Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Assessment of Error in Aerosol Optical Depth Measured by AERONET Due to Aerosol Forward Scattering

We present an analysis of the effect of aerosol forward scattering on the accuracy of aerosol optical depth (AOD) measured by CIMEL Sun photometers. The effect is quantified in terms of AOD and solar zenith angle using radiative transfer modeling. The analysis is based on aerosol size distributions derived from multi-year climatologies of AERONET aerosol retrievals. The study shows that the modeled error is lower than AOD calibration uncertainty (0.01) for the vast majority of AERONET level 2 observations, ~99.53%. Only ~0.47% of the AERONET database corresponding mostly to dust aerosol with high AOD and low solar elevations has larger biases. We also show that observations with extreme reductions in direct solar irradiance do not contribute to level 2 AOD due to low Sun photometer digital counts below a quality control cutoff threshold.

AERONET↗

Thermal Expansion Calculation of Silicate Glasses at 210°C, Based on the Systematic Analysis of Global Databases

Thermal expansion data for more than 5500 compositions of silicate glasses were analyzed statistically. These data were gathered from the scientific literature, summarized in SciGlass© 6.5, a new version of the well known glass property database and information system. The analysis resulted in a data reduction from 5500 glasses to a core of 900, where the majority of the published values is located within commercial glass composition ranges and obtained over the temperature range 20 to 500°C. A multiple regression model for the linear thermal expansivity at 210°C, including error formula and detailed application limits, was developed based on those 900 core data from over 100 publications. The accuracy of the model predictions is improved about twice compared to previous work because systematic errors from certain laboratories were investigated and corrected. The standard model error (precision) was 0.37 ppm/K, with R² = 0.985. The 95% confidence interval for individual predictions largely depends on the glass composition of interest and the composition uncertainty. The model is valid for commercial silicate glasses containing Na2O, CaO, Al2O3, K2O, MgO, B2O3, Li2O, BaO, ZrO2, TiO2, ZnO, PbO, SrO, Fe2O3, CeO2, fining agents, and coloring and de-coloring components. In addition, a special model for ultra-low expansion glasses in the system SiO2-TiO2 is presented. The calculations allow optimizing the time-temperature cooling schedule of glassware, the development of glass sealing materials, and the design of specialty glass products that are exposed to varying temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Schottky barrier modulation at PtSi/Si interface by strain and structural deformation

We show, using density functional theory (DFT) calculations, that the Schottky barrier height (SBH) at the PtSi/Si interface can be lowered by uniaxial strain applied not only on Si but also on PtSi. The strain was applied to the (001) direction of Si and PtSi, which is normal for the interface. The SBH of the hole is lowered by 0.08 eV under 2% of tensile strain on Si and by 0.09 eV under 4 % of compressive strain on PtSi. Because the SBH at PtSi/Si contact is approximately 0.2 eV, this amount of reduction can significantly lower the resistance of the PtSi/Si contact; thus applying uniaxial strain on both PtSi and Si possibly enhances the performance of Schottky barrier field effect transistors. Theoretical models of SB formation and conventional structure model are evaluated. It is found that Pt penetration into Si stabilizes the interface and lowers the SBH by approximately 0.1 eV from the bulk-terminated interface model, which implies that conventionally used bulk-terminated interface models have significant errors. Among the theoretical models of SB formation, the model of strong Fermi level pining adequately explains the electron transfer phenomena and SBH, but it has limited ability to explain SBH changes induced by changes of interface structure.

36 MATERIALS SCIENCE↗

Projection-Based Model Reduction for Coupled Conduction—Enclosure Radiation Systems

We report a projection-based reduced order model (pROM) methodology has been developed for transient heat transfer problems involving coupled conduction and enclosure radiation. The approach was demonstrated on two test problems of varying complexity. The reduced order models demonstrated substantial speedups (up to 185×) relative to the full order model with good accuracy (less than 3% L ∞ error). An attractive feature of pROMs is that there is a natural error indicator for the ROM solution: the final residual norm at each time-step of the converged ROM solution. Using example test cases, we discuss how to interpret this error indicator to assess the accuracy of the ROM solution. The approach shows promise for many-query applications, such as uncertainty quantification and optimization. The reduced computational cost of the ROM relative to the full-order model (FOM) can enable the analysis of larger and more complex systems as well as the exploration of larger parameter spaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction of Non-uniform Beam Filling Effects by Vertical Decorrelation: Theory and Simulations

