Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation platform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Evaluating Software Tools for Lipid Identification from Ion Mobility Spectrometry–Mass Spectrometry Lipidomics Data

The unambiguous identification of lipids is a critical component of lipidomics studies and greatly impacts the interpretation and significance of analyses as well as the ultimate biological understandings derived from measurements. The level of structural detail that is available for lipid identifications is largely determined by the analytical platform being used. Mass spectrometry (MS) coupled with liquid chromatography (LC) is the predominant combination of analytical techniques used for lipidomics studies, and these methods can provide fairly detailed lipid identification. More recently, ion mobility spectrometry (IMS) has begun to see greater adoption in lipidomics studies thanks to the additional dimension of separation that it provides and the added structural information that can support lipid identification. At present, relatively few software tools are available for IMS-MS lipidomics data analysis, which reflects the still limited adoption of IMS as well as the limited software support. This fact is even more pronounced for isomer identifications, such as the determination of double bond positions or integration with MS-based imaging. In this review, we survey the landscape of software tools that are available for the analysis of IMS-MS-based lipidomics data and we evaluate lipid identifications produced by these tools using open-access data sourced from the peer-reviewed lipidomics literature.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part I: Initial characterizations

Evaluating commercial Li-ion batteries presents some unique benefits. One of them is to use cells made from established fabrication process and form factor, such as those offered by the 18650 cylindrical configuration, to provide a common platform to investigate and understand performance deficiency and aging mechanism of target chemistry. Such an approach shall afford us to derive relevant information without influence from processing or form factor variability that may skew our understanding on cell-level issues. A series of 1.9 Ah 18650 lithium ion cells developed by a commercial source using a composite positive electrode comprising (LiMn1/3Ni1/3Co1/3O2 + LiMn2O4) is being used as a platform for the investigation of certain key issues, particularly path-dependent aging and degradation in future plug-in hybrid electric vehicle (PHEV) applications, under the US Department of Energy's Applied Battery Research (ABR) program. Here we report in Part I the initial characterizations of the cell performance and Part II some aspects of cell degradation in 2C cycle aging. The initial characterizations, including cell-to-cell variability, are essential for life cycle performance characterization in the second part of the report when cell-aging phenomena are discussed. Due to the composite nature of the positive electrode, the features (or signature) derived from the incremental capacity (IC) of the cell appear rather complex. In this work, the method to index the observed IC peaks is discussed. Being able to index the IC signature in details is critical for analyzing and identifying degradation mechanism later in the cycle aging study.

74 ATOMIC AND MOLECULAR PHYSICS↗

Interinstitutional Study of the New EURO-GANEX Process Resistance by Gamma Irradiation Test Loops

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. However, EURO-GANEX also has various drawbacks that are being addressed. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolysis resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate together the organic and aqueous phases, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analysed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or tracers extraction, and HPLC-MS to quantify the degradation and evaluate the degradation compounds. Additionally, in spite of some differences between the three-irradiation facilities, this inter-institutional study shows that they are three comparative tools, which provide results on the stability towards radiolysis of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OpenACC to FPGA: A Framework for Directive-based High-Performance Reconfigurable Computing

This paper presents a directive-based, high-level programming framework for high-performance reconfigurable computing. It takes a standard, portable OpenACC C program as input and generates a hardware configuration file for execution on FPGAs. We implemented this prototype system using our open-source OpenARC compiler; it performs source-to-source translation and optimization of the input OpenACC program into an OpenCL code, which is further compiled into a FPGA program by the backend Altera Offline OpenCL compiler. Internally, the design of OpenARC uses a high- level intermediate representation that separates concerns of program representation from underlying architectures, which facilitates portability of OpenARC. In fact, this design allowed us to create the OpenACC-to-FPGA translation framework with minimal extensions to our existing system. In addition, we show that our proposed FPGA-specific compiler optimizations and novel OpenACC pragma extensions assist the compiler in generating more efficient FPGA hardware configuration files. Our empirical evaluation on an Altera Stratix V FPGA with eight OpenACC benchmarks demonstrate the benefits of our strategy. To demonstrate the portability of OpenARC, we show results for the same benchmarks executing on other heterogeneous platforms, including NVIDIA GPUs, AMD GPUs, and Intel Xeon Phis. This initial evidence helps support the goal of using a directive-based, high-level programming strategy for performance portability across heterogeneous HPC architectures.

