Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Predicting the Cetane Number, Yield Sooting Index, Kinematic Viscosity, and Cloud Point for Catalytically Upgraded Pyrolysis Oil Using Artificial Neural Networks

Abstract The conversion of biomass using fast pyrolysis has the potential to be significantly less expensive at scale compared to alternative methods such as fermentation and gasification. Selective upgrading of the products of fast pyrolysis through chemical catalysis produces compounds with lower oxygen content and lower acidity; however, identifying the specific catalytic pathways for producing viable fuels and fuel additives often requires a trial-and-error approach. Specifically, key properties of the compounds must be experimentally tested to evaluate the viability of the resultant compounds. The present work proposes predictive models constructed with artificial neural networks (ANNs) for cetane number (CN), yield sooting index (YSI), kinematic viscosity (KV), and cloud point (CP), with blind test set median absolute errors of 5.14 cetane units, 3.36 yield sooting index units, 0.07 millimeters squared per second, and 4.89 degrees Celsius, respectively. Furthermore, the cetane number, yield sooting index, kinematic viscosity, and cloud point were predicted for over three hundred expected products from the catalytic upgrading of pyrolysis oil. It was discovered that 130 of these compounds have predicted cetane numbers greater than 40, with four of these compounds possessing predicted yield sooting index values significantly less than that of diesel fuel and predicted viscosities and cloud points comparable to that of diesel fuel.

09 BIOMASS FUELS↗

Atomic bonding effects in annular dark field scanning transmission electron microscopy. II. Experiments

Quantitatively calibrated annular dark field scanning transmission electron microscopy (ADF-STEM) imaging experiments were compared to frozen phonon multislice simulations adapted to include chemical bonding effects. Having carefully matched simulation parameters to experimental conditions, a depth-dependent bonding effect was observed for high-angle ADF-STEM imaging of aluminum nitride. This result is explained by computational predictions, systematically examined in the preceding portion of this study, showing the propagation of the converged STEM beam to be highly sensitive to net interatomic charge transfer. Thus, although uncertainties in experimental conditions and simulation accuracy remain, the computationally predicted experimental bonding effect withstands the experimental testing reported here.

42 ENGINEERING↗

Semiconductor neutron detectors using depleted uranium oxide

This paper reports on recent attempts to develop and test a new type of solid-state neutron detector fabricated from uranium compounds. It has been known for many years that uranium oxide (UO2), triuranium octoxide (U3O8) and other uranium compounds exhibit semiconducting characteristics with a broad range of electrical properties. We seek to exploit these characteristics to make a direct-conversion semiconductor neutron detector. In such a device a neutron interacts with a uranium nucleus, inducing ssion. The ssion products deposit energy-producing, detectable electron-hole pairs. The high energy released in the ssion reaction indicates that noise discrimination in such a device has the potential to be excellent. Schottky devices were fabricated using a chemical deposition coating technique to deposit UO2 layers a few microns thick on a sapphire substrate. Schottky devices have also been made using a single crystal from UO2 samples approximately 500 microns thick. Neutron sensitivity simulations have been performed using GEANT4. Neutron sensitivity for the Schottky devices was tested experimentally using a 252Cf source.

neutron detection, uranium oxide, semiconductor↗

Interdigitated electrode geometry variation and external quantum efficiency of GaN/AlGaN-based metal-semiconductor-metal UV photodetectors

Aluminum gallium-nitride (Al x Ga 1–x N)-based metal–semiconductor–metal (MSM) ultraviolet photodetectors photodetectors (PD’s) have been successfully designed and fabricated using conventional photolithography techniques and tested experimentally to study their spectral sensitivity across different Al content, x, with x varying from 0 to 0.3. (Al)GaN-based UV PD’s have wide and tunable direct band gaps. The ability to easily select the photodetected wavelength by simply varying the aluminum content of GaN thin film (Al x Ga 1–x N) is a significant advantage of these group III–V compounds. Typically, MSM PD’s grown on (Al)GaN thin films result in ultrafast photodetection because of their highly mobile carriers. These devices are limited by the carrier transit time due to the negligible capacitance presented by the interdigitated fingers. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the devices’ performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Here, coupled with the independently measured Hall mobility and electric field, we computed the carrier transit time of the devices to be as short as 1.31 ps and the bias-voltage–independent external quantum efficiencies were as high as 70% at 60 V for n-doped and intrinsic devices when operated in the reverse bias regime. Here, (Al x )Ga 1–x N photodetectors were designed to explore spectral sensitivity by altering x from 0 to 0.3.