Algorithms for estimating precipitation rates from spaceborne radar observations of apparent radar reflectivity depend on attenuation correction procedures. The algorithm suite for the Ku-band precipitation radar aboard the Tropical Rainfall Measuring Mission satellite is one such example. The well-known problem of nonuniform beam filling is a source of error in the estimates, especially in regions where intense deep convection occurs. The error is caused by unresolved horizontal variability in precipitation characteristics such as specific attenuation, rain rate, and effective reflectivity factor. This paper proposes the use of vertical decorrelation for correcting the nonuniform beam filling error developed under the assumption of a perfect vertical correlation. Empirical tests conducted using ground-based radar observations in the current simulation study show that decorrelation effects are evident in tilted convective cells. However, the problem of obtaining reasonable estimates of a governing parameter from the satellite data remains unresolved.

radar reflectivity↗

Spectral deferred correction methods for high-order accuracy in poroelastic problems

In this work, we investigate high-order accuracy in time integration by examining two operator splitting methods for poroelastic problems: the two-pass and the spectral deferred correction (SDC) methods. To enhance the order of accuracy, the two-pass method partitions a coupled operator symmetrically, whereas the SDC method corrects truncation errors by establishing an error equation. These high-order methods are applied to underlying solution strategies, i.e., monolithic, fixed-stress sequential, and undrained sequential methods. We observe that semi-discretized systems from spatial discretization have forms similar to those of index-1 differential algebraic equations (DAEs), causing order reduction against the two-pass method when it is used in conjunction with either the monolithic or sequential method. On the other hand, the SDC in conjunction with the monolithic method exhibits the desired second-order accuracy in poroelastic problems while increasing the order of accuracy for index-1 DAEs. However, the SDC in conjunction with either of the two sequential methods does not achieve the desired order of accuracy, and maintains first order because the flow equation for poroelasticity has an additional approximation associated with the volumetric strain rate term, which does not yield exactly the same forms as those of conventional DAEs. Thus, the monolithic SDC method can achieve higher-order accuracy, but may require higher computational costs because it involves solving matrix systems larger than those for the sequential methods.

02 PETROLEUM↗

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra is described. The fluorescent intensity If is linearly proportional to the absorption coefficient μ. For studies of surface structures around an element (κ) the fluorescence detection is often the mode of choice. However, the measurement may suffer from a self-absorption (SA) effect which nonlinearly distorts the spectra. The effect is severe when κ is concentrated or the measurements are carried out in certain geometries. Here, the correlations among emission events in compounds are examined following resonance X-ray core-electron excitation within κ. Under conditions leading to SA, If emitted from κ apparently has a conjugated relationship with the fluorescent intensities simultaneously emitted from other elements (ξ). Normalizing the former (κ) by the latter (ξ) will largely remove SA effects and reduce this nonlinear problem to a tractable linear problem. This does result in a moderate reduction of the spectral amplitude due to the so-called secondary emission from ξ excited by the emission from κ. Nonetheless, the resulting spectra will allow one to accurately determine bond distances and disorder and, in some respects, can be superior to spectra obtained via the absorption channel. For μξ < μκ and grazing incidence geometry, the amplitude reduction can be small and simple normalization is sufficient to restore the spectral integrity with remarkable accuracy. This has been instrumental in unravelling the surface and subsurface structures around cations in amorphous Ga–In–O and Zn–Sn–O films which are otherwise inaccessible due to severe SA effects. This method has also been applied to several samples with μξ ≃ μκ to examine its applicability. For these samples, the amplitude reduction is 12 ± 4% versus their standards for the data measured with the classical 45°/45° geometry. This experimental method is easy to implement. Since If from κ and ξ are measured by the same detector system, it is also superior to other methods in removing systematic errors such as detector system nonlinearity, electronic noise, and some beam instabilities, and in removing spectral imperfections due to, for example, SA effects, diffraction effects and sample inhomogeneity. The distortions resulting from the latter can be severe in the spectra measured in transmission mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of super smooth optics to extra-solar planet detection

The observational constraints on direct detection of extrasolar planets around nearby stars are defined. The design of an instrument capable of meeting these goals requires the efficient reduction of diffracted and scattered light by about three orders of magnitude below the airy wings of the unapodized aperture. The diffraction reduction is achieved through the high-efficiency coronagraph, which uses Gaussian occulting masks in the first focus to concentrate better diffracted light in the pupil plane. Laboratory experiments confirm this high efficiency to the limits set by the experimental setup. Scattering due to midspatial scale figure error in the mirrors must also be reduced to a comparable level.

