and seasonal distributions of observed rainfall inhomogeneity in the Tropics. The data are examined to assess the expected errors introduced into climate rainfall records by unresolved changes in rainfall inhomogeneity. Results show that global mean monthly errors introduced by not explicitly accounting for rainfall inhomogeneity do not exceed 0.5% if the beam-filling error is allowed to be a function of rainfall rate and freezing level and does not exceed 2% if a universal beam-filling correction is applied that depends only upon the freezing level. Monthly regional errors can be significantly larger. Over the Indian Ocean, errors as large as 8% were found if the beam-filling correction is allowed to vary with rainfall rate and freezing level while errors of 15% were found if a universal correction is used.

Kummerow, Christian↗

Fiber optic rotation sensor /FORS/ signal detection and processing

The recent development of low-loss single-mode optical fiber waveguides for light has made possible a new class of inertial reference devices built on the principle of a closed loop interferometer. Light circulating through the loop in both directions experiences a relative phase delay proportional to rotation rate about the loop axis. This paper derives the phase delay and discusses signal detection, signal processing techniques and error sources. It is concluded that synchronous modulation and demodulation and an active gain control at the signal calculation level are required to eliminate drift errors. Potential performance is extraordinarily good; rotation rate sensitivity of a few milli-arc seconds per second and angular position random walk errors of an arc second per square root hour appear feasible.

Goss, W. C.↗

Collagen Turnover in Relation to Risk Factors and Hemodynamics in Human Intracranial Aneurysms

Determinants for molecular and structural instability, that is, impending growth or rupture, of intracranial aneurysms (IAs) remain uncertain. To elucidate this, we endeavored to estimate the actual turnover rates of the main molecular constituent in human IA (collagen) on the basis of radiocarbon ( 14 C) birth dating in relation to IA hemodynamics. Collagen turnover rates in excised human IA samples were calculated using mathematical modeling of 14 C birth dating data of collagen in relation to risk factors and histological markers for collagen maturity/turnover in selected IA. Hemodynamics were simulated using image-based computational fluid dynamics. Correlation, logistic regression, and receiver operating characteristic analyses were performed. Collagen turnover rates were estimated in 46 IA (43 patients); computational fluid dynamics could be performed in 20 IA (20 patients). The mean collagen turnover rate (γ) constituted 126% (±1% error) per year. For patients with arterial hypertension, γ was greater than 2600% annually, whereas γ was distinctly lower with 32% (±1% error) per year for patients without risk factors, such as smoking and hypertension. There was a distinct association between histological presence of rather immature collagen in human IA and the presence of modifiable risk factors. Spatial-temporal averaged wall shear stress predicted rapid collagen turnover (odds ratio, 1.6 [95% CI, 1.0–2.7]). Receiver operating characteristic analysis demonstrated a good test accuracy (area under the curve, 0.798 [95% CI, 0.598–0.998]) for average wall shear stress with a threshold ≥4.9 Pa for rapid collagen turnover. Our data indicate that turnover rates and stability of collagen in human IA are strongly associated with the presence of modifiable risk factors and aneurysmal hemodynamics. Finally, these findings underline the importance of strict risk factor modification in patients with unruptured IA. Future should include more detailed risk factor data to establish a more causal understanding of hemodynamics and the rupture risk of individual IA.

60 APPLIED LIFE SCIENCES↗

Severity of liver disease affects HCV kinetics in patients treated with intravenous silibinin monotherapy

HCV kinetic analysis and modeling during antiviral therapy have not been performed in decompensated cirrhotic patients awaiting liver transplantation. Here, viral and host parameters were compared in patients treated with daily intravenous silibinin (SIL) monotherapy for 7 days according to the severity of their liver disease. Data were obtained from 25 patients, 12 non-cirrhotic, 8 with compensated cirrhosis and 5 with decompensated cirrhosis. The standard-biphasic model with time-varying SIL effectiveness (from 0 to ε max ) was fit to viral kinetic data. Our results show that baseline viral load and age were significantly associated with the severity of liver disease (p<0.0001). A biphasic viral decline was observed in most patients with a higher first phase decline patients with less severe liver disease. The maximal effectiveness, ε max , was significantly (p≤0.032) associated with increasing severity of liver disease (ε max [s.e.]=0.86[0.05], ε max =0.69[0.06] and ε max =0.59[0.1]). The 2nd phase decline slope was not significantly different among groups (mean 1.88±0.15 log 10 IU/ml/wk, p=0.75) as was the rate of change of SIL effectiveness (k=2.12/day[standard error, SE=0.18/day]). HCV-infected cell loss rate (δ[SE]=0.62/day[0.05/day]) was high and similar among groups. We conclude that the high loss rate of HCV-infected cells suggests that sufficient dose and duration of SIL might achieve viral suppression in advanced liver disease.