Lee, Seyong↗

Surface-Enhanced Raman Imaging of Intracellular Bioreduction of Chromate in Shewanella oneidensis

This proposed research aims to use novel nanoparticle sensors and spectroscopic tools constituting surface-enhanced Raman spectroscopy (SERS) and Fluorescence Lifetime imaging (FLIM) to study intracellular chemical activities within single bioremediating microorganism. The grand challenge is to develop a mechanistic understanding of chromate reduction and localization by the remediating bacterium Shewanella oneidensis MR-1 by chemical and lifetime imaging. MR-1 has attracted wide interest from the research community because of its potential in reducing multiple chemical and metallic electron acceptors. While several biomolecular approaches to decode microbial reduction mechanisms exist, there is a considerable gap in the availability of sensor platforms to advance research from population-based studies to the single cell level. This study is one of the first attempts to incorporate SERS imaging to address this gap. First, we demonstrate that chromate-decorated nanoparticles can be taken up by cells using TEM and Fluorescence Lifetime imaging to confirm the internalization of gold nanoprobes. Second, we demonstrate the utility of a Raman chemical imaging platform to monitor chromate reduction and localization within single cells. Distinctive differences in Raman signatures of Cr(VI) and Cr(III) enabled their spatial identification within single cells from the Raman images. A comprehensive evaluation of toxicity and cellular interference experiments conducted revealed the inert nature of these probes and that they are non-toxic. Our results strongly suggest the existence of internal reductive machinery and that reduction occurs at specific sites within cells instead of at disperse reductive sites throughout the cell as previously reported. While chromate-decorated gold nanosensors used in this study provide an improved means for the tracking of specific chromate interactions within the cell and on the cell surface, we expect our single cell imaging tools to be extended to monitor the interaction of other toxic metal species.

59 BASIC BIOLOGICAL SCIENCES↗

SRNL Review And Assessment Of WTP UFP-02 Sparger Design And Testing

During aerosol testing conducted by Parsons Constructors and Fabricators, Inc. (PCFI), air sparger plugging was observed in small-scale and medium-scale testing. Because of this observation, personnel identified a concern that the steam spargers in Pretreatment Facility vessel UFP-02 could plug during Waste Treatment and Immobilization Plant (WTP) operation. The U. S. Department of Energy (DOE) requested that Savannah River National Laboratory (SRNL) provide consultation on the evaluation of known WTP bubbler, and air and steam sparger issues. The authors used the following approach for this task: reviewed previous test reports (including smallscale testing, medium-scale testing, and Pretreatment Engineering Platform [PEP] testing), met with Bechtel National, Inc. (BNI) personnel to discuss sparger design, reviewed BNI documents supporting the sparger design, discussed sparger experience with Savannah River Site Defense Waste Processing Facility (DWPF) and Sellafield personnel, talked to sparger manufacturers about relevant operating experience and design issues, and reviewed UFP-02 vessel and sparger drawings.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Payload isolation and precision pointing for the 1990's

The design of a pointing system that is applicable for a variety of payloads is examined. The system employs a very soft interface coupled with inertial control torques which use reaction wheels or control moment gyros. The fundamental stability and disturbance rejection characteristics of simple gimbal pointing systems and the soft mounted inertially reacting concept are evaluated and compared. It is observed that in simple and two-stage gimbal systems there is dynamic interaction with the basebody and these types of systems are not applicable for a Space Station/Space Platform environment in which system dynamics are uncertain; however, the soft mounted inertially reacting concept minimizes the dynamic interaction with the basebody and retains stability. It is concluded that the soft mounted inertially reacting concept has the pointing accuracy and disturbance isolation of a free flying spacecraft while still obtaining power, communication, orbit maintenance, and servicing from a basebody.

Sirlin, S. W.↗

The observed distribution of atmospheric ozone and its variations

It is pointed out that both the total amount and the vertical distribution of atmospheric ozone are presently measured routinely by various ground-based and satellite-borne instruments and by instruments mounted on different carrier platforms such as balloons, aircraft, and rockets. The techniques of observing atmospheric ozone are discussed, taking into account the determination of total ozone, the Dobson spectrophotometer, the Brewer spectrophotometer, the M-83 Filter Ozonometer, and satellite techniques. In a discussion of studies of vertical distribution, remote systems are considered along with in situ measurements. Attention is given to ground-based methods, satellite platforms, backscatter measurements, limb observations, electrochemical methods, chemiluminescent methods, optical methods, and rocket observations. A number of graphs showing the observed distribution of atmospheric ozone are also presented, and changes in this distribution are evaluated.