Terrile, Richard J.↗

Results from 13-cm absorptivity and H2SO4 abundance profiles from the Season 10 (1986) Pioneer Venus Orbiter radio occultation experiment

Results are reported from 13-cm radio-occultation absorptivity measurements of H2SO4 in the northern-hemisphere atmosphere of Venus, obtained by the Pioneer Venus Orbiter on 23 orbits during late 1986 and early 1987. The theoretical basis of the occultation measurements is explained; the error-analysis procedures are outlined; and the data are presented in tables and graphs. The abundance and distribution of gaseous H2SO4 in the equatorial zone (11-25 deg N) are found to be significantly different from those at latitudes above 36 deg N, and evidence for a reduction in H2SO4 abundance since the 1979 measurements is detected.

Jenkins, Jon M.↗

Development of a microcomputer-based magnetic heading sensor

This paper explores the development of a flux-gate magnetic heading reference using a single-chip microcomputer to process heading information and to present it to the pilot in appropriate form. This instrument is intended to replace the conventional combination of mechanical compass and directional gyroscope currently in use in general aviation aircraft, at appreciable savings in cost and reduction in maintenance. Design of the sensing element, the signal processing electronics, and the computer algorithms which calculate the magnetic heading of the aircraft from the magnetometer data have been integrated in such a way as to minimize hardware requirements and simplify calibration procedures. Damping and deviation errors are avoided by the inherent design of the device, and a technique for compensating for northerly-turning-error is described.

Garner, H. D.↗

Decentralized Control of Sound Radiation Using Iterative Loop Recovery

A decentralized model-based control strategy is designed to reduce low-frequency sound radiation from periodically stiffened panels. While decentralized control systems tend to be scalable, performance can be limited due to modeling error introduced by the unmodeled interaction between neighboring control units. Since bounds on modeling error are not known in advance, it is difficult to ensure the decentralized control system will be robust without making the controller overly conservative. Therefore an iterative approach is suggested, which utilizes frequency-shaped loop recovery. The approach accounts for modeling error introduced by neighboring control loops, requires no communication between subsystems, and is relatively simple. The control strategy is evaluated numerically using a model of a stiffened aluminum panel that is representative of the sidewall of an aircraft. Simulations demonstrate that the iterative approach can achieve significant reductions in radiated sound power from the stiffened panel without destabilizing neighboring control units.

Schiller, Noah H.↗

On-the-Fly Mapping for Calibrating Directional Antennas

An improved method of calibrating a large directional radio antenna of the type used in deep-space communication and radio astronomy has been developed. This method involves a raster-scanning-and-measurement technique denoted on-the-fly (OTF) mapping, applied in consideration of the results of a systematic analysis of the entire measurement procedure. Phenomena to which particular attention was paid in the analysis include (1) the noise characteristics of a total-power radiometer (TPR) that is used in the measurements and (2) tropospherically induced radiometer fluctuations. The method also involves the use of recently developed techniques for acquisition and reduction of data. In comparison with prior methods used to calibrate such antennas, this method yields an order-of-magnitude improvement in the precision of determinations of antenna aperture efficiency, and improvement by a factor of five or more in the precision of determination of pointing error and beam width. Prerequisite to a meaningful description of the present method is some background information concerning three aspects of the problem of calibrating an antenna of the type in question: In OTF mapping measurements in which a TPR is used, the desired data are the peak temperature corresponding to a radio source, the pointing offset when the antenna is commanded to point toward the source, and the shape of the main lobe of the antenna beam, all as functions of the antenna beam elevation and azimuth angles. These data enable one to calculate the (1) antenna aperture efficiency by comparing the measured peak temperature with that expected for a 100-percent-efficient antenna, (2) the mechanical pointing error resulting from small misalignments of various parts of the antenna structure, and (3) misalignments of the antenna subreflector and other mirrors. For practical reasons having to do with obtaining adequate angular resolution and all-sky coverage, it is necessary to perform azimuth and elevation scans fairly rapidly. Many natural radio sources used in calibrating antennas are only approximately pointlike: some sources subtend angles greater than the beam width of a given antenna. In such a case, the antenna partially resolves the source structure and does not collect all of the radiation emitted by the source. This makes it necessary to estimate how much of the total known radiation from the source would actually be collected by the antenna if it were 100-percent efficient. The resulting estimate, leading to a source-size correction factor, introduces another degree of uncertainty to the measurements. OTF mapping can remove this uncertainty