42 ENGINEERING↗

Grid artifact reduction for direct digital radiography detectors based on rotated stationary grids with homomorphic filtering

Purpose: Grid artifacts are caused when using the antiscatter grid in obtaining digital x-ray images. In this paper, research on grid artifact reduction techniques is conducted especially for the direct detectors, which are based on amorphous selenium. Methods: In order to analyze and reduce the grid artifacts, the authors consider a multiplicative grid image model and propose a homomorphic filtering technique. For minimal damage due to filters, which are used to suppress the grid artifacts, rotated grids with respect to the sampling direction are employed, and min-max optimization problems for searching optimal grid frequencies and angles for given sampling frequencies are established. The authors then propose algorithms for the grid artifact reduction based on the band-stop filters as well as low-pass filters. Results: The proposed algorithms are experimentally tested for digital x-ray images, which are obtained from direct detectors with the rotated grids, and are compared with other algorithms. It is shown that the proposed algorithms can successfully reduce the grid artifacts for direct detectors. Conclusions: By employing the homomorphic filtering technique, the authors can considerably suppress the strong grid artifacts with relatively narrow-bandwidth filters compared to the normal filtering case. Using rotated grids also significantly reduces the ringing artifact. Furthermore, for specific grid frequencies and angles, the authors can use simple homomorphic low-pass filters in the spatial domain, and thus alleviate the grid artifacts with very low implementation complexity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.

60 APPLIED LIFE SCIENCES↗

SU-E-T-524: In-Vivo Diode Dosimetry Proton Therapy Range Verification Validation Study for Pediatric CSI

Purpose: With the aim of reducing acute esophageal radiation toxicity in pediatric patients receiving craniospinal irradiation (CSI), we investigated the implementation of an in-vivo, adaptive proton therapy range verification methodology. Simulation experiments and in-phantom measurements were conducted to validate the range verification technique for this clinical application. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification for a prostate treatment case by correlating properties of the detector signal to the water equivalent path length (WEPL). We propose to extend the methodology to verify range distal to the vertebral body for pediatric CSI cases by placing this small volume dosimeter in the esophagus of the anesthetized patient immediately prior to treatment. A set of calibration measurements was performed to establish a time signal to WEPL fit for a “scout” beam in a solid water phantom. Measurements are compared against Monte Carlo simulation in GEANT4 using the Tool for Particle Simulation (TOPAS). Results: Measurements with the diode array in a spread out Bragg peak of 14 cm modulation width and 15 cm range (177 MeV passively scattered beam) in solid water were successfully validated against proton fluence rate simulations in TOPAS. The resulting calibration curve allows for a sensitivity analysis of detector system response with dose rate in simulation and with individual diode position through simulation on patient CT data. Conclusion: Feasibility has been shown for the application of this range verification methodology to pediatric CSI. An in-vivo measurement to determine the WEPL to the inner surface of the esophagus will allow for personalized adjustment of the treatment plan to ensure sparing of the esophagus while confirming target coverage. A Toltz acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-04: A Study of Cherenkov Light Generated and Collected in Plastic Scintillation Detector

Purpose: To study Cherenkov light emission in plastic scintillation detectors (PSDs) from a theoretical point of view to identify situations that may arise where the calibration coefficient obtained in one condition is not applicable to another condition. By identifying problematic situations, we hope to provide guidance on how to confidently use PSDs. Methods: Cherenkov light emission in PSD was modelled using basic physical principles. In particular, changes in refractive index as a function of wavelength were accounted for using the Sellmeier empirical equation. Both electron and photon beams were considered. For photons, realistic distributions of secondary charged particles were calculated using Klein-Nishina’s formula. Cherenkov production and collection in PSDs were studied for a range of parameters including beam energy, charged particle momentum distribution, detector orientation and material composition. Finally, experimental validation was made using a commercial plastic scintillation detector. Results: In specific situations, results show that the Cherenkov spectrum coupled in the PSD can deviate from its expected behaviour (i.e. one over the square of the wavelength). In these cases were the model is realistic it is possible to see a peak wavelength instead of a monotonically decreasing function. Consequences of this phenomenon are negligible when the momentum of charged particle is distributed randomly, but in some clinically relevant cases, such as an electron beam at depth close to R50 or for photon beams with minimal scatter component, the value of the calibration coefficient can be altered. Experimental tests with electron beams showed changes in the Cherenkov light ratio, the parameter used in the calibration of PSDs, up to 2–3% depending on the PSD orientation. Conclusion: This work is the first providing a physical explanation for apparent change in PSD calibration coefficient. With this new information at hand, it will be possible to better guide the clinical use of PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solid water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.