59 BASIC BIOLOGICAL SCIENCES↗

Techniques of PIV in stratified two-phase headers

The stratification of two fluid phases, namely gas and liquid, within flow distribution devices, such as headers, that have side or bottom oriented fluid pipe connections, or discharges, has shown relevance to loss-of-coolant accidents in nuclear power plants. Under critical conditions the gas phase could entrain into the predominantly liquid discharge flow causing the fluid quality to be dramatically affected. This condition is referred to as the onset of gas entrainment (OGE) phenomenon and it occurs at a specific critical liquid height which changes with the Froude number. The liquid velocity field at the OGE is of importance, for example, to theorists who may find a semi-empirical approach to model this phenomenon. Stereoscopic particle image velocimetry (PIV) technique is an excellent candidate for non-intrusively investigating the velocity field. The liquid-phase velocity field was investigated for three discharge Froude numbers at the OGE. It was found that the stereoscopic PIV could be used to extract the velocity field experimentally, yet a high degree of error was found in the region closest to the discharge. The relative error was determined through conservation of mass by comparing the flow rate obtained with the PIV data to that obtained using a flow meter. In summary it was found that the number of image planes used, the resolution of the image planes, and consequently the number of vectors used to calculate the flow rate, all contributed a great deal to the relative error. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

Feasibility Study of Two Candidate Reaction Wheel/thruster Hybrid Control Architecture Designs for the Cassini Spacecraft

As the first spacecraft to achieve orbit at Saturn in 2004, Cassini has collected science data throughout its four-year prime mission (2004-08), and has since been approved for a first and second extended mission through 2017. Cassini carries a set of three "fixed" reaction wheels and a backup reaction wheel (reaction wheel #4) is mounted on top of an articulable platform. If necessary, this platform could be articulated to orient the backup reaction wheel with the degraded wheel. The reaction wheels are used primarily for attitude control when precise and stable pointing of a science instrument such as the narrow angle camera is required. In 2001-02, reaction wheel #3 exhibited signs of bearing cage instability. As a result, reaction wheel #4 was articulated to align with reaction wheel #3. Beginning in July 2003, Cassini was controlled using wheel #1, #2, and #4. From their first use in the spring of 2000 until today, reaction wheels #1 and #2 have accumulated more than3.5 billions revolutions each. As such, in spite of very carefully management of the wheel spin rates by the mission operation team, there are some observed increases in the drag torque of the wheels' bearings. Hence, the mission operations team must prepare for the contingency scenario in which the reaction wheel #1 (in addition to wheel #3) had degraded. In this hypothetical fault scenario, the two remaining reaction wheels (#2 and #4) will not be able to provide precise and stable three-axis control of the spacecraft. In this study, we evaluate the feasibility of controlling Cassini using the two remaining reaction wheels and four thrusters to meet the science pointing requirements for two key science operational modes: the Optical Remote Sensing and Downlink, Fields, Particles, & Waves operation modes. The performance (e.g., pointing control error, pointing stability, hydrazine consumption rate, etc.) of the hybrid controllers in both operations scenarios will be compared with those achieved using an all-thruster controller design. Strength and weaknesses of the hybrid control architecture are assessed quantitatively.

Cassini↗

Radiochromic film based transit dosimetry for verification of dose delivery with intensity modulated radiotherapy

Purpose: To evaluate the transit dose based patient specific quality assurance (QA) of intensity modulated radiation therapy (IMRT) for verification of the accuracy of dose delivered to the patient. Methods: Five IMRT plans were selected and utilized to irradiate a homogeneous plastic water phantom and an inhomogeneous anthropomorphic phantom. The transit dose distribution was measured with radiochromic film and was compared with the computed dose map on the same plane using a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit. Results: While the average gamma index for comparisons of dose distributions was less than one for 98.9% of all pixels from the transit dose with the homogeneous phantom, the passing rate was reduced to 95.0% for the transit dose with the inhomogeneous phantom. Transit doses due to a 5 mm setup error may cause up to a 50% failure rate of the gamma index. Conclusions: Transit dose based IMRT QA may be superior to the traditional QA method since the former can show whether the inhomogeneity correction algorithm from TPS is accurate. In addition, transit dose based IMRT QA can be used to verify the accuracy of the dose delivered to the patient during treatment by revealing significant increases in the failure rate of the gamma index resulting from errors in patient positioning during treatment.

60 APPLIED LIFE SCIENCES↗

Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs.

54 ENVIRONMENTAL SCIENCES↗

Photolysis rates based on Schumann-Runge band approximations and irradiance measurements

The photolysis rate (J3) for CF2Cl2(F-12) in the stratosphere has been computed for three altitudes using measured solar fluxes from a balloon borne spectrometer. The rate is compared with that obtained by computing the attenuated flux using effective cross sections appropriate for the Schumann-Runge bands (J1) (Allen and Frederick, 1982). The result shows that the error in the F-12 photolysis rate caused by using the Allen and Frederick approximation is about 10 percent (J1 less than J3) for altitudes between 32 and 38 km with solar zenith angles less than about 62 degrees. For species other than O2, this implies that the discrepancy in photolysis rates associated with the Schumann-Runge band approximations are not likely to be important. Within the Schumann-Runge band region the computed errors for F-12 photolysis are about 10.5 percent at 38.13 km and increase with decreasing altitude. If this error applies to O2 photolysis, there may be the possibility of an incorrect calculation of net odd oxygen production in photochemical models.

Herman, J. R.↗