Rochblatt, David↗

Automating the Study of Microbial Adaptation Dynamics on and off the ISS

The International Space Station (ISS) not only serves as a unique environment for humans, but also the microorganisms that join alongside. Many microbes present on the spacecraft arrive via humans, and as they interact with different surfaces they begin to inhabit those locations. Much like how human health has shown to be impacted by these extreme environments, microbial viability and response to stress also changes. Experimental evolution (EE) can aid in studying how microbes’ growth and activity changes within the ISS environments by applying controlled stressors to microbial cultures and monitoring their response over generations. EE studies are commonly done manually in laboratories, but, with multiple environmental variables to measure and adjust, it becomes highly labor-intensive, prone to human error, and challenging to scale. A multipurpose automated EE system named the AADEC has been developed to address these problems. This system integrates multiple sensors into a single fluidic chamber using UV-C flux, temperature, and media composition as stressors. AADEC contains five sensors: oxidation-reduction potential, electrical conductivity, pH, dissolved oxygen, and optical density. On their own, each is able to provide certain information on growth rate or metabolism; together, they show in detail how stressors affect life. AADEC studies can be conducted on Earth and repeated aboard the ISS to see how behavior changes when exposed to space mission stressors such as microgravity and radiation. AADEC’s auxiliary systems include peristaltic pumps for media exchange, magnetic rods for agitation, and a Raspberry Pi microprocessor to monitor, store, and adjust stressor levels real-time. This allows researchers to gather information within rapid generations, data and accuracy which is challenging to achieve through manual studies. With further miniaturization and automation, such as a more robust single-piece fluidics card, AADEC has the potential to be developed as a spacecraft payload. Support: NASA Ames CIF Award

Automating↗

A BI-LEVEL APPROACH TO FUTURE POWER SYSTEM CO-OPTIMIZATION WITH HIGH PENETRATION OF RENEWABLE ENERGY AND RESPONSIVE DEMAND

Electricity generation accounts for nearly half of the total CO2 emissions in the United States. For this reason, the development and integration of renewable resources will play an essential role in achieving the societal objective of mitigating climate change through reduction of greenhouse gas emissions. In conjunction with the environmental benefits of renewable energy, the most common renewable sources, such as wind and solar, also increase the uncertainties surrounding generation in power systems, which adds significant challenges to the system operation and planning. The uncertainties and forecasting errors surrounding renewable generation are normally addressed through the use of reserves from traditional generators. At greater levels of renewable penetration, sufficient generator reserves may not be available or economically viable. In contrast, the promise of demand-side resources in this arena lies in the spatially widespread availability, rapid response potential, and lower cost of features that already exist in the system. However, the challenge of responsive demand arises from the need to understand, manage, and incentivize a very large number of resources to participate effectively in efficient operation of the complex power system. Since demand response comes from the distribution system, microgrids as the basic building blocks of future distribution systems will be a critical environment for the study of demand response. To support integration of microgrids with flexible loads in future power systems, the operational mode of power systems will need to evolve. Therefore, it is going to be critical to have new and efficient co-optimization methods for coordination of the various power market participants and the scheduling of resources in the power systems of the future. Motivated by the rapid increase in renewable penetration, the need for effective demand response programs, and a changing system structure, this dissertation seeks to define a new strategy that supports co-optimization of various participants in power systems with emphasis on high renewable penetration and demand response. This strategy has three components; 1) an exploration of the capabilities of different types of demand response programs in a microgrid, 2) development and implementation of a bi-level framework for co-optimization of the main grid with high renewable penetration and a microgrid with demand response capabilities, and 3) expansion of the bi-level framework from a microgrid to a general distribution system to explore the advantages of the bi-level co-optimization approach over the traditional optimization approach. Conclusions of this work illustrate that the stochastic rolling horizon approach could effectively manage the operation of a microgrid with various demand response programs. In addition, the bi-level approach is a promising co-optimization framework for the transmission and distribution levels that could increase system renewable penetration and reduce operation costs. Compared to the traditional framework, the bi-level framework yields more equitable cost sharing patterns among the market participants as well as better support for the power system evolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Electrochemical Technique: Serial Open Circuit Potentiometry to Examine the Separability of Lanthanides in Molten Salts

The accumulation of lanthanide fission products in molten salts reduces the efficiency of pyroprocessing used nuclear fuel. Lanthanide fission products are notoriously difficult to separate due to their similar physical and electrical properties. We developed a novel electrochemical technique called serial open circuit potentiometry (SOCP) which allows us to delineate between metal deposition reactions with similar reduction potentials to great precision. SOCP has several advantages over traditional open circuit potentiometry including its ability to create 3D plots that describe all metal deposition reactions in a system. This information can be used to precisely determine equilibrium potentials of metal deposition reactions and quantify their error, determine nucleation potentials, and determine the nucleation and growth mechanism. In this work, we demonstrated the effectiveness of SOCP by studying molten salt mixtures containing CeCl3, GdCl3, and both CeCl3 and GdCl3 in LiCl-KCl eutectic.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combining Sparse Approximate Factorizations with Mixed-precision Iterative Refinement