60 APPLIED LIFE SCIENCES↗

Enhanced resonant ultrasound spectroscopy for measurement of the elastic properties of multi-material systems

Understanding the elastic properties of materials is critical for their safe incorporation and predictable performance. Current methods of bulk elastic characterization often have notable limitations for in situ structural applications, with usage restricted to simple geometries and material distributions. To address these existing issues, this study sought to expand the capabilities of resonant ultrasound spectroscopy (RUS), an established nondestructive evaluation method, to include the characterization of isotropic multi-material samples. In this work, finite-element-based RUS analysis consisted of numerical simulations and experimental testing of composite samples comprised of material pairs with varying elasticity and density contrasts. Utilizing genetic algorithm inversion and mode matching, our results demonstrate that elastic properties of multi-material samples can be reliably identified within several percent of known or nominal values using a minimum number of identified resonance modes, given sample mass is held consistent. The accurate recovery of material properties for composite samples of varying material similarity and geometry expands the pool of viable samples for RUS and advances the method towards in situ inspection and evaluation.

36 MATERIALS SCIENCE↗

Mitochondrial DNA and temperature tolerance in lager yeasts

A growing body of research suggests that the mitochondrial genome (mtDNA) is important for temperature adaptation. In the yeast genus Saccharomyces , species have diverged in temperature tolerance, driving their use in high- or low-temperature fermentations. Here, we experimentally test the role of mtDNA in temperature tolerance in synthetic and industrial hybrids ( Saccharomyces cerevisiae × Saccharomyces eubayanus or Saccharomyces pastorianus ), which cold-brew lager beer. We find that the relative temperature tolerances of hybrids correspond to the parent donating mtDNA, allowing us to modulate lager strain temperature preferences. The strong influence of mitotype on the temperature tolerance of otherwise identical hybrid strains provides support for the mitochondrial climactic adaptation hypothesis in yeasts and demonstrates how mitotype has influenced the world’s most commonly fermented beverage.

59 BASIC BIOLOGICAL SCIENCES↗

Design of intrinsically disordered protein variants with diverse structural properties

Intrinsically disordered proteins (IDPs) perform a broad range of functions in biology, suggesting that the ability to design IDPs could help expand the repertoire of proteins with novel functions. Computational design of IDPs with specific conformational properties has, however, been difficult because of their substantial dynamics and structural complexity. We describe a general algorithm for designing IDPs with specific structural properties. We demonstrate the power of the algorithm by generating variants of naturally occurring IDPs that differ in compaction, long-range contacts, and propensity to phase separate. We experimentally tested and validated our designs and analyzed the sequence features that determine conformations. We show how our results are captured by a machine learning model, enabling us to speed up the algorithm. Our work expands the toolbox for computational protein design and will facilitate the design of proteins whose functions exploit the many properties afforded by protein disorder.

Science & Technology - Other Topics↗

Robust deep learning–based protein sequence design using ProteinMPNN

Although deep learning has revolutionized protein structure prediction, almost all experimentally characterized de novo protein designs have been generated using physically based approaches such as Rosetta. Here, we describe a deep learning–based protein sequence design method, ProteinMPNN, that has outstanding performance in both in silico and experimental tests. On native protein backbones, ProteinMPNN has a sequence recovery of 52.4% compared with 32.9% for Rosetta. The amino acid sequence at different positions can be coupled between single or multiple chains, enabling application to a wide range of current protein design challenges. We demonstrate the broad utility and high accuracy of ProteinMPNN using x-ray crystallography, cryo–electron microscopy, and functional studies by rescuing previously failed designs, which were made using Rosetta or AlphaFold, of protein monomers, cyclic homo-oligomers, tetrahedral nanoparticles, and target-binding proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Garnet crystallization does not drive oxidation at arcs

Arc magmas, the building blocks of continental crust, are depleted in total iron (Fe), have higher ratios of oxidized Fe to total Fe (Fe 3+ /∑Fe), and record higher oxygen fugacities ( f O 2 ’s) compared with magmas erupted at mid-ocean ridges. Garnet crystallization could explain these observations if garnet removes substantial amounts of Fe 2+ , but not Fe 3+ , from magma, yet this model for continental crust generation has never been tested experimentally. Analysis of garnets and melts in laboratory experiments show that the compatibilities of Fe 2+ and Fe 3+ in garnet are of similar magnitudes. Our results indicate that fractional crystallization of garnet-bearing cumulates will remove 22 % of total Fe from primary arc basalts but negligibly alter the Fe 3+ /∑Fe ratio and f O 2 of the melt. Garnet crystallization is unlikely to be responsible for the relatively oxidized nature of basaltic arc magmas or the Fe-depletion trend observed in continental crust.