London, J.↗

QUEST/Ada (Query Utility Environment for Software Testing of Ada): The development of a prgram analysis environment for Ada, task 1, phase 2

The results of research and development efforts are described for Task one, Phase two of a general project entitled The Development of a Program Analysis Environment for Ada. The scope of this task includes the design and development of a prototype system for testing Ada software modules at the unit level. The system is called Query Utility Environment for Software Testing of Ada (QUEST/Ada). The prototype for condition coverage provides a platform that implements expert system interaction with program testing. The expert system can modify data in the instrument source code in order to achieve coverage goals. Given this initial prototype, it is possible to evaluate the rule base in order to develop improved rules for test case generation. The goals of Phase two are the following: (1) to continue to develop and improve the current user interface to support the other goals of this research effort (i.e., those related to improved testing efficiency and increased code reliable); (2) to develop and empirically evaluate a succession of alternative rule bases for the test case generator such that the expert system achieves coverage in a more efficient manner; and (3) to extend the concepts of the current test environment to address the issues of Ada concurrency.

Brown, David B.↗

Goddard's New Data Analysis System

After evaluating the total lifetime costs of various commercial systems, it was determined that an in-house development would be more cost-effective in the long run. Matlab was chosen as the development platform, since it is now being taught to most engineering students. The presentation will discuss the specifications of the system.

Worth, Daniel B.↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

NREL's advanced distribution management system (ADMS) test bed is a vendor-neutral resource for evaluating existing and future ADMS functionalities in a realistic laboratory setting. The test bed uses Opal-RT's ePHASORsim and eMEGAsim products interfaced with an OpenDSS power system simulation through the HELICS cosimulation platform developed by multiple DOE laboratories; and with power and controller hardware. NREL will present an overview of the test bed and the technologies included within it, and also some examples of how the test bed has been used to address industry challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemical Routes for the Valorization of Biomass-Derived Feedstocks: From Chemistry to Application

The drive to reduce consumption of fossil resources, coupled with expanding capacity for renewable electricity, invites the exploration of new routes to utilize this energy for the sustainable production of fuels, chemicals, and materials. Biomass represents a possible source of platform precursors for such commodities due to its inherent ability to fix CO2 in the form of multi-carbon organic molecules. Electrochemical methods for the valorization of biomass are thus intriguing, but there is a need to objectively evaluate this field and define the opportunity space by identifying pathways suited to electrochemistry. In this contribution we offer a comprehensive, critical review of recent advances in low-temperature (liquid phase), electrochemical reduction and oxidation of biomass-derived intermediates (polyols, furans, carboxylic acids, amino acids, and lignin), with emphasis on identifying the state-of-the-art for each documented reaction. Progress in computational modeling is also reviewed. We further suggest a number of possible reactions that have not yet been explored but which are expected to proceed based on established routes to transform specific functional groups. We conclude with a critical discussion of technological challenges for scale-up, fundamental research needs, process intensification opportunities (e.g., by pairing compatible oxidations and reductions), and new benchmarking standards that will be necessary to accelerate progress toward application in this still-nascent field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Airborne/spaceborne radar - Panel report

Mobile radar platforms can provide unique observations of geophysical phenomena for scientific research and for operational applications such as reconnaissance and flight safety. Airborne or spaceborne radar can provide: (1) observations where it is often impractical or too costly to place a ground-based radar, (2) surveillance over a large area or over a long time period when the system of interest is moving, (3) the ability to adjust viewing angles to minimize uncertainties due to viewing geometry, for example, along a dual-Doppler baseline, (4) measurements to complement coincident observations from other remote and in situ sensors, and (5) evaluation of ground surface properties and their impact on the evolution of the boundary-layer and their role in storm systems, hydrology, and earth surface radiation balance. However, advances in signal processing, antenna design, power amplifiers, and other critical system components will be required if radar measurements from airborne and spaceborne platforms are to become a reality.