The standard LU factorization-based solution process for linear systems can be enhanced in speed or accuracy by employing mixed-precision iterative refinement. Most recent work has focused on dense systems. We investigate the potential of mixed-precision iterative refinement to enhance methods for sparse systems based on approximate sparse factorizations. In doing so, we first develop a new error analysis for LU- and GMRES-based iterative refinement under a general model of LU factorization that accounts for the approximation methods typically used by modern sparse solvers, such as low-rank approximations or relaxed pivoting strategies. We then provide a detailed performance analysis of both the execution time and memory consumption of different algorithms, based on a selected set of iterative refinement variants and approximate sparse factorizations. Our performance study uses the multifrontal solver MUMPS, which can exploit block low-rank factorization and static pivoting. We evaluate the performance of the algorithms on large, sparse problems coming from a variety of real-life and industrial applications showing that mixed-precision iterative refinement combined with approximate sparse factorization can lead to considerable reductions of both the time and memory consumption.

97 MATHEMATICS AND COMPUTING↗

Correlated environmental corrections in TOPEX/POSEIDON, with a note on ionospheric accuracy

Estimates of the effectiveness of an altimetric correction, and interpretation of sea level variability as a response to atmospheric forcing, both depend upon assuming that residual errors in altimetric corrections are uncorrelated among themselves and with residual sea level, or knowing the correlations. Not surprisingly, many corrections are highly correlated since they involve atmospheric properties and the ocean surface's response to them. The full corrections (including their geographically varying time mean values), show correlations between electromagnetic bias (mostly the height of wind waves) and either atmospheric pressure or water vapor of -40%, and between atmospheric pressure and water vapor of 28%. In the more commonly used collinear differences (after removal of the geographically varying time mean), atmospheric pressure and wave height show a -30% correlation, atmospheric pressure and water vapor a -10% correlation, both pressure and water vapor a 7% correlation with residual sea level, and a bit surprisingly, ionospheric electron content and wave height a 15% correlation. Only the ocean tide is totally uncorrelated with other corrections or residual sea level. The effectiveness of three ionospheric corrections (TOPEX dual-frequency, a smoothed version of the TOPEX dual-frequency, and Doppler orbitography and radiopositioning integrated by satellite (DORIS) is also evaluated in terms of their reduction in variance of residual sea level. Smooth (90-200 km along-track) versions of the dual-frequency altimeter ionosphere perform best both globally and within 20 deg in latitude from the equator. The noise variance in the 1/s TOPEX inospheric samples is approximately (11 mm) squared, about the same as noise in the DORIS-based correction; however, the latter has its error over scales of order 10(exp 3) km. Within 20 deg of the equator, the DORIS-based correction adds (14 mm) squared to the residual sea level variance.

Zlotnicki, V.↗

Distribution System Segmented Model Simplification with Independent Dynamically Changing End-Use Loads

With more emerging technologies in power distribution systems, to support quasi-static time-series (QSTS) simulation over short time frames, accurately modeling the dynamic behavior of end-use load under various conditions is im- portant. However, time and cost can be a burden for the QSTS simulation of thousands of houses representing dynamic load behaviors on large distribution feeders. There are two main contributions of this paper in order to reduce the QSTS simulation complexity. First, the paper presents a method to stochasti- cally model the dynamic behavior of end-use load for QSTS simulations. Second, using the stochastically modeled load behavior as an input to a distribution sys- tem, and building on our previous QSTS simulation simplification/acceleration method that relies on uniform load behavior, this paper presents a segment substitution approach for the simplification of distribution system models with independent dynamically changing end-use loads. Our numerical results show that compared to GridLAB-D, a software tool that simulates end-use load be- havior through physical models, the proposed stochastic modeling approach achieved an 89.3% simulation time reduction for end-use loads, while accurately capturing the temporally changing total load behavior. Moreover, the QSTS simulation of a large test distribution system through OpenDSS showed that the proposed simplification method decreased the feeder simulation time by a factor of three at less than 0.3% voltage error. Compared to our previous method with independent dynamic loads, the voltage error is reduced by a factor of four.

Power distribution system modeling, stochastic pro↗