Science & Technology - Other Topics↗

How Germinal Centers Evolve Broadly Neutralizing Antibodies: the Breadth of the Follicular Helper T Cell Response

Many HIV-1-infected patients evolve broadly neutralizing antibodies (bnAbs). This evolutionary process typically takes several years and is poorly understood as selection taking place in germinal centers occurs on the basis of antibody affinity. B cells with the highest-affinity receptors tend to acquire the most antigen from the follicular dendritic cell (FDC) network and present the highest density of cognate peptides to follicular helper T (Tfh) cells, which provide survival signals to the B cell. bnAbs are therefore expected to evolve only when the B cell lineage evolving breadth is consistently capturing and presenting more peptides to Tfh cells than other lineages of more specific B cells. Here we develop mathematical models of Tfh cells in germinal centers to explicitly define the mechanisms of selection in this complex evolutionary process. Our results suggest that broadly reactive B cells presenting a high density of peptides bound to major histocompatibility complex class II molecules (pMHC) are readily outcompeted by B cells responding to lineages of HIV-1 that transiently dominate the within host viral population. Conversely, if broadly reactive B cells acquire a large variety of several HIV-1 proteins from the FDC network and present a high diversity of several pMHC, they can be rescued by a large fraction of the Tfh cell repertoire in the germinal center. Under such circumstances the evolution of bnAbs is much more consistent. Increasing either the magnitude of the Tfh cell response or the breadth of the Tfh cell repertoire markedly facilitates the evolution of bnAbs. Because both the magnitude and breadth can be increased by vaccination with several HIV-1 proteins, this calls for experimental testing. Many HIV-infected patients slowly evolve antibodies that can neutralize a large variety of viruses. Such broadly neutralizing antibodies (bnAbs) could in the future become therapeutic agents. bnAbs appear very late, and patients are typically not protected by them. At the moment, we fail to understand why this takes so long and how the immune system selects for broadly neutralizing capacity. Typically, antibodies are selected based on affinity and not on breadth. We developed mathematical models to study two different mechanisms by which the immune system can select for broadly neutralizing capacity. One of these is based upon the repertoire of different follicular helper T (Tfh) cells in germinal centers. In conclusion, we suggest that broadly reactive B cells may interact with a larger fraction of this repertoire and demonstrate that this would select for bnAbs. Intriguingly, this suggests that broadening the Tfh cell repertoire by vaccination may speed up the evolution of bnAbs.

59 BASIC BIOLOGICAL SCIENCES↗

Unlocking the Constraints of Cyanobacterial Productivity: Acclimations Enabling Ultrafast Growth

ABSTRACT Harnessing the metabolic potential of photosynthetic microbes for next-generation biotechnology objectives requires detailed scientific understanding of the physiological constraints and regulatory controls affecting carbon partitioning between biomass, metabolite storage pools, and bioproduct synthesis. We dissected the cellular mechanisms underlying the remarkable physiological robustness of the euryhaline unicellular cyanobacterium Synechococcus sp. strain PCC 7002 ( Synechococcus 7002) and identify key mechanisms that allow cyanobacteria to achieve unprecedented photoautotrophic productivities (~2.5-h doubling time). Ultrafast growth of Synechococcus 7002 was supported by high rates of photosynthetic electron transfer and linked to significantly elevated transcription of precursor biosynthesis and protein translation machinery. Notably, no growth or photosynthesis inhibition signatures were observed under any of the tested experimental conditions. Finally, the ultrafast growth in Synechococcus 7002 was also linked to a 300% expansion of average cell volume. We hypothesize that this cellular adaptation is required at high irradiances to support higher cell division rates and reduce deleterious effects, corresponding to high light, through increased carbon and reductant sequestration. IMPORTANCE Efficient coupling between photosynthesis and productivity is central to the development of biotechnology based on solar energy. Therefore, understanding the factors constraining maximum rates of carbon processing is necessary to identify regulatory mechanisms and devise strategies to overcome productivity constraints. Here, we interrogate the molecular mechanisms that operate at a systems level to allow cyanobacteria to achieve ultrafast growth. This was done by considering growth and photosynthetic kinetics with global transcription patterns. We have delineated putative biological principles that allow unicellular cyanobacteria to achieve ultrahigh growth rates through photophysiological acclimation and effective management of cellular resource under different growth regimes.

cyanobacteria↗

Raman Scattering of Light by Molecules of Methyl Orange Dye on the Surface of Silicon Containing Ion-Synthesized Silver Nanoparticles

The possibility of using a new composite material based on porous silicon containing silver nanoparticles and synthesized by means of a unique implantation nanotechnology as an optically sensitive material in biological and chemical sensors is tested experimentally. It is demonstrated that detection of small amounts of the studied organic substance (methyl orange dye) is possible due to the effect of surface-enhanced Raman scattering (SERS) from the molecules affected by the local electromagnetic field of the silver nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