Jorgensen, David P.↗

First evaluation of the feasibility of MLC tracking using ultrasound motion estimation

Purpose: To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. Methods: The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported via Clarity’s real-time streaming interface to an in-house tracking and delivery software and subsequently used to adapt the MLC aperture. A portal imager measured MV treatment field/MLC apertures and motion platform positions throughout each experiment to independently quantify system latency and geometric error. Based on the measured range of latency values, a prostate stereotactic body radiation therapy (SBRT) delivery was performed with three realistic motion trajectories. The dosimetric impact of system latency on MLC tracking was directly measured using a 3D dosimeter mounted on the motion platform. Results: For 2D US imaging, the overall system latency, including all delay times from the imaging and delivery chain, ranged from 392 to 424 ms depending on the lateral sector size. For 3D US imaging, the latency ranged from 566 to 1031 ms depending on the elevational sweep. The latency-corrected geometric root-mean squared error was below 0.75 mm (2D US) and below 1.75 mm (3D US). For the prostate SBRT delivery, the impact of a range of system latencies (400–1000 ms) on the MLC tracking performance was minimal in terms of gamma failure rate. Conclusions: Real-time MLC tracking based on a noninvasive US input is technologically feasible. Current system latencies are higher than those for x-ray imaging systems, but US can provide full volumetric image data and the impact of system latency was measured to be small for a prostate SBRT case when using a US-like motion input.

60 APPLIED LIFE SCIENCES↗

A Cybersecurity Event Simulation Tool and Platform

Digital Instrumentation and Control Systems (ICSs) have replaced analog control systems in nuclear power plants raising cybersecurity concerns. To study and understand the cybersecurity risks of nuclear power plants both high fidelity models of the plant physics and controllers must be created, and a framework to test and evaluate cyber security events must be established. A testing and evaluation framework of cybersecurity events consists of a method of interfering with control systems, a simulation of the plant network, and a network packet capture and recording tool. Sandia National Labs (SNL) in collaboration with the University of New Mexico’s Institute for Space and Nuclear Power Studies (UNM-ISNPS) is developing such a cybersecurity testing framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-19A-09: Propagation of Organ at Risk Contours for High Dose Rate Brachytherapy Planning for Cervical Cancer: A Deformable Image Registration Comparison

Purpose: To compare the performance of two deformable image registration (DIR) algorithms for contour propagation and to evaluate the accuracy of DIR for use with high dose rate (HDR) brachytherapy planning for cervical cancer. Methods: Five patients undergoing HDR ring and tandem brachytherapy were included in this retrospective study. All patients underwent CT simulation and replanning prior to each fraction (3–5 fractions total). CT-to-CT DIR was performed using two commercially available software platforms: SmartAdapt, Varian Medical Systems (Demons) and Velocity AI, Velocity Medical Solutions (B-spline). Fraction 1 contours were deformed and propagated to each subsequent image set and compared to contours manually drawn by an expert clinician. Dice similarity coefficients (DSC), defined as, DSC(A,B)=2(AandB)/(A+B) were calculated to quantify spatial overlap between manual (A) and deformed (B) contours. Additionally, clinician-assigned visual scores were used to describe and compare the performance of each DIR method and ultimately evaluate which was more clinically acceptable. Scoring was based on a 1–5 scale—with 1 meaning, “clinically acceptable with no contour changes” and 5 meaning, “clinically unacceptable”. Results: Statistically significant differences were not observed between the two DIR algorithms. The average DSC for the bladder, rectum and rectosigmoid were 0.82±0.08, 0.67±0.13 and 0.48±0.18, respectively. The poorest contour agreement was observed for the rectosigmoid due to limited soft tissue contrast and drastic anatomical changes, i.e., organ shape/filling. Two clinicians gave nearly equivalent average scores of 2.75±0.91 for SmartAdapt and 2.75±0.94 for Velocity AI—indicating that for a majority of the cases, more than one of the three contours evaluated required major modifications. Conclusion: Limitations of both DIR algorithms resulted in inaccuracies in contour propagation in the pelvic region, thus hampering the clinical utility of this technology. Further work is required to optimize these algorithms and take advantage of the potential of DIR for HDR brachytherapy planning.

60 APPLIED LIFE SCIENCES